EQUIPMENT SCHEDULE
MARK
DESCRIPTION
ALARM BELL: POTTER ROEMER # P151208-8", ELECTRIC, 99 IDS SOUND EMISSION, WIRING BY ELECTRICAL CONTRACTOR.
AL-1
ET-1
EXPANSION TANK: WATTS # PLT-5 POTABLE WATER 2.1 GALLON TANK (NON ASME)
FDG1
FIRE DEPARTMENT CONNECTION: POTTER ROEMER# 5033 TWO WAY, TOP OUTLET,LETTERED"AUTO SPKR STANDPIPE"
FDVC-1
FIRE DEPARTMENT VALVE CABINET: POTTER ROEMER# FRC1810 RECESSED, ALUMINUM FRAME, TYPE A DOOR. 21/2"FIRE DEPARTMENT VALVE.
FS
FLOW SWITCH: POTTER ROEMER, VSR SERIES VANE TYPE WITH RETARD FEATURE
REF-1
FIRE RATED REFRIGERATOR WATER VALVE BOX: OATEY OU92, CRIMP PEX CONNECTION, WATER HAMMER ARRESTOR
REF-2
REFRIGERATOR WATER VALVE BOX: OATEY#38604, CRIMP PEX CONNECTION, WATER HAMMER ARRESTOR
RHYD-1
ROOF HYDRANT: WOODFORD #SRH-MS FREEZLESS ROOF HYDRANT
TS
TAMPER SWITCH: POTTER ROEMER,#OSYSU SERIES OR EQUIVALENT FOR SUPERVISION OF ALL COMPONENTS
WHYD-1
WALL HYDRANT: WOODFORD#B65
WM.2
DOMESTIC WATER METER: NWP SERVICES CORPORATION#1NMT-W4 METER WITH PULSE UNIT, TEHAMN BASIC MDT TRANSMITTER.
ANY WIRING FROM INDIVIDUAL METERS TO CENTRAL POINT OF MONITORING SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR
WSH-1
FIRE RATED WASHING MACHINE OUTLET BOX: OATEY#38484, CRIMP PEX CONNECTIONS,2"DRAIN, WATER HAMMER ARRESTORS.
WSH-2
WASHING MACHINE OUTLET BOX: OATEY#38105, CRIMP PEX CONNECTIONS, 2"DRAIN, WATER HAMMER ARRESTORS.
SCHEDULE NOTES:
1. PROVIDE ROUGH -IN.
2. INSTALL ALL"LOOSE"COMPONENTS
3. PROVIDE ALL NECESSARY SUPPLIES, STOPS, TRAPS, DRAINS.
4. MAKE ALL FINAL CONNECTIONS.
DRAIN SCHEDULE
MANUFACTURER
TYPE
BODY
OUTLET
STRAINER/GRATE
TOP
FINISH
ADQFEATURE
ZURN/OATEY
w
y
w
z
a
O
r
z_
¢¢
w
w
o
h
2
g
0
Q
O
¢
�n
m
O
w
g
0
0
0
¢z
rc
r
❑
w
s
w
m
r
z_
Y
o.
o:
o
W
Qom'
r
0
z
FO
W
w
yj
z
w
U'
Y
F
z
S
c'J
2
❑
m
m
U
W<
LL❑
W
Q
O
W
Q
N
Q
U
Q
W
N
F
O
W
N
g
2
Q
U
Z
z
U
N
F
U
J
p
X
W 2
MARK
CATALOG NOS.
ii
o:
U
W]
1'
S
Q
U
U
Z
m
W
7
W❑
7
Q
m
LL
W
N
m
m
41
Q
LL❑
LL
Z
Q
N
Q
LL❑
N
Q
m
F-
owl
FD-1
OATEY 43569
■
■
2"
■
4"
■
■
2
DSG7
OVERFLOW DRAIN OUTLET
COVERZ199 DC
■
■
■
1
RDA
ROOF DRAIN Z107-W2
■
■
4"
■
15"
■
■
■
OVERFLOW ROOF DRAIN
■
•
4"
■
15"
■
■
■
OD-1
Z107-W4
NOTES:
1.
SIZE AS REQUIRED
2.
PROVIDE DRAIN TRAP SEALER, SURE SEAL OR APPROVED EQUAL.
GENERAL NOTES (PLUMBING)
1. REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES NOT INDICATED
ON THE FLOOR PLANS.
2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL THE PLUMBING SYSTEM AS PER
THE STATE PLUMBING CODE AND APPLICABLE LOCAL CODES.
