P0.1 Plumbing Details
PLUMBING ABBREVIATIONS NOTPLUMBING (ALL ABBREVIATIONS $DRA SYMBOLS WINGS NECESSARILY USED ON DRAWINGS) (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS) A Al AMPERE RW KILOWATTS Ali ABOVE II KILOWATT-HOUR A ABOVE CEILING ELBOW UP N ADJUSTABLEFIN[ LBS, k LOUNGE MC AFC ABOVE FINISHED CEILING LP LOW PRESSURE -0 ELBOW GOWN AFF ABOVE FINISHED FLOOR LOUT LEAVING WATER TEMPERATURE AEG ABOVE FINISHED GRADE VALVE IN DROP ANS ABOVE MAX ANSI AN Ill ARCHITEC NAARC STANDARDS INSTITUTE MR 1000 T 1000 BTU PER HOUR ARCH ARCHITECT ARCHITECTURAL SOCIETY NO MECHANICAL CONTRACTOR DIRECTION OF FLOW ASIME ASSY OF �ECHANICAL ENGRS MEO ASSEMBLN ASSEMBLY MCA MINIMUM CIRCUIT PAIPACITY pl TEE OUTLET UP ASTM AAN SOCIETY OF TESTING 8 MATLS MECH MFR MECHANICAL MANUFACTURER AU% ARYHALIDE�T AUXILIARY MIN MANHOLE, METAL TEE OUTLET DOWN AWS AEERICAN WELDING SOCIETY MIN MINIMUM AWNA PMiRICAN WATER WORKS ASSOC. M)CP MTD MAXIMUM OVER CURRENT PROTECTION MOUNTED ------~ UNION B/F BELOW FLOOR BLDG BUILDING BALL VALVE BOP B070M OF PIPE N/A NOT APPLICABLE BTU BOTTOM OF N.C. NORMALLY CLOSED �� GATE VALVE BTU UNIT BR ITISH 1HERMPI UNIT THERMAL NEC NATIONAL ELECTRICAL CODE NEMA NFPA NATIONAL ELECTRICAL SEE'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. OS&Y VALVE CA COMBUSTION AIR CFH CUBIC FEET PER HOUR NIC NOT IN CONTRACT W CALIBRATED BALANCING VALVE CIRC CIRCULATING N.O. NORMALLY OPEN CL CENTERLINE NTS NOT TO SCALE CLG CEILING CHECK VALVE CO CLEANOUT O/H OVERHEAD CONN CONNECT CONNECTION DO CENTER PRESSURE REDUCING VALVE COP CLEANI PLUG OD ON DIAMETER COL COLUMN OPNG OPENING BUTTERFLY VALVE GTE CONNECT TO EXISTING ORD OVERFLOW ROOF DRAIN CW DOMESTIC COLD WATER OS&Y OUTSIDE STEM AND YOKE $F HOSE BIBB °C DEGREES CELSIUS OSHA OCCUPATIONAL SAFETY &HEALTH ADMIN. SAN SANITARY PIPING D DEPTH PD PRESSURE OOP DEG DEGREES PH, 0 PHASE y SANITARY VENT PIPING CIA (OR 0) DIAMETER PIV POST INDICATOR VALVE —Rj STORM PIPING AO DIM DIMENSION PLBG PLUMBING DISC DISCONNECT PSI POUNDS PER SQUARE INCH $T STORM PIPING UO DN DOWN PRV PRESSURE RELIEF VALVE DOM DOMESTIC CO OVERFLOW DRAIN PIPING US DOWNSPOUT BD ROOF DRAIN — COLD WATER (CW) PIPING DWG DRAWING RECIRC RECIRCULATE REINF REINFORCING, REINFORCED — — — HOT WATER IN) PIPING EA EC E TRICAL CONTRACTOR ELECTRICAL REAL RED RELOCATEDHOT REQUIRED WATER RECIRCULATION (ENST ELEV ELEVATION REV REVISION, REVISE G NATURAL GAS PIPING ELEC ELECTRICAL RE% REMOVE EXISTING ENCL ENCLOSURE RPM REVOLUTIONS PER MINUTE ] CAP ON END LINE EQUIP EQUIPMENT RR REMOVE AND RELOCATE SIR EYW EXISTING