HomeMy WebLinkAbout(00) G2-0002
I
4
5
6
7
3
0
It At
F4
K
2
Q
N
rT
v
m'
v
0
rn
v
C
m
CL
E
0
.E
U
2
O
a a`
PROJECT TEAM
\1/
WOOLPERT
DES I GN I GELS PAT IAL I IN FRASTRUCTN RE
WOOLPERT
1203 Walnut Street, Second Floor
Cincinnati, OH 45202
Tel: 513.272.8300
Fax: 937.461.0743
www.woolpert.com
LOCATION MAP
na�Nlin'tl fmnNrale t�
C,
wnnrmwn
Car ell
Shepherd -- PROJECT
Herr Zionsville 7 SITE Fish P
mass on
p
J/ wooanury
Meridian dills �-I McLordeille
frater v
oaPa „
Nrr 6om
Gmms Near[-,} Pleavnr Cc'ea
Recen ry Rocky Ripple V
Mon N
I SPI,n91411 Ce ME Comfort
HI
J
Secretary
wanes Par ern
f1 ambrlann
Bale Indiana lis-�--I--
_ ire
Appear t.[
(qr
\111111
1
March Grove New Palestine
Harrell —" canollh
men
emsomnppn
IneMawaae
:"valley a
VICINITY MAP
up
QL
A Shrshornal
venne me sx.enm0 u, drip -
anane0r
s Exec"he or
ar IneRr= R s
w Carmel or "' €c£ _
�a ECarmel nich
x
aCoalD wcarmemr a ecarmemr
ee^ral xbaleecrack a PROJECT s
a
SITE
com,l
sex-sm.ase carte
Quail Glen Or
Gp anbe9se n
The Proscenium Development
BUILDING 2:
ISSUED FOR PERMIT
MAY 19 2019
PROJECT IMAGE
GENERAL NOTES
A. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD PRIOR TO ORDERING OR
FABRICATION OF MATERIALS OR THE BEGINNING OF CONSTRUCTION. NOTIFY ARCHITECT AND OWNER
REPRESENTATIVE OF ALL DISCREPANCIES. ALL WORK REQUIRING MEASURING TO BE DONE ACCORDING TO FIGURES
ON DRAWINGS. DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT AND OWNER REPRESENTATIVE. CONTRACTOR TO SUBMIT SPECIFIC
DISCREPANCY FOR ARCHITECT REVIEW, PRIOR TO COMMENCING WITH THE WORK IN QUESTION.
B. ALL WORK TO CONFORM TO LOCAL CODES, ORDINANCES AND REQUIREMENTS.
C. THE CONTRACTOR SHALL ARRANGE FOR THE PREMISES TO BE MAINTAINED IN AN ORDERLY MANNER, FREE OF DUST
AND DEBRIS,THROUGHOUT THE COURSE OF THE WORK. PROVIDE AND MAINTAIN TEMPORARY BARRICADES AS
REQUIRED TO PROTECT THE PUBLIC AND OWNERS PERSONNEL DURING CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING STRUCTURE OR EQUIPMENT. ANY SUCH DAMAGE SHALL BE
REPAIRED AT THE CONTRACTOR'S EXPENSE.
D. CONTRACTOR SHALL PROVIDE DAILY OR MORE FREQUENT GENERAL CLEAN UP IN COMPLIANCE WITH OWNER'S
REQUIREMENTS OF AREAS WITHIN THE LIMITS OF CONSTRUCTION, AND FINAL CLEAN UP AT CONCLUSION OF WORK.
E. CONTRACTOR TO REVIEW OTHER DRAWINGS ISSUED FOR THIS PROJECT FOR ADDITIONAL INFORMATION FROM OTHER
TRADES TO COORDINATE THE REQUIRED SCOPE OF WORK.
F. DO NOT SCALE FROM THE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE. THE OWNER'S
REPRESENTATIVE MUST BE NOTIFIED OF ANY CONFLICTS IN DIMENSIONING.
G. EXTERIOR DIMENSIONS ARE TO FACE OF BRICK VENEER OR FACE OF METAL STUD, BRICK VENEER, MASONRY OPENING,
OR COLUMN CENTERLINE UNLESS OTHERWISE NOTED. INTERIOR DIMENSIONS ARE TO FACE OF EXTERIOR STUD, FACE
OF MASONRY, FACE OF CONCRETE, CENTERLINE OF COLUMNS, OR FACE OF INTERIOR STUD UNLESS OTHERWISE
NOTED.
H. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE NEW AND AS
SPECIFIED, UNLESS IDENTIFIED OTHERWISE.
I. ALL NEW FINISHED AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF IMPERFECTIONS AND IN
PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS SHALL MATCH THE ADJACENT MATERIALS
CONSTRUCTION AND FINISH.
J. ALL FLOORS ON EITHER SIDE OF A DOORWAY OR OPENING SHALL BE LEVEL AND HAVE MAXIMUM ELEVATION
DIFFERENCE OR THRESHOLD HEIGHT OF 12".
K. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE 4" FROM THE FACE OF STUD TO FACE OF STUD OF DOOR
FRAME JAMB UNLESS NOTED OTHERWISE.
L. DOOR SIZES, STYLES, AND SPECIFICATIONS, ROUGH OPENING SIZES AND EXACT LOCATIONS TO BE CHECKED AND
VERIFIED BY THE CONTRACTOR BEFORE ORDERING AND BEFORE CONSTRUCTION BEGINS.
M. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS AND CEILINGS TO BE SEALED WITH PROPER APPROVED
MATERIALS TO THE FULL THICKNESS OF THE CONSTRUCTION ELEMENTS.
N. FIRE STOP ALL FLOORS, WALLS AND CEILINGS AS REQUIRED BY APPLICABLE CODE.
O. ALL WOOD BLOCKING IN EXTERIOR WALLS TO BE MOISTURE RESISTANT TREATED IN ACCORDANCE WITH
SPECIFICATIONS. WHERE REQUIRED BY CODE, ALL WOOD BLOCKING IN INTERIOR WALLS TO BE FIRE RETARDANT
TREATED IN ACCORDANCE WITH SPECIFICATIONS.
P. INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW
WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO MATCH ARCHITECT'S SAMPLE.
COLOR REQUIRES ARCHITECT'S APPROVAL.
Q. PROVIDE FIRE EXTINGUISHER COMPLYING WITH NFPA 10, AS INDICATED ON LIFE SAFETY DRAWINGS WITH MAX TRAVEL
DISTANCE OF 75'.
R. MASONRY CONTROL JOINTS ARE SHOWN FOR REFERENCE ONLY LOCATIONS OF CONTROL JOINTS SHALL BE PER THE
NATIONAL BRICK INDUSTRY ASSOCIATION GUIDELINES.
S. THE LOCATIONS OF EXISTING UTILITIES HAVE BEEN PREPARED FROM DOCUMENTS PROVIDED BY THE OWNERAND MAY
NOT REPRESENT THE ACTUAL FIELD CONDITIONS. CONTRACTOR TO REVIEW ALL OWNER DOCUMENTS AND BECOME
FAMILIAR WITH ALL EXISTING UTILITIES. THE CONTRACTOR HAS THE RESPONSIBILITY TO VERIFY LOCATIONS IN THE
FIELD BY EMPLOYING FIELD UTILITY LOCATING SERVICES BEFORE CONSTRUCTION STARTS, AND COORDINATE ALL NEW
UTILITY LOCATIONS, CONNECTIONS AND PENETRATIONS.
T. THE SUBCONTRACTOR SHALL VERIFY AND COORDINATE, WITH ALL TRADES, THE SIZES AND LOCATIONS OF ALL
OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS, OR BASES AS WELL AS
POWER, WATER, AND DRAIN INSTALLATIONS BEFORE PROCEEDING WITH WORK. SUBCONTRACTOR SHALL PROVIDE
COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ALL CONCERNS, SPACE LIMITATIONS OR
STRUCTURAL CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT, PRIOR TO
COMMENCING WITH THE WORK IN QUESTION.
U. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE
RECEPTACLES, SWITCHES, ETC. TO AVOID CONFLICTS WITH CASEWORK, DOORS, AND OTHER TRADES.
