Loading...
HomeMy WebLinkAbout(00) G3-0002 I 3 I 4 s 6 7 e I 9 fi DID - 2 U a Gn m a m v rn tz m E E c U 2 � a` a , PROJECT TEAM ILA I WOOLPERT — 1203 Walnut Street, Second Floor Cincinnati, OH 45202 W O O L P E R T Tel: 513.272.8300 DES I GN I GEOSPATIAL I I NGRASTRUCTU R E Fax: 937.461.0743 www.woolpert.com LOCATION MAP v clan:.ale wnheatown C) Car el mePhe�d --PROJECT HeirZionsville SITE °iSj e Lumaven CP ® — d J/ Foreplay Rosa o woaabury al Ills MCGmtlsnik —W CD ag Ell Greek ve Pina i Jf " L rows Nest {;p `J reeasent Acres &owlnemy eockv Ripple �mence MO Mwk Spring Hill MtMt Comfort niaen / Gale Avon t-1 ON - Liain'eta Cr ramaawooa :e'velky coma Cant lce atonal 5 z IN Carmely, m rp` r E 116m st R°€ _ r ... Wettm no Gem Mlena Li Beeclt6rove Homee,olt ' � somnpon 1v/[l7I►IIII Ii■►lilrA6 so va Delmore or Fttulive Dr rc,oge,11 14 - so sa amrell or W Carmel or E Carmel Dr General shaleRna a PROJECT SITE Unrest! SaostorageDeny DumIGIm CI city sa,eegve n Mmiaal Dr aangefire Geri A 73 aa E 1161h et E 116m S1 n400 New Palestine J s R E Carmel or in a Governor square Ap.tnent. E n 6tn St ye F The Proscenium Development 1 1 1 1 I II 1 1 MI BUILDING TABULATION BUILDING 3: ISSUED FOR PERMIT JUNE 109 2019 PROJECT IMAGE sta g ,..� e i BUILDING 3 SUMMARY QUANTITIES FLOOR UNITS/FLOOR NET UNIT SF 63-A1 B3-A3 B3-B1 CORRIDOR (SF) STAIR (SF) MECH/UTILITY (SF) 1 0 - 0 0 0 - 378 52 2 11 10,517 7 1 3 1,337 378 167 3 11 10,517 7 1 3 1,337 378 167 4 11 10,517 7 1 3 1,337 378 167 TOTAL 33 31,551 21 3 9 4,011 1512 553 NAME SF UNIT# UNITTYPE UNIT DES. UNIT RESTAURANT 6,614 RETAIL 2,416 FITNESS 1,279 ENTRY 242 BOH 447 TOTAL 10,998 A3 1 BRA BH 1,155 Bl 2 BR/2 BH 1,150 Bl 2 BR/2 SH 1,210 Al 1 BR/1 BH 778 Al 1 BR/1 SH 894 Bl 2 BR/2 SH 1,193 Al 1 BR/1 SH 792 Al 1 BR/1 SH 905 Al 1 BR/1 SH 792 Al 1 BR/1 BH 824 Al 1 BR/1 BH 824 TOTAL 10,517 GENERAL NOTES A. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD PRIOR TO ORDERING OR FABRICATION OF MATERIALS OR THE BEGINNING OF CONSTRUCTION. NOTIFY ARCHITECT AND OWNER REPRESENTATIVE OF ALL DISCREPANCIES. ALL WORK REQUIRING MEASURING TO BE DONE ACCORDING TO FIGURES ON DRAWINGS. DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND OWNER REPRESENTATIVE. CONTRACTOR TO SUBMIT SPECIFIC DISCREPANCY FOR ARCHITECT REVIEW, PRIOR TO COMMENCING WITH THE WORK IN QUESTION. B. ALL WORK TO CONFORM TO LOCAL CODES, ORDINANCES AND REQUIREMENTS. C. THE CONTRACTOR SHALL ARRANGE FOR THE PREMISES TO BE MAINTAINED IN AN ORDERLY MANNER, FREE OF DUST AND DEBRIS,THROUGHOUT THE COURSE OF THE WORK. PROVIDE AND MAINTAIN TEMPORARY BARRICADES AS REQUIRED TO PROTECT THE PUBLIC AND OWNERS PERSONNEL DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING STRUCTURE OR EQUIPMENT. ANY SUCH DAMAGE SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. D. CONTRACTOR SHALL PROVIDE DAILY OR MORE FREQUENT GENERAL CLEAN UP IN COMPLIANCE WITH OWNER'S REQUIREMENTS OF AREAS WITHIN THE LIMITS OF CONSTRUCTION, AND FINAL CLEAN UP AT CONCLUSION OF WORK. E. CONTRACTOR TO REVIEW OTHER DRAWINGS ISSUED FOR THIS PROJECT FOR ADDITIONAL INFORMATION FROM OTHER TRADES TO COORDINATE THE REQUIRED SCOPE OF WORK. F. DO NOT SCALE FROM THE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE. THE OWNER'S REPRESENTATIVE MUST BE NOTIFIED OF ANY CONFLICTS IN DIMENSIONING. G. EXTERIOR DIMENSIONS ARE TO FACE OF BRICK VENEER OR FACE OF METAL STUD, BRICK VENEER, MASONRY OPENING, OR COLUMN CENTERLINE UNLESS OTHERWISE NOTED. INTERIOR DIMENSIONS ARE TO FACE OF EXTERIOR STUD, FACE OF MASONRY, FACE OF CONCRETE, CENTERLINE OF COLUMNS, OR FACE OF INTERIOR STUD UNLESS OTHERWISE NOTED. H. