HomeMy WebLinkAbout(07) LS3-1022 3 0 5 0 7 ii R BUILDING CODES REFERENCED 2014 INDIANA BUILDING CODE (2012 IBC, EST PRINTING) 2012 INDIANA PLUMBING CODE 2014 INDIANA MECHANICAL CODE (20121MC, 1ST PRINTING) 2014 INDIANA FIRE CODE (20121FC, EST PRINTING) 2009 INDIANA ELECTRICAL CODE (NFPA 70-2008) ASHRAE 90.1-2007 EDITION ANSI All7.1-2009 DESCRIPTION WOOD FRAMED CONSTRUCTION WITH A COMBINATION OF MASONRY, CEMENT FIBERBOARD AND EXTERIOR INSULATED FINISH SYSTEM. STEEL FRAMED CONSTRUCTION WITH SPRAY -APPLIED FIRE -PROOFING ON FIRST FLOOR. TYPE R-2 PRIMARY OCCUPANCY TYPE V-A CONSTRUCTION FOUR STORY APARTMENT BUILDING BUILDING AREA BUILDING 3 FIRST FLOOR - SECOND FLOOR - THIRD FLOOR - FOURTH FLOOR- TOTAL - RELEASED FOR CONSTRUCTION AUTOMATIC FIRE SUPPRESSION SYSTEM BUILDING IS REQUIRED TO HAVE AND IS PROVIDED THROUGHOUT WITH AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R AND IBC 903.3.1 2. FIRE EXTINGUISHERS FIRE EXTINGUISHER CABINETS AT 75' MAX TRAVEL. FIRE ALARM SYSTEM COMPLETE FIRE ALARM SYSTEM REQUIRED AND PROVIDED IN ACCORDANCE WITH NFPA 72 AND IBC. PROVIDE VISUAL NOTIFICATION (STROBES) IN ACCESSIBLE UNITS IN ACCORDANCE WITH NFPA 72. CODE DATA -INTERNATIONAL BUILDING CODE OCCUPANCY GROUP SECTION 310.3 OCCUPANCY R2 OCCUPANCY; (RESIDENTIAL, APARTMENT) M MERCANTILE (RETAIL) B BUSINESS (OFFICES) SEPARATED MIXED USE PER IBC 508; OCCUPANCY SEPARATIONS INDICATED ON FLOOR PLAN 12,039 GSF SECTION 510- SPECIAL PROVISIONS 12,523 GSF HORIZONTAL SEPARATIONS MUST COMPLYWITH THE 12,523 GSF FOLLOWING: " 3-HR FIRE RESISTANCE RATING 12.523 GSF • THE BUILDING BELOW IS NOTGREATER THAN ONE 49,608 GSF STORYABOVE GRADE • THE BUILDING BELOW IS OF TYPE 1A CONSTRUCTION • ANY SHAFT, STAIRWAYS, RAMP, OR ESCALATOR MUST BE IN A 2-HOUR RATED ENCLOSURE • THE BUILDING BELOW IS PROTECTED BYAN AUTOMATIC FIRE SPRINKLER SYSTEM, PER NFPA 13 SECTION 510.9 MULTIPLE BUILDINGS ABOVE A HORIZONTAL ASSEMBLY SHALL BE REGARDED AS SEPARATE BUILDINGS. BUILDING 3 EQUIPPED WITH NFPA 13 SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 TABLE 601 CONSTRUCTION TYPE: V-A SECTION 708 FIRE BLOCKING REQUIRED SECTION 718.3.2 DRAFTSTOPPING REQUIRED IN FLOORS, AT EVERY SLEEPING UNIT SECTION 718.4.2 DRAFTSTOPPING IN ATTICS: REQUIRED EVERY 3,000 SF SECTION 903.2.8 GROUP R- AUTOMATIC SPRINKLER SYSTEM NFPA I3R REQUIRED. SECTION 1023 STAIRWAYS- ENCLOSURE MINIMUM OF 2HR RATING SECTION SMOKEPROOF ENCLOSURES- NOT RED. WHERE TOP FLOOR IS 1023.11 LESS THAN 75 FTABOVE FIRE DEPARTMENT ACCESS. (FLOOR LEVEL OF FOURTH FLOOR IS 37'-0" CONCEALED SPACES IBC 718 AND NFPA 13 A. FIREBLOCKING: REQUIRED, BOTH VERTICALAND HORIZONTAL lV INTERVALS BEHIND TRIM FINISHES. FIRE BLOCKING SHALL CONSIST OF ONE OF THE FOLLOWING: APPROVED NONCOMBUSTIBLE MAT 2" OR (2) 1"LUMBER W/BROKEN LAP JOINTS, 1 23(32" WOOD STRUCTURAL PANEL W/JOINTS BACKED BY 23/32" STRUCTURAL PANEL OR 2X LUMBER. B. DRAFTSTOPPING IN FLOORS: PER IBC 718.3. C. DRAFTSTOPPING IN ATTIC: PER IBC 718.4.2. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES A. REFER TO SECTION 714 EXIT SIGNS 8 EMERGENCY LIGHTING EXIT SIGNS PROVIDED PER IBC 1013, INTERNAL BATTERY BACKUP. FLOOR -LEVEL EXITS SIGNS PROVIDED PER IBC 1013.2. MEANS OF EGRESS ILLUMINATION AND EMERGENCY LIGHTING PROVIDED PER IBC 1008. ELEVATOR REQUIRED TO MEET ASME A17.1 BUILDING HEIGHT AND AREA BUILDINGS 3 REQUIREMENT ALLOWABLE ACTUAL NUMBER OF STORIES -TABLE 504.4 4 STORIES W SPRINKLER 4 STORIES W SPRINKLER AREA- TABLE 506.2 21,000 SF PER FLOOR 19,465 SF FIRST FLOOR HEIGHT TABLE 504.3 60' W SPRINKLER 48'.0" CORRIDOR WIDTH 44"MIN 60 'MIN EGRESS DOOR SIZE 32" MIN 32" MIN PROVIDED MEANS OF EGRESS BUILDING 3 REQUIREMENT REQUIRED PROVIDED NUMBER OF EXITS 2 PER FLOOR 2 PER FLOOR STAIRWIDTH 44"MIN 48"WIDTH PROVIDED CORRIDOR WIDTH 44"MIN 60"MIN EGRESS DOOR SIZE 32" MIN 32" MIN PROVIDED TABULAR OCCUPANT LOAD, BUILDING 3 (IBC 1004.1.2) FLOOR OGG. TYPE AREA SF) FACTOR (SF/PERSON) OCC.LOAD (PERSONS) FIRST MERCANTILE 12.039 SF 1/60 GROSS 201 SECOND RESIDENTIAL 12.435 SF 1/200 GROSS 63 MECHANICAL 88 SF 1/300 GROSS 1 THIRD RESIDENTIAL 12.435 SF 1/200 GROSS 63 MECHANICAL 88 SF 1/300 GROSS 1 FOURTH RESIDENTIAL 12.435 SF 1/200 GROSS 63 MECHANICAL 88 SF 1/300 GROSS 1 BUILDING TOTAL I 1 1 393 EXIT 8 0.2" 32 170 34" FOURTH FLOOR LIFE SAFETY PLAN SCALE: 3/32" = 1'-0" FIRE RESISTIVE RATINGS (TABLE 6011 STRUCTURAL ELEMENT F. R. RATING F.R. RATING DESIGN NUMBER PER CODE PER DESIGN BEARING WALLS (V-A) EXT. WALLS (R2) 1 HOUR 1 HOUR U.L. #U356 INT. WALLS 1 HOUR 1 HOUR U.L. #U305 CORRIDOR WALLS (R2) 30 MIN 1 HOUR U.L. #U311 OPENING PROTECTION 20 MIN 20 MIN --- GUESTROOM SEPARATION 1 HOUR 1 HOUR U.L. #U311 OPENING PROTECTION 45 MIN 60 MIN STAIR (INT. WALLS) 2 HOUR 2 HOUR U.L. #U301 STAIR (EXT. WALLS) 1 HOUR 1 HOUR U.L. #U356 OPENING PROTECTION 90 MIN 90 MIN --- ELEVATORS 2HOUR 2 HOUR U.L. MI906 OPENING PROTECTION 90 MIN 90 MIN --- CEILING - - --- STORAGE/MECH 1 HOUR 1 HOUR U.L. #U305 FLOOR -ABOVE RETAIL 1HOUR 1HOUR U.L#G8O1 FLOOR-CEIUNG iHOUR iHOUR U.L #L521 ROOF - CEILING STAIR ROOF -CEILING 1HOUR 1HOUR U.L#P522 SHAFT 1 HOUR 1 HOUR U.L. MI305 EXIT 7 0.2" 32 170 34" STAIR A 0.3" 32 160 48" EXIT STAIR EXIT 8 STAIR B 0.2" 32 0311 32 32 32 170 34" 160 48" 0.2" 170 34" 01 '3160 48" I III� EGRESS ELEMENT OCCUPANTS SERVED (REQUIRED) EGRESS WIDTH PROVIDED OCCUPANTS SERVEC (PROVIDED) REQUIRED ELEMENT WIDTH 1 HOUR RATED � o � e � • � FIRE BARRIER 2 HOUR RATED � o • � o o � FIRE BARRIER EXIT EXIT SIGN - SEE ELECTRICAL LEGEND SPACE AREA FUNCTION OF SPACE BUSINESS 6000 SF B OCCUPANCY 1 / 100 60 2 CLASSIFICATION NUMBER OF REQUIRED EXITS NUMBER OF OCCUPANTS REQUIRED S.F. PER OCCUPANT TRAVEL DENOTES EXIT DISTANCE ROTE SIMM4 L START DENOTES EXIT POINT DISCHARGE SEMI -RECESSED PORTABLE FIRE EEL EXTINGUISHER CABINETWITH PORTABLE FIRE EXTINGUISHER PER NFPA 72 AS SELECTED BY LOCAL FIRE MARSHALL. REFER TO DETAIL 10/A-602. FE WALL MOUNTED PORTABLE FIRE EXTINGUISHER PER NFPA 72 AS SELECTED BY LOCAL FIRE MARSHALL. SALE WOOLPIENET ARCHITECTURE Ex INFER NO I GOES PAT IAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 N ffq u [0 IN 10 U � J•� J ��AVVVIIJJJ111 � �--, U � o a a� M In my U c `om CD c o C G U CO m n, �U Q Issuances: RW OESCNP ON MTE 0 Issued For Building 3 Reviev 10/12/18 1 Issued For Building 3Permit 06/10/19 Prom. No.: 074904 Date: 10/12/18 Sheet Name: THIRD AND FOURTH FLOOR LIFE SAFETY PLANS Subject to compliance with all regulations of State and Local Codes City of Cannel DATE: 10/31/19 THIRD FLOOR LIFE SAFETY PLAN SCALE: 3/32" = 1'-0" LS3=102