HomeMy WebLinkAbout(04) C400O N O 0 y 00 3 v c o E a N � O M0 moU O �a o O 0 0 0 a EnY aG O c � c 0 00 N SANITARY STRUCTURE TABLE STRUCTURE ID DESCRIPTION RIM INVERT NOTES 4 EXISTING MANHOLE 821.83 8" - 820.64 (N) EX 8' OR 10' - 820.64 (N) 8' = 820.60 (W) EX 8' OR 10' - 820.60 (W) 5 SANITARY MANHOLE 832.13 8' = 823.02 (E) 8' - 822.64 (N) 6 SANITARY MANHOLE 837.06 8' = 826.19 (W) I ------------- I �T r II - -- ---t ----- - - - 15 Ij C81 CB2 / E3 Ha CBb 11 FrCfi 2 — — — — 4 11 - - - = --- _ �• _ - - - - -- UE --LIE - U --- --- - - e 4n. a /.. a .e .,.,,..e� . ®— ® ® — BUILDING 1 BUILDING 2 SAN✓3 �/II n A, � �- SA 6IH2 \\ \\ \\ \\ I I 1 11 TYP — — — — — — — — — — — — — OFFICE BUILDING ( RB w�a Tc e4s.35 / 3 � I $T" TC. 84776 CURB NLET Tc: 84764 C113 _-12"WTR------12"WTR------12''WTR------12 aTi- -----12"WTR------12'WTR---- CI14 -------------- \\I I RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel �VT\LJtOM4'YADA/� DATE: \ 10/31/19 MH15 3m BUILDING 4 FUTURE TAVERN J �R I 16 (10� 26 3 12 .I ID UILDING 5 I ID a IQ I 0L_ I3BUI(Show G 3 10 Is sanitary detail nne i -- 6fill- ------ SD- - - - - - 30"SD 0 ---12"WTR--- LEGEND ,OO;N\\\a1,.5M �C�ryGG TE - - - - - - - - - - - = W �B e U Z TYRO STORM SEWER \0P 166668m O 0 40 80 120 FOUNDATION DRAIN/UNDERDRNN STATE OF SAN {SAHRAAY SEWER MOUMF =41 GRAPHIC SCALE IN FEET 12 WrR WATER MAIN , 01111 AA ` — G G TELEPHONE 06/10/19 UTTELEPHONE {p I UE ELECTRIC HVE HIGH VOLTAGE ELECTRIC F F FIBER OPTIC EXISTING UTILITY _ TO BE ABANDONED L I CATCH BASIN/AREA DRAIN CURB INLET Z n z I , ENDWALL W a p CLFANOUT LLU d T MANHOLE 0: r0 r! .O. FIRE HYDRANT c a a WATER VALVE ftl 6 rn OX PROPOSED STORM I.D. C OPROPOSED SANITARY I.D. ? 4 u FUTURE CONSTRUCTION ^131 W ap w UTILITY KEYNOTES h o ❑ O o O RELOCATED WATER MAIN. 18 6' DOMESTIC WATER SERVICE W/ G _ - 4' METER AND RPZ GW FlRE O COMBINED DOMESTIC/PREVENIER INSIDE BUILDING / Z C PROTECTION WATER SERVICE. PROPOSED BUILDING STORM FIRE DEPARTMENT CONNECTION. 17 SERVICE (SEE PLUMBING PUNS). � 14 O ADJUST UTILITY STRUCTURE TO O RELOCATED PUBLIC WATER (BY FINISHED GRADE 18 OTHERS) Z O N 8' SANITARY SERVICE O 1.00E m I \ \ O (MIN). 19 SERVED FROM BUILDING Y 0 o O o 0 m \ PLUMBING SYSTEM. PRIVATE - w n g RELOCATED HIGH VOLTAGE PAINTED RED 4 \ ( O ELECTRIC (BY OTHERS). 0 1 N ❑ MH4/ 4 20 G I\\ O7 25, ELECTRIC EASEMENT. T-COUPLINREO'D TIE EX. DL O ❑ ❑ U J 6' C.P.P. NEW STORM ODISTRIBUTION CABINET. SEWER. (BY DUKE 8 8 (BY DUKE ENERGY) 21 PROPOSED INLETS / TOP OF PODIUM STRUCTURE.. (SEE RELOCATED OVERHEAD ELECTRIC. PLUMBING) 30 - - 30 10 TRANSFORMER BY DUKE ENERGY. m ' . C ea�s\�c O 22 0 ED IRE HYDRANT PROPS F _ N N 13 w aza sa - � )_ - � � - 11 PPoMARY ELECTRIC SERVICE ASSEMBLY � N 4 FOR we IT- 12 SEORDANY ELECTRIC SERVICE 23 EXTENSION SED 12" O.I. WATER MAN Z Ba CONNECT TO EXISTING UTILITY c 2 _ - - - - - - 13 PER AGENCY REQUIREMENTS. 