Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
(18) E3-001
a `a 3 E! A n a N M R GENERAL LIGHTING/POWER NOTES GENERAL PROJECT NOTES ABBREVIATIONS ELECTRICAL LEGEND A AMPS KW KILOWATTS AFF ABOVE FINISHED FLOOR LGTG LIGHTING 1. LIGHT FIXTURES DESIGNATED AS"NIGHT LIGHTS"SHALL BE ON UNSWITCHED CIRCUIT, UNLESS NOTED. 1. WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL, STATE OF INDIANA, 2008 NEC AND NATIONAL CODES, RECOMMENDATIONS, REGULATIONS, AND REQUIREMENTS. APE ABOVE FINISHED GRADE MECH MECHANICAL BKR BREAKER NIC NOT IN CONTRACT LIGHTING FIRE ALARM C CONDUIT NIL NIGHT LIGHT 2. EXIT LIGHTS SHALL BE ON UNSWITCHED CIRCUIT, UNLESS NOTED. 3. ALL RECESSED DOWNUGHTS MOUNTED IN GRID CEILING SHALL BE CENTERED IN CEILING TILE, UNLESS NOTED. 2. CONTRACTORS SHALL VISIT PROJECT SITE PRIOR TO BIDDING TO ASCERTAIN AND BECOME FAMILIAR WITH EXISTING CONDITIONS AS THEY PERTAIN TO THE SCOPE OF WORK. CONTRACTOR SHALL VERIFY EXACT LOCATION AND SIZES OF ELECTRICAL EQUIPMENT AND ALL OTHER APPURTENANCES ASSOCIATED WITH THE WORK. CAW CABLE TELEVISION NTS NOT TO SCALE CUH CABINET UNIT HEATER PVC POLYVINYL CHLORIDE CKT CIRCUIT P PHASE (POLE) Cu COPPER TTB TELEPHONE TERMINAL BOX A LIGHTING FIXTURE. REFER TO FIXTURE SCHEDULE. LETTER INDICATES TYPE. 0 FIRE ALARM PULL STATION. 44"AFF. F FIRE ALARM HORN/STROBE. 80"AFF. E EXISTING TYP TYPICAL FOR BRANCH ARE #12AWG MININUM, UNLESS NOTED. DEBATE PER CODE 4. WHERE WHERE CIRCUITS ARE COMBINED. STS ARE COMBINED. 5. ALL ROVIDE GREEUN N UNLER CODE G. CONDUCTORBACK TO ALL ALL BE #10 BRANCH CWG IRCUITRY. PROVIDE A GREEN GROUND CONDUCTOR IN ALL BRANCH CIRCUITRY. DEBATE PER CODE WHERE 3. NOTESPHASINGCOORDINATED WITH ALL DOWNS, (ELECTRIC AND RE UI EMENT.COOR COORDINATE AND AND NOTESONE)WI WITH OWNERTHAN 2HOURICAND TELEPHONE) W ITH THE OW NERAND PROVIDE NOTICE NOT LESS THAN 72 HOURS IN ND PR TE PROVIDE TICS NOT LESS ADVANCE. EF EXHAUSTFAN UON UNLESS OTHERWISE ENOTEDLid ELEC ELECTRICAL UV UNIT VENTILATOR EM EMERGENCY V VOLTS EMT FANEMERGENCY METALLIC TUBING VAV VARIABLE AIR VOLUME FCU FAN COIL UNIT VIF VERIFY IN FIELD A NL INDICATES EMERGENCY LIGHTING ULL EMERGENCY MINIMUM 1400 LUMENS NIGHT LIGHT CIRCUIT. FULL LUMEN OUTPUT MINIMUM 1400 LUMENS ON LAMP. � l:� FIRE ALARM DUCT MOUNTED SMOKE DETECTOR.S=SUPPLY R= WITH DUCTWORK. MAKE SAMPLING TUBE FULL RETURN -DUCTI LENGTH. WIDTH OF DUCT IN LENGTH. 06 LIGHTING FIXTURE. LETTER INDICATES TYPE. FIRE ALARM CEILING MOUNTED SMOKE DETECTOR. CIRCUITS ARE COMBINED. 6. ALL CONDUIT CEILING. PS FOR PLENUM RATED CABLES SHALL BE PROVIDED WITH ACONDUIT BUSHING ABOVE CEILING. 