HomeMy WebLinkAbout(07) LS2-102E 3 0 5 7 0 LIFE SAFETY LEGEND 9 2 D_ F: 00 2 Q N m 75 3 DO CID O m v C m E 0 .E 0 N 0- BUILDING CODES REFERENCED 2014 INDIANA BUILDING CODE (2012 IBC, 1 ST PRINTING) 2012 INDIANA PLUMBING CODE 2014 INDIANA MECHANICAL CODE (2012 IMC, 1ST PRINTING) 2014 INDIANA FIRE CODE (20121FC, 1ST PRINTING) 2009 INDIANA ELECTRICAL CODE (NFPA 70-2008) ASHRAE 90.1-2007 EDITION ANSI At 17.1-2009 DESCRIPTION WOOD FRAMED CONSTRUCTION WITH A COMBINATION OF MASONRY, CEMENT FIBER BOARD AND EXTERIOR INSULATED FINISH SYSTEM. STEEL FRAMED CONSTRUCTION WITH SPRAY -APPLIED FIRE -PROOFING ON FIRST FLOOR NORTH END. TYPE R-2 PRIMARY OCCUPANCY TYPE V-A CONSTRUCTION FOUR STORYAPARTMENT BUILDING BUILDING AREA BUILDING 2 FIRST FLOOR- 19,465 GSF SECOND FLOOR- 19,465 GSF THIRD FLOOR- 19.465 GSF FOURTH FLOOR- 6,597 GSF TOTAL- 64,992 GSF RELEASED FOR CONSTRUCTION AUTOMATIC FIRE SUPPRESSION SYSTEM BUILDING IS REQUIRED TO HAVE AND IS PROVIDED THROUGHOUT WITH AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13R AND IBC 903.3.1.2. FIRE EXTINGUISHERS FIRE EXTINGUISHER CABINETS AT 75' MAX TRAVEL. FIRE ALARM SYSTEM COMPLETE FIRE ALARM SYSTEM REQUIRED AND PROVIDED IN ACCORDANCE WITH NFPA 72 AND IBC. PROVIDE VISUAL NOTIFICATION (STROBES) IN ACCESSIBLE UNITS IN ACCORDANCE WITH NFPA 72. CODE DATA -INTERNATIONAL BUILDING CODE OCCUPANCYGROUP SECTION 310.3 OCCUPANCY R2 OCCUPANCY; (RESIDENTIAL, APARTMENT) M MERCANTILE (RETAIL) B BUSINESS (OFFICES) SEPARATED MIXED USE PER IBC 508; OCCUPANCY SEPARATIONS INDICATED ON FLOOR PLAN SECTION 510. SPECIAL PROVISIONS HORIZONTAL SEPARATIONS MUST COMPLY WITH THE FOLLOWING: 3-HR FIRE RESISTANCE RATING • THE BUILDING BELOW IS NOT GREATER THAN ONE STORY ABOVE GRADE • THE BUILDING BELOW IS OF TYPE 1A CONSTRUCTION • ANY SHAFT, STAIRWAYS, RAMP, OR ESCALATOR MUST BE IN A 2-HOUR RATED ENCLOSURE • THE BUILDING BELOW IS PROTECTED BY AN AUTOMATIC FIRE SPRINKLER SYSTEM, PER NFPA 13 SECTION 510.9 MULTIPLE BUILDINGS ABOVE A HORIZONTAL ASSEMBLY SHALL BE REGARDED AS SEPARATE BUILDINGS. BUILDING 2 EQUIPPED WITH NFPA 13R SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.2 TABLE 601 CONSTRUCTION TYPE: V-A SECTION 708 FIRE BLOCKING REQUIRED SECTION 718.3.2 DRAFTSTOPPING REQUIRED IN FLOORS, AT EVERY SLEEPING UNIT SECTION 