1 16-0' I 3J'-0' 1 IT-81/2' 1 14'-61/Y 1 14'-11/2' 14'-11/2' 1 W-3' 1 W-3' 1 ca I
BLDG. 2 = LOW
SCALE: 3/16" = V-0"
vV V � BETWEEN TRU�SESAS REQUIRED. SUPPORTAND ���
ANCHORAGE OF CONDENSING UNITS ISTHE I U
RESPONSIBILITY OF THE MECHANICAL CONTRACTOR
(COORD. QUANTITY, SIZE & LOCATION OF CONDENSING UNITS
WITH MECH. B ARCH. DRAWINGS)
)F FRAMI
4TH FLOOR: LOW ROOF I FLOOR FRAMING PLAN NOTES:
1. BEARING ELEVATION OF ROOF TRUSSES - 882'-01/4'. TOP OF WOOD TRUSSES SHALL SLOPE PER ARCHITECTURAL PLANS AND SECTIONS
2. ROOF SHEATHING, REF SHEET S2-001, UNLESS OTHERWISE NOTED ON PLAN. ROOF SHEATHING IS APPLIED PERPENDICULAR TO
TRUSSES UNLESS OTHERWISE NOTED.
3. ALL LINES ON PLAN REPRESENT FLOOR FRAMING MEMBERS THAT ARE 18' DEEP PRE-ENGINEERED PARALLEL CHORD PLATED FLOOR
TRUSSES TO BE SPACED AT 24"ON CENTER (MAX.) UNLESS NOTED OTHERWISE. EXACT FLOOR TRUSS/JOIST LAYOUT AND DIMENSIONS ARE
THE RESPONSIBILITY OF THE TRUSS FABRICATOR AND FRAMING SUBCONTRACTOR. TRUSS/JOIST LAYOUT SHALL BE COORDINATED WITH
THE MECHANICAL, ELECTRICAL AND PLUMBING SUBCONTRACTORS PRIOR TO SUBMISSION OF TRUSS SHOP DRAWINGS, FABRICATION AND
INSTALLATION TO ENSURE TH E PROPOSED LAYOUT PROVIDES NECESSARY CLEARANCES FOR THE MECHANICAL, ELECTRICAL AND
PLUMBING TRADE ELEMENTS. FIXTURES. DUCTING AND PIPING.
EXACT FRAMING LAYOUT SHALL BE COORDINATED WITH ALL OTHER TRADE SUBCONTRACTORS PRIOR TO INSTALLATION OR ITEMS
INCLUDING BUT NOT LIMITED TO: ELECTRIC PANELS, ELECTRIC FIXTURES (INCLUDING CAN LIGHTS) , FIRE EXTINGUISHER CABINETS,
MEDICINE CABINETS, CONTROL JOINTS, DOOR FRAMING AND HVAC DUCTS/SOFFITS. IF THE LAYOUT IS CHANGED SUCH THAT THE LOADING
ON HEADERS/BEAMS IS INCREASED, THE FRAMING SUBCONTRACTOR SHALL SUBMIT A REVISED SCHEDULE OF THOSE H EADERS/BEAMS
STAMPED BY AN ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED.
4. ROOF TRUSS DESIGN LOADS AND CONSTRUCTION REQUIREMENTS ARE PROVIDED IN GENERAL NOTES ON SHEET S2-001 WITH
SNOWDRIFT AND WIND UPLIFT DIAGRAMS PROVIDED ON SHEET S2-115.
5. HEADERS SHOWN ON FLOOR PLAN ARE FOR OPENINGS BELOW THE FLOOR AND SUPPORT THE FLOOR FRAMING SHOWN ON PLAN.
6. SEE ARCHITECTURAL DRAWINGS FOR ALL OPENING LOCATIONS AND SIZES. TRUSS SUPPLIER SHALL PROVIDE SUPPLEMENTARY FRAMING,
H EAGER AND INCREASED CAPACITY REQUIREMENTS OF ADJACENT MEMBERS AS NECESSARY TO SUPPORT INTERRUPTED FRAMING.
T. TRUSS SUPPLIER SHALL PROVIDE ADDITIONAL FRAMING MEMBERS, SUPPLEMENTARY FRAMING, HEADERS OR MULTIPLE TRUSS OR
H IGH ER CAPACITY TRUSSES TO SUPPORT ROOF TOP MECHANICAL UNITS, SEE MECHANICAL DRAWINGS FOR SIZE, LOCATIONS, FOOTPRINTS
AND WEIGHTS.
B. "S-1, S-2, S-3 ETC." WALLS DESIGNATED ON PLANS ARE TO BE SHEAR WALLS: SEE APPROPRIATE SHEAR WALL ELEVATIONS ON S2-200
SERIES SHEETS AND ASSOCIATED SECTIONS AND DETAILS.
B. SEE THE WALL STUD SCHEDULE ON SHEET S2-501 FOR TYPICAL AND SPECIAL WALL FRAMING, DENOTED EW-1 AND CW-1.
9. IF WINDOW OPENINGS ARE SMALLER THAN THE WINDOW OPENINGS ON THE FLOOR BELOW, DIRECTLY BELOW THE OPENING, THEN
HEADER SIZE, LENGTH, AND LOCATION ARE TO MATCH FLOOR HEADERS BELOW.
10. ALL CS14 STRAPS SHALL BE BY SIMPSON STRONG -TIE OR APPROVED EQUIVALENT.
11. THE NUMBER MARKED IN PARENTHESIS (XX) NEXT TO STRAPS INDICATES THE MINIMUM NUMBER OF FASTENERS FOR THAT SEGMENT OF
THE SPAN. ALL FASTENERS SHALL BE SD SCREW #9xl 1/2" BY SIMPSON STRONG -TIE OR APPROVED EQUIVALENT. FASTENERS SHALL BE
EQUALY SPACED ALONG THE SPAN OF THE STRAP. PROVIDE 2x BLOCKING UNDERNEATH THE STRAP AND INSTALL THE STRAP DIRECTLY
BENEATH THE FLOOR SHEATHING.
iY]illa]q�P]Ii71L[N:67lElab.
HEADER LEGEND: SEE SHEET S2-501 FOR
HEADERSCHEDULE
HL3-9.5/2.3
# OF KING STUDS ADJACENT TO JACK STUDS
# OF JACK STUDS UNDER EACH END OF HEADER
HEADER SIZE - SEE HEADER SCHEDULE FOR ACTUAL SIZE
NOTE:
ALL JACK AND KING STUDS TO BE 2X6 SPRUCE
PINE FIR NO 1/NO 2
P1 INDICATES 6X6 DFL NO 1 AS JACK STUD
C
�E�
-F
WOOLG EUT
ARCNITEMMIENGINEw11NCjCECWATIAL
7635 Interactive Way
Suite 100
O Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
F
■a
W
Its]
■1
C1
a--+
E
Q
0
E
U
J•�
J
�A
K
U
rnc
CL
K
0
a
c
�
L
a
Q)
N
€ o
m
my
203
C00
U
m
dE
=U
Issuances:
oESM"M
Prom. No.: 074904
Date: 05/01/19
Sheet Name:
BLDG. 2 - LOW ROOF
FRAMING PLAN -AREA
A
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
',"19,
DATE: 10/31/19
BLDG. 2 NORTH
KEY PLAN
S2=104A