5'-41/8"
fi
TYPE 'A' ACCESSIBLE UNITS
SEE BUILDING FLOOR PLANS SHEET A3-102 THIRD A2-104 FOR TYPE W UNIT LOCATIONS
1. ALL HARDWARE TO BE LEVER TYPE ALL LOCKING MECHANISMS TO BE
ACCESSIBLE PUSH BUTTON TYPE PER ANSI 1003.5
2. REFLECTIVE SURFACE OR MIRROR TO BE MAXIMUM HEIGHT OF 400AFF.
3. TOILET PAPER DISPENSER SHALL BE LOCATED 7" MINIMUM TO 9" MAXIMUM IN
FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
DISPENSER. THERE SHALL BE A CLEARANCE OF 1-112" MINIMUM BELOW THE
GRAB BAR.
4. ALL THRESHOLDS TO BE 1/2" MAXIMUM CHANGE IN LEVEL FROM TOP OF
THRESHOLD TO FINISHED SURFACE OF PATIO.
5. TOILET CENTERLINES SHALL BE 18" FROM ALL MEASURED FROM WALL
MEASURED FROM FACE OF DRYWALL.
6. WHEN PROVIDED,RANGE, WASHER AND DRYER TO HAVE FRONT CONTROLS
RANGE HOOD TO HAVE CONTROLS OR SWITCH WITHIN ACCESSIBLE RANGE
OF REACH.
7. WHEN PROVIDED, REFRIGERATOR TO HAVE 50%OF FREEZER 54"AFF MAX
8. EXTEND FLOOR FINISH UNDER REMOVABLE CABINETS.
9. TOILET FLUSH CONTROLS TO BE LOCATED ON THE OUTSIDE OF THE TANK ON
THE SIDE WHICH IS AWAY FROM THE WALL.
10. PROVIDE OFFSET CONTROLS, HANDHELD SHOWER, HOSE AND SLIDE BAR
PER ANSI 607.6 AT SHOWERS AND TUBS
11. WINDOW CONTROLS MUST BE 48" MAXIMUM AFF
12. ALL ROOMS SHALL HAVE 60" TURNING RADIUS
13. TOWEL BARS MOUNTED AT 48"AFF
14. PROVIDE BLOCKING FOR VERTICAL GRAB BAR AT SHOWER AND TUB
15. PROVIDE ONE OUTLET 44" ADD ON EACH WALL OF KITCHEN THAT IS A
DISTANCE GREATER THAN 36" FROMA PERPENDICULAR WALL
16. PROVIDE ONE PORTION OF ROD AND SHELF IN EACH CLOSETAT 48" AFF
17. PRIMARY ENTRANCE DOOR SHALL BE 36" WIDE
18. INTERIOR PASSAGE FLOORS SHALL BE 36"WIDE AND HAVE 18" PULL SIDE
CLEARANCE
19. INSTALL BLOCKING FOR FUTURE GRAB BARS AT TOILET, TUBS AND
SHOWERS.
20. KITCHEN WORK SURFACES: A MINIMUM30" SECTION OF COUNTER SHALL
PROVIDE A WORK SURFACE THAT COMPLIES WITH THE FOLLOWING
REQUIREMENTS:
20.1. THE COUNTER SHALL BE MOUNTED ATA MAXIMUM HEIGHT OF 34"
AFF, MEASURED FROM THE FLOOR TO THE TOP OF THE COUNTER
SURFACE
20.2.
COUNTER THICKNESS AND SUPPORTING STRUCTURE SHALL BE 2"
MAXIMUM OVER THE REQUIRED AREA
20.3. A CLEAR FLOOR SPACE 30"BY 48" SHALL ALLOW FOR A FORWARD
APPROACH TO THE WORK SURFACE COUNTER (MAY EXTEND 19"
MAX UNDER THE COUNTER). THE KNEE SPACE SHALL HAVE A
MINIMUM CLEAR WIDTH OF 30" AND MINIMUM CLEAR DEPTH OF 19"
21. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE COUNTER.
THE KITCHEN SINK AND SURROUNDING COUNTER SHALL COMPLY WITH THE
FOLLOWING REQUIREMENTS:
21.1 THE SINKAND SURROUNDING COUNTERSHALL BE MOUNTED ATA
MAXIMUM RIGHT OF 34" ADD, MEASURED TO THE TOP OF THE
COUNTER SURFACE
21.2 ROUGH IN PLUMBING SHALL BE LOCATED TO ACCEPT
CONNECTIONS OF SUPPLY AND BRAIN PIPES FOR SINKS MOUNTED
AT 28" AFF.
21.3. THE DEPTH OF (1) BOWL OF THE DOUBLE SINK SHALL BE NO
GREATER THAN 6-1/2".
21.4. FAUCETS SHALL BE LEVER OPERATED OR PUSH MECHANISMS.
COUNTER THICKNESS AND SUPPORTING STRUCTURE SHALL BE 2"
MAXIMUM OVER THE REQUIRED AREA.
