M0.1 Mechanical Legend
ABBREVIATIONS A AMP, AMPERE ABV ABOVE A/C AIR CONDITIONER, AIR CONDITIONING, ABOVE CEILING ACC AIR COOLED CHILLER ACCU AIR COOLED CONDENSING UNIT ADJ ADJUSTABLE AFC ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AEG ABOVE FINISHED GRADE AL ACOUSTIC LINING ANSI AMERICAN MATT STANDARDS INSTITUTE APO AIR PRESSURE DROP ARCH ARCHITECT, ARCHITECTURAL ARI AIR CONDITIONING & REFRIG INSTITUTE ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION & AC ENGINEERS AWE AMERICAN SOCIETY OF MECHANICAL ENGRS ASSY ASSEMBLY ASTAI AMERICAN SOCIETY OF TESTING & MATLS AU% AUXILIARY AWG AMERICAN WIRE GAUGE AWS AMERICAN WELDING SOCIETY AMA AMERICAN WATER WORKS ASSOC. B/F BELOW FLOOR BAS BUILDING AUTOMATION SYSTEM BEAD BACKDRAFT DAMPER SEW BOILER FEED WATER BLDG BUILDING BMS BUILDING MANAGEMENT SYSTEM BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE BOB BOTTOM OF STRUCTURE BTU BRITISH THERMAL UNIT CA COMBUSTION AIR CC CONCRETE CFH CUBIC FEET PER HOUR OEM CUBIC FEET PER MINUTE CHWR/CHNS CHILLED WATER RETURN/SUPPLY CINC CIRCULATING CRT CIRCUIT CL CENTERLINE OLD CEILING CO CLEANOUT CONN CONNECT CONNECTION COP CLEANOUt PLUG COL COLUMN CTE CONNECT TO EXISTING CW DOMESTIC COLD WATER ONIONS CONDENSING WATER RETURN/SUPPLY °C DEGREES CELSIUS D DEPTH DB DIY BULB all DECIBEL DUC DIRECT DIGITAL CONTROL DEG DEGREES CIA (OR 0) DIAMETER DIM DIMENSION DISC DISCONNECT ON DOWN DOM DOMESTIC DS DOWNSPOUT DM DRAWING DX DIRECT EXPANSION EA EACH EAT ENTERING AIR TEMPERATURE EC ELECTRICAL CONTRACTOR IDS ENTERING DIY BULB ELEV ELEVATION ELEC ELECTRICAL ENCL ENCLOSURE EQUIP EOUIFMENT ESP EXTERNAL STATIC PRESSURE ETB EXISTING TO REMAIN ENE ENTERING WET BULB EIYT ENTERING WATER TEMPERATURE EXH EXHAUST EX EXISTING FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FOG FLOOR CLEANOUT FD FIRE DAMPER FF FINISHED FLOOR FLA FULL LOAD AMPS FLEX FLEXIBLE FP FIRE PROTECTION FPM FEET PER MINUTE FT FOOT, FEET FW FILTERED WATER 'F DEGREES FAHRENHEIT G GAS CA GAUGE GAL GALLON GALV GALVANIZED GC GENERAL CONTRACTOR GFI, GFIC GROUND FAULT INTERRUPTER GPD GALLONS PER DAY GPH GALLONS PER HOUR GPM GALLONS PER MINUTE CARD GROUND GW GREASE WASTE H HEIGHT HD HEAD, HUB GRAIN HHWR/HHWS HEATING HOT WATER RETURN/SUPPLY HOA HAND -OFF -AUTOMATIC HP HORSEPOWER, HEAT PUMP HSTAT HUMIDISTAT HTG HEATING HTR HEATER WAC HEATING, VENTILATING & A/C HW DOMESTIC HOT WATER HOUR DOMESTIC RECIRCULATED HOT WATER HYD HYDRANT HZ HERTZ RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City yLLoof Catned �VT�t�G*VAWML DATE: 08/19/19 ID INSIDE DIAMETER IE INVERT ELEVATION