HomeMy WebLinkAbout(07) LS3-101LEGEND Fa BUILDING CODES REFERENCED 2014 INDIANA BUILDING CODE (20121BC, 1ST PRINTING) 2012 INDIANA PLUMBING CODE 2014 INDIANA MECHANICAL CODE (20121MC, 1ST PRINTING) 20141NDIANA FIRE CODE (20121FC, 1ST PRINTING) 2009 INDIANA ELECTRICAL CODE (NFPA 70-2008) ASHRAE 90.1-2007 EDITION ANSI At 17.1-2009 DESCRIPTION WOOD FRAMED CONSTRUCTION WITH A COMBINATION OF MASONRY, CEMENT FIBER BOARD AND EXTERIOR INSULATED FINISH SYSTEM. STEEL FRAMED CONSTRUCTION WITH SPRAY -APPLIED FIRE -PROOFING ON FIRST FLOOR. TYPE R-2 PRIMARY OCCUPANCY TYPE V-A CONSTRUCTION FOUR STORY APARTMENT BUILDING BUILDING AREA BUILDING 3 FIRST FLOOR - SECOND FLOOR - THIRD FLOOR - FOURTH FLOOR- TOTAL - RELEASED FOR CONSTRUCTION AUTOMATIC FIRE SUPPRESSION SYSTEM BUILDING IS REQUIRED TO HAVE AND IS PROVIDED THROUGHOUT W ITH AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R AND IBC 903.3.1.2. FIRE EXTINGUISHERS FIRE EXTINGUISHER CABINETS AT 75' MAX TRAVEL. FIRE ALARM SYSTEM COMPLETE FIRE ALARM SYSTEM REQUIRED AND PROVIDED IN ACCORDANCE WITH NFPA 72 AND IBC. PROVIDE VISUAL NOTIFICATION (STROBES) IN ACCESSIBLE UNITS IN ACCORDANCE WITH NFPA 72. [d•] 9 i �7_\ /_71: Y I q:1: GV [O:Id E139 R �] I: [•IdO �] i OCCUPANCYGROUP SECTION 310.3 OCCUPANCY R2 OCCUPANCY: (RESIDENTIAL, APARTMENT) M MERCANTILE RETAIL B BUSINESS (OFFICES) SEPARATED MIXED USE PER IBC 508: OCCUPANCY SEPARATIONS INDICATED ON FLOOR PLAN 12,039 GSF SECTION 510- SPECIAL PROVISIONS 12,523 GSF HORIZONTAL SEPARATIONS MUSTCOMPLY WITH THE 12,523 GSF FOLLOWING: • 3-HR FIRE RESISTANCE RATING 12,523 GSF THE BUILDING BELOW IS NOT GREATER THAN ONE 49,608 GSF STORYABOVE GRADE • THE BUILDING BELOW IS OF TYPE 1A CONSTRUCTION • ANY SHAFT, STAIRWAYS, RAMP, OR ESCALATOR MUST BE IN A 2-HOUR RATED ENCLOSURE • THE BUILDING BELOW IS PROTECTED BY AN AUTOMATIC FIRE SPRINKLER SYSTEM, PER NFPA 13 SECTION 510.9 MULTIPLE BUILDINGS ABOVE A HORIZONTAL ASSEMBLY SHALL BE REGARDED AS SEPARATE BUILDINGS. BUILDING 3 EQUIPPED WITH NFPA 13 SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 TABLE601 CONSTRUCTION TYPE: V-A SECTION 708 FIRE BLOCKING REQUIRED SECTION 718.3.2 DRAFTSTOPPING REQUIRED IN FLOORS, AT EVERY SLEEPING UNIT SECTION 718.4.2 DRAFTSTOPPING IN ATTICS: REQUIRED, EVERY 3,000 SF SECTION 903.2.8 GROUP R- AUTOMATIC SPRINKLER SYSTEM NFPA I3R REQUIRED. SECTION 1023 STAIRWAYS- ENCLOSURE MINIMUM OF 2HR RATING SECTION SMOKEPROOF ENCLOSURES- NOT RED. WHERE TOP FLOOR IS 1023.11 LESS THAN 75 FT ABOVE FIRE DEPARTMENT ACCESS. (FLOOR LEVEL OF FOURTH FLOOR IS 37'-0" CONCEALED SPACES IBC 718 AND NFPA 13 A. FIREBLOCKING: REQUIRED, BOTH VERTICAL AND HORIZONTAL 10' INTERVALS BEHIND TRIM FINISHES. FIRE BLOCKING SHALL CONSIST OF ONE OF THE FOLLOWING: APPROVED NONCOMBUSTIBLE MAT 2" OR (2) 1" LUMBER WIBROKEN LAP JOINTS, 1 23/32" WOOD STRUCTURAL PANEL W/JOINTS BACKED BY 23/32" STRUCTURAL PANEL OR 2X LUMBER. B. DRAFTSTOPPING IN FLOORS: PER IBC 718.3. C. DRAFTSTOPPING IN ATTIC: PER IBC 718.4.2. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES A. REFER TO SECTION 714 EXIT SIGNS S EMERGENCY LIGHTING EXIT SIGNS PROVIDED PER IBC 1013, INTERNAL BATTERY BACKUP. FLOOR -LEVEL EXITS SIGNS PROVIDED PER IBC 1013.2. MEANS OF EGRESS ILLUMINATION AND EMERGENCY LIGHTING PROVIDED PER IBC 1008. ELEVATOR REQUIRED TO MEET ASME At 7.1 EXIT 8 0.2" 32 7n IA" z SECOND FLOOR LIFE SAFETY PLAN A8-201 SCALE: 3/32" = 1'-0" STAIR B 32 mn AW MEANS OF EGRESS BUILDING 3 REQUIREMENT REQUIRED PROVIDED NUMBER OF EXITS 2 PER FLOOR 2 PER FLOOR STAIR WIDTH 44"MIN 48"WIDTH PROVIDED CORRIDOR WIDTH 44" MIN 60" MIN EGRESS DOOR SIZE 32" MIN 32" MIN PROVIDED TABULAR OCCUPANT LOAD, BUILDING 3 (IBC 1004.1.2) FLOOR OCC. TYPE AREA (SF) FACTOR (SF/PERSON) OCC. LOAD (PERSONS) FIRST MERCANTILE 12,039 SF 1/60 GROSS 201 SECOND RESIDENTIAL 12,435 SF 1/200 GROSS 63 MECHANICAL 88 SF 1/300 GROSS 1 THIRD RESIDENTIAL 12,435 SF 1/200 GROSS 63 MECHANICAL 88 SF 1/300 GROSS 1 FOURTH RESIDENTIAL 12,435 SF 1/200 GROSS 63 MECHANICAL 88 SF 1/300 GROSS 1 BUILDING TOTAL I I 1 1 393 10 EXIT 7 0.2" 32 l70 T 34" FIRE RESISTIVE RATINGS ( TABLE 601 ) STRUCTURAL ELEMENT F.R. RATING F.R. RATING DESIGN NUMBER PER CODE PER DESIGN BEARING WALLS (V-A) EXT. WALLS (112) 1 HOUR 1 HOUR U.L. #U356 INT. WALLS 1 HOUR 1 HOUR U.L. #U305 CORRIDOR WALLS (112) 30 MIN 1 HOUR U.L. #U311 OPENING PROTECTION 20 MIN 20 MIN GUESTROOM SEPARATION 1 HOUR 1 HOUR U.L #U311 OPENING PROTECTION 45MIN 60 MIN STAIR (INT. WALLS) 2 HOUR 2 HOUR U.L #U301 STAIR (EXT. WALLS) 1 HOUR 1 HOUR U.L #U356 OPENING PROTECTION 90 MIN 90 MIN ELEVATORS 2 HOUR 2 HOUR U.L.#U906 OPENING PROTECTION 90 MIN 90 MIN --- CEILING - - --- STORAGE,TIECH 1 HOUR 1 HOUR U.L#U305 FLOOR -ABOVE RETAIL 1 HOUR 1 HOUR U.L. #G801 FLOOR - CEILING 1HOUR 1HOUR U.L.#L521 ROOF - CEIUNG cQ STAIR ROOF - CEIUNG 1HOUR 1HOUR U.L.#P522 SHAFT 1 HOUR 1 HOUR U.L. #U305 STAIR A 0.3" 32 160 48" 11 EGRESS ELEMENT OCCUPANTS SERVED (REQUIRED) EGRESS WIDTH (PROVIDED) OCCUPANTS SERVEC (PROVIDED) REQUIRED ELEMENT WIDTH 1 HOUR RATED w w FIRE BARRIER 2 HOUR RATED w w w FIRE BARRIER EXIT EXIT SIGN - SEE ELECTRICAL SPACE AREA FUNCTION OF SPACE BUSINESS 6000 SF B OCCUPANCY 1 / 100 60 2 CLASSIFICATION NUMBER OF REQUIRED EXITS NUMBER OF OCCUPANTS REQUIRED S.F. PER OCCUPANT TRAVEL DENOTES EXIT DISTANCE ROUTE 100' - 6" ♦��GEEDGEND 4 L START DENOTES EXIT POINT DISCHARGE SEMI -RECESSED PORTABLE FIRE EEL EEL EXTINGUISHER CABINETWITH PORTABLE FIRE EXTINGUISHER PER NFPA 72 AS SELECTED BY LOCAL FIRE MARSHALL. REFER TO DETAIL 10/A-602. FE WALL MOUNTED PORTABLE FIRE EXTINGUISHER PER NFPA 72 AS SELECTED BY LOCAL FIRE MARSHALL. W®®LPERT ARCXIIELTUREj1eNGINEEWNGjGEGSPATILL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 U J J Q 0 0 sE CID Q Issuances: NEW Mcm"M DATE 0 Issued For Building 3 Reviea 10/12/18 1 Issued For Building 3Permit 06/10/19 Prom. No.: 074904 Date: 10/12/18 Sheet Name: FIRST AND SECOND FLOOR LIFE SAFETY PLANS Subject to compliance with all regulations of State and Local Codes City of Cannel /� �N�1 10300:aUMASL DATE: 10/31/19 FIRST FLOOR LIFE SAFETY PLAN SCALE: 3/32" = 1'-0" LS3=101