718.4.2 DRAFTSTOPPING IN ATTICS: REQUIRED, EVERY 3,000 SFQ SECTION 903.2.8 GROUP R- AUTOMATIC SPRINKLER SYSTEM NFPA I3R REQUIRED. SECTION 1009 STAIRWAYS- EXCEPTIONS TAKEN, SEE DRAWING NOTES SECTION 1023 STAIRWAYS- ENCLOSURE MINIMUM OF 2HR RATING SECTION SMOKEPROOF ENCLOSURES- NOT REQ. WHERE TOP FLOOR IS 1023.11 LESS THAN 75 FT ABOVE FIRE DEPARTMENT ACCESS. (FLOOR LEVEL OF FOURTH FLOOR IS 37'-D" CONCEALED SPACES IBC 718 AND NFPA 13 A. FIREBLOCKING: REQUIRED, BOTH VERTICAL AND HORIZONTAL 10' INTERVALS BEHIND TRIM FINISHES. FIRE BLOCKING SHALL CONSIST OF ONE OF THE FOLLOWING: APPROVED NONCOMBUSTIBLE MAT 2" OR (2) 1" LUMBER W/BROKEN LAP JOINTS, 1 23/'32" WOOD STRUCTURAL PANEL W/JOINTS BACKED BY 23/32" STRUCTURAL PANEL OR 2X LUMBER. B. DRAFTSTOPPING IN FLOORS: PER IBC 718.3. C. DRAFTSTOPPING IN ATTIC: PER IBC 718.4.2. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES A. REFER TO SECTION 714 EXIT SIGNS & EMERGENCY LIGHTING EXIT SIGNS PROVIDED PER IBC 1013, INTERNAL BATTERY BACKUP. FLOOR -LEVEL EXITS SIGNS PROVIDED PER IBC 1013.2. MEANS OF EGRESS ILLUMINATION AND EMERGENCY LIGHTING PROVIDED PER IBC 1008. ELEVATOR REQUIRED TO MEET ASME A17.1 FOURTH FLOOR LIFE SAFETY PLAN SCALE : T32" - V-O" Subject to compliance with all regulations 3CALE: 3(32"=l'-O" of State and Local Codes City of Carmel STAIR B EXIT 8 0.3" 0'2pp U 160 48" 170 34" R LIFE SAFETY PLAN BUILDING HEIGHT AND AREA BUILDINGS 2 REQUIREMENT ALLOWABLE ACTUAL NO. OF STORIES -SECTION 504.2 4 STORIES W SPRINKLER 4 STORIES W SPRINKLER AREA -SECTION 506.2 21,000 SF PER FLOOR 19,465 SF PER FLOOR MAX SECTION 504.2 60' W SPRINKLER 48'-0" CORRIDOR WIDTH 44"MIN 60" MIN EGRESS DOOR SIZE 32" MIN 32" MIN PROVIDED MEANS OF EGRESS BUILDING 2 REQUIREMENT REQUIRED PROVIDED NUMBER OF EXITS 2 PER FLOOR 2 PER FLOOR STAIR WIDTH 440MIN 48"WIDTH PROVIDED CORRIDOR WIDTH 440MIN 60"MIN EGRESS DOOR SIZE 32" MIN 32" MIN PROVIDED TABULAR OCCUPANT LOAD, BUILDING 2 (IBC 1004.1.2) FLOOR OCC. TYPE AREA(SF) FACTOR (SF/PERSON) OCC.LOAD (PERSONS) FIRST BUSINESS 5,270 SF 1/100 GROSS 53 RESIDENTIAL 10.978 SF 1/200 GROSS 55 MERCANTILE 1,805 SF 1/60 GROSS 31 MECHANICAL 41SF 1/300 GROSS 1 SECOND RESIDENTIAL 18.978 SF 11200 GROSS 95 STORAGE 25SF MOO GROSS 1 MECHANICAL 41SF 1/300 GROSS 1 THIRD RESIDENTIAL 18,565 SF 1/200 GROSS 93 STORAGE 25 SF 1/300 GROSS 1 MECHANICAL 41SF 1/300 GROSS 1 FOURTH RESIDENTIAL 5,970 SF 1/200 GROSS 30 BUILDING TOTAL 362 FIRE RESISTIVE RATINGS TABLE 601 STRUCTURAL ELEMENT F.R. RATING F.R. RATING DESIGN NUMBER PER CODE PER DESIGN STRUCTURALFRAME FLOOR&BEAM 1HOUR 1HOUR U.L.