3. CONTRACTOR SHALL NOT SCALE THE CONTRACT DOCUMENTS FOR THE PURPOSE OF
OBTAINING FINAL MEASUREMENTS. COORDINATE WITH ARCHITECTURAL PLANS AND
ACTUAL FIELD CONDITIONS.
4. PLANS TO BE CONSIDERED DIAGRAMMATIC AND ALONG WITH SPECIFICATIONS, REFLECT
A MINIMUM ACCEPTABLE STANDARD. ALL WORK SHALL CONFORM TO THE STATE
PLUMBING CODE AND THE AMERICANS WITH DISABILITIES ACT GUIDELINES.
5. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL FEES AND PERMITS
ASSOCIATED WITH HIS PORTION OF THE WORK.
6. PLUMBING CONTRACTOR SHALL COORDINATE ALL ASPECTS OF WORK WITH OTHER
TRADES PRIOR TO AND DURING CONSTRUCTION/INSTALLATION.
T WHEN A CONFLICT BETWEEN PLANS AND SPECIFICATIONS OR NOTES OCCURS. THE
ENGINEER SHALL DECIDE WHICH GOVERNS. GENERALLY, THE MORE RESTRICTIVE, MORE
SPECIFIC, OR STRICTER PROVISION SHALL GOVERN. IF ANY DISCREPANCIES ARE
DISCOVERED ON THE PLANS OR BETWEEN THE PLANS AND THE SPECIFICATIONS, THE
CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR AND OBTAIN CLARIFICATION
OF THE INTENT FROM THE ENGINEER PRIOR TO CONSTRUCTION OR INSTALLATION OF
PROPOSEDIMPROVEMENTS.
8. REFER TO ARCHITECTURAL DRAWINGS AND INTERIOR ELEVATIONS FOR EXACT
LOCATIONS, FIXTURE HEIGHTS AND ACCESSIBILITY REQUIREMENTS.
9. PROVIDE CLEANOUTS OR WALL CLEANOUTS WHERE INDICATED ON PLANS.
10. ACCESS PANEL AT KITCHEN ISLAND PROVIDED BY GENERAL CONTRACTOR.
11. ALL PIPING SHALL BE SLOPED AT A MINIMUM OF 1/8" SLOPE.
12. ALL PIPING SHOWN ON FIRST THROUGH FOURTH FLOOR PLANS IS ABOVE CEILING,
BELOW FLOOR ABOVE.
13. ACCESS PANEL AT KITCHEN ISLAND FURNISHED BY THE GENERAL CONTRACTOR. ALL
OTHER ACCESS PANELS PROVIDED BY THE PLUMBING CONTRACTOR.
14. PIPING RUN ABOVE 4TH FLOOR CEILING SHALL BE RUN BELOW/UNDERSIDE OF ROOF
INSULATION.
GENERAL NOTES (FIRE PROTECTION
1. FIRE SYSTEM SHALL BE SUPPLIED FROM STANDPIPE STUB PROVIDED IN GARAGE PROJECT.
2, STANDPIPE WILL BE CONSIDERED WET TYPE, SUPPLIED FROM FIRE PUMP.
3. STANDPIPE SYSTEM SHALL BE INTERCONNECTED AND PROVIDED WITH FIRE DEPARTMENT
CONNECTION.
4. FLOW AND TAMPER SWITCHES SHALL BE PROVIDED AND INSTALLED BY THE SPRINKLER
CONTRACTOR. WIRING CONNECTIONS AND EXTENSION TO MONITORING LOCATIONS SHALL
BE PROVIDED BY THE ELECTRICAL CONTRACTOR.
5. FIRE SUPPRESSION CONTRACTOR SHALL FURNISH AND INSTALL SPRINKLER SYSTEMS PER
NFPA 13 GUIDELINES WITHIN RETAIL AREAS AND NFPA 13R GUIDELINES IN RESIDENTIAL
AREAS, STATE CODES AND LOCAL APPLICABLE CODES AND AMENDMENTS.
6, CONTRACTOR SHALL SECURE AND PAY FOR ALL FEES AND PERMITS ASSOCIATED WITH
THEIR PORTION OF THE WORK.
7, CONTRACTOR SHALL COORDINATE ALLASPECTS OF THEIR WORK WITH OTHER TRADES
PRIOR TO INSTALLATION / CONSTRUCTION.
8. WORK UNDER THE BUILDING #3 PROJECT SHALL CONSIST OF, BUT NOT LIMITED TO,
FURNISHING, INSTALLATION, TESTING, AND WARRANTY OF FIRE SUPPRESSION PIPING
INDICATED ON P3 SERIES DRAWINGS.