TO REMAIN ENTERING WATER TEMPERATURE Sol RAIN WATER CONDUCTOR S. M GAS VALVE SAN SO SANITARY STORM DRAIN EX EXISTING 'kkl- T&P RELIEF VALVE ROD FLOOR CLEANOUT ED FLOOR DRAIN SECT SECTION FF FINISHED FLUOR SF SQUARE FEET SQUARE FOOT — — — — — — — - �l WALL CLEANOUT OR CLEANOUT PLUG SIR STATIC PRESSURE FLA FULL LOAD AMPS SPEC SPECIFICATION FLOOR CLEANOUT FLEX FLEXIBLE CO SQUARE �^, FP FIRE PROTECTION ST ORM WATER STORM Fi FOOT, FEET STD STANDARD PRESSURE GAUGE WITH GAUGE COCK FW FILTERED WATER SURF SURFACE nIII °F DEGREES FAHRENHEIT SUSP SUSPEND — — — ( THERMOMETER WATER METER G GAS TON TOTAL DYNAMIC HEAD GA GAUGE TSTAT THERMOSTAT GAL GALLON TYP TYPICAL — — — GAS REGULATOR GALV GALVANIZED U/F UNDERFLOOR GC GENERAL CONTRACTOR GPD GALLONS PER DAY ® FLEXIBLE CONNECTION M/G UNDERGROUND GPH GALLONS PER HOUR U/S UNDERGROU GPM GALLONS PER MINUTE ILL UNDERWRITERS LABORATORIES, INC. —� PIPE FLANGE GIN GREASE WASTE UON UNLESS OTHERWISE NOTED ----- THERMOMETER WELL VENT H HEIGHT HD HEAD HUB CRAW VA VALLVE �:Q FLOOR SINK IFS) HP HIS HORSEPOWER, HEAT PUMP HEATING VAC VACUUM 7J FLOOR GRAIN WITH P-1RPP HTR HEATER VTR VENT THROUGH ROOF HVAC HEATING, VENTILATING & A/C W WA75 WIDTH EJ p PLUMBING FIXTURES HW DOMESTIC HOT WATER W/ WITH HOUR DOMESTIC RECIRCULATED HOT WATER W/o WITHOUT ® GAS MAN IFOW LOCATION HYD HYDRANT WC WATER COLUMN HZ HERTZ DOUBLE CHECK BACKFLOW PREVENTS DCV TO INSIDE DIAMETER ® DOMESTIC WATER RISER IS INVERT ELEVATION IN INCH, INCHES POINT OF NEV CONNECTION IN WC INCHES OF WATER COLUMN TO EXISTING PIPING OR SYSTEM RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel �VT�BM'�G*VAWML DATE: \ 08/19/19 COPPER TOP. FINISH AS SELECTED BY ARCH. t j BRASS PLUG AS REQUIRED FITTING OR EXTENSION _ SANITARY OR STORM FLUSH WITH FINISHED FLOOR FINISHED FLOOR �OR WALK IOKYUI=Y:OIeB 1 FLOOR CLEANOUT DETAIL P-0.1 I SCALE: NONE GAS FIRED EQUIPMENT ON ROOF VERIFY GAS LINE PRESSURE. PROVIDE GAS PRESSURE REGULATOR IF REQUIRED GAS COCK GAS SERVICE ON ROOF. FOR TO PLANS FOR CONTINUATION AND SIZES 60 DIRT LEG 2 GAS CONNECTION DETAIL - ROOFTOP UNITS Ill I SCALE: NONE B-LINE C-PORT 80 % 18' % 112 VALK PAD AT ACH SUPPORT R PIPE STRAP NOTES 1. INSTALLATION SHALL BE PER MANUFACTURERS RECOMMENDATIONS. 