Loading...
HomeMy WebLinkAbout(09) A3-4022 3 9 I M 7 L, R "M 11031) ■� ■� ■■ MEN ■■■■■■� n - . . m ` ■■■■■■ NONE ■� MENEM NONE NONE ■■MEN ■■11 NONE MEN NONE48'MIN . .: .: NONE■ E■NENONE ■ ■L ■E MEN 0 ■E■E■E■■■■■E ■ENE■■■■■■■1 � 111111 I®� NONE ■■■■■■■�� �N■■■ NOON■■■■Oro ! EEEEE N■NE■■■■■t �.M1 W� rI NONE ■1/��}}■7■7�I�■■■■1 1■�E���//�®d® ■EMMEm4L7�■■■MENEM �EEIrI•v WN ■ENE■ SE ME MeOGJOQGE ff-E■LOMNi.: MWIEWE N■ 10113 ma Z�� NONE, , ME11,11F, `3im■m\EMEN MOWN LL ■■■\ MAE ■�E■■FIRMEl m.m I I ^�r�����1�r'm'17��1ey '�■■II� ■■11��7 m� 5'-41/8" fi TYPE 'A' ACCESSIBLE UNITS SEE BUILDING FLOOR PLANS SHEET A3-102 THIRD A2-104 FOR TYPE W UNIT LOCATIONS 1. ALL HARDWARE TO BE LEVER TYPE ALL LOCKING MECHANISMS TO BE ACCESSIBLE PUSH BUTTON TYPE PER ANSI 1003.5 2. REFLECTIVE SURFACE OR MIRROR TO BE MAXIMUM HEIGHT OF 400AFF. 3. TOILET PAPER DISPENSER SHALL BE LOCATED 7" MINIMUM TO 9" MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. THERE SHALL BE A CLEARANCE OF 1-112" MINIMUM BELOW THE GRAB BAR. 4. ALL THRESHOLDS TO BE 1/2" MAXIMUM CHANGE IN LEVEL FROM TOP OF THRESHOLD TO FINISHED SURFACE OF PATIO. 5. TOILET CENTERLINES SHALL BE 18" FROM ALL MEASURED FROM WALL MEASURED FROM FACE OF DRYWALL. 6. WHEN PROVIDED,RANGE, WASHER AND DRYER TO HAVE FRONT CONTROLS RANGE HOOD TO HAVE CONTROLS OR SWITCH WITHIN ACCESSIBLE RANGE OF REACH. 7. WHEN PROVIDED, REFRIGERATOR TO HAVE 50%OF FREEZER 54"AFF MAX 8. EXTEND FLOOR FINISH UNDER REMOVABLE CABINETS. 9. TOILET FLUSH CONTROLS TO BE LOCATED ON THE OUTSIDE OF THE TANK ON THE SIDE WHICH IS AWAY FROM THE WALL. 10. PROVIDE OFFSET CONTROLS, HANDHELD SHOWER, HOSE AND SLIDE BAR PER ANSI 607.6 AT SHOWERS AND TUBS 11. WINDOW CONTROLS MUST BE 48" MAXIMUM AFF 12. ALL ROOMS SHALL HAVE 60" TURNING RADIUS 13. TOWEL BARS MOUNTED AT 48"AFF 14. PROVIDE BLOCKING FOR VERTICAL GRAB BAR AT SHOWER AND TUB 15. PROVIDE ONE OUTLET 44" ADD ON EACH WALL OF KITCHEN THAT IS A DISTANCE GREATER THAN 36" FROMA PERPENDICULAR WALL 16. PROVIDE ONE PORTION OF ROD AND SHELF IN EACH CLOSETAT 48" AFF 17. PRIMARY ENTRANCE DOOR SHALL BE 36" WIDE 18. INTERIOR PASSAGE FLOORS SHALL BE 36"WIDE AND HAVE 18" PULL SIDE CLEARANCE 19. INSTALL BLOCKING FOR FUTURE GRAB BARS AT TOILET, TUBS AND SHOWERS. 20. KITCHEN WORK SURFACES: A MINIMUM30" SECTION OF COUNTER SHALL PROVIDE A WORK SURFACE THAT COMPLIES WITH THE FOLLOWING REQUIREMENTS: 20.1. THE COUNTER SHALL BE MOUNTED ATA MAXIMUM HEIGHT OF 34" AFF, MEASURED FROM THE FLOOR TO THE TOP OF THE COUNTER SURFACE 20.2. COUNTER THICKNESS AND SUPPORTING STRUCTURE SHALL BE 2" MAXIMUM OVER THE REQUIRED AREA 20.3. A CLEAR FLOOR SPACE 30"BY 48" SHALL ALLOW FOR A FORWARD APPROACH TO THE WORK SURFACE COUNTER (MAY EXTEND 19" MAX UNDER THE COUNTER). THE KNEE SPACE SHALL HAVE A MINIMUM CLEAR WIDTH OF 30" AND MINIMUM CLEAR DEPTH OF 19" 21. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE COUNTER. THE KITCHEN SINK AND SURROUNDING COUNTER SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: 21.1 THE SINKAND SURROUNDING COUNTERSHALL BE MOUNTED ATA MAXIMUM RIGHT OF 34" ADD, MEASURED TO THE TOP OF THE COUNTER SURFACE 21.2 ROUGH IN PLUMBING SHALL BE LOCATED TO ACCEPT CONNECTIONS OF SUPPLY AND BRAIN PIPES FOR SINKS MOUNTED AT 28" AFF. 21.3. THE DEPTH OF (1) BOWL OF THE DOUBLE SINK SHALL BE NO GREATER THAN 6-1/2". 