HomeMy WebLinkAbout(09) A3-4011
2
3
0
5
9
7
L,
0
R
0_ v o_ 1 1 M.
UNIT 1133•81 • TWO BEDROOMS
SCALE: 114" = 1'-0"
SHADED AREA INDICATES DROPPED CEILING -
5/8" GYP BD ON 2x4'S (LLV) AT 24" OC TIGHT TO
UNDERSIDE OF RATED CEILING ASSMEBLY
U
5'- 1 1/8"
BEDROOM
E
91_ 1 vP" 7'_ 1n vv"
5 , UNIT B3•A1 • ONE BEDROOM W/ DEN
M02 SCALE: 1/4" = 1'-0"
UNIT B3•A3 • ONE BEDROOM
■
k
GENERAL NOTES - INTERIOR FRAMING
1. ALL MATER IALS AND WORK SHALL BE FU RN ISHED AND INSTALLED IN
WORKMANSHIP -LIKE MANNER IN STRICT ACCORDANCE WITH ALL
PREVAILING LOCAL, STATE, AND NATIONAL BUILDING CODES.
2. CONTRACTORS SHALL STORE, HANDLE, AND INSTALLALL PRODUCTS AND
ASSEMBLIES PER THE MANUFACTURER'S INSTRUCTIONS,
RECOMMENDATIONS, AND PROCEDURES IN ORDER TO ENSURE THE
MANUFACTURER'S WARRANTY IS VALIDATED.
3. SUB -CONTRACTORS SHALL VERIFYALL DIMENSIONS.
4. ALL DIMENSIONS ARE GIVEN FROM STUD TO STUD, UNLESS OTHERWISE
NOTED.
5. STUD DIMENSIONS ARE 31/2" OR 5 1/2" UNO.
6. ALL EXTERIOR WALLS ARE TO BE 2x6 STUDS. REFER TO STRUCTURAL FOR
OTHER LOCATIONS.
7. UNIT LAYOUT IS AS SHOWN ON'/." SCALE PLANS. FOR BUILDING
DIMENSIONS, REFER TO 1/8" SCALE OVERALL BUILDING FLOOR PLANS.
8. GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL,
PLUMBING, AND ELECTRICAL CONTRACTOR S FOR ALL RESPECTIVE
OPENINGS, AS REQUIRED, INCLUDING MAINTAINING FIRE RATED
ASSEMBLIES.
9. FOR MATERIALS AND FINISHES, REFER TO FINISH SCHEDULES ON THIS
SHEET.
10. TYPE'X" 5/8" THICK GYPSUM BOARD SHALL BE USED AT RATED WALL
CONSTRUCTION INCLUDING BEARING WALLS. TYPE "C" 5/8" GYPSUM BOARD
SHALL BE USED AT CEILINGS. REFER TO UL ASSEMBLIES.
11. ALL CEILING ASSEMBLIES ARE TO BE MIN. 1 HOUR FIRE RATED
CONSTRUCTION WITH DAMPERS AT ALL DUCT PENETRATIONS. REFER TO
MECHANICAL DRAWINGS.
12. ALL WALLS WHICH FORM PERIMETERS OF DWELLING UNITS AND ALL LOAD
BEARING WALLS SHALL BE MIN. 1 HOUR FIRE RATED UL-U305 OR UL-U314
ASSEMBLY. NON -LOAD BEARING INTERIOR PARTITIONS WITHIN DWELLING
UNITS DO NOT REQUIRE FIRE RATING.
13. USE MIN.3/8"OSB AT ALL ATTIC DRAFT STOPS.
14. REFER TO STRUCTURAL FOR ALL WINDOW AND DOOR HEADER SIZES.
15. CONTRACTOR TO PROVIDE: (1) 12" WOOD SHELF AND ROD IN ALL ENTRY
CLOSETS, (1) 12" WOOD SHELF, ROD, AND VERTICAL SHELVING IN BEDROOM
CLOSETS, (1) 12" WOOD SHELF AT LAUNDRY, (5) 12" DEEP WOOD SHELVES IN
LINEN CLOSETS, AND (5) 18" DEEP WOOD SHELVES IN PANTRY. PROVIDE
SHELVES IN BATH ROOM AS SHOWN. REFER TO DRAWINGS.
16. REFER TO STRUCTURAL DRAWINGS FOR INTERIOR BEARING WALL MEMBER
SIZE AND SPACING.
17. FLOOR TOPPING TO BE 3/4" GYPCRETE 2000 OR APPROVED EQUAL.
CONTRACTOR TO ADJUST STAIR RISER HEIGHTS AND DOOR HEADER
HEIGHTS ABOVE SUB -FLOOR ACCORDINGLY.
18. CONTRACTOR TO PROVIDE PAPER FACED INSULATION FOR ALL EXTERIOR
WALLS. PROVIDE TYVEK VAPOR BARRIER ON ALL EXTERIOR WALLS.
19. ALL WALL AND CEILING GYPSUM BOARD TO BE SMOOTH FINISH COATING.
REFER TO FINISH SCHEDULE FOR SHEEN.
20. PROVIDE WASHER AND DRYER HOOKUPS IN ALL UNITS AS REQUIRED TO
MEET OR EXCEED APPLICABLE CODES.
21. DWELLING UNIT SEPARATION WALLS OF APARTMENT UNITS SHALL BE MIN.
ONE HOUR FIRE RATED CONSTRUCTION.
