RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
FOURTH FLOOR PLAN - HVAC
1/8" = 1'-0"
1/8" = 1'-0"
DRAWING NOTES
1 EXTEND CONDENSATE (FULL SIZE) TO
JANITOR'S SINK. PROVIDE CLEANOUT AT ALL
900 ELBOWS, PIPING TO RUN ALONG WALL.
2 OUTSIDE AIR VENTILATION DUCT. PROVIDE
24V AUTOMATIC DAMPER INTERLOCKED TO
UNIT FAN. BALANCE TO AIRFLOW INDICATED.
PROVIDE FIREISMOKE DAMPER AT FLOOR
PENETRATION.
3 PROVIDE MINIMUM 12" BASE SUPPORT TO
ALLOW CONDENSATE TO DRAIN TO JANITOR'S
SINK. EXTEND CONDENSATE DRAIN (FULL
SIZE) TO JANITOR'S SINK. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
4 PROVIDE CLEAR LOCKABLE BOX FOR
5
ROUTE REFRIGERANT PIPING UP THROUGH
CLOSET TO PIPE ROOF ASSEMBLY AND
CONDENSING UNIT ON THE ROOF PER
MANUFACTURER'S RECOMMENDATIONS.
PROVIDE OFFSETS WHEN NECESSARY.
6
EXTEND 2" PVC EXHAUST VENT IN WALL FROM
RINNAI TANKLESS WATER HEATER TO ROOF
AND TERMINATE WITH VERTICAL
TERMINATION KIT. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
7
EXTEND 2" PVC COMBUSTION AIR PIPE FROM
RINNAI TANKLESS WATER HEATER TO LOW
PROFILE WALL TERMINATION KIT. INSTALL
PER MANUFACTURER'S RECOMMENDATIONS.
8
2" PVC VENT IN WALL FROM GAS FIRED
WATER HEATER BELOW.
s_f
1 2
NORTH
KEY PLAN
1k1/
WO®LPE CST
IRCRITEETYREjINGINEERINGICEMATIAL
7635 Interactive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
F
E
W
we,
in
Q
0
U
�
.J
�^1
W
�
U
F
(n
o
�
€Qum
Q
my
U
`o c
�
W
�
m
co
o c
U
m
�"
�U
Q Issuances:
REV
DacanmoN
MTe
0
Issued For Building 3 Review
10/12/18
1
Issued For Building 3 Permit
06/10/19
2
ASI#10
09/11/19
Prom. No.: 074904
Date: 06/10/19
Sheet Name:
HVAC THIRD AND
FOURTH FLOOR PLAN
DATE: 10/31/19
M3=102