PROJECT INFORMATION
PROJECT LOCATION:
INTERSECTION OF CARMEL DRIVE AND RANGELINE ROAD - HAMILTON
COUNTY, INDIANA
PROJECT NAME:
THE PROSCENIUM DEVELOPMENT - BUILDING 2
GOVERNING BUILDING CODE:
2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE)
2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE)
PROJECT TYPE:
NEW RESIDENTIAL UNIT BUILDING
Meelpal0r
FtanaW,
BUILDING
TA
B
U
LAT
I O
N
WngNlrrtG,caalry e
re
•roast°"^'°
BUILDING 2 SUMMARY
UNIT(SF)
QUANTITIES
UNIT#
UNITTYPE
UNITDES.
UNIT#
UNIT TYPE
UNIT DES.
UNIT (SF)
UNIT#
UNITTYPE
UNIT DES.
UNIT (SF)
UNIT#
UNITTYPE
UNIT DES.
UNIT (SF)
—
-
FLOOR
UNITS/FLOOR
NET UNIT SF
B2-A1
B2-A2
B2-A3
B2-A4
B2-N39
CORRIDOR (SF)
STAIR (SF)
MECH/UTILITY (SF)
105
Al
1 BR/1 BH
798
201
B2
2 BR/2 BH
1,398
301
B2
2 BR/2 BH
1,399
401
B2
2 BR/2 BH
1,398
P
1
12
10,625
4
4
0
1
2,123
399
50
106
A2
1 BR/1 BH
808
202
B2
2 BR/2 BH
1,413
302
B2
2 BR/2 BH
1,410
402
B2
2 BR/2 BH
1,408
2
16
15,758
4
4
1
1
2,335
399
50
107
Al
1BR/1 BH
792
203
B1
2BR/2 BH
1,191
303
B1
2BR/2 BH
1,187
403
B1
2BR/2 BH
1,177
e nara sr Cuero sl•
ensms
ensm sl
f
3
16
15,506
4
4
1
1
2,329
620
50
108
A2
1 BR/l BH
801
204
A3
1 BR/l BH
1,132
304
A2
1 BR/l BH
910
404
A2
1 BR/l BH
912
In
-
-41
4
4
4,895
0
1
0
0
809
422
N/A
109
Bl
2 BR/2 BH
1,165
205
Al
1 BR/l BH
797
305
Al
1 BR/l BH
793
TOTAL
4,895
4*
TOTAL
48
46,784
12
13
2
3
7,596
1,840
150
110
A2
1 BR/l BH
880
206
A2
1 BR/l BH
800
306
A2
1 BR/l BH
799
ill
Al
1 BR/i BH
942
207
Al
1 BR/i BH
797
307
Al
1 BR/i BH
794
113
Al
1 BR/1 BH
821
208
A2
1 BR/1 BH
800
308
A2
1 BR/1 BH
798
114
A2
1 BR/1 BHj10,625
874
209
B1
2 BR/2 BH
1,167
309
B1
1 BR/1 BH
1,166
115
61
2 BR/2 BH185
210
A2
1 BR/1 BH
860
310
A2
2 BR/2 BH
882
116
A4
1 BR/1 BH797
211
Al
1 BR/1 BH
831
311
Al
1 BR/1 BH
833
117
AS
1 BR/1 BH862
212
A2
1 BR/l BH
872
312
A2
2 BR/2 BH
866
TOTAL
213
Al
1 BR/1 BH
829
313
Al
1 BR/1 BH
832
214
A4
1 BR/1 BH
809
314
A4
1 BR/1 BH
799
215
Bl
2 BR/2 BH
1,167
315
Bl
2 BR/2 BH
1,164
217
A5
1 BR/1 BH
875
317
A5
1 BR/1 BH
874
TOTAL
150758
TOTAL
15,506
u
F
E
u
Ky
S6�
VzWbl � E
•RENITEtTI@E loan I NEERINGIGEOSPATILL
7635 Interactive Way
Suite 100
Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
E
cam
_0
W
U
J•�
J
W
y--r
af
rUn
V /03
c
o
O
c
Q)
0
N
EIt
m
`mv
W
C
m
`o c
EO
C 9
C
L
U
E2 a
`=€
m
E
�U
Q Issuances:
REv
DMMIKIM
mm
0
Issued For Building 2 Review
10/05/18
1
Issued For Building 2Permit
05r01/19
Prom. No.: 074904
Date: 10/05/18
A Sheet Name:
COVER SHEET
RELEAS
St
:0 FOR CONSTRUCTION
Plate c as.""t, " ,a"ll"
of State and Local Codes
City of Carrnel
DATE: 10/31/19