Loading...
HomeMy WebLinkAbout(00) G2-0002 I 4 5 6 7 3 0 It At F4 K 2 Q N rT v m' v 0 rn v C m CL E 0 .E U 2 O a a` PROJECT TEAM \1/ WOOLPERT DES I GN I GELS PAT IAL I IN FRASTRUCTN RE WOOLPERT 1203 Walnut Street, Second Floor Cincinnati, OH 45202 Tel: 513.272.8300 Fax: 937.461.0743 www.woolpert.com LOCATION MAP na�Nlin'tl fmnNrale t� C, wnnrmwn Car ell Shepherd -- PROJECT Herr Zionsville 7 SITE Fish P mass on p J/ wooanury Meridian dills �-I McLordeille frater v oaPa „ Nrr 6om Gmms Near[-,} Pleavnr Cc'ea Recen ry Rocky Ripple V Mon N I SPI,n91411 Ce ME Comfort HI J Secretary wanes Par ern f1 ambrlann Bale Indiana lis-�--I-- _ ire Appear t.[ (qr \111111 1 March Grove New Palestine Harrell —" canollh men emsomnppn IneMawaae :"valley a VICINITY MAP up QL A Shrshornal venne me sx.enm0 u, drip - anane0r s Exec"he or ar IneRr= R s w Carmel or "' €c£ _ �a ECarmel nich x aCoalD wcarmemr a ecarmemr ee^ral xbaleecrack a PROJECT s a SITE com,l sex-sm.ase carte Quail Glen Or Gp anbe9se n The Proscenium Development BUILDING 2: ISSUED FOR PERMIT MAY 19 2019 PROJECT IMAGE GENERAL NOTES A. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN THE FIELD PRIOR TO ORDERING OR FABRICATION OF MATERIALS OR THE BEGINNING OF CONSTRUCTION. NOTIFY ARCHITECT AND OWNER REPRESENTATIVE OF ALL DISCREPANCIES. ALL WORK REQUIRING MEASURING TO BE DONE ACCORDING TO FIGURES ON DRAWINGS. DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND OWNER REPRESENTATIVE. CONTRACTOR TO SUBMIT SPECIFIC DISCREPANCY FOR ARCHITECT REVIEW, PRIOR TO COMMENCING WITH THE WORK IN QUESTION. B. ALL WORK TO CONFORM TO LOCAL CODES, ORDINANCES AND REQUIREMENTS. C. THE CONTRACTOR SHALL ARRANGE FOR THE PREMISES TO BE MAINTAINED IN AN ORDERLY MANNER, FREE OF DUST AND DEBRIS,THROUGHOUT THE COURSE OF THE WORK. PROVIDE AND MAINTAIN TEMPORARY BARRICADES AS REQUIRED TO PROTECT THE PUBLIC AND OWNERS PERSONNEL DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING STRUCTURE OR EQUIPMENT. ANY SUCH DAMAGE SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. D. CONTRACTOR SHALL PROVIDE DAILY OR MORE FREQUENT GENERAL CLEAN UP IN COMPLIANCE WITH OWNER'S REQUIREMENTS OF AREAS WITHIN THE LIMITS OF CONSTRUCTION, AND FINAL CLEAN UP AT CONCLUSION OF WORK. E. CONTRACTOR TO REVIEW OTHER DRAWINGS ISSUED FOR THIS PROJECT FOR ADDITIONAL INFORMATION FROM OTHER TRADES TO COORDINATE THE REQUIRED SCOPE OF WORK. F. DO NOT SCALE FROM THE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE. THE OWNER'S REPRESENTATIVE MUST BE NOTIFIED OF ANY CONFLICTS IN DIMENSIONING. G. EXTERIOR DIMENSIONS ARE TO FACE OF BRICK VENEER OR FACE OF METAL STUD, BRICK VENEER, MASONRY OPENING, OR COLUMN CENTERLINE UNLESS OTHERWISE NOTED. INTERIOR DIMENSIONS ARE TO FACE OF EXTERIOR STUD, FACE OF MASONRY, FACE OF CONCRETE, CENTERLINE OF COLUMNS, OR FACE OF INTERIOR STUD UNLESS OTHERWISE NOTED. H. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE NEW AND AS SPECIFIED, UNLESS IDENTIFIED OTHERWISE. I. ALL NEW FINISHED AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF IMPERFECTIONS AND IN PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS SHALL MATCH THE ADJACENT MATERIALS CONSTRUCTION AND FINISH. J. ALL FLOORS ON EITHER SIDE OF A DOORWAY OR OPENING SHALL BE LEVEL AND HAVE MAXIMUM ELEVATION DIFFERENCE OR THRESHOLD HEIGHT OF 12". K. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE 4" FROM THE FACE OF STUD TO FACE OF STUD OF DOOR FRAME JAMB UNLESS NOTED OTHERWISE. L. DOOR SIZES, STYLES, AND SPECIFICATIONS, ROUGH OPENING SIZES AND EXACT LOCATIONS TO BE CHECKED AND VERIFIED BY THE CONTRACTOR BEFORE ORDERING AND BEFORE CONSTRUCTION BEGINS. M. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS AND CEILINGS TO BE SEALED WITH PROPER APPROVED MATERIALS TO THE FULL THICKNESS OF THE CONSTRUCTION ELEMENTS. N. FIRE STOP ALL FLOORS, WALLS AND CEILINGS AS REQUIRED BY APPLICABLE CODE. O. ALL WOOD BLOCKING IN EXTERIOR WALLS TO BE MOISTURE RESISTANT TREATED IN ACCORDANCE WITH SPECIFICATIONS. WHERE REQUIRED BY CODE, ALL WOOD BLOCKING IN INTERIOR WALLS TO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH SPECIFICATIONS. P. INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO MATCH ARCHITECT'S SAMPLE. COLOR REQUIRES ARCHITECT'S APPROVAL. Q. PROVIDE FIRE EXTINGUISHER COMPLYING WITH NFPA 10, AS INDICATED ON LIFE SAFETY DRAWINGS WITH MAX TRAVEL DISTANCE OF 75'. R. MASONRY CONTROL JOINTS ARE SHOWN FOR REFERENCE ONLY LOCATIONS OF CONTROL JOINTS SHALL BE PER THE NATIONAL BRICK INDUSTRY ASSOCIATION GUIDELINES. S. THE LOCATIONS OF EXISTING UTILITIES HAVE BEEN PREPARED FROM DOCUMENTS PROVIDED BY THE OWNERAND MAY NOT REPRESENT THE ACTUAL FIELD CONDITIONS. CONTRACTOR TO REVIEW ALL OWNER DOCUMENTS AND BECOME FAMILIAR WITH ALL EXISTING UTILITIES. THE CONTRACTOR HAS THE RESPONSIBILITY TO VERIFY LOCATIONS IN THE FIELD BY EMPLOYING FIELD UTILITY LOCATING SERVICES BEFORE CONSTRUCTION STARTS, AND COORDINATE ALL NEW UTILITY LOCATIONS, CONNECTIONS AND PENETRATIONS. T. THE SUBCONTRACTOR SHALL VERIFY AND COORDINATE, WITH ALL TRADES, THE SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS, OR BASES AS WELL AS POWER, WATER, AND DRAIN INSTALLATIONS BEFORE PROCEEDING WITH WORK. SUBCONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ALL CONCERNS, SPACE LIMITATIONS OR STRUCTURAL CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT, PRIOR TO COMMENCING WITH THE WORK IN QUESTION. U. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CONFLICTS WITH CASEWORK, DOORS, AND OTHER TRADES. PROJECT INFORMATION PROJECT LOCATION: INTERSECTION OF CARMEL DRIVE AND RANGELINE ROAD - HAMILTON COUNTY, INDIANA PROJECT NAME: THE PROSCENIUM DEVELOPMENT - BUILDING 2 GOVERNING BUILDING CODE: 2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE) 2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE) PROJECT TYPE: NEW RESIDENTIAL UNIT BUILDING Meelpal0r FtanaW, BUILDING TA B U LAT I O N WngNlrrtG,caalry e re •roast°"^'° BUILDING 2 SUMMARY UNIT(SF) QUANTITIES UNIT# UNITTYPE UNITDES. UNIT# UNIT TYPE UNIT DES. UNIT (SF) UNIT# UNITTYPE UNIT DES. UNIT (SF) UNIT# UNITTYPE UNIT DES. UNIT (SF) — - FLOOR UNITS/FLOOR NET UNIT SF B2-A1 B2-A2 B2-A3 B2-A4 B2-N39 CORRIDOR (SF) STAIR (SF) MECH/UTILITY (SF) 105 Al 1 BR/1 BH 798 201 B2 2 BR/2 BH 1,398 301 B2 2 BR/2 BH 1,399 401 B2 2 BR/2 BH 1,398 P 1 12 10,625 4 4 0 1 2,123 399 50 106 A2 1 BR/1 BH 808 202 B2 2 BR/2 BH 1,413 302 B2 2 BR/2 BH 1,410 402 B2 2 BR/2 BH 1,408 2 16 15,758 4 4 1 1 2,335 399 50 107 Al 1BR/1 BH 792 203 B1 2BR/2 BH 1,191 303 B1 2BR/2 BH 1,187 403 B1 2BR/2 BH 1,177 e nara sr Cuero sl• ensms ensm sl f 3 16 15,506 4 4 1 1 2,329 620 50 108 A2 1 BR/l BH 801 204 A3 1 BR/l BH 1,132 304 A2 1 BR/l BH 910 404 A2 1 BR/l BH 912 In - -41 4 4 4,895 0 1 0 0 809 422 N/A 109 Bl 2 BR/2 BH 1,165 205 Al 1 BR/l BH 797 305 Al 1 BR/l BH 793 TOTAL 4,895 4* TOTAL 48 46,784 12 13 2 3 7,596 1,840 150 110 A2 1 BR/l BH 880 206 A2 1 BR/l BH 800 306 A2 1 BR/l BH 799 ill Al 1 BR/i BH 942 207 Al 1 BR/i BH 797 307 Al 1 BR/i BH 794 113 Al 1 BR/1 BH 821 208 A2 1 BR/1 BH 800 308 A2 1 BR/1 BH 798 114 A2 1 BR/1 BHj10,625 874 209 B1 2 BR/2 BH 1,167 309 B1 1 BR/1 BH 1,166 115 61 2 BR/2 BH185 210 A2 1 BR/1 BH 860 310 A2 2 BR/2 BH 882 116 A4 1 BR/1 BH797 211 Al 1 BR/1 BH 831 311 Al 1 BR/1 BH 833 117 AS 1 BR/1 BH862 212 A2 1 BR/l BH 872 312 A2 2 BR/2 BH 866 TOTAL 213 Al 1 BR/1 BH 829 313 Al 1 BR/1 BH 832 214 A4 1 BR/1 BH 809 314 A4 1 BR/1 BH 799 215 Bl 2 BR/2 BH 1,167 315 Bl 2 BR/2 BH 1,164 217 A5 1 BR/1 BH 875 317 A5 1 BR/1 BH 874 TOTAL 150758 TOTAL 15,506 u F E u Ky S6� VzWbl � E •RENITEtTI@E loan I NEERINGIGEOSPATILL 7635 Interactive Way Suite 100 Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 E cam _0 W U J•� J W y--r af rUn V /03 c o O c Q) 0 N EIt m `mv W C m `o c EO C 9 C L U E2 a `=€ m E �U Q Issuances: REv DMMIKIM mm 0 Issued For Building 2 Review 10/05/18 1 Issued For Building 2Permit 05r01/19 Prom. No.: 074904 Date: 10/05/18 A Sheet Name: COVER SHEET RELEAS St :0 FOR CONSTRUCTION Plate c as.""t, " ,a"ll" of State and Local Codes City of Carrnel DATE: 10/31/19