4. PLUMBING ONTRAC O FOR NEW OR RENOVATED WORK WITH THE CHA ICAL CONTRACTORS. MECHANICALAS O TOR RIFY STARTERS DISCONNEHASE ANDCTS. REQUIREMENTS, SUCH ACCESSORY REQUIREMENTS, SUCH AS MOTOR STARTERS AND DISCONNECTS. ACCESSORY G GROUND W WATTS GFI GROUND FAULT INTERRUPTER WC WATER EATHER OLERROO GRC GALVANIZED RIGID CONDUIT WP WEATHERPROOF HP HORSEPOWER UH UNIT HEATER OB EMERGENCY LIGHTING FIXTURE WITH EMERGENCY BALLAST. OR POW EKED THROUGH INVERTER SYSTEM. OCO COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR. O FIRE ALARM CEILING MOUNTED HEAT DETECTOR. 5. CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR HIS J JUNCTION BOX UNO UNLESS NOTED OTHERWISE CEILING MOUNTED EXIT SIGN. REFER TO FIXTURE SCHEDULE. SHADED AREA DENOTES FACE OF UNIT. CONNECT TO LOCAL UNSWITCHED LIGHTING CIRCUIT. SD SMOKE DAMPER. PROVIDE SMOKE DETECTOR FOR DAMPER OPERATION AND 120 VOLT POWER CONNECTION AS SHOWN ON THE POWER DRAWINGS. COORDINATE ALL CONNECTIONS WITH MECHANICAL CONTRACTOR. CONNECT TO ALARM SYSTEM. 7. WHERE TERMINATED IN J-BOX, ALL SPARE CIRCUITRY SHALL BE LABELED WITH PANEL AND CIRCUIT NUMBER. 8. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE ALL NECESSARY AUXILLARV WORK. OPENING IN WALLS, FLOORS AND CEILINGS DUE TO REMOVALS SHALL BE FILLED IN, PATCHED, PAINTED AND FINISHED IN A MANNER TO MATCH THE QUALITY OF THE EXISTING, LIKE ADJACENT SURFACES. KVA KILOVOLTAMPERE WALL MOUNTED EXIT SIGN. REFER TO FIXTURE SCHEDULE. SHADED AREA DENOTES FACE OF UNIT. CONNECT TO LOCAL FgCp FIRE ALARM CONTROL PANEL. CONTACTS, RELAY, ETC. IN MOTOR STARTERS FOR REQUIRED CONTROL OF MECHANICAL EQUIPMENT. 6. NEW OPENINGS IN EXISTING WALLS AND FLOORS SHALL BE CORE DRILLED OR SAW CUT. OPENINGS IN NEW WALLS AND FLOORS SHALL BE PLANNED AND COORDINATED Fpgp O FIRE ALARM ANNUNCIATOR PANEL. 9. ALL UNDERGROUND PVC CONDUITS SHALL HAVE RIGID GALVANIZED STEEL ELBOWS. ALL WITH GENERAL CONTRACTOR FOR THE INSTALLATION OF APPROPRIATE SLEEVES. UNSWITCHED LIGHTING CIRCUIT. S SINGLE POLE WALL SWITCH. 1201277 VOLT, 20 AMP. 44" AFF. ID FIRE ALARM STROBE. 80"AFF. RECEPTACLE OR LOCATIONS FOR POWER TO ELECTRIC WATER COOLERS SHALL BE THE INSTALLATION LOCATIONS OF THE ELECTRIC WATER COOLERS, UNLESS COORDINATED WITHITH THE NOTED. 7. ALL CONDUIT SHALL BE 1/2"MINIMUM U.N.O. B. CONDUIT SHALL BE CONCEALED IN CEILING OR WALLS WHEREVER POSSIBLE. yS3 THREE WAY WALL SWITCH. 120/277V, 20 AMP. 44"AFF 10. ALL LIGHT FIXTURES SHALL BE SEISMICALLY BRACED WITH AN INDEPENDENT WIRE (CEILING GRID TYPE WIRE) FROM TWO OPPOSITE CORNERS TO STRUCTURAL CEILING OR BAR JOIST. 9. ALL UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC UNLESS NOTED OTHERWISE. �4 . , . FOUR WAYWALL SWITCH120/277V20 AMP44"AFF WP EXTERIOR FIRE ALARM BELL. WP-WEATHERPROOF �OS OCCUPANCY SENSOR WALL SWITCH. 