21.4. FAUCETS SHALL BE LEVER OPERATED OR PUSH MECHANISMS. COUNTER THICKNESS AND SUPPORTING STRUCTURE SHALL BE 2" MAXIMUM OVER THE REQUIRED AREA. 21.5 A CLEAR FLOOR SPACE 30"BY 48"SHALL ALLOW FOR A FORWARD APPROACH TO THE SINK (MAY EXTEND 19" MAX. UNDER THE COUNTER). THE KNEE SPACE SHALL HAVE A MINIMUM CLEAR WIDTH OF 30" AND MINIMUM CLEAR DEPTH OF 19". 21.6 THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE SINK. HOT WATER SUPPLY AND DRAIN PIPES UNDER SINK SHALL BE INSULATED OR OTHERWISE COVERED. 22. KITCHEN STORAGE:CABINETS, DRAWERS AND SHELF AREAS SHALL HAVE THE FOLLOWING FEATURES: 22.1. MAXIMUM HEIGHT SHALL BE 48" FOR AT LEAST (1) SHELF OF ALL CABINET AND STORAGE SHELVES MOUNTED ABOVE WORK COUNTERS. 22.2. DOOR PULLS OR HANDLES FOR WALL CABINETS SHALL BE MOUNTED AS CLOSE TO THE BOTTOM OF THE CABINET DOORS AS POSSIBLE. DOOR PULLS OR HANDLES FOR BASE CABINETS SHALL BE MOUNTED AS CLOSE TO THE TOP OF CABINET DOOR AS POSSIBLE. GENERAL NOTES - INTERIOR FRAMING 1. ALL MATERIALS AND WORK SHALL BE FURNISHED AND INSTALLED IN WORKMANSHIP -LIKE MANNER IN STRICT ACCORDANCE WITH ALL PREVAILING LOCAL, STATE, AND NATIONAL BUILDING CODES. 2. CONTRACTORS SHALL STORE, HANDLE, AND INSTALL ALL PRODUCTS AND ASSEMBLIES PER THE MANUFACTURER'S INSTRUCTIONS, RECOMMENDATIONS, AND PROCEDURES IN ORDER TO ENSURE THE MANUFACTURER'S WARRANTY IS VALIDATED. 3. SUB -CONTRACTORS SHALL VERIFY ALL DIMENSIONS. 4. ALL DIMENSIONS ARE GIVEN FROM STUD TO STUD, UNLESS OTHERWISE NOTED. 5. STUD DIMENSIONS ARE 31/2"OR 51/2"UNO. 6. ALL EXTERIOR WALLS ARE TO BE 2x6 STUDS. REFER TO STRUCTURAL FOR OTHER LOCATIONS. 7. UNIT LAYOUT IS AS SHOWN ON'/." SCALE PLANS. FOR BUILDING DIMENSIONS, REFER TO 1/8" SCALE OVERALL BUILDING FLOOR PLANS. 8. GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL CONTRACTOR S FOR ALL RESPECTIVE OPENINGS, AS REQUIRED, INCLUDING MAINTAINING FIRE RATED ASSEMBLIES. 9. FOR MATERIALS AND FINISHES, REFER TO FINISH SCHEDULES ON THIS SHEET. 10. TYPE'X" 518" THICK GYPSUM BOARD SHALL BE USED AT RATED WALL CONSTRUCTION INCLUDING BEARING WALLS. TYPE "C" 5/8" GYPSUM BOARD SHALL BE USED AT CEILINGS. REFER TO UL ASSEMBLIES. 11. ALL CEILING ASSEMBLIES ARE TO BE MIN. 1 HOUR FIRE RATED CONSTRUCTION WITH DAMPERS AT ALL DUCT PENETRATIONS. REFER TO MECHANICAL DRAWINGS. 12. ALL WALLS WHICH FORM PERIMETERS OF DWELLING UNITS AND ALL LOAD BEARING WALLS SHALL BE MIN. 1 HOUR FIRE RATED UL-U305 OR UL-U314 ASSEMBLY. NOW LOAD BEARING INTERIOR PARTITIONS WITHIN DWELLING UNITS DO NOT REQUIRE FIRE RATING. 13. USE MIN. 3/8"OSB AT ALL ATTIC DRAFT STOPS. 14, REFER TO STRUCTURAL FOR ALL WINDOW AND DOOR HEADER SIZES. 15. CONTRACTOR TO PROVIDE: (1) 12" WOOD SHELF AND ROD IN ALL ENTRY CLOSETS, (1) 12" WOOD SHELF, ROD, AND VERTICAL SHELVING IN BEDROOM CLOSETS, (1) 12" WOOD SHELF AT LAUNDRY, (5) 12" DEEP WOOD SHELVES IN LINEN CLOSETS, AND (5) 18" DEEP WOOD SHELVES IN PANTRY. PROVIDE SHELVES IN BATH ROOM AS SHOWN. REFER TO DRAWINGS. 16. REFER TO STRUCTURAL DRAWINGS FOR INTERIOR BEARING WALL MEMBER SIZE AND SPACING. 