LIFE SAFETY LEGEND
9
2
D_
F:
00
2
Q
N
m
75
3
DO
CID
O
m
v
C
m
E
0
.E
0
N
0-
BUILDING CODES REFERENCED
2014 INDIANA BUILDING CODE (2012 IBC, 1 ST PRINTING)
2012 INDIANA PLUMBING CODE
2014 INDIANA MECHANICAL CODE (2012 IMC, 1ST PRINTING)
2014 INDIANA FIRE CODE (20121FC, 1ST PRINTING)
2009 INDIANA ELECTRICAL CODE (NFPA 70-2008)
ASHRAE 90.1-2007 EDITION
ANSI At 17.1-2009
DESCRIPTION
WOOD FRAMED CONSTRUCTION WITH A COMBINATION OF
MASONRY, CEMENT FIBER BOARD AND EXTERIOR
INSULATED FINISH SYSTEM. STEEL FRAMED
CONSTRUCTION WITH SPRAY -APPLIED FIRE -PROOFING ON
FIRST FLOOR NORTH END.
TYPE R-2 PRIMARY OCCUPANCY
TYPE V-A CONSTRUCTION
FOUR STORYAPARTMENT BUILDING
BUILDING AREA
BUILDING 2
FIRST FLOOR-
19,465 GSF
SECOND FLOOR-
19,465 GSF
THIRD FLOOR-
19.465 GSF
FOURTH FLOOR-
6,597 GSF
TOTAL-
64,992 GSF
RELEASED FOR CONSTRUCTION
AUTOMATIC FIRE SUPPRESSION SYSTEM
BUILDING IS REQUIRED TO HAVE AND IS PROVIDED
THROUGHOUT WITH AUTOMATIC SPRINKLER SYSTEM IN
ACCORDANCE WITH NFPA 13R AND IBC 903.3.1.2.
FIRE EXTINGUISHERS
FIRE EXTINGUISHER CABINETS AT 75' MAX TRAVEL.
FIRE ALARM SYSTEM
COMPLETE FIRE ALARM SYSTEM REQUIRED AND
PROVIDED IN ACCORDANCE WITH NFPA 72 AND IBC.
PROVIDE VISUAL NOTIFICATION (STROBES) IN ACCESSIBLE
UNITS IN ACCORDANCE WITH NFPA 72.
CODE DATA -INTERNATIONAL BUILDING CODE
OCCUPANCYGROUP
SECTION 310.3 OCCUPANCY
R2 OCCUPANCY; (RESIDENTIAL, APARTMENT)
M MERCANTILE (RETAIL)
B BUSINESS (OFFICES)
SEPARATED MIXED USE PER IBC 508;
OCCUPANCY SEPARATIONS INDICATED ON FLOOR PLAN
SECTION 510. SPECIAL PROVISIONS
HORIZONTAL SEPARATIONS MUST COMPLY WITH THE
FOLLOWING:
3-HR FIRE RESISTANCE RATING
• THE BUILDING BELOW IS NOT GREATER THAN ONE
STORY ABOVE GRADE
• THE BUILDING BELOW IS OF TYPE 1A CONSTRUCTION
• ANY SHAFT, STAIRWAYS, RAMP, OR ESCALATOR MUST
BE IN A 2-HOUR RATED ENCLOSURE
• THE BUILDING BELOW IS PROTECTED BY AN
AUTOMATIC FIRE SPRINKLER SYSTEM, PER NFPA 13
SECTION 510.9 MULTIPLE BUILDINGS ABOVE A
HORIZONTAL ASSEMBLY SHALL BE REGARDED AS
SEPARATE BUILDINGS.
BUILDING 2
EQUIPPED WITH NFPA 13R SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.2
TABLE 601
CONSTRUCTION TYPE: V-A
SECTION 708
FIRE BLOCKING REQUIRED
SECTION 718.3.2
DRAFTSTOPPING REQUIRED IN FLOORS, AT EVERY SLEEPING UNIT
SECTION 718.4.2
DRAFTSTOPPING IN ATTICS: REQUIRED, EVERY 3,000 SFQ
SECTION 903.2.8
GROUP R- AUTOMATIC SPRINKLER SYSTEM NFPA I3R REQUIRED.