9. WHEN A CONFLICT BETWEEN PLANS AND SPECIFICATIONS OR NOTES OCCURS, THE
ENGINEER SHALL DECIDE WHICH GOVERNS. GENERALLY, THE MORE RESTRICTIVE, MORE
SPECIFIC, OR STRICTER PROVISION SHALL GOVERN. IF ANY DISCREPANCIES ARE
DISCOVERED ON THE PLANS OR BETWEEN THE PLANS AND THE SPECIFICATIONS, THE
CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR AND OBTAIN CLARIFICATION OF
THE INTENT FROM THE ENGINEER PRIOR TO CONSTRUCTION OR INSTALLATION OF
PROPOSEDIMPROVEMENTS.
10. PIPING RUN ABOVE 4TH FLOOR CEILING SHALL BE RUN BELOW/UNDERSIDE OF ROOF
INSULATION.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Cara el
',"IUJAN�
DATE: 10/31/19
BASE CABINET
OFFSET SANITARY FROI
LAVATORY IN BASE CAB
SHOE SPACE TO BEYON
BEAM. APPLIES TO SEC(
FLOOR UNITS ONLY.
2
FIXTURE SCHEDULE
MARK
DESCRIPTION
MANUFACTURER
MODEL
WASTE
VENT
HW
CW
SUPPLY/TRIM
SUPPLY/STOP
WASTE/TRIM
TRAP/FIX. DRAIN
ADD FEATURES
NOTES
CLEVELAND FAUCET GROUP
MULTI
2"P-TRAP,
42X60 ACRYLIC DROPIN TUB WITH APRON.
BTI
BATHTUB
STERLING
S711111120
2"
11/2"
1/2"
V2"
CFG463DICBNGR
INTEGRAL W/
HOUSING
DRAIN
BRUSHED NICKEL FINISH ON TRIM. CONTRACTOR TO
CFG45311
TUB/SHOWER VALVE
DIRECT 522334
AND OVERFLOW
PROVIDE LEFT OR RIGHT DRAINS PER PLANS.
SYMMONS
MULTI
2" P-TRAP,
TO BE DETERMINED. PRESSURE BALANCE TUB/
BT2
BATHTUB, ACCESSIBLE
STERLING
5711111120
2'
11/2"
1/2"
1/2"
INTEGRAL W/
HOUSING
DRAIN
SHOWER VALVE WITH STOPS. HAND HELD SHOWER
2
S-9603-X-PLR-1.5
TUB/SHOWER VALVE
DIRECT 522334
AND OVERFLOW
WITH 60" HOSE AND MINIMUM 30"SLIDE BAR.
CULTURED MARBLE TOP - WHITE
POP-UP DRAIN
WHITE UNDERMOUNT BOWL FOR CULTURED MARBLE
LV1
LAVATORY
MULTI HOUSING DIRECT
SINGLE 37"x22"-CONTEMPO BS
11/2"
11/4"
1/2"
1/2"
CLEVELAND FAUCET GROUP
ANGLE SUPPLIES W/
INCL.
1-1/4" P-TRAP
VANITY. BRUSHED NICKEL FAUCET WITH CERAMIC
DOUBLE 61")22"-CONTEMPO BS
CFG4610OBN
STOPS
WITH FAUCET
DISC AND SINGLE LEVER HANDLE.
CULTURED MARBLE TOP - WHITE
POP-UP DRAIN
WHITE UNDERMOUNT BOWL FOR CULTURED MARBLE
LV2
LAVATORY, ACCESSIBLE
MULTI HOUSING DIRECT
SINGLE 37"x22"-CONTEMPO BS
11/2"
11/4"
1/2"
1/2"
CLEVELANG FAUCET GROUP
ANGLE SUPPLIES W/
INCL.1-1/4"P-TRAP
VANITY. BRUSHED NICKEL FAUCET WITH CERAMIC
DOUBLE 61"x22"-CONTEMPO BS
C46100BN
STOPS
WITH FAUCET
DISC AND ADA APPROVED SINGLE LEVER HANDLE.
STOPS AT FAUCET,
MAXIMUM 7" DEEP BOWL.
MB1
MOP BASIN
PROFLO
PFMB2424
3"
11/2"
1/2"
1/2"
T&S Bross
CHECK VALVES ON
UNIT
3"P-TRAP
ACCESSORIES TO BE DETERMINED.