120/277V, 20 AMP. 44" AFF 0 MAGNETIC DOOR HOLD OPEN. 11. GO NOT SUPPORT CONDUIT OFF OF CEILING GRID, CEILING GRID SUPPORTS, MECHANICAL 10. ALL BRANCH CIRCUITS AND FEEDERS SHALL CONTAIN A GREEN INSULATED GROUND SUPPORTS, OR ANY OTHER TRADE'S SUPPORTS. INSTALL CONDUITS AND BOXES ON SEPERATE SUPPORTS FROM BAR JOIST OR STRUCTURE. CONDUCTOR. GROUNDING BY MEANS OF RACEWAY IS NOT PERMITTED. �p SINGLE POLE WALL SWITCH WITH PILOT LIGHT. 120(277V, 20 AMP. 44"AFF FR-P-Sl FIRE ALARM REMOTE POWER SUPPLY 12. DO NOT SUPPORT FROM METAL ROOF DECK. PROVIDE SUPPORT FROM CONCRETE SLABS, BAR 11. REFER TO MECHANICAL, PLUMBING, AND ARCHITECTURAL PLANS FOR EXACT LOCATION OF EQUIPMENTS D DIMMER SYSTEM CONTROL STATION. REFER TO DWG _. �Z FIRE ALARM MONITOR MODULE JOIST, STRUCTURAL BEAMS, COLUMNS OR UNISTRUT BETWEEN STRUCTURAL ELEMENTS. 12. COORDINATE LOCATIONS OF LIGHTING FIXTURES IN MECHANICAUELECTRICAL ROOMS OS OCCUPANCY SENSOR. ® FIRE ALARM CONTROL RELAY MODULE 13. ALL SINGLE PHASE CIRCUITS SHALL HAVE A SEPERATE DEDICATED NUETRAL CONDUCTOR FOR EACH CIRCUIT. SHARING OF NUETRAL CONDUCTOR IS NOT PERMITTED. 14. PROVIDE 4" HIGH, SMOOTH FINISH CONCRETE HOUSEKEEPING PADS UNDER ALL TRANSFORMERS WITH EQUIPMENT, PIPING AND DUCTWORK. 13. VERIFY CEILING TYPES PER THE ARCHITECTURAL REFLECTED CEILING PLAIN. PROVIDE APPROPRIATE TYPE FIXTURE, LAY -IN FOR GRID, FLANGE FOR DRYWALL, ETC. EXTERIOR LIGHT FIXTURE. ER- EXISTING TO REMAIN. PI-1 -NEW FIXTURE. REFER TO FIXTURE SCHEDULE. FS FIRE SUPPRESSION FLOW SWITCH TS FIRE SUPPRESSION TAMPER SWITCH (45KVA AND LARGER) AND MAIN DISTRIBUTION SWITCHBOARDS. PAD SHALL BE 4" LARGER THAN TRANSFORMER AND SWITCHBOARD IN EACH DIRECTION. USE 3000 PSIG, 28 DAY COMPRESSIVE 14. VERIFY AND COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF ALL DEVICES E.O.L.R.� END OF THE LINE RESISTOR. STRENGTH CONCRETE. ROUND ALL EDGES AND CORNERS OF CONCRETE PAD. MOUNTED IN CASEWORK OR ABOVE COUNTERS WITH SPECIFIC EQUIPMENT POWER KNOX BOX WITH ALARM CONTACT. FURNISHED. 15. NO MORE THAN 3 PHASE CONDUCTORS SHALL BE INSTALLED IN ANY ONE CIRCUIT, UNLESS NOTED OTHERWISE. EACH BRANCH CIRCUIT SHALL CONTAIN THEIR OWN ® n TAMPER RESISTANT DUPLEX RECEPTACLE. 120 VOLT, 20 AMP. 16" AFF UNO. DUCT MOUNTED SMOKE DAMPER BY MECHANICAL CONTRACTOR PROVIDE A DUCT MOUNTED SMOKE DETECTOR, WITH RELAY BASE, MOUNTED WITHIN 6-0" OF THE NEUTRAL CONDUCTOR. NO SHARED NEUTRALS. DAMPER WITH NO AIR OUTLETS OR INLETS BETWEEN THE DETECTOR AND THE TAMPER RESISTANT DUPLEX RECEPTACLE MOUNTED AT 44" OR ABOVE DAMPER. 16. FURNISH ALL ELECTRICAL ACCESS FLOORS TO GENERAL CONTRACTOR FOR HIS BACKSPLASH. 120 VOLT, 20 AMP. INSTALLATION. REFER TO SPECIFICATIONS FOR ACCESS DOOR REQUIREMENTS. DOOR ACCESS 18. CONTRACTOR SHALL PROVIDE ALL FIRESTOPPING FOR CONDUIT OR CABLE TRAY TTjr TAMPER RESISTANT DOUBLE DUPLEX RECEPTACLE. 120 VOLT, 20 PENETRATIONS THAT PENETRATE ACOUSTICAL RATED OR SMOKE AND FIRE RATED ASSEMBLIES. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL RATED YT AMP. 16" AFF UNO. O ELECTRIC DOOR STRIKE. ASSEMBLIES. ALL RATED PENETRATIONS SHALL BE FIRESTOPPEG TO ORIGINAL ASSEMBLY RATING. ALL NON -RATED FLOOR PENETRATIONS SHALL BE SEALED WATER TAMPER RESISTANT 120 VOLT DOUBLE DUPLEX, 20 AMP RECEPTACLE © DOOR SWITCH/CONTACT. TIGHT WITH A FLEXIBLE SEALANT. + MOUNTED AT 44"AFF OR 4" ABOVE BACKSPLASH. 19. BRANCH WIRING CHART GUIDELINE FOR VOLTAGE DROP ❑K IN TAMPER PROOF ENCLOSURE. KEY OR KEYCARD -WEATHERPROOF. WP-WEATHERPROOF. ECONDUIREUTILIZED COMPENSATION, SIZE. COMPENSATION, INCREASE CONDUIT SIZING PER WIRE SIZE. (APPLIES TO ALL SHEETS) SATIO ,WRING ��jjj�a DUPLEX RECEPTACLE WITH GROUND FAULT PROTECTION. 120 VOLT, 20 AMP. A. 20A-120 VOLT CIRCUITS 2 G HWP 18"AFF UNO. ❑ JUNCTION BOX DUPLEX RECEPTACLE WITH INTEGRAL USB OUTLETS. 120 VOLT, 20 AMP. 18" Q HANDICAP DOOR ACCESS BUTTON IN FLUSH WALL BOX a. #12 WIRE .75' LENGTH MAX. -#12 GRID. b. #10 WIRE -125' LENGTH MAX. - #10 GIRD, AFF UNO. c. #8 WIRE - 200' LENGTH MAX. -48 GRID. d. #6 WIRE - 300' LENGTH MAX. - #6 GRID.® USB GROUNDING FLUSH FLOOR DUPLEX RECEPTACLE IN FLOOR BOX. 20. PROVIDE ALL ERANDACCESSIBLE H CIR THAT EXCEED BNEC OXESNUMBER OF ENGT BOXES, BENDS LENGTH IN FEEDER AND BRANCH CIRCUITS. INSTALL BOXES WHERE 120 VOLT SINGLE 20 AMP RECEPTACLE. Q' G GROUND ROD 3/4" DIA. x 10' LONG REQUIRED PER CODE LOCATED IN COMMON AREAS AND EXTERIOR AREAS. ED 21. ALL WIRING DEVICES SHALL BE OF COMMERCIAL GRADE CONSTRUCTION. REFER TO ARCHITECTURAL SHEETS AND CODE SHEET FOR ALL FIRE -RATED PARTITION ® SPECIAL PURPOSE RECEPTACE. REFER TO FLOOR PLANS FOR NEMA CONFIGURATION. • F GROUND CABLE EXOTHERMIC WELD CONNECTION TO REBAR ROD IN CONCRETE FOOTER. LOCATIONS AND RATINGS. �M FRACTIONAL HP MOTOR STARTER WITH THERMAL OVERLOADS. wS GROUND CABLE EXOTHERMIC WELD CONNECTION TO BUILDING STEEL. 22. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CORE -DRILLS REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. e0e ELECTRICAL MOTOR. 23. ROUTING OF CIRCUITRY INSTALLED IN CASEWORK, CABINETRIES, ETC. SHALL BE COORDINATED FOR PROPER CONCEALMENTAND FUNCTION OF CASEWORK, �b INDICATES FINAL CONNECTION REQUIRED. UNDERGROUND COPPER CABLE. CABINETRIES, ETC. 24. VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO EXCAVATION, TRENCHING, OR PP11-21 HOMERUN TO PANELBOARD. NOTION INDICATES PANELAND CIRCUIT NUMBER. (ALL CONDUCTORS SHALLBE #10 UNLESS NOTED OTHERWISE.) GENERAL DRILLING. 25. ALL ROOF PENETRATIONS OR PATCHES SHALL BE MADE PER ROOFING O ELECTRICAL PANELBOARD. 1 DETAIL # DETAIL REFERENCE TAG MANUFACTURER WARRANTY REQUIREMENTS. O JUNCTION BOX. E-406 DRAWING# REFER TO DETAIL SHEETS 26. ALL EXPOSED METAL CONDUITS ARE TO BE PAINTED TO MATCH THE ADJACENT SURFACE. COORDINATION OF PAINTING OF CONDUIT IS TO BE BY THE ELECTRICAL WC}{ 120 VOLT 20 AMP DUPLEX, GFI RECEPTACLE FOR ELECTRIC WATER COOLER, O KEYNOTE FOR DRAWING CONTRACTOR, WITH PAINTING BY OTHERS. RY COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR. 1 27. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL REQUIRED JUNCTION BOXES, PULL BOXES. ETC FOR A COMPLETE INSTALLATION PER THE N.E.C. E-406 DETAIL REFERENCE TAG (SECTION) BA BUILDING AUTOMATION CONTROL PANEL. AND LOCAL CODES. ALL CONDUCTORS SHALL BE RATED FOR 90 DEGREE CELSIUS. 28. COORDINATE WORK WITH OTHER TRADES. COORDINATION OR SCHEDULING SHALL BE CONDUIT STUB -OUT AND CAP BELOW GRADE. MARK STUB -OUT AT GRADE LEVEL. 1 I1_ e ORATION DETAIL DOORTER NEXT DO REFERENCE RACE TAG LETTER NEXT TO TAG REFERS TO SPECIFIC DOOR OR CABLETRAY TO AG REFERS RESPONSIBILITY OF THE INVOLVED CONTRACTORS. -UE- UNDERGROUND HIGH VOLTAGE OR SECONDARY SERVICE FEED. E-002 o LAYOUT. CONFIGURATION INGICATIEG IN DETAIL. OJ SAFETY DISCONNECT SWITCH (NON -FUSED). EF- MECHANICAL EQUIPMENT TAG. REFER TO EQUIPMENT DATA OJ SAFETY DISCONNECT SWITCH (FUSED). SCHEDULE. ®J COMBINATON MOTOR STARTER/DISCONNECT. WITH HOA SWITCH AT UNIT (FUSIBLE). OR (CIRCUIT BREAKER FOR ELEVATOR). UDB UNIT DISTRIBUTION BOX -FURNISHED AND INSTALLED BY E.C.- a SOHO 28"H x 14.25"W x 3.75"D FOR TELEPHONE/CAN DISTRIBUTION DATA AND COMMUNICATION 0 DATA /COMMUNICATION OUTLET. TWO PORTS REFER TO DETAIL FOR MOUNTING REQUIREMENTS. VW WALL PHONE. 54"AFF. 17 DATA OUTLET. W AFF. Q4 DATA/COMMUNTICATION. FOUR PORT DATA, 16"AFF. Q6 DATA/COMMUNTICATION. SIX PORT DATA, 16" AFF. Rl7m"n CABLE TRAVABOVE CEILING. 0 WIRELESS ACCESS CONNECTION POINT WITH CEILING MOUNTED CISCO WAP WIRELESS DEVICE. _COM- UNDERGROUND COMMUNICATION DUCT. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel �PAGIUI DATE: 10/31/19 ELECTRICAL SHEET LIST SHEET NUMBER SHEET NAME E3-001 LEGEND AND ABBREVIATIONS E3-101 LIGHTING PLAN- PARKING AND FIRST FLOOR E3-102 LIGHTING PLAN -SECOND AND THIRD FLOOR E3-103 LIGHTING PLAN- FOURTH FLOOR AND ROOF E3-111 POWER AND SYSTEMS PLAN -PARKING AND FIRST FLOOR E3-112 POWER AND SYSTEMS PLAN- SECOND AND THIRD FLOOR E3-113 POWER AND SYSTEMS PLAN- FOURTH FLOOR AND ROOF E3-301 SECTION DETAILS E3401 ELECTRICAL ENLARGED PLANS E3402 ELECTRICAL ENLARGED PLANS E3403 ELECTRICAL ENLARGED PLANS E3-501 ELECTRICAL DETAILS E3E01 SINGLE LINE DIAGRAM - WEST E3-602 SINGLE LINE DIAGRAM - EAST E3-701 PANELBOARD SCHEDULES E3-001 EQUIPMENT AND LIGHT FIXTURE SCHEDULES 1ktff W O U L P E R T aRCNITECTUREj NDINEERINDIDEMATIIL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E U. 10 III W E OL (_0`J W W E U J•� J K W U F m o a > N M Q my W � `o c m co o c 120 m = U Q Issuances: Raw DEsMMM MTE 0 Issued For Building 3 Review 10/12/18 1 Issued For Building 3 Permit 06/10/19 2 ASI #10 09/11/19 Prom. No.: 074904 Date: 08/08/18 A Sheet Name: LEGENDAND ABBREVIATIONS E3=001