Loading...
HomeMy WebLinkAbout(09) A2-002t: L— U IY Q C 3 m V O rn v C w E E O a. a` a 1 BOTTOM OF DECK, — REFERTOSTRUCTURAL DRAWINGS STUDS AND INSULATION TO UNDERSIDE OF DECKING ABOVE (BID, BE, 6F, AND 6H ONLY) UNDERSIDE OF HORIZONTAL CEILING ASSEMBLY 2 Xfi WOOD STUDS @16"O.C. 5/8" GYPSUM BOARD OR MOISTURE RESISTANT GYPSUM BOARD AT PLUMBING PARTITIONS — 1/2" RESILIENT CHANNEL @ ALL CORRIDOR WALLS ADJACENT TO RESIDENTIAL UNITS CORRIDOR SIDE BASE PER SCHEDULE FIN. FLOOR � 2 3 4 5 6 7 BOTTOM OF CEILING DECK, REFER TO BOTTOM OF CEILING DRAWINGS BOTTOM OF DECK, BOTTOM OF DECK, DECK, REFER TO REFER TO REFER TO I STRUCTURAL STRUCTURAL / STRUCTURAL DRAWINGS MIN 3/8"THICK STRUCTURAL WOOD DRAWINGS CMU MASONRY STOPS UNDERSIDE OF DECK DRAWINGS DRAFT STOPPING (B (BB ONLY) . .. .. ,.- PANEL ..... UNDERSIDE OF HORIZONTAL CEILING ASSEMBLY STUDS AND INSULATION TO 2 X 4 WOOD STUDS @ 16" O.C. — UNDERSIDE OF CEILING ASSEMBLY (613 AND 6C ONLY) 5/8" GYPSUM BOARD OR — MOISTURE RESISTANT GYPSUM SOUND ATTENUATION BATT BOARD AT PLUMBING PARTITIONS INSULATION (BD, BE, 6F, AND 6H ONLY) 1/4" UNIT SIDE BASE PER E B DOUBLE LAVER OF 5/3 GYPSUM BOARD BOTH FIN. FLOOR SIDES (6F ONLY) PARTITION TYPE 6 6B - 1 LAVER 5/8" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD CHASE WALL. 6C— 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD STUD PARTITION, 1 LAVER 5/8" GYPSUM BOARD TO ASSEMBLY ABOVE. 6D — 1 LAVER 518' GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAVER 518' GYPSUM BOARD TO ASSEMBLY ABOVE. 1/2" RESILIENT CHANNEL @ ALL CORRIDOR WALLS ADJACENTTO RESIDENTIAL UNITS. INCLUDE ACOUSTICAL SEALANT AT TOP AND BOTTOM. MINIMUM STC = 50. 6E — 1 LAVER 518" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAYER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLYABOVE. 1/2" RESILIENT CHANNEL @ ALL CORRIDOR WALLS ADJACENT TO RESIDENTIAL UNITS. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305. 6F —2 LAVERS 518" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD STUD PARTITION WITH SOUND BATTS, 2 LAYERS 518" FIRE RATED GYPSUM BOARD TO ASSEMBLYABOVE. 1/2" RESILIENT CHANNEL @ ALL CORRIDOR WALLS ADJACENT TO RESIDENTIAL UNITS. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305. 6H — 1 LAVER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAYER OSB ON UNIT SIDE, 1 LAVER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE. 1/2" RESILIENT CHANNEL @ ALL CORRIDOR WALLS ADJACENT TO RESIDENTIAL UNITS. INCLUDE FIRE RATED SEALANTATTOPANDBOTTOM. MINIMUMSTC=50. ULDESIGN#U311 TYP. WALL PARTITION TYPES 3/4"APA RATED OSB SUBFLOORING 314" GVPCRETE "ACOUSTIBLOCK" SOUND -PROOFING MEMBRANE, 1/8" MINIMUM WOOD TRUSSES, CHANNELS SEE STRUCTURAL DRAWINGS 518" GYPSUM BOARD SOUND BATT INSULATION STAPLED TO UNDERSIDE OF SUBFLOORING A01 1HR FIRE RATED FLOOR / CEILING ASSEMBLY BETWEEN UNITS fill I saes FI nnPR 9 THPI I A ASSEMBLY TO HAVE MIN. STC RELEASED FOR CONSTRUCTION Subject to compliance with all regulations STUDS AND INSULATION TO UNDERSIDE OF CEILING ASSEMBLY STUDS AND INSULATION TO UNDERSIDE OF ASSEMBLYABOVE SOUND ATTENUATION BATT SOUND ATTENUATION BATT INSULATION (ONE SIDE OF INSULATION (4A, 4D, 4E, AND FRAMING ONLY) 4F ONLY) 4" 5/8" GVPSUN 2" BASE PER Si FIN. FLOOR 4A- 1 LAVER 518" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE INTERIOR 2X4 WOOD FURRING AND SOUND BATTS, '/z" AIR SPACE. 