TB0667RGH
WATER SUPPLIES
9" DEEP, 18 GAUGE UNDERMOUNT STAINLESS STEEL
ANGLE SUPPLIES W/STOPS TO
SINGLE BOWL. BRUSHED NICKEL FINISH ON TRIM,
SK1
DOUBLE -COMPARTMENT SINK WITH
PROFLO
PFUC208
2"
11/2"
1/2"
1/2'
CLEVELAND FAUCET GROUP
SINK. ADDITIONAL SUPPLIES
DISPOSER
11/2"PTRAP
CERAMIC DISC FAUCET WITH SPRAYER, DISPOSAL IN-
1
DISPOSER
CFGCA42519CSL
WITH STOPS TO DISPOSER AND
STRAINER
SINK-ERATOR BADGER I WITH WHIP FOR ELECTRICAL
DISHWASHER
CONNECTION. DISHWASHER SUPPLY&DRAIN
CONNECTIONS.
4 N8" DEEP, 18 GAUGE UNDERMOUNT STAINLESS
DOUBLE -COMPARTMENT SINK WITH
CLEVELAND FAUCET GROUP
ANGLE SUPPLIES W/ STOPS
DISPOSER
STEEL DOUBLE BOWL WITH TWO DRAIN OUTLETS.
SK2
ELKAV
ELUHAD311845
2"
1 1/2"
1/2"
1/2"
TO SINK. ADDITIONAL
BRUSHED NICKEL FINISH ON TRIM, CERAMIC DISC
DISPOSER, ACCESSIBLE
CFGCA42519CSL
SUPPLIES WITH STOPS TO
STRAINER
1 1l2" P TRAP
FAUCETWITH SPRAYER, DISPOSAL INSINK-ERATOR
1
DISPOSERAND DISHWASHER
BADGER 1 WITH WHIP FOR ELECTRICAL CONNECTION.
DISHWASHER SUPPLY & DRAIN CONNECTIONS.
WEI
TANKTYPE, FLOORSETWATER CLOSET
PROFLO
PF5112WHM
W
11/2"
--
1/2"
UNIT
ANGLE SUPPLY W/ STOP
UNIT
INTEGRAL
PROFLO#PFTSE2000WH ELONGATED SEAT IN WHITE.
PF1401TYYH
TANK TYPE, FLOOR SET WATER
PF5112WHM
PROFLO#PFTSCOF2000WH ELONGATED SEAT IN WHITE.
WC2
CLOSET, ADN17" RIM
PROFLO
PF14037WH
Y
11/2"
--
1/2"
UNIT
ANGLE SUPPLY W/ STOP
UNIT
INTEGRAL
SCHEDULE NOTES:
1. DISPOSER AS SELECTED BY OWNER. PROVIDE AIR SWITCH ON COUNTER TO CONTROL OPERATION OF DISPOSER.
2. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING LOCATIONS OF ALL COMPONENTS.
3. PROVIDE'TRUEBRO' HANDI-LAV GUARD INSTALLATION KIT MODEL#102 (WHITE) OR APPROVED EQUAL
DETAIL KEY NOTES: (TYPICAL UNIT MECH. CLOSET)
1. PROVIDE CONNECTION TO TANKLESS WATER HEATER. HEATER PROVIDED BY MECHANICAL
CONTRACTOR.
2. PROVIDE HOT & COLD WATER MANIFOLD WITH INDIVIDUAL ISOLATION VALVES. ZURN QPPM (QUICK
PORT) SERIES. DETERMINE MANIFOLD OUTLETS REQUIRED PER EACH UNIT.
3. PROVIDE STUB FOR CONNECTION BY MECHANICAL CONTRACTOR. 1
4. PIPING TO AND FROM HYDRONIC AIR HANDLER PROVIDED BY MECHANICAL CONTRACTOR.
5. GAS SUPPLY FROM GAS METER.
D1
6. GAS SUPPLY TO GAS RANGE. PROVIDE GAS VALVE AND UNION AT CONNECTION. PIPING TO BE RUN
BELOW FLOOR AND RISE IN ISLAND WALL.
7. 112" PEX SUPPLY PIPING TO EACH INDIVIDUAL FIXTURE. 3/t
8. CPVC WATER RISER, SEE PLANS FOR SIZES. 3/4"
1
9. TYPE "L" COPPER PIPING FROM CONNECTION TO WATER RISER TO ALL COMPONENTS WITHIN CLOSET.
10. PROVIDE THERMOSTATIC MIXING VALVE PERASSE 1069 GUIDELINES. POWERS/WATTS 3/40-#LFLM496.1.
11. COORDINATE EXACT MOUNTING LOCATION WITH TANKLESS WATER HEATER. 3/411 ov
B\
12. EXTEND T&P DISCHARGE TO FLOOR DRAIN FOR INDIRECT DISCHARGE. GV
13. PROVIDE DIRT LEG AT BASE.
14. TANKLESS WATER HEATER PROVIDED BY MECHANICAL CONTRACTOR. REFER TO DRAWING M2-501 3/4" B\
FOR ELEVATION OF CLOSET. 13
15. HYDRONIC AIR HANDLER PROVIDED BY MECHANICAL CONTRACTOR. REFER TO DRAWING M2-501 FOR 314" 31411
ELEVATION OF CLOSET.