22. PROVIDE WOOD BLOCKING SUPPORTAS REQUIRED, INCLUDING, BUT NOT
LIMITED TO: ALL LOCATIONS FOR GRAB BARS IN ALL UNITS AND AT ALL
STAIR RAILS, SUPPORT FOR SHEATHING EDGES NOT ON FRAMING, KITCHEN
WALL CABINETS ON ALL FLOORS, AND AT TV WALL LOCATIONS.
23. PROVIDE R-13 (3'/z") MIN. ACOUSTIC BATT INSULATION IN ALL DWELLING
UNIT SEPARATION WALLS. IN CEILINGS PROVIDE R-13 (3 %") MIN. ACOUSTIC
BATT INSULATION AT LOCATIONS WHERE OCCUPIED SPACE ABOVE HAS A
HARD FLOOR SURFACE. PROVIDE R-19 (51/2") MIN. PAPER FACED THERMAL
BATT INSULATION IN EXTERIOR WALLS. PROVIDE R-30 (9") MIN. IN CEILING
ABOVE GARAGES. PROVIDE RJ8 (11") MIN. IN CEILING BELOW ROOF AREAS.
24. ALL LIVING UNITS SHALL BE CONSTRUCTED TO COMPLY WITH OBC
ADAPTABLE UNIT TYPE "B" REQUIREMENTS, UNLESS DESIGNATED ADA
ACCESSIBLE UNIT TYPE "A" IN UNITS LOCATIONS SHOWN.
25. PROVIDE CONTROL JOINTS IN CORRIDOR GYPSUM BOARD CEILING 30 FEET
O.C. WITH RESILIENT CHANNELS, TYPICAL.
26. STRUCTURAL MEMBERS SUPPORTING MORE THAN ONE FLOOR SHALL BE
INDIVIDUALLY PROTECTED BYAONE-HOUR FIRE RESISTANCE RATED
ASSEMBLY.
TYPE 'B' ACCESSIBLE UNIT
ALL UNITS NOT DESIGNATED AS TYPE W PER BUILDING FLOOR PLAN SHEETS A2-101
THRU A2-104B
1. PRIMARY ENTRANCE DOOR HARDWARE TO BE LEVER TYPE. LOCKING
MECHANISM TO BE ACCESSIBLE PUSH BUTTON TYPE PER ANSI 1003.5
2. ALL THRESHOLDS TO BE 1/2" MAXIMUM CHANGE IN LEVEL FROM TOP OF
THRESHOLD TO FINISHED FLOOR. PATIO SURFACE SHALL BE 4" MAXIMUM
BELOW FLOOR LEVEL OF ADJACENT INTERIOR SPACE
3. TOILET CENTERLINES SHALL BE I8"(MIN.) FROM WALL MEASURED FROM
FACE OF DRYWALL.
4. PRIMARY ENTRANCE DOOR SHALL BE 36" WIDE AND HAVE 18" (MIN.) PULL
SIDE CLEARANCE.
5. INTERIOR UNIT PASSAGE DOORS SHALL BE 34"WIDE (MIN.).
6. INSTALL BLOCKING FOR FUTURE GRAB BARS AT TOILETS AND TUBS
GENERAL NOTES - ACCESSIBILITY
ALL DWELLING UNITS SHALL COMPLY WITH THE FOLLOWING:
1. THE HEIGHT OF THE WATER CLOSET SHALL BE AT LEAST I5"AND NO MORE
THAN 19" MEASURED TO THE TOP OF THE TOILET SEAT.
2. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A BRAG BAR OR
HANDRAIL SHALL BE 1-1/4" TO 1-1/2".
3. THE STRUCTURAL STRENGTH OF GRAB BARS, BATH TUB SEATS FASTENERS
AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS
3.1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCES BY THE
MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250 LBF
SHALL BE LESS THAN THE ALLOWABLE STRESS OF THE MATERIAL
OF THE GRAB BAR OR SEAT.
3.2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE
APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE
SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SHEAR. IF
THE CONNECTION BETWEEN THE GRAB BAR AND ITS MOUNTING
BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY
RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES
SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, WHICH
SHALL NOT EXCEEDED THE ALLOWABLE SHEAR STRESS.
3.3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE
FROM THE APPLICATION OF 250 LBF SHALL BE LESS THAN THE
ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR
MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER
IS THE SMALLER ALLOWABLE LOAD.
3.4. TENSILE FORCE INDUCED IN FASTENER BY DIRECT TENSION
FORCE OF 250 LBF PLUS THE MAXIMUM MOMENT FROM THE
APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE
WITHDRAWAL AND THE SUPPORTING STRUCTURE.
3.5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
WOOLPERT
ARCHITECTURE Ex iNEEx NO I GOES PAT IAL
7635 Interactive Way
Suite 100
IS Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
F
Ill
b:
we
l]
110
U
�
J•�
J
�A
a--L
K
rUn
V I
�
c
(]
O
o
c
�
�
m
O
CU
M
m
€ t0
0
�r
my
U
cv
o c
co
N €
U
m
= U
Q Issuances:
RW
OESCmPTENI
MTE
0
Issued For Building 3 Revies
10/12/18
1
Issued For Building 3Permit
06/10/19
Prom. No.: 074904
Date: 10/12/18
Sheet Name:
UNIT PLANS
RELEASED FOR CONSTRUCTION I AN ONE BEDROOM CORNER
Subject to compliance with all regulations 1"
of State and Local Codes
City of Cannel
',�1 I
DATE: 10/31/19
UNIT B3•A1 AN ONE BEDROOM EXTENDED
SCALE: 1/4" = 1'-0"
UNIT B3•A1 AN ONE BEDROOM
SUALE: 1/4" = 1'-U
Fit 15 [G