HomeMy WebLinkAbout(16) M3-0011 2 3 0 5 a 7 1 W r HVAC ABBREVIATION LEGEND PIPE SYMBOL LEGEND SCHEMATIC SYMBOL LEGEND A AMPS MC MCA MD MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPS MANUALDAMPER 1 CHWS� CHILLED WATER SUPPLY PIPE ?C PIPE DOWN �MVIAV � AIR VENT, MV-MANUAL VENT; AV - AUTOMATIC VENT ACC ACR AIR COOLED CONDENSING UNIT ACR COPPER REFRIG PIPE ! CHWR­4 CHILLED WATER RETURN PIPE PIPE UP AFF ABOVE FINISHED FLOOR MIFF MATT FACED FIBERGLASS 1-CWS­i CONDENSER WATER SUPPLY PIPE S TEE DOWN MM �� AUTOMATIC 2-WAY CONTROL VALVE ALUM APO ALUMINUM AIR PRESSURE DROP MI MUA MALLEABLE IRON MAKE UPAIR I-CWR� CONDENSER WATER RETURN PIPE l TEE UP ASJ ALL SERVICE INSULATION JACKET NC NOISE CRITERIA LEVEL T DCW­i DOMESTIC COLD WATER PIPE 1 PIPE BREAK (FOR CLARITY) IMM i AUTOMATIC 3-WAY CONTROL VALVE B OAS STEAM BOILER BUILDING AUTOMATION SYSTEM OA DOD OUTSIDE AIR OPPOSED BLADE DAMPER 1-HWS­i HEATING HOT WATER SUPPLY PIPE CAPPED PIPE t HWR--� HEATING HOT WATER RETURN PIPE •r��• GAS SHUT-OFF VALVE A W AUTOMATIC FLOW CONTROLLER BDD BACKDRAFT DAMPER O.C. ON CENTER BHP BRAKE HORSE POWER ODU OUTDOOR UNIT 1 GLYS� ICE WATER SUPPLY PIPE 1-- � BALL VALVE BOD BOTTOM OF DUCT PC PLUMBING CONTRACTOR 1-CLYR­i ICE WATER RETURN PIPE BUTTERFLY VALVE CHECK VALVE BOP BOTTOM OF PIPE PC PRESSURE DROP OR BRAZED PGGS PAINT GRIP GALVANIZED STEEL �DTS� DUAL TEMPERATURE SUPPLY PIPE ! 7 UNION C-AL CAL CORRUGATED ALUMINUM CALCIUM SILICATE INSULATION PP PPM POLYPROPYLENE PARTS PER MILLION !-DTR­i DUAL TEMPERATURE RETURN PIPE CALIBRATED BALANCE VALVE FLEXIBLE CONNECTION CCP CALCIUM CARBONATE POWDER PRESS. PRESSURE 1-DHW­i DOMESTIC HOT WATER PIPE PRESSURE REGULATING VAVVE CIF CUBIC FEET PRV PRESSURE REGULATING VALVE t-VVENT PIPE GLOBE VALVE TR GAUGE, T-TEMPERATURE; P-PRESSURE CFM CUBIC FEET PER MINUTE PS PRESSURE SENSOR 1-G---? NATURAL GAS PIPE GATE VAVLE CH CHILLER PVC POLYVINYL CHLORIDE CHP CHILLED WATER PUMP PVCGS PVC COATED GALVANIZED STEEL 1-LPG--i LIQUID PROPANE GAS PIPE STRAINER WITH BLOW DOWN VALVE �T� MANUAL BALANCE VALVE CHW CHILLED WATER RA RETURN AIR 1-RL� REFRIGERANT LIQUID PIPE S STRAINER CHWR CHILLED WATER RETURN RC ROOM CRITERIA LEVEL CHWS CHILLED WATER SUPPLY RECT RECTANGULAR !-RSA REFRIGERANT SUCTION PIPE BLIND FLANGE PIPE REDUCER/INCREASER Cl CASTIRON REFRIG. REFRIGERANT i-RHG­i REFRIGERANT HOT GAS PIPE MOTORIZED 2-WAY VALVE CL CENTERLINE RL REFRIGERANT LIQUID CLP CENTERLINE OF PIPE RF RETURN OR RELIEF FAN t-LPS� LOW PRESSURE STEAM PIPE _ p r' .LTA MOTORIZED 3-WAY VALVE PRESSURE REDUCING VALVE CMC CONIC. CEILING MOUNTED CENTRIFUGAL FAN CONCRETE RMC RMP ROOF MOUNTED CENTRIFUGAL FAN ROOF MOUNTED PROPELLER FAN T MPS MEDIUM PRESSURE STEAM PIPE l--HPS­4 HIGH PRESSURE STEAM PIPE t-­CR CONDENSATE RETURN PIPE .L PRESSURE RELIEF VALVE -0� SHUTOFF VALVE CPVC CHLORINATED PVC RTU ROOF TOP UNIT CR CRP STEAM CONDENSATE RETURN CONDENSATE RETURN PIPE RV S RELIEF VALVE SWITCH 7-FW­q FEED WATER PIPE 11 PRESSURE GAGE nIIBS� THERMOMETER Ig TT COMBINATION BALANCE -SHUTOFF VALVE CS CARBON STEEL SA SUPPLYAIR CT COOLING TOWER SC SENSIBLE CAPACITY CU COPPER SCH SCHEDULE TDV _jam TRIPLE DUTY VALVE; SHUTOFF -BALANCE -CHECK DUCTWORK SYMBOL LEGEND CW CONDENSER WATER SCR SCREWED (THREADED) CWP CONDENSER WATER PUMP SF SUPPLYFAN SAFETY RELIEF VALVE D DRAIN SO SHUT OFF VALVE TERMINAL SUPPLY OR OUTSIDE AIR DUCT UP RADIUS RECTANGULAR ELBOW DO DECIBELS SO SQUARE DCW DOMESTIC COLD WATER SS STAINLESS STEEL DIRECTION OF FLOW I"j�� RETURN OR EXHAUST AIR DUCT UP ICI f �j� SUPPLY OR OUTSIDE AIR ROUND 0 W DUCTUP CDC DIRECT DIGITAL CONTROLS SW SWEAT CONNECTION DHW DOMESTIC HOT WATER SWLD SOLVENT WELD DMPR DAMPER T THERMOSTAT SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN OR EXHAUST AIR ROUND DUCT UP CIS DUCT SILENCER (SOUND ATTENUATOR) TC TOTAL CAPACITY DT DUALTEMPERATURE TEMP. TEMPERATURE DTP DUAL TEMPERATURE PUMP TH THICKNESS � RETURN OR EXHAUST AIR DUCT DOWN ROUND DUCT DOWN DTR DUAL TEMPERATURE RETURN THIRD THREADED DTS DUAL TEMPERATURE SUPPLY TOD TOP OF DUCT E-AL EMBOSSED ALUMINUM TOJ TOP OF JOIST p �!, SUPPLY/ OUTSIDE AIR DUCT OFFSET �u�J ; ROUND OFFSET EAT ENTERING AIR TEMPERATURE TOO TOP OF STEEL EC ELECTRICAL CONTRACTOR TS TEMPERATURE SENSOR EDB ENTERING DRY BULB TEMPERATURE T/S PIPE TYPE OR SCHEDULE �� RETURN AIR DUCT OFFSET ROUND ELBOW EF EXHAUSTFAN UBC UPBLAST CENTRIFUGAL FAN EH ELECTRIC HEATER UC FLEXIBLE UNICELLULAR EWE ENTERING WET BULB TEMPERATURE UH UNITHEATER MANUAL BALANCING DAMPER ROUND WYE EWT EXH ENTERING WATER TEMPERATURE EXHAUST UV V UNITVENTILATOR VOLTS F FURNACE VAV VARIABLE AIR FLOW 121 MOTORIZED DAMPER EID RECTANGULAR BRANCH TAKEOFF FCU FANCOIL UNIT VC VENTILATING CONTRACTOR FD FIRE DAMPER WCS WROUGHT CARBON STEEL FIREDAMPER RECTANGULAR DUCT TERMINATION FFJ FOIL FACED JACKET WCU WROUGHT COPPER FG FIBERGLASS WILD WELDED CONNECTION FGB FIBERGLASS BOARD INSULATION WMP WALL MOUNTED PROPELLER FAN RECTANGULAR TO ROUND TRANSITION Q�J F ---- ROUND DUCT TERMINATION FGW FIBERGLASS WRAP WPD WATER PRESSURE DROP FLA FULL LOAD AMPS WT WEIGHT (OR DENSITY) FLG FLANGE RECTANGULAR TRANSITION 'rL� FLGD FLANGED FMG FOAM GLASS FPM FEET PER MINUTE ,mil jll�il 11 STANDARD RECTANGULAR ELBOW FPP FAN POWERED PARALLEL VAV FPS FAN POWERED SERIES VAV FS FLOW SWITCH ANNOTATION SYMBOL LEGEND FSD FIRE/SMOKE DAMPER FW FEED WATER Q THERMOSTAT OR TEMP. SENSOR (E)HUMIDISTAT �Ld SECTION SYMBOL 100 G NATURAL GAS GA GAGE(GAUGE) GALV GALVANIZED Q SWITCH GC GENERAL CONTRACTOR GPH GALLONS PER HOUR KEYNOTE DESIGNATION RTU EQUIPMENT PLAN MARK 12 GPM GALLONS PER MINUTE GRV GROOVED PIPE POINT OF NEW CONNECTION a GS GALVANIZED STEEL 4 DETAIL SYMBOL H-100 H HUMIDIFIER (HUMIDITY) 1-01 VAV TERMINAL UNIT MARK HC HEATING CONTRACTOR AHU-1 EQUIPMENTMARK HF HEAT FUSION A-8"D A-24x12 AIR DEVICE MARK -NECK SIZE 250 250 AIRFLOW HG HOT GAS (REFRIGERANT) HP HORSE POWER 8"e ROUND DUCT SIZE FPS HIGH PRESSURE STEAM HRC HEAT RECLAIM WATER 24x12 RECTANGULAR DUCT SIZE HIS HUMIDITYSENSOR AIR DEVICE AND DUCT ACCESS. LEGEND HV HEATING/VENTILonNGUNIT HIM HEATING HOT WATER HWB HOT WATER BOILER RETURN AIR GRILLE SUPPLY AIR DIFFUSER C (HARD CONNECTION) HWP HOT WATER PUMP HWR HOT WATER RETURN I�Q��,,__,a�SUPPLY AIR DIFFUSER WITH FLEXIBLE I RUNOUTAND DAMPER RETURN OR EXHAUST GRILLE (HARD CONNECTION) HWS HOT WATER SUPPLY ILC INLINE CENTRIFUGAL FAN LAT LEAVING AIR TEMPERATURE SIDEWALL DIFFUSER 14X14 TRANSFER OPENING IN WALL LDS LEAVING DRY BULB TEMPERATURE LP LIQUID PROPANE LPS LOW PRESSURE STEAM SUPPLY AIR DIFFUSER L®� (HARD CONNECTION) TRANSFER OPENING IN WALL LVR LOUVER LWB LEAVING WET BULB TEMPERATURE LWT LEAVING WATER TEMPERATURE RETURN OR EXH. GRILLE (HARD CONNECTION) M MOTORIZED MAT. MATERIAL MOH 1000 OTUH DESIGN CRITERIA GENERAL DESIGN INFORMATION INDOOR DESIGN CONDITIONS BUILDING STAIRWELL WINTER DRY BULB: 60.0°F LOCATION: CARMEL, INDIANA LATITUDE: 39.97 CORRIDORS AND TENANT ROOMS LONGITUDE: 86.13 ELEVATION: 853 WINTER DRYBULB: 70.0°F OUTDOOR DESIGN CONDITIONS WINTER RH%: AMBIENT SUMMER DRY BULB: 75.0°F SUMMERRH%: 60%MAX SUMMER DRY 91.3-F (0.4%ASHRAE DESIGN BULB: CONDITION) SUMMER WET 75.0-F (0.4%ASHRAE DESIGN BULB: CONDITION) WINTER DRY 2.6°F (99.6%ASHRAE DESIGN BULB: CONDITION) RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel PROJECT NOTES CONTROL NOTES: 1. PROVIDE PROJECT SPECIFIC CONTROL SYSTEM MANUAL FOR THE BUILDING. THE MANUAL SHALL CONTAIN A DIAGRAM OF THE CONTROL SYSTEM ARCHITECTURE, WIRING DIAGRAMS AND A SEQUENCE OF OPERATION. THE MANUAL SHALL ALSO INCLUDE AN 11 X 17 FLOOR PLAN INDICATING THE MAJOR EQUIPMENT AND PANEL LOCATIONS. THE MANUAL SHALL BE BOUND IN A HARD BACK 3 RING BINDER WITH DIVIDERS. BINDER SHALL BE LABELED "H.V.A.0 TEMPERATURE CONTROL MANUAL" AND INCLUDE THE PROJECT NAME AS WELL AS THE BUILDING NAME, NUMBER AND ADDRESS. 2. LABEL ALL CONTROL PANELS, ACTUATORS, SENSORS, ETC WITH I/8" THICK PLASTIC LAMINATE SIGNS. SEE DRAWINGS FOR LABEL AND LETTERING REQUIREMENTS. LABEL DESIGNATIONS SHALL BE CONSISTENT W ITH THE DRAWINGS, TEMPERATURE CONTROL SYSTEM MANUAL AND DIAGRAMS. 3. MOUNT WALL MOUNTED THERMOSTATS, TEMPERATURE SENSORS AND CARBON MONOXIDE SENSORS 4'-0" ABOVE FINISH FLOOR. DO NOT MOUNT THERMOSTATS OR TEMPERATURE SENSORS IN DIRECT SUNLIGHT OR NEAR HEAT PRODUCING EQUIPMENT. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MOTOR STARTERS AND DISCONNECT SWITCHES FOR H.V.A.C. EQUIPMENT UNLESS THEY ARE INCLUDED WITH THE EQUIPMENT AS INDICATED ON THE DRAWINGS AND IN THE SPECIFICATIONS. COORDINATE STARTER REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR AND THE CONTRACTOR PRIOR TO ORDERING. 5, WHERE AUXILIARY CONTACTS ARE REQUIRED IN STARTERS PROVIDED BY THE ELECTRICAL CONTRACTOR, THE MECHANICAL CONTRACTOR SHALL COORDINATE THE QUANTITY AND TYPE OF CONTACTS WITH THE E.C. PRIOR TO PURCHASE. 6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUIT BREAKERS IN THE ELECTRICAL PANELS THAT ARE SPECIFICALLY DEDICATED FOR THE TEMPERATURE CONTROL SYSTEM. COORDINATE THE QUANTITYAND SIZES WITH THE CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR LOCATION. 7, THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL TEMPERATURE CONTROL SYSTEM WIRING AND CONDUIT REGARDLESS OF VOLTAGE AS REQUIRED TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATION OR SATISFY ANY MANUFACTURER REQUIREMENTS. POWER AND CONTROL WIRING AND CONDUIT FOR VALVE ACTUATORS, DAMPER ACTUATORS, CARBON MONOXIDE SENSORS, TEMPERATURE CONTROL PANELS, RELAYS, INDICATOR LIGHTS, REMOTE CONTROL PANELS, SOLENOID VALVES AND OTHER SIMILAR DEVICES THAT ARE PART OF THE H.V.A.0 SYSTEM SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR THE LOCATION OF CIRCUIT BREAKERS SPECIFICALLY DEDICATED FOR TEMPERATURE CONTROL SYSTEM COMPONENTS. ALL 120 V CONTROL W IRING SHALL BE INSTALLED IN CONDUIT. CONCEALED ABOVE CEILING PLENUM RATED LOW VOLTAGE (24 VOLTS OR LESS) CONTROL WIRING DOES NOT REQUIRE TO BE INSTALLED IN CONDUIT. B. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROLS, RELAYS, SENSORS, CONTROLLERS, CONTROL TRANSFORMERS, CONTROL INTERFACE COMPONENTS, SOFTWARE, HARDWARE, ACTUATORS, SWITCHES AND ANY OTHER CONTROL COMPONENTS REQUIRED TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATIONS ON PLANS, TO INTEGRATE PROJECT CONTROLS AND SYSTEM, AND TO MEET EQUIPMENT MANUFACTURER'S INSTALLATION AND OPERATION REQUIREMENTS, UNLESS NOTED OTHERWISE ON PLANS. 9. IT SHALL BE THE MECHANICAL CONTRACTORS RESPONSIBILITY TO COORDINATE ALL TEMPERATURE CONTROL SYSTEM REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR PRIOR TO THE PURCHASE OR INSTALLATION OF ANY OF THE ELECTRICAL POWER ORTEMPERATURE CONTROL SYSTEM COMPONENT. 10. ALL DAMPERS ON THE INLET OR OUTLET OF THE FAN SHALL BE OPEN PRIOR TO STARTING THE FAN. PROVIDE ANY TIME DELAYS OR END SWITCHES AS REQUIRED. 11. IN PUBLIC AREAS PROVIDE CLEAR PLASTIC VENTED IMPACT RESISTANT LOCKABLE GUARDS ON ALL WALL MOUNTED THERMOSTATS OR SENSORS WITH ADJUSTABLE SET -POINTS. IDENTIFICATION: 1. PROVIDE PLASTIC LAMINATE IDENTIFICATION LABELS ON ALL EQUIPMENT SCHEDULED ON THE DRAWINGS. THE IDENTIFICATION SHALL BE CONSISTENT W ITH THE PLANMARKS SHOWN ON THE DRAWINGS AND THE BAS SYSTEM USER INTERFACE. SEE DETAILS ON DRAWINGS REGARDING COLOR, SIZE, TEXT HEIGHT, ETC. 2. PROVIDE PLASTIC LAMINATE IDENTIFICATION LABELS ON ALL TEMPERATURE CONTROL COMPONENTS SUCH AS CONTROL PANELS, TEMPERATURE SENSORS, HUMIDITY SENSORS, ETC. THE IDENTIFICATION SHALL BE CONSISTENT WITH THE PLANMARKS SHOWN ON THE DRAWINGS WHERE AVAILABLE AND THE BAS SYSTEM USER INTERFACE. SEE DETAILS ON DRAWINGS REGARDING COLOR, SIZE, TEXT HEIGHT, ETC. 3. PLASTIC LAMINATE SIGNS AND LABELS ON OUTDOOR EQUIPMENT SHALL BE FIXED TO EQUIPMENT WITH STAINLESS STEEL OR ALUMINUM RIVETS OR STAINLESS STEEL OR PLATED SCREWS. 4. CLEAN EQUIPMENT AND PIPING PRIOR TO AFFIXING ADHESIVE TYPE LABELS AND SIGNS. PROJECT NOTES GENERAL: 1. INSTALL THE H.V.A.C. SYSTEM AS INDICATED IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. 2. COORDINATE MILLWORK WITH OTHER TRADES. REWORK OF PIPING, DUCTWORK, EQUIPMENT LOCATION, CONDUIT, ETC. AS A RESULT OF POOR PLANNING. COORDINATION OR SCHEDULING SHALL BE THE RESPONSIBILITY OF THE INVOLVED CONTRACTORS. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS PRIOR TO START OF WORK. 3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ANY FRAMING REVISIONS, EQUIPMENT LOCATIONS, ADDITION OF CONTROLS, ELECTRICAL CIRCUITING REVISIONS, ETC. THAT RESULT FROM USING EQUIPMENT OTHER THAN THOSE INDICATED ON THE DRAWINGS. APPROVAL OF THE SHOP DRAWINGS BY THE ARCHITECT/ENGINEER WILL NOT WAIVE THE CONTRACTOR OF THIS RESPONSIBILITY. 4. THE MECHANICAL CONTRACTOR SHALL HAVE THE FINAL RESPONSIBILITY FOR SYSTEM START UP, TRAINING, WARRANTY AND TURN OVER TO THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTRUCTING THE OWNER ON ANY ROUTINE MAINTENANCE REQUIRED DURING THE WARRANTY PERIOD. 5. ALL ITEMS INCLUDED ON THESE DRAWINGS AND THE SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACTORS BID. ANY ITEMS THAT ARE UNCLEAR OR FOUND TO BE INCORRECT BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO THE BID DUE DATE. EXCLUSIONS OF WORK FROM THE BID ARE NOTACCEPTABLE. 6. ALL WORK INDICATED ON THE MECHANICAL DRAWINGS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. 7. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL FIRESTOPPING FOR DUCT AND PIPE PENETRATIONS THAT PENETRATE FIRE RATED ASSEMBLIES. SEE ARCHITECTURAL DRAWINGS OR REFER TO THE OWNERS RECORD DRAWINGS FOR LOCATIONS OF FIRE RATED ASSEMBLIES. ALL FLOOR PENETRATIONS SHALL BE FIRESTOPPED AND SEALED WATER TIGHT WITH A FLEXIBLE SEALANT. INSTALL PER MFG. RECOMMENDATIONS. B. THE MECHANICAL CONTRACTOR SHALL COORDINATE ANY ROOF PATCHING FOR ANY MECHANICALROOF PENETRATIONSNOTSPECIFICALLYIDENTIFIED R THEARCHITECTURAL DRAWINGS. ALL PATCHING CONSISHALL TENT TWITH THE ROONERAL F CONTRACTORCURRENT R PERFORMED IN A MANNER CONSISTENT WITH THE ROOF SYSTEMS CURRENT WARRANTY REQUIREMENTS AND MANUFACTURERS RECOMMENDATIONS. 9. THE MECHANICAL CONTRACTOR SHALL NOT PERFORM ANY WELDING OR TORCH CUTTING OPERATIONS WITHIN THE OCCUPIED BUILDING WITHOUT OBTAINING PERMISSION OR A BURN PERMIT FROM THE OWNER. DUCTWORK -GENERAL: 1. ALL DUCTWORK SHALL BE CONSTRUCTED, INSTALLED AND SUPPORTED PER THE LATEST VERSION OF THE S.M.A.C.N.A. RV.A.C. DUCT CONSTRUCTION STANDARDS. UNLESS SPECIFIED MORE STRINGENTLY IN THESE CONSTRUCTION DOCUMENTS. 2. COORDINATION OF DUCT SYSTEM INSTALLATION WITH OTHER TRADES SHALL BE PERFORMED PRIOR TO THE FABRICATION OF ANY DUCTWORK. VERIFY DUCT CLEARANCES PRIOR TO FABRICATION. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS THAT REQUIRE DIMENSIONAL CHANGES OR REQUIRE MAJOR RELOCATION OF DUCTWORK. 3. ALL DUCTWORK SHALL BE SUPPORTED FROM ROOF OR FLOOR STRUCTURE ABOVE. DUCTWORK SHALL NOT LAY ON TOP OF CEILING OR LIGHT FIXTURES. 4. ALL DUCTWORK SIZES SHOWN ARE EXTERNAL DIMENSIONS. ALLOWANCE HAS BEEN MADE FOR 1"DUCTLINER WHERE AND IF REQUIRED. 5. RECTANGULAR DUCTWORK SHALL BE SUPPORTED PER THE S.M.A.C.N.A. STANDARDS AND AT EACH CHANGE IN DIRECTION. EQUIPMENT - GENERAL 1. THE HN A.C. EQUIPMENT AND SYSTEM SHALL NOT BE USED TO DURING CONSTRUCTION. THE WARRANTY PERIOD SHALL NOT BEGIN UNTIL SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL EXTEND THE EQUIPMENT WARRANTY PERIOD AS NECESSARY WHEN EQUIPMENT IS USED AFTER INITIAL START UP AND PRIOR TO SUBSTANTIAL COMPLETION. MECHANICAL SHEET LIST SHEET NUMBER SHEET NAME M3-001 HVAC LEGEND AND NOTES M3-101 HVAC FIRST AND SECOND FLOOR PLAN M3-102 HVAC THIRD AND FOURTH FLOOR PLAN M3-103 HVAC ROOF PLAN M3401 HVAC TYPICAL ENLARGED PLANS M3-501 HVAC DETAILS M3-601 HVAC SCHEDULES WOULPERT RRCHITECTUREj N41NEERIN4l4EQYRTIRL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 07 E moll Its] in n No PElIM47 STATE OF E CL O U J•� J U c a O c � � m > M sum €� Q t0 � `o f 1 1 VVW// 0 c o Q ep L - d d LO U m GU Q Issuances: Rev DEseRI"M DRTE 0 Issued For Building 3 Review 10/12/18 1 Issued For Building 3 Permit 06/10/19 Prom. No.: 074904 Date: 06/10/19 Sheet Name: HVAC LEGEND AND NOTES DATE: 10/31/19