21.5 A CLEAR FLOOR SPACE 30"BY 48"SHALL ALLOW FOR A FORWARD
APPROACH TO THE SINK (MAY EXTEND 19" MAX. UNDER THE
COUNTER). THE KNEE SPACE SHALL HAVE A MINIMUM CLEAR
WIDTH OF 30" AND MINIMUM CLEAR DEPTH OF 19".
21.6 THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE
SINK. HOT WATER SUPPLY AND DRAIN PIPES UNDER SINK SHALL
BE INSULATED OR OTHERWISE COVERED.
22. KITCHEN STORAGE:CABINETS, DRAWERS AND SHELF AREAS SHALL HAVE
THE FOLLOWING FEATURES:
22.1. MAXIMUM HEIGHT SHALL BE 48" FOR AT LEAST (1) SHELF OF ALL
CABINET AND STORAGE SHELVES MOUNTED ABOVE WORK
COUNTERS.
22.2. DOOR PULLS OR HANDLES FOR WALL CABINETS SHALL BE
MOUNTED AS CLOSE TO THE BOTTOM OF THE CABINET DOORS AS
POSSIBLE. DOOR PULLS OR HANDLES FOR BASE CABINETS SHALL
BE MOUNTED AS CLOSE TO THE TOP OF CABINET DOOR AS
POSSIBLE.
GENERAL NOTES - INTERIOR FRAMING
1. ALL MATERIALS AND WORK SHALL BE FURNISHED AND INSTALLED IN
WORKMANSHIP -LIKE MANNER IN STRICT ACCORDANCE WITH ALL
PREVAILING LOCAL, STATE, AND NATIONAL BUILDING CODES.
2. CONTRACTORS SHALL STORE, HANDLE, AND INSTALL ALL PRODUCTS AND
ASSEMBLIES PER THE MANUFACTURER'S INSTRUCTIONS,
RECOMMENDATIONS, AND PROCEDURES IN ORDER TO ENSURE THE
MANUFACTURER'S WARRANTY IS VALIDATED.
3. SUB -CONTRACTORS SHALL VERIFY ALL DIMENSIONS.
4. ALL DIMENSIONS ARE GIVEN FROM STUD TO STUD, UNLESS OTHERWISE
NOTED.
5. STUD DIMENSIONS ARE 31/2"OR 51/2"UNO.
6. ALL EXTERIOR WALLS ARE TO BE 2x6 STUDS. REFER TO STRUCTURAL FOR
OTHER LOCATIONS.
7. UNIT LAYOUT IS AS SHOWN ON'/." SCALE PLANS. FOR BUILDING
DIMENSIONS, REFER TO 1/8" SCALE OVERALL BUILDING FLOOR PLANS.
8. GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL,
PLUMBING, AND ELECTRICAL CONTRACTOR S FOR ALL RESPECTIVE
OPENINGS, AS REQUIRED, INCLUDING MAINTAINING FIRE RATED
ASSEMBLIES.
9. FOR MATERIALS AND FINISHES, REFER TO FINISH SCHEDULES ON THIS
SHEET.
10. TYPE'X" 518" THICK GYPSUM BOARD SHALL BE USED AT RATED WALL
CONSTRUCTION INCLUDING BEARING WALLS. TYPE "C" 5/8" GYPSUM BOARD
SHALL BE USED AT CEILINGS. REFER TO UL ASSEMBLIES.
11. ALL CEILING ASSEMBLIES ARE TO BE MIN. 1 HOUR FIRE RATED
CONSTRUCTION WITH DAMPERS AT ALL DUCT PENETRATIONS. REFER TO
MECHANICAL DRAWINGS.
12. ALL WALLS WHICH FORM PERIMETERS OF DWELLING UNITS AND ALL LOAD
BEARING WALLS SHALL BE MIN. 1 HOUR FIRE RATED UL-U305 OR UL-U314
ASSEMBLY. NOW LOAD BEARING INTERIOR PARTITIONS WITHIN DWELLING
UNITS DO NOT REQUIRE FIRE RATING.
13. USE MIN. 3/8"OSB AT ALL ATTIC DRAFT STOPS.
14, REFER TO STRUCTURAL FOR ALL WINDOW AND DOOR HEADER SIZES.
15. CONTRACTOR TO PROVIDE: (1) 12" WOOD SHELF AND ROD IN ALL ENTRY
CLOSETS, (1) 12" WOOD SHELF, ROD, AND VERTICAL SHELVING IN BEDROOM
CLOSETS, (1) 12" WOOD SHELF AT LAUNDRY, (5) 12" DEEP WOOD SHELVES IN
LINEN CLOSETS, AND (5) 18" DEEP WOOD SHELVES IN PANTRY. PROVIDE
SHELVES IN BATH ROOM AS SHOWN. REFER TO DRAWINGS.
16. REFER TO STRUCTURAL DRAWINGS FOR INTERIOR BEARING WALL MEMBER
SIZE AND SPACING.