IN INCH, INCHES IN WC INCHES OF WATER COLUMN KVA KILOVOLTAMPS KW KILOWATTS OWN KILOWATT-HOUR L INTERNALLY LINED LAT LEAVING AIR TEMPERATURE LBS, # POUNDS LOB LEAVING DRY BULB LP LOW PRESSURE MA LOCKED ROTOR AMPS LTG LIGHTING LWB LEAVING WET BULB LINT LEAVING WATER TEMPERATURE MAX MAXIMUM MCI 1NO BTU PER HOUR MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MO MOTORIZED DAMPER MUCH MECHANICAL MFR MANUFACTURER MH MANHOLE, METAL HALIDE MIN MINIMUM MRCP MAXIMUM OVER CURRENT PROTECTION MID MOUNTED MUA MAKE-UP AIR N/A NOT APPLICABLE N.C. NORMALLY CLOSED NC NOISE CRITERIA NEC NATIONAL ELECTRICAL CODE HIM NATIONAL ELECTRICAL Ill ASSOC. NFPA NATIONAL FIRE PROTECTION ASSOC. NIC NOT IN CONTRACT N.O. NORMALLY OPEN NTS NOT TO SCALE 0/H OVERHEAD CA OUTSIDE AIR (VENTILATION AIR) am OPPOSED BLADE DAMPER OC ON CENTER OD OVERFLOW DRAINAGE, OUTSIDE DIAMETER OPNG OPENING ORD OVERFLOW ROOF DRAIN OS&Y OUTSIDE STEM AND YOKE OSHA OCCUPATIONAL SAFETY &HEALTH ADMIN. PB MEN mum PD PRESSURE DROP PH, 0 PHASE PIV POST INDICATOR VALVE PtBG PLUMBING PSI POUNDS PER SQUARE INCH PRV PRESSURE RELIEF VALVE RA RETURN AIR RCP REFLECTED CEILING PLAN RD ROOF DRAIN RECIRC RECIRCULATE REINF REINFORCING, REINFORCED REL RELOCATED RED REQUIRED REV REVISION, REVISE REX REMOVE EXISTING RH RELATIVE HUMIDITY RED REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RLA RUNNING LOAD AMPS RPM REVOLUTIONS PER MINUTE RR REMOVE AND RELOCATE RE REFRIGERANT SUCTION RWC RAIN WATER CONDUCTOR &4 SUPPLY AIR SAN SANITARY ED SMOKE DETECTOR, STORM DRAIN SECT SECTION SF SOWE FEET, SQUARE FOOT SHT SHEET SM SHEET METAL SMACNA SHEET METAL & A/C CONE RAT'L ASSOC. SIP STATIC PRESSURE SPEC SPECIFICATION SO SQUARE ST STORM WATER STD STANDARD SURF SURFACE SUSP SUSPEND TON TOTAL DYNAMIC HEAD TE TENANT EXHAUST (TOILET) THRU THROUGH TP TOTAL PRESSURE TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TWAITWS TOWER WATER RETURN/SUPPLY TYP TYPICAL Ii UNDERFLOOR U/G UNDERGROUND li UNDERS[AB UL UNDERWRITERS LABORATORIES, INC. ICON UNLESS OTHERWISE NOTED V VOLT, VENT VA VOLT-AMPERE, VALVE VAC VACUUM VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VTR VENT THROUGH ROOF W WATT, WIDTH W/ WITH WIG WITHOUT WIG WET BULB WC WATER COLUMN HVAC SYMBOLS SUPPLY AIR DIFFUSER - SHADING INDICATES PATTERN. NO PATTERN SHOWN EQUALS 4-WAY OR AS NOTED zRETURN OR EXHAUST AIR GRILLE 12'0 ROUND DUCTWORK. DIAMETER IN INCHES 20/12 RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN INTERNALLY LINED DUCT ® SUPPLY OR OUTSIDE AIR DUCT RETURN, RELIEF OR EXHAUST AIR DUCT DIFFUSER/GRILLE LABEL: A B A - TYPE/DESIGNATION B - NECK SIZE (INCHES) C C - AIRFLOW (OEM) GO DEGREE DUCTWORK ELBOW W/ TURNING VANES {T TURNING VANES --� \ RADIUS DUCTWORK ELBOW - YWi ROUND OR RECTANGULAR RECTANGULAR DUCTWORK BRANCH TAKE OFF WITH 45 DEGREE BRANCH INLET HIGH EFFIECENY 'BUCKLEY' TAP WITH DAMPER f7—= DUCTWORK SIZE TRANSITION L IN SUPPLY OR OUTSIDE AIR DUCT UP SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN OR EXHAUST AIR DUCT UP RETURN OR EXHAUST AIR DUCT DOWN IN -LINE 90 DECREE RISE IN DUCT IN -LIE 90 DECREE DROP IN DUCT RISE INCLINED RISE IN DUCT POINT OF CONNECTION - NEW TO EXISTING '4 MANUAL VOLUME DAMPER uD MOTORIZED DAMPER F11111110— FIRE DAMPER TO THERMOSTAT O HUMIDISTAT SO SENSOR © CARBON DIOXIDE SENSOR SD DUCT SMOKE DETECTOR DRAWING NOTE REFERENCE ROUND OVAL OR FLAT OVAL UC UNDERCUT DOOR 3/4' FOR AIRFLOW 1' INTERNALLY LINED RETURN AIR DUCTWORK DUCT MOUNTED SMOKE DETECTOR ROOFTOP UNIT SEAL BETWEEN ALL DUCTS AND ROOF DECK WITH ACOUSTICAL SEALANT PROVIDE FLEX CONNECTION BELOW ROOF DEC( FOR SUPPLY AND RETURN AIR DUCT DROPS END VIEW 1 RTU SECTION DETAIL MI SCALE: NONE SIDE VIEW ROOF TOP UNIT —SEAL BETWEEN ALL DUCTS AND ROOF DECK WITH ACOUSTICAL SEALANT VERTICAL SUPPLY AIR DUCT SHALL BE FULL SIZE OF UNIT OPENING. TRANSITION TO DUCT SIZE INDICATED ON PLAN HAND TIGHT PLUG COPPER CONDENSATE DRAIN LINES PAST CURB TO PREVENT CURB FROM RUST DAMAGE. DO NOT USE PVC FOR CONDENSATE DRAIN LINES. KEEP VERTICAL CONDENSATE LINE A MINIMUM OF 3' FROM CURB 'H' = FAN INLET PRESSURE (+) PLUS 1' J = CONDENSATE TRAP SHOULD BE AT A DEPTH OF [1/2 ('H')] TO OVERCOME NEGATIVE STATIC PRESSURE OF FAN EXTEND TO ROOF WHERE EXISTING IS PIPED TO ROOF DRAIN OR REO'D BY LOCAL AUTHORITIES. SECTION TO DRAIN ONLY MAY BE PVC MIN - 4' MAX MIN, 12'x18'x2' THICK CONCRETE SPLASH BLOCK 24'x24- HUMPNE ROOF PAD SPUD BACK GRAVEL MASTIC TO ROOF 2 RTU CONDENSATE DETAIL III SCALE NONE CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O c 317.288 .0681 F :: 317.288.0753 DRAWN BY: JES CHECKED BY: HIGH OT/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 871 7954 tesengineering.com NGEM T =�N 767�_ �� ••.• STATE OF :'4/� ' F••'•�ND I AN / /SSi/C N AII11O'? \ THIS DRAWING AND THE IDEAS, [DESIGNS AND CONCEM CONTAINED HEREIN ARE THE E(CLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO GE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. © (APYW.'HT2016, C RANAF I FT WESTON POINTE RESTAURANT WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA SHELL MECHANICAL LEGEND, DETAILS & ABBREVIATIONS CARMEL RESUBtl PERMIT SET ADDENDUM 1 ADDENDUM 2 PERMIT SET 170026 Woe I