Loading...
HomeMy WebLinkAbout(08) S3-105u 3 4 5 7 L, W R m of Of M C O m Go v r ro E Q D_ D- Y - Y- 16.7 17 17 6 18 18.81 19 19.61 20 17.9 18.6 8'-91/4" i6'-6314" 6-51IT i i6'-6314" 4'-21/T'I 5'-5314" 16'-63/4" 9'-8114" 16'-6314" I �-1'-23/4" 20.6 21 Y 21.4, 21.7 22 216 5'-5" y.-3" T-6' 22.8 23 Y 24'-4" 5-8" I I I I I I I I 35'-9112" 24-0" 1124-01/T 1, 12'-01/4" 1, T-113/4" 1, 47-6 SIT 2T-0" 1, 6-75/8" 11 I Y I Y Y Y Y Y Y 16.7 17.9 18.8 19.61 20.11 20.3 22.1 22.7 23 BLDGw 3 = ROOF FRAMING PLAN "L LG 110 = I U ROOF FRAMING PLAN NOTES: 1. BEARING ELEVATION OF ROOF TRUSSES = 892'-8 1/8", TOP OF WOOD TRUSSES SHALL SLOPE PER ARCHITECTURAL PLANS AND SECTIONS. 2. ROOF SHEATHING, REF SHEET S3-001, UNLESS OTHERWISE NOTED ON PLAN. ROOF SHEATHING IS APPLIED PERPENDICULAR TO TRUSSES UNLESS OTHERWISE NOTED. SEE SHEET S3-201 FOR TYPICAL ROOF SHEATHING LAYOUT AND ATTACHMENT. 3. ROOF FRAMING MEMBERS ARE PRE-ENGINEERED PLATED ROOF TRUSSES TO BE SPACED AT 24. ON CENTER, UNLESS NOTED OTHERWISE. DOUBLE LINES INDICATE MULTIPLE PRE-ENGINEERED PARALLEL CHORD PLATED ROOF TRUSSES DESIGNED TO CARRY THE EFFECTIVE TRIBUTARY AREA LOADS. OTHER MEMBERS SIZES AND LAYOUTS ARE NOTED ON PLAN. 4. EXACT ROOF TRUSSNOIST LAYOUT AND DIMENSIONS ARE THE RESPONSIBILITY OF THE TRUSS FABRICATOR AND FRAMING SUBCONTRACTOR. ROOF TRUSSIJOIST LAYOUT SHALL BE COORDINATED WITH THE MECHANICAL, ELECTRICAL AND PLUMBING SUBCONTRACTORS PRIOR TO SUBMISSION OF ROOF TRUSS SHOP DRAWINGS, FABRICATION AND INSTALLATION TO ENSURE THE PROPOSED LAYOUT PROVIDES NECESSARY CLEARANCES FOR THE MECHANICAL, ELECTRICAL AND PLUMBING TRADE ELEMENTS, FIXTURES, DUCTING AND PIPING. 5. EXACT FRAMING LAYOUT SHALL BE COORDINATED WITH ALL OTHER TRADE SUBCONTRACTORS PRIOR TO INSTALLATION OR ITEMS INCLUDING BUT NOT UIMITED TO: ELECTRIC PANELS, ELECTRIC FIXTURES (INCLUDING CAN LIGHTS), FIRE EXTINGUISHER CABINETS, MEDICINE CABINETS, CONTROL JOINTS, DOOR FRAMING AND HVAC DUCTS/SOFFITS. IF THE LAYOUT IS CHANGED SUCH THAT THE LOADING ON HEADERSIBEAMS IS INCREASED, THE FRAMING SUBCONTRACTOR SHALL SUBMIT A REVISED SCHEDULE OF THOSE HEADERSMEAMS STAMPED BY AN ENGINEER REGESTERED IN THE STATE WHERE THE PROJECT IS LOCATED. 6. ROOF TRUSS DESIGN LOADS AND CONSTRUCTION REQUIREMENTS ARE PROVIDED IN GENERAL NOTES ON SHEET S3-001 AND S3-002 WITH SNOWDRIFTAND WIND UPLIFT DIAGRAMS PROVIDED ON SHEET S3-115. 7. SEE LOWER LEVEL FRAMING PLANS FOR WALL TYPES THAT PROVIDE THE WALL CONSTRUCTION INCLUDING HEADERS AND LINTEL WHERE OCCURS. 