17. FLOOR TOPPING TO BE 3/4" GYPCRETE 2000 OR APPROVED EQUAL.
CONTRACTOR TO ADJUST STAIR RISER HEIGHTS AND DOOR HEADER
HEIGHTS ABOVE SUB -FLOOR ACCORDINGLY.
18. CONTRACTOR TO PROVIDE PAPER FACED INSULATION FOR ALL EXTERIOR
WALLS. PROVIDE TYVEK VAPOR BARRIER ON ALL EXTERIOR WALLS.
19. ALL WALLAND CEILING GYPSUM BOARD TO BE SMOOTH FINISH COATING.
REFER TO FINISH SCHEDULE FOR SHEEN.
20. PROVIDE WASHER AND DRYER HOOKUPS IN ALL UNITS AS REQUIRED TO
MEET OR EXCEED APPLICABLE CODES.
21, DWELLING UNIT SEPARATION WALLS OF APARTMENT UNITS SHALL BE MIN.
ONE HOUR FIRE RATED CONSTRUCTION.
22. PROVIDE WOOD BLOCKING SUPPORT AS REQUIRED, INCLUDING, BUT NOT
LIMITED TO: ALL LOCATIONS FOR GRAB BARS IN ALL UNITS AND AT ALL
STAIR RAILS, SUPPORT FOR SHEATHING EDGES NOT ON FRAMING, KITCHEN
WALL CABINETS ON ALL FLOORS, AND AT TV WALL LOCATIONS.
23. PROVIDE R-13 (3 %') MIN. ACOUSTIC BATT INSULATION IN ALL DWELLING
UNIT SEPARATION WALLS. IN CEILINGS PROVIDE R-13 (3'/z') MIN. ACOUSTIC
BATT INSULATION AT LOCATIONS WHERE OCCUPIED SPACE ABOVE HAS A
HARD FLOOR SURFACE. PROVIDE R-19 (5 1/2") MIN. PAPER FACED THERMAL
BATT INSULATION IN EXTERIOR WALLS. PROVIDE R-30 (9') MIN. IN CEILING
ABOVE GARAGES. PROVIDE R-38 (11") MIN. IN CEILING BELOW ROOF AREAS.
24. ALL LIVING UNITS SHALL BE CONSTRUCTED TO COMPLY WITH OBC
ADAPTABLE UNIT TYPE "B" REQUIREMENTS, UNLESS DESIGNATED ADA
ACCESSIBLE UNIT TYPE "A" IN UNITS LOCATIONS SHOWN.
25. PROVIDE CONTROL JOINTS IN CORRIDOR GYPSUM BOARD CEILING 30 FEET
O.C. WITH RESILIENT CHANNELS, TYPICAL.
26. STRUCTURAL MEMBERS SUPPORTING MORE THAN ONE FLOOR SHALL BE
INDIVIDUALLY PROTECTED BYA ONE -HOUR FIRE RESISTANCE RATED
ASSEMBLY.
GENERAL NOTES - ACCESSIBILITY
ALL DWELLING UNITS SHALL COMPLY W ITH THE FOLLOWING:
1. THE HEIGHT OF THE WATER CLOSET SHALL BE AT LEAST 15" AND NO MORE
THAN 19" MEASURED TO THE TOP OF THE TOILET SEAT.
2. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A BRAG BAR OR
HANDRAIL SHALL BE 1-1/4" TO 1-1/2".
3. THE STRUCTURAL STRENGTH OF GRAB BARS, BATH TUB SEATS FASTENERS
AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS
3.1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCES BY THE
MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250 _BF
SHALL BE LESS THAN THE ALLOWABLE STRESS OF THE MATERIAL
OF THE GRAB BAR OR SEAT.
3.2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE
APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE
SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SHEAR. IF
THE CONNECTION BETWEEN THE GRAB BAR AND ITS MOUNTING
BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY
RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES
SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, WHICH
SHALL NOT EXCEEDED THE ALLOWABLE SHEAR STRESS.
3.3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE
FROM THE APPLICATION OF 250 LBF SHALL BE LESS THAN THE
ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR
MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER
IS THE SMALLER ALLOWABLE LOAD.
3.4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION
FORCE OF 250 LBF PLUS THE MAXIMUM MOMENT FROM THE
APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE
WITHDRAWAL AND THE SUPPORTING STRUCTURE.
3.5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
ILAN
WOOLPEPT
1RLRITELTYREjNGIREEmRGjGEWPATILL
7635 Interactive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
Si
L
in
J
•�
J
�A
K
rVn
V I
�
c
lY
0
O
a
M
E0
0
�r
NM
U
cCo c
co
€
mre
U
m
�U
Q Issuances:
Prom. No.: 074904
Date: 10/12/18
A Sheet Name:
UNIT PLANS
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
',"Io
DATE: 10/31/19
UNIT 1133-A1 - ONE BEDROOM • TYPE A
CCAI F- 1/d"- 1'11"
Fit M rly