2. WOOD BLOCK SUPPORTS ARE NOT ACCEPTABLE 3. BLACK IRON PIPING SHALL BE PAINTED; (PAINTING OF GALVANIZED PIPING IS NOT REO'D) 3 GAS SUPPORT ON ROOF DETAIL P-0.1 SCALE: NONE 1-1120 WATTS SERIES LF919 REDUCED PRESSURE GASKFLOW PREVENTER WITH STRAINER. PROVIDE AIR GAP AND PIPE TO FLOOR SINK. L' NDN RISING STFM (TYP) 1-1/20 DOMESTIC WATER-- STRAINER SUPPLY 1-1/2' FROM METER WALL SUPPORTS FLOG SINK FINISHED FLOOR 4 INCOMING SERVICE P-0.1 SCALE: NONE PLUMBING FIXTURE AND EQUIPMENT SCHEDULE CONNECTION SIZE TAG FIXTURE TYPE ME MODEL No. DESCRIPTION SAN VENT HW CW SEE ADJUSTABLE CLEANOUT, IF FLOORS ME TILED OR TERRAZZO PROVIDE WITH FCO FLOOR CLEAN OUT PLANS - - U.N. SMITH 4000 SERIES NICKEL BRONZE FINISH, IF FLOORS ARE CARPETED PROVIDE WITH RECESSED TOP. CLEANOUTS ARE TO BE FLUSH WITH FINISHED FLOOR. RPBFP REDUCED PRESSURE 1-1/2' WATTS LF919 LEAD FREE RPZ, BRONZE. MAXIMUM PRESSURE 175 LEE. MOUNT IN ACCESSIBLE BACKFLOW PREVENTER - - LOCATION, ON UNISTRUT AND STANCIONS/SHELF. AO 2• C.I. ELBOW O 2• WALL PLATE © 2. 45 DEG. GALV. ELBOW FROM MAIN DRAIN 1' 0" Min. 5 FIRE RISER MAIN DRAIN DETAIL P-0.1 SCALE: NONE AO 10 C.I. ELBOW FROM INSPECTION TEST © 1' GLOBE VALVE WITH CONNECTIO INSPECTORS TEST SIGN © 1' WALL PLATE QD 1• N5 DEG. GALV. ELBOW EO SMOOTH BORE CORROSION RESISTANT OUTLET GIVING FLOW EQUIVALENT TO ONE FAmax. C SPRINKLER (AIM PER D 7'-0_ ARCHITECTURAL DIRECTION) EO 1'-0- Min. 6 INSPECTORS TEST FOR WET PIPE SYSTEMS P-0.1 I SCALE: NONE REFER TO PLAN ON THIS DRAWING FOR FIRE MANIFOLD RISER PIPING CONTINUATION VALVE ASSEMBLY FLOW SWITCH`, INSPECTION TEST CONNECTION. SEE DETAIL ON THIS sxEEr MAIN DRAIN. 4- TO FDO SEE DETAIL ON THIS SHEETS 1 — CHECK VALVE DCBFP AME$ COLT SERIES G50OBFG DOUBLE CHECK VALVE WITH OS&Y BY FIRE PROTECTION CONTRACTOR BY OTHERS FLOOR DETAIL NOTES 1. DETAIL IS SHOWN FLAT FOR CLARITY. REFER TO SPRINKLER PLANS FOR CONFIGURATION. 2. ROUTE ALL DRAIN PIPING FROM EQUIPMENT TIGHT TO WALLS. 3. INSTALL EQUIPMENT BASED ON MANUFACTURER'S RECOMMENDATIONS FOR CLEARANCES. 4. THE GENERAL CONTRACTOR TO COORDINATE THE FLOOR PENETRATIONS FOR ALL OF THE INCOMING WATER AND VERIFY WITH ALL CONTRACTORS THE OVERALL EQUIPMENT LENGTHS TO ALLOW FOR PROPER MAINTENANCE AND INSTALLATION CLEARANCES. 7 FIRE RISER DETAIL P-0.1 SCALE: NONE CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O c 3I7.288 .068I F :: 317.288.0753 DRANK BY: XXX CHECKED BY: XXX OT/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 871 7954 tesengineering.com N(:,EM TX e:6 =� N 767 ci�_ T�.• STATE OF i 41� / S1S1/0 NAI. IIII��? \ THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE D(CLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. © wv00wT2016. CURMNneomaroae WESTON POINTE RESTAURANT WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA PLUMBING DETAILS AND SCHEDULES CARMEL RESUBLI PERMIT SET ADDENDUM 1 ADDENDUM 2 PERMIT SET 170026 P-0. I