SECTION 1009
STAIRWAYS- EXCEPTIONS TAKEN, SEE DRAWING NOTES
SECTION 1023
STAIRWAYS- ENCLOSURE MINIMUM OF 2HR RATING
SECTION
SMOKEPROOF ENCLOSURES- NOT REQ. WHERE TOP FLOOR IS
1023.11
LESS THAN 75 FT ABOVE FIRE DEPARTMENT ACCESS. (FLOOR
LEVEL OF FOURTH FLOOR IS 37'-D"
CONCEALED SPACES
IBC 718 AND NFPA 13
A. FIREBLOCKING: REQUIRED, BOTH VERTICAL AND HORIZONTAL
10' INTERVALS BEHIND TRIM FINISHES.
FIRE BLOCKING SHALL CONSIST OF ONE OF THE FOLLOWING: APPROVED
NONCOMBUSTIBLE MAT 2" OR (2) 1" LUMBER W/BROKEN LAP JOINTS, 1 23/'32" WOOD
STRUCTURAL PANEL W/JOINTS BACKED BY 23/32" STRUCTURAL PANEL OR 2X LUMBER.
B. DRAFTSTOPPING IN FLOORS: PER IBC 718.3.
C. DRAFTSTOPPING IN ATTIC: PER IBC 718.4.2.
PENETRATIONS THROUGH FIRE RATED ASSEMBLIES
A. REFER TO SECTION 714
EXIT SIGNS & EMERGENCY LIGHTING
EXIT SIGNS PROVIDED PER IBC 1013, INTERNAL BATTERY BACKUP. FLOOR -LEVEL EXITS
SIGNS PROVIDED PER IBC 1013.2.
MEANS OF EGRESS ILLUMINATION AND EMERGENCY LIGHTING PROVIDED PER IBC 1008.
ELEVATOR
REQUIRED TO MEET ASME A17.1
FOURTH FLOOR LIFE SAFETY PLAN
SCALE : T32" - V-O"
Subject to compliance with all regulations 3CALE: 3(32"=l'-O"
of State and Local Codes
City of Carmel
STAIR B
EXIT 8
0.3"
0'2pp
U
160
48"
170
34"
R LIFE SAFETY PLAN
BUILDING HEIGHT AND AREA BUILDINGS 2
REQUIREMENT
ALLOWABLE
ACTUAL
NO. OF STORIES -SECTION 504.2
4 STORIES W SPRINKLER
4 STORIES W SPRINKLER
AREA -SECTION 506.2
21,000 SF PER FLOOR
19,465 SF PER FLOOR MAX
SECTION 504.2
60' W SPRINKLER
48'-0"
CORRIDOR WIDTH
44"MIN
60" MIN
EGRESS DOOR SIZE
32" MIN
32" MIN PROVIDED
MEANS OF EGRESS BUILDING 2
REQUIREMENT
REQUIRED
PROVIDED
NUMBER OF EXITS
2 PER FLOOR
2 PER FLOOR
STAIR WIDTH
440MIN
48"WIDTH PROVIDED
CORRIDOR WIDTH
440MIN
60"MIN
EGRESS DOOR SIZE
32" MIN
32" MIN PROVIDED
TABULAR OCCUPANT LOAD, BUILDING 2 (IBC 1004.1.2)
FLOOR
OCC. TYPE
AREA(SF)
FACTOR
(SF/PERSON)
OCC.LOAD
(PERSONS)
FIRST
BUSINESS
5,270 SF
1/100 GROSS
53
RESIDENTIAL
10.978 SF
1/200 GROSS
55
MERCANTILE
1,805 SF
1/60 GROSS
31
MECHANICAL
41SF
1/300 GROSS
1
SECOND
RESIDENTIAL
18.978 SF
11200 GROSS
95
STORAGE
25SF
MOO GROSS
1
MECHANICAL
41SF
1/300 GROSS
1
THIRD
RESIDENTIAL
18,565 SF
1/200 GROSS
93
STORAGE
25 SF
1/300 GROSS
1
MECHANICAL
41SF
1/300 GROSS
1
FOURTH
RESIDENTIAL
5,970 SF
1/200 GROSS
30
BUILDING TOTAL
362
FIRE RESISTIVE RATINGS TABLE 601
STRUCTURAL ELEMENT
F.R. RATING
F.R. RATING
DESIGN NUMBER
PER CODE
PER DESIGN
STRUCTURALFRAME
FLOOR&BEAM
1HOUR
1HOUR
U.L.#D902
COLUMNS
1HOUR
1HOUR
U.L. #X752 & M29
BEARING WALLS (V-A)
EXT. WALLS (R2)
1HOUR
1HOUR
U.L. #U356
INT. WALLS
1HOUR
1HOUR
U.L. #U305
CORRIDOR WALLS (112)
30 MIN
1HOUR
U.L. #U311
OPENING PROTECTION
20 MIN
20 MIN
GUESTROOM SEPARATION
1HOUR
1HOUR
U.L.#U311
OPENING PROTECTION
45 MIN
60 MIN
STAIR (INT. WALLS)
2 HOUR
2 HOUR
U.L. #U301
STAIR (EXT. WALLS)
1HOUR
1HOUR
U.L. #U356
OPENING PROTECTION
90 MIN
90 MIN
ELEVATORS
2 HOUR
2 HOUR
U.L. #U906
OPENING PROTECTION
90 MIN
90 MIN
---
CEILING
-
-
---
STORAGEM1ECH
1 HOUR
1 HOUR
U.L. #U305
FLOOR -CEILING
1HOUR
IHOUR
U.L.#L521
ROOF - CEILING @ STAIR
ROOF -CEILING
1HOUR
1HOUR
U.L.#P522
SHAFT
1HOUR
1HOUR
U.L. #U305
STAIR A
0.31113
16O
48"
STAIR
C
0.3"
2
160
48"
NON -RATED, 2012 IBC SECTION 1009.3, EXCEPTION 1
STAIR C
0.3'
12
160
48"
NON -RATED, 2012 IBC SECTION 1009.3, EXCEPTION 1
11
EGRESS ELEMENT
ACTUAL OCCUPANTS
PERSONS
ACTUAL CLEAR
WIDTH (PROVIDED)
EGRESS CAPACITY
(PERSONS)
CAPACITY FACTOR
—..---- 2HOUR RATED
FIRE BARRIER
1 HOUR RATED
�0�*iIIIIIIIi FIRE BARRIER
EXIT
EXIT SIGN - SEE
ELECTRICAL
SPACE AREA
FUNCTION OF SPACE
BUSINESS
6000 SF
B
OCCUPANCY
1 t 100 60
2
CLASSIFICATION
NUMBER OF REQUIRED
EXITS
NUMBER OF OCCUPANTS
REQUIRED S.F. PER
OCCUPANT
♦_________ COMMON PATH
OF TRAVEL
TRAVEL DENOTES EXIT
DISTANCE ROUTE
100'-6"
L START DENOTES EXIT
POINT DISCHARGE
SEMI -RECESSED PORTABLE FIRE
FEC EXTINGUISHER CABINET WITH
PORTABLE FIRE EXTINGUISHER PER
NFPA 72 AS SELECTED BY LOCAL FIRE
MARSHALL. REFER TO DETAIL 10/A-602.
FE WALL MOUNTED PORTABLE FIRE
EXTINGUISHER PER NFPA 72 AS
SELECTED BY LOCAL FIRE MARSHALL.
WOULPERT
AACHITEULME ENG I NEERINGjGEOSPATIAL
7635 Interactive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
�7
IND
[e]
uj
U
J
J
0
Cape
N Eo
`mv
� U �
C: `om
c
o c
U
N N
w E
v
m � U
Qlssuances:
REv
DESM"ON
Mrs
0
Issued For Building 2 Review
1005/18
1
ASI#4
12/21/18
2
Issued For Building 2Permit
05/01/19
Prom. No.: 074904
Date: 10/05/18
A Sheet Name:
THIRD AND FOURTH
FLOOR LIFE SAFETY
PLANS
LS2=102
DATE: 10/31/19