16. COILASSEMBLY PROVIDED BY MECHANICAL CONTRACTOR. REFER TO DRAWING M2-501 FOR
ELEVATION OF CLOSET.
'_ D1
17. REFRIGERANT PIPING PROVIDED BY MECHANICAL CONTRACTOR. 4 "A•4'
18. EXHAUST PIPING PROVIDED BY MECHANICAL CONTRACTOR. 3 *0
19. INDICATES ADDITIONAL GAS SUPPLIES SERVING ADDITIONAL FLOORS. 1 1/441
20. PEX MANIFOLD.
21. GAS SUPPLY TO RANGE.
z TYP. SECOND FLOOR LAVATORY DETAIL
3-00 3/41,= 1'-0"
DETAIL LEGEND:
BALL VALVE
BV
DRAIN VALVE WITH HOSE THREAD
DV
�., CHECKVALVE
C�HVK
TEMPERATURE AND PRESSURE RELIEF VALVE
TP
1
T UNION CONNECTION
WM WATER METER
DIRECTION OF FLOW
TEMPERING VALVE
TV
- CW - COLD WATER
- HW - HOT WATER
GAS VALVE
GAS PIPING (NAT.)
Gik
TYPICAL UNIT MECHANICAL CLOSET PIPING- ISOMETRIC (NOTE: NOT TO SCALE)
2"
EXHAUST
PIPING
REFRIGERANT PIPING
1 1/21,= 1'-0"
341
0101
0
0
FDA
CW -
- HW
�3/4"
V I
ET-1
WM-2
WATER RISER
SERVING ALL
FLOORS
PLUMBING LEGEND
SYMBOL
DESCRIPTION
VENT PIPING
SANITARY PIPING
-
DOMESTIC COLD WATER PIPING
- - -
DOMESTIC HOT WATER PIPING
OD
OVERFLOW DRAIN PIPING
NG
NATURAL GAS PIPING
BALLVALVE
PIPE UP
PIPE DOWN
OKEYNOTE
DESIGNATION
'O
ISOMETRIC DESIGNATION
OUP
TO ABOVE
1
P-0O1
DETAIL DESIGNATION
BV
BALLVALVE
CO
CLEANOUT
CW
COLD WATER
DS
STORM DOWNSPOUT
DV
DRAINVALVE
ET
EXPANSION TANK
FD
FLOOR DRAIN
GV
GAS VALVE
HW
HOT WATER
HWR
HOT WATER RETURN (HTG.)
HWS
HOT WATER SUPPLY(HTG.)
LV
LAVATORY
NG
NATURAL GAS
OD
OVERFLOW DRAIN
ODS
OVERFLOW DOWNSPOUT
SAN
SANITARY
SK
SINK
SS
SANITARYSTACK
ST
STORM
TV
TEMPERING VALVE
VR
VENT RISER
VS
VENTSTACK
VTR
VENT THRU ROOF
WC
WATER CLOSET
WCO
WALL CLEANOUT
NG
NATURAL GAS
FIRE PROTECTION LEGEND
SYMBOL
DESCRIPTION
F-
FIRE PROTECTION PIPING
^
SPRINKLER PIPING
FS
FLOW SWITCH
TS
TAMPER SWITCH
FDVC
FIRE DEPARTMENT VALVE CABINET
AL
ALARM BELL
FDC
FIRE DEPARTMENT CONNECTION
SP
STANDPIPE
FDV
FIRE DEPARTMENT VALVE
ORD
GP1
HAZARD DESIGNATION
PLUMBING SHEET LIST
%A#
-ITT--
W O U L P E R T
IRCRITEULMEjINGINEERIN6l6EMATIAL
7635 Interactive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
my
E
L
C
in
W
E
OL
0
U
J•�
J
�
W
rUn
V !
c
M
c
�
�
m
Q)
co
m
E�
NV
Q
fir,
a%
U c
cv
o C
N
NE
U
m
•- no
�U
Q Issuances:
REv
DRIC] N
are
0
Issued For Building ee 3 Revi
10/12/18
1
Issued For Building 3 Permit
06/10/19
2
ASI#10
09/11/19
Prom. No.: 074904
Date: 06/10/19
Sheet Name:
LEGEND, DETAILS,
AND SCHEDULES
1291111111