17. FLOOR TOPPING TO BE 3/4" GYPCRETE 2000 OR APPROVED EQUAL. CONTRACTOR TO ADJUST STAIR RISER HEIGHTS AND DOOR HEADER HEIGHTS ABOVE SUB -FLOOR ACCORDINGLY. 18. CONTRACTOR TO PROVIDE PAPER FACED INSULATION FOR ALL EXTERIOR WALLS. PROVIDE TYVEK VAPOR BARRIER ON ALL EXTERIOR WALLS. 19. ALL WALLAND CEILING GYPSUM BOARD TO BE SMOOTH FINISH COATING. REFER TO FINISH SCHEDULE FOR SHEEN. 20. PROVIDE WASHER AND DRYER HOOKUPS IN ALL UNITS AS REQUIRED TO MEET OR EXCEED APPLICABLE CODES. 21, DWELLING UNIT SEPARATION WALLS OF APARTMENT UNITS SHALL BE MIN. ONE HOUR FIRE RATED CONSTRUCTION. 22. PROVIDE WOOD BLOCKING SUPPORT AS REQUIRED, INCLUDING, BUT NOT LIMITED TO: ALL LOCATIONS FOR GRAB BARS IN ALL UNITS AND AT ALL STAIR RAILS, SUPPORT FOR SHEATHING EDGES NOT ON FRAMING, KITCHEN WALL CABINETS ON ALL FLOORS, AND AT TV WALL LOCATIONS. 23. PROVIDE R-13 (3 %') MIN. ACOUSTIC BATT INSULATION IN ALL DWELLING UNIT SEPARATION WALLS. IN CEILINGS PROVIDE R-13 (3'/z') MIN. ACOUSTIC BATT INSULATION AT LOCATIONS WHERE OCCUPIED SPACE ABOVE HAS A HARD FLOOR SURFACE. PROVIDE R-19 (5 1/2") MIN. PAPER FACED THERMAL BATT INSULATION IN EXTERIOR WALLS. PROVIDE R-30 (9') MIN. IN CEILING ABOVE GARAGES. PROVIDE R-38 (11") MIN. IN CEILING BELOW ROOF AREAS. 24. ALL LIVING UNITS SHALL BE CONSTRUCTED TO COMPLY WITH OBC ADAPTABLE UNIT TYPE "B" REQUIREMENTS, UNLESS DESIGNATED ADA ACCESSIBLE UNIT TYPE "A" IN UNITS LOCATIONS SHOWN. 25. PROVIDE CONTROL JOINTS IN CORRIDOR GYPSUM BOARD CEILING 30 FEET O.C. WITH RESILIENT CHANNELS, TYPICAL. 26. STRUCTURAL MEMBERS SUPPORTING MORE THAN ONE FLOOR SHALL BE INDIVIDUALLY PROTECTED BYA ONE -HOUR FIRE RESISTANCE RATED ASSEMBLY. GENERAL NOTES - ACCESSIBILITY ALL DWELLING UNITS SHALL COMPLY W ITH THE FOLLOWING: 1. THE HEIGHT OF THE WATER CLOSET SHALL BE AT LEAST 15" AND NO MORE THAN 19" MEASURED TO THE TOP OF THE TOILET SEAT. 2. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A BRAG BAR OR HANDRAIL SHALL BE 1-1/4" TO 1-1/2". 3. THE STRUCTURAL STRENGTH OF GRAB BARS, BATH TUB SEATS FASTENERS AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS 3.1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCES BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250 _BF SHALL BE LESS THAN THE ALLOWABLE STRESS OF THE MATERIAL OF THE GRAB BAR OR SEAT. 3.2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SHEAR. IF THE CONNECTION BETWEEN THE GRAB BAR AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, WHICH SHALL NOT EXCEEDED THE ALLOWABLE SHEAR STRESS. 3.3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE LOAD. 3.4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF 250 LBF PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL AND THE SUPPORTING STRUCTURE. 3.5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. ILAN WOOLPEPT 1RLRITELTYREjNGIREEmRGjGEWPATILL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 Si L in J •� J �A K rVn V I � c lY 0 O a M E0 0 �r NM U cCo c co € mre U m �U Q Issuances: Prom. No.: 074904 Date: 10/12/18 A Sheet Name: UNIT PLANS RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel ',"Io DATE: 10/31/19 UNIT 1133-A1 - ONE BEDROOM • TYPE A CCAI F- 1/d"- 1'11" Fit M rly