8. SEE ARCHITECTURAL DRAWINGS FOR ALL OPENINGS, LOCATIONS AND SIZES, TRUSS SUPPLIER SHALL PROVIDE SUPPLEMENTARY FRAMING, HEADER AND INCREASED CAPACITY REQUIREMENTS OF ADJACENT MEMBERS AS NECESSARY TO SUPPORT INTERRUPTED FRAMING FOR DESIGN LOADS. 9. TRUSS SUPPLIER SHALL PROVIDE ADDITIONAL FRAMING MEMBERS, SUPPLEMENTARY FRAMING, HEADERS OR MULTIPLE TRUSS OR HIGHER CAPACITY TRUSSES TO SUPPORT ROOF TOP MECHANICAL UNITS, SEE MECHANICAL DRAWINGS FOR SIZE, LOCATIONS, FOOTPRINTS AND WEIGHTS. 10. COORDINATE SIZE AND LOCATIONS OF ALL FLOOR OPENINGS WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. It. SEE THE WALL STUD SCHEDULE ON SHEET S3-501 FOR TYPICAL AND SPECIAL WALL FRAMING, DENOTED EW-1 AND CW-1. 12. SEE SHEET S3-201 FOR TYPICAL ROOF SHEATHING LAYOUTAND ATTACHMENT DETAIL. 13. HEADERS SHOWN ON FLOOR PLAN ARE FOR OPENINGS BELOW THE FLOOR AND SUPPORT THE FLOOR FRAMING SHOWNONPLAN. COORDINATE ELEVATIONS WITH ARCHITECTURAL DRAWINGS. 14. ALL CS14 STRAPS SHALL BE BY SIMPSON STRONG -TIE OR APPROVED EQUIVALENT. 15. THE NUMBER MARKED IN PARENTHESIS (XX) NEXT TO STRAPS INDICATES THE MINIMUM NUMBER OF FASTENERS FOR THAT SEGMENT OF THE SPAN. ALL FASTENERS SHALL BE SD SCREW #9x1 1/2" BY SIMPSON STRONG -TIE OR APPROVED EQUIVALENT. FASTENERS SHALL BE EQUALY SPACED ALONG THE SPAN OF THE STRAP. PROVIDE 2x BLOCKING UNDERNEATH THE STRAP AND INSTALL THE STRAP DIRECTLY BENEATH THE FLOOR SHEATHING. 16. ' DENOTES JACK STUDS. RELEASED FOR CONSTRUCTION 17. PROVIDE TRIPLE WALL BEARING STUDS AT EACH END OF ALL HEADERS CROSSING THE CORRIDOR. THE STUDS SHALL BE CONTINUOUS DOWN TO THE FOUNDATION OR STEEL LEVEL TO PROVIDE A COMPLETE LOAD PATH. Subject to compliance with all regulalions of State and Local Codes City of Camel NORTH _Y TOP CHORDS SLOPE OR - DEPTH OF TRUSS STEPS TO ACHIEVE ROOF SLOPE, PER ARCH. RT-1 ROOF TRUSS SCHEDULE MARK SIZE RT-1 DEPTH PER FABRICATOR -4x2 RT-2 DEPTH PER FABRICATOR -4x2 ROOF TRUSS PROFILES HEADER LEGEND: SEE SHEET S3.501 FOR HEADER SCHEDULE HL3-9.5M�.3 t# OF KING STUDS ADJACENT TO JACK STUDS # OF JACK STUDS UNDER EACH END OF HEADER HEADER SIZE - SEE HEADER SCHEDULE FOR ACTUAL SIZE NOTE: ALL JACK AND KING STUDS TO BE 2X SPRUCE PINE FIR NO 1/NO 2 74,WOOLPEUT MCNITECTNE IENGINEWINGIGECWATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E No. FE11700572 Issuances: nESM"M Prom. No.: 074904 Date: 10/12/18 A Sheet Name: BLDG. 3-ROOF FRAMING PLAN P*IRIRA DATE: 10/31/19