24 PROVIDE 10'X10"X12" TEE o N PROPOSED UTILITY POLE AND O POST INDICATOR VALVE C p O2g FIRE SERVICE ENTRY WITH N N N 15 RPOLE DOUBLE CHECK DETECTOR RELOCATED LIGHT ASSEMBLY INSIDE BUILDING r m C LL �159'�8' SAN 0 2.00E F UTILITY NOTES I 1. ROOF DRAINS, FOUNDATION DRAINS, AND OTHER CLEAN WATER CONNECTIONS TO THE SANITARY SEWER SYSTEM ARE PROHIBITED. W w 2, SANITARY SEWER PIPE AND FITTINGS MAY BE EITHER PVC THAT CONFORMS TO \ a ASTM D-3034, STIR 35 WITH A MINIMUM CELL CLASSIFICATION R 12454-B, OR REINFORCED CONCRETE PIPE CLASS III, N. OR V IN ACCORDANCE WITH 00 J f- - AiANDAND AWWA DUCTILE- 51I OR HIGH DDEENSITYMING TO ANSI POL ETHYLENE PIPE PE O 0 CONFORMING TO ASTM-3350 CELL CLASS P.E. 3744 33C. O W tl I I 3. CONSTRUCTION SHALL NOT COMMENCE UNTIL AN IMPROVEMENT LOCATION PERMIT HAS BEEN OBTAINED. h I 4. WATER MAINS CROSSING ANY AND ALL SEWERS SHALL HAVE A MINIMUM U L _ VERTICAL SEPARATION OF 18' BETWEEN THE OUTSIDE OF THE WATER MAIN I PIPE AND THE SEWER PIPE. ONE FULL LENGTH OF WATER MAIN PIPE SHALL TRENCH DRAIN :62E.44 BE CENTERED AT THE POINT OF THE CROSSING SUCH THAT BOTH JOINTS W WILL BE EQUIDISTANT AND M FAR AWAY FROM THE SEWER AS POSSIBLE IF W - - - WATER UNE(5) F EITHER BELOW SAINFARY IRON SEWER OR OF, SEWER LINE MUST BI OR EQUIVALENT) OF R Thin DUCTILE IRON PIPING OR OF 200 psi PVC (SDR-21 _ I OR EQUNAI.ENn FOR TIMT PARTICULAR SPAN. 23 L TRENCH DRAIN e2e.65 5, EXISTING UNDERGROUND UTIUIES ME SHOWN IN THEIR APPROXIMATE L LOCATIONS ACCORDING TO THE BEST AVAILABLE INFORMATION. TIRE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF THE EXISTING UTILITIES AND REPAIRING ANY DAMAGE DONE TO THE J O 13 12mX8m REWCER UTILITIES DURING PROBING OR CONSTRUCTION. TO OBTAIN ACCURATE FIELD = Q LOCATIONS OF EXISTING UNDERGROUND UTILITIES, THE CONTRACTOR SHALL K NOTIFY THE FOLLOWING FORTY-EIGHT (48) HOURS IN ADVANCE: INDIANA J I UNDERGROUND CABLE LOCATION 1-100-382-5544. C m LU Z 8. ALL STORM AND SANITARY SEWER CONSTRUCTION SHALL BE PERFORMED IN C� Z r ACCORDANCE WITH CITY OF CARMEL STANDARDS AND SPECIFICATIONS. L T - 7. FIELD TILE ENCOUNTERED SHALL BE REPLACED AND/OR CONNECTED TO THE Z Q r r STORM SEWER SYSTEM. Z 2 4 2 III III 8. GRANULAR BACKFlLL IS REQUIRED FOR ALL PIPE UNDER PAVEMENT AND li = a I1 WTTAIN 5 FEET OF PAVEMENT. U O li — I \ 9. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AT HIS EXPENSE ALL AUTOMOBILE AND PEDESTRIAN TRAFFIC CONTROL DEVICES REQUIRED BY FEDERAL. STATE, COUNTY. CITY OR LOCAL AGENCY. WE AMOUNT. LOCATION AND SIZE SHALL BE PER DIRECTION OF AGENCY. 10. ALL SANITARY LATERALS SHALL BE 6' SDR-35 PVC O 1.00E MINIMUM SLOP ALL LATERALS SHALL MAINTAIN A MINIMUM OF 3' OF COVER FROM FINISHED GRADE TO TOP OF PIPE. V / O Li J LU `/ LU Q RD j UU Z J UU IX V J 11 A__ WATER BE PERFRMED CONSTRUCTION P CIFlCATIONSOAND IN = J Q ACCORDANCE�WITH CARMELR WATER STANDARD SN/STRUCTUE REQUIREMENTS, INCLUDING AS-BUILTS PROVIDED AT COMPIETION. WC U 12. ALL WATER MAIN BENDS, ELBOWS, TEES, VALVES AND HYDRANTS SHA1.1 HAVE W ---12"W - --I PROPER THRUST BLOCKING. C L 3 13. IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL Unni POLES SHALL BE LOCATED WITHIN ONE FOOT OF THE PROPOSED RIGHT-OF-WAY. _ v 14. SEE SHEET C101 FOR EXISTING STORM SEWER AND SANITARY STRUCTURE INFORMATION. 15. ALL STORM SEWERS WITHIN PUSUC RIGHT-R-WAY SHALL BE REINFORCED CONCRETE PIPE. C400