#D902 COLUMNS 1HOUR 1HOUR U.L. #X752 & M29 BEARING WALLS (V-A) EXT. WALLS (R2) 1HOUR 1HOUR U.L. #U356 INT. WALLS 1HOUR 1HOUR U.L. #U305 CORRIDOR WALLS (112) 30 MIN 1HOUR U.L. #U311 OPENING PROTECTION 20 MIN 20 MIN GUESTROOM SEPARATION 1HOUR 1HOUR U.L.#U311 OPENING PROTECTION 45 MIN 60 MIN STAIR (INT. WALLS) 2 HOUR 2 HOUR U.L. #U301 STAIR (EXT. WALLS) 1HOUR 1HOUR U.L. #U356 OPENING PROTECTION 90 MIN 90 MIN ELEVATORS 2 HOUR 2 HOUR U.L. #U906 OPENING PROTECTION 90 MIN 90 MIN --- CEILING - - --- STORAGEM1ECH 1 HOUR 1 HOUR U.L. #U305 FLOOR -CEILING 1HOUR IHOUR U.L.#L521 ROOF - CEILING @ STAIR ROOF -CEILING 1HOUR 1HOUR U.L.#P522 SHAFT 1HOUR 1HOUR U.L. #U305 STAIR A 0.31113 16O 48" STAIR C 0.3" 2 160 48" NON -RATED, 2012 IBC SECTION 1009.3, EXCEPTION 1 STAIR C 0.3' 12 160 48" NON -RATED, 2012 IBC SECTION 1009.3, EXCEPTION 1 11 EGRESS ELEMENT ACTUAL OCCUPANTS PERSONS ACTUAL CLEAR WIDTH (PROVIDED) EGRESS CAPACITY (PERSONS) CAPACITY FACTOR —..---- 2HOUR RATED FIRE BARRIER 1 HOUR RATED �0�*iIIIIIIIi FIRE BARRIER EXIT EXIT SIGN - SEE ELECTRICAL SPACE AREA FUNCTION OF SPACE BUSINESS 6000 SF B OCCUPANCY 1 t 100 60 2 CLASSIFICATION NUMBER OF REQUIRED EXITS NUMBER OF OCCUPANTS REQUIRED S.F. PER OCCUPANT ♦_________ COMMON PATH OF TRAVEL TRAVEL DENOTES EXIT DISTANCE ROUTE 100'-6" L START DENOTES EXIT POINT DISCHARGE SEMI -RECESSED PORTABLE FIRE FEC EXTINGUISHER CABINET WITH PORTABLE FIRE EXTINGUISHER PER NFPA 72 AS SELECTED BY LOCAL FIRE MARSHALL. REFER TO DETAIL 10/A-602. FE WALL MOUNTED PORTABLE FIRE EXTINGUISHER PER NFPA 72 AS SELECTED BY LOCAL FIRE MARSHALL. WOULPERT AACHITEULME ENG I NEERINGjGEOSPATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 �7 IND [e] uj U J J 0 Cape N Eo `mv � U � C: `om c o c U N N w E v m � U Qlssuances: REv DESM"ON Mrs 0 Issued For Building 2 Review 1005/18 1 ASI#4 12/21/18 2 Issued For Building 2Permit 05/01/19 Prom. No.: 074904 Date: 10/05/18 A Sheet Name: THIRD AND FOURTH FLOOR LIFE SAFETY PLANS LS2=102 DATE: 10/31/19