4B - 1 LAVER SO GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE, INTERIOR 2X4 WOOD CHASE WALL. 4C— 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X4 WOOD STUD PARTITION, 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE. 4D —1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X4 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE. INCLUDE ACOUSTICAL SEALANT AT TOP AND BOTTOM. MINIMUM STC = 50. 4E — 1 LAVER S/8" FIRE -RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X4 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAYER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLYABOVE. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305. 4F —2 LAVERS 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X4 WOOD STUD PARTITION WITH SOUND BATTS, 2 LAVERS 5'8" FIRE RATED GYPSUM BOARD TO ASSEMBLYABOVE. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305. L UNDERSIDE OF HORIZONTAL 1R" CEILING ASSEMBLY BOTTOM OF 5 1/2" 2x TOP PLATE FIRE BLOCKING HORIZONTAL CEILING ASSEMBLY 61/8" 2 Xfi WOOD STUDS @ 16" O.C. STAGGER STUDS AS REQUIRED SO STUDS DO NOT ALIGN BETWEEN WALLS SHEAR WALL SHEATHING TO BE PROVIDED IN OPEN SPACE AS REQUIRED, REFER TO STRUCTURAL DRAWINGS SOLID WOOD OR MINERAL WOOL FIRE BLOCKING PARTITION TYPE 9 9A- 1 LAYER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLYABOVE, INTERIOR 2X6 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAVER OSB PER STRUCTURAL DRAWINGS, AIR SPACE, INTERIOR 2X6 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAVER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. MINIMUM STC 50. ILL DESIGN #U311. 60 MIL. EPDM FULLY ADHERED ROOFING MEMBRANE OVER 5/8" PROTECTION BOARD OVER MIN. 1/2" THICK POLVISO RIGID INSULATION, MIN. 3/4"APA RATED OSB 3/4" GVPCRETE SUBFLOORING "ACOUSTIB MIN. 3/4" APA RATED ROOF LOCK" SHEATHING SOUND -PROOFING MEMBRANE, 1/8" MINIMUM I L 112"RESILIENT WOOD TRUSSES, WOODTRUSSES, CHANNELS SEE STRUCTURAL SEE STRUCTURAL DRAWINGS DRAWINGS 518" GYPSUM BOARD A02 1HR FIRE RATED FLOOR / CEILING ASSEMBLY BETWEEN A03 1HR FIRE RATED ROOFING ASSEMBLY ILL. P-522) CORRIDORS (ILL L-546) — 112"RESILIENT CHANNELS 5/8" GYPSUM BOARD 3/4" APA RATED OSB SUBFLOORING WOOD TRUSSES, SEE STRUCTURAL DRAWINGS 8" CMU WITH HORIZONTAL MASONRY REINF @ IT ox CORRIDOR SIDE BASE PER SCHEDULE FIN. FLOOR BOTTOM OF HORIZONTAL CEILING I ASSEMBLY — CMU MASONRY 5/8" GYPSUM BOARD OR PENETRATES MOISTURE RESISTANT HORIZONTAL ASSEMBLY GYPSUM BOARD AT (8A ONLY) PLUMBING CORRIDOR OR DWELLING SIDE 2x2 WOOD FURRING @ 16" o.c. SHAFT OPENING SIDE WITH SOUND BATT INSULATION PARTITION TYPE 8 BA — 8" NOMINAL CMU WALL. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. ILL DESIGN #U906. 8B - 8" NOMINAL CMU WALL TO UNDERSIDE OF ASSEMBLY ABOVE. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. ILL DESIGN#U906 E:1 10 1/4" SHAