SECOND FLOOR PLAN - HVAC
NORTH
FLOOR PLAN - HVAC
0
DRAWING NOTES
1 EXTEND CONDENSATE (FULL SIZE) TO
JANITOR'S SINK. PROVIDE CLEANOUT AT ALL
900 ELBOWS, PIPING TO RUN ALONG WALL.
2 PROVIDE 5KW CABINET HEATER. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS, SEE
SCHEDULE.
3 PROVIDE MINIMUM 12" BASE SUPPORT TO
ALLOW CONDENSATE TO DRAIN TO JANITOR'S
SINK. EXTEND CONDENSATE DRAIN (FULL
SIZE) TO JANITOR'S SINK. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
4 PROVIDE CLEAR LOCKABLE BOX FOR
5 ROUTE REFRIGERANT PIPING UP THROUGH
CLOSET TO PIPE ROOF ASSEMBLY AND
CONDENSING UNIT ON THE ROOF PER
MANUFACTURER'S RECOMMENDATIONS.
PROVIDE OFFSETS WHEN NECESSARY.
.6 EXTEND 2" PVC EXHAUST VENT IN WALL
FROM RINNAI TANKLESS WATER HEATER TO
ROOF AND TERMINATE WITH VERTICAL
TERMINATION KIT. INSTALL PER
- MANUFACTURER'S RECOMMENDATIONS.
.7 EXTEND 2" PVC COMBUSTION AIR PIPE FROM
- RINNAI TANKLESS WATER HEATER TO LOW
PROFILE WALL TERMINATION KIT. INSTALL
PER MANUFACTURER'S RECOMMENDATIONS.
�n
1 2
KEY PLAN
NORTH
1k1/
W®®LPE CST
IRCRITEETYREjINGINEERINGICEMATIAL
7635 Interactive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
F
E
W
wo
in
OL
O
E
U
Q Issuances:
REv
DEscanmoN
MTe
0
Issued For Building 3 Review
10/12/18
1
Issued For Building 3 Permit
06/10/19
2
ASI#10
09/11/19
Prom. No.: 074904
Date: 06/10/19
A Sheet Name:
HVAC FIRST AND
SECOND FLOOR PLAN
DATE: 10/31/19
1 /8" = 1'-0"
M3=101