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE NEW AND AS SPECIFIED, UNLESS IDENTIFIED OTHERWISE. I. ALL NEW FINISHED AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF IMPERFECTIONS AND IN PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS SHALL MATCH THE ADJACENT MATERIALS CONSTRUCTION AND FINISH. J. ALL FLOORS ON EITHER SIDE OF A DOORWAY OR OPENING SHALL BE LEVEL AND HAVE MAXIMUM ELEVATION DIFFERENCE OR THRESHOLD HEIGHT OF 1/2". K. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE 4e FROM THE FACE OF STUD TO FACE OF STUD OF DOOR FRAME JAMB UNLESS NOTED OTHERWISE. L. DOOR SIZES, STYLES, AND SPECIFICATIONS, ROUGH OPENING SIZES AND EXACT LOCATIONS TO BE CHECKED AND VERIFIED BY THE CONTRACTOR BEFORE ORDERING AND BEFORE CONSTRUCTION BEGINS. M. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS AND CEILINGS TO BE SEALED WITH PROPER APPROVED MATERIALS TO THE FULL THICKNESS OF THE CONSTRUCTION ELEMENTS. N. FIRE STOP ALL FLOORS, WALLS AND CEILINGS AS REQUIRED BY APPLICABLE CODE. O. ALL WOOD BLOCKING IN EXTERIOR WALLS TO BE MOISTURE RESISTANT TREATED IN ACCORDANCE WITH SPECIFICATIONS. WHERE REQUIRED BY CODE, ALL WOOD BLOCKING IN INTERIOR WALLS TO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH SPECIFICATIONS. P. INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR AIR INFILTRATION EXCEPT AS NOTED OTH ERW ISE. SEALANT COLOR TO MATCH ARCHITECTS SAMPLE. COLOR REQUIRES ARCHITECTS APPROVAL. Q. PROVIDE FIRE EXTINGUISHER COMPLYING WITH NFPA 10 AS INDICATED ON LIFE SAFETY DRAWINGS WITH MAX TRAVEL DISTANCE OF 75'. R. MASONRY CONTROL JOINTS ARE SHOWN FOR REFERENCE ONLY, LOCATIONS OF CONTROL JOINTS SHALL BE PER THE NATIONAL BRICK INDUSTRY ASSOCIATION GUIDELINES. S. THE LOCATIONS OF EXISTING UTILITIES HAVE BEEN PREPARED FROM DOCUMENTS PROVIDED BY THE OWNER AND MAY NOT REPRESENT THE ACTUAL FIELD CONDITIONS. CONTRACTOR TO REVIEW ALL OWNER DOCUMENTS AND BECOME FAMILIAR WITH ALL EXISTING UTILITIES. THE CONTRACTOR HAS THE RESPONSIBILITY TO VERIFY LOCATIONS IN THE FIELD BY EMPLOYING FIELD UTILITY LOCATING SERVICES BEFORE CONSTRUCTION STARTS, AND COORDINATE ALL NEW UTILITY LOCATIONS, CONNECTIONS AND PENETRATIONS. T. THE SUBCONTRACTOR SHALL VERIFY AND COORDINATE, WITH ALL TRADES, THE SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS, OR BASES AS WELL AS POWER, WATER, AND DRAIN INSTALLATIONS BEFORE PROCEEDING WITH WORK. SUBCONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES'WORK. ALL CONCERNS, SPACE LIMITATIONS OR STRUCTURAL CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT, PRIOR TO COMMENCING WITH THE WORK IN QUESTION. U. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CONFLICTS WITH CASEWORK, DOORS, AND OTHER TRADES. PROJECT INFORMATION PROJECT LOCATION: INTERSECTION OF CARMEL DRIVE AND RANGELINE ROAD - HAMILTON COUNTY, INDIANA PROJECT NAME: THE PROSCENIUM DEVELOPMENT - BUILDING 3 GOVERNING BUILDING CODE: 2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE) 2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE) PROJECT TYPE: NEW RESIDENTIAL UNIT BUILDING UNIT# UNITTYPE UNIT DES. UNIT (SF) A3 1 BR/1 BH 1,155 Bl 2 BR/2 BH 1,150 Bl 2 BR/2 SH 1,210 Al 1 BR/1 BH 778 Al 1 BR/1 SH 894 Bl 2 BR/2 SH 1,193 Al 1 BR/1 SH 792 Al 1BR/1 SH 905 Al 1 BR/1 SH 792 Al 1 BR/1 BH 824 Al 1 BR/1 BH 824 TOTAL 10,517 Ural Ir urvn ITrc unnI Lt urvn pry 401 A3 1 BR/1 BH 1,155 402 Bl 2 BR/2 BH 1,150 403 Bl 2 BR/2 SH 1,210 404 Al 1 BR/1 BH 778 405 Al 1 BR/1 SH 894 406 Bl 2 BR/2 SH 1193 407 Al 1 BR/1 SH 792 408 Al 1 BR/1 SH 905 409 Al 1 BR/1 SH 792 410 Al 1 BR/1 BH 824 411 Al 1 BR/1 BH 824 TOTAL 10,517 WOOLPERT ARCNITECTUREj_NGINEENNGI6Eftlyli 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E D C 4m A� E Own _0 l^'> W J ei a--r W U � UC K 0 O 73 c a m o` 0 C) mo €m NM n , c o o c G v U m � U /Issuances: 0.EV DESCM"M DATE 0 Issued For Building 3 Reviev 10/12/18 1 Issued For Buildi 3Permit O6/10/19 Prom. No.: 074904 Date: 10/12/18 A Sheet Name: COVER RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel DATE: 10/31/19 G3=000