HomeMy WebLinkAbout(16) M3-1021 2 3 0 5 0 7 E I) N 2 a. rn N RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel FOURTH FLOOR PLAN - HVAC 1/8" = 1'-0" 1/8" = 1'-0" DRAWING NOTES 1 EXTEND CONDENSATE (FULL SIZE) TO JANITOR'S SINK. PROVIDE CLEANOUT AT ALL 900 ELBOWS, PIPING TO RUN ALONG WALL. 2 OUTSIDE AIR VENTILATION DUCT. PROVIDE 24V AUTOMATIC DAMPER INTERLOCKED TO UNIT FAN. BALANCE TO AIRFLOW INDICATED. PROVIDE FIREISMOKE DAMPER AT FLOOR PENETRATION. 3 PROVIDE MINIMUM 12" BASE SUPPORT TO ALLOW CONDENSATE TO DRAIN TO JANITOR'S SINK. EXTEND CONDENSATE DRAIN (FULL SIZE) TO JANITOR'S SINK. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4 PROVIDE CLEAR LOCKABLE BOX FOR 5 ROUTE REFRIGERANT PIPING UP THROUGH CLOSET TO PIPE ROOF ASSEMBLY AND CONDENSING UNIT ON THE ROOF PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE OFFSETS WHEN NECESSARY. 6 EXTEND 2" PVC EXHAUST VENT IN WALL FROM RINNAI TANKLESS WATER HEATER TO ROOF AND TERMINATE WITH VERTICAL TERMINATION KIT. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 7 EXTEND 2" PVC COMBUSTION AIR PIPE FROM RINNAI TANKLESS WATER HEATER TO LOW PROFILE WALL TERMINATION KIT. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 8 2" PVC VENT IN WALL FROM GAS FIRED WATER HEATER BELOW. s_f 1 2 NORTH KEY PLAN 1k1/ WO®LPE CST IRCRITEETYREjINGINEERINGICEMATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E W we, in Q 0 U � .J �^1 W � U F (n o � €Qum Q my U `o c � W � m co o c U m �" �U Q Issuances: REV DacanmoN MTe 0 Issued For Building 3 Review 10/12/18 1 Issued For Building 3 Permit 06/10/19 2 ASI#10 09/11/19 Prom. No.: 074904 Date: 06/10/19 Sheet Name: HVAC THIRD AND FOURTH FLOOR PLAN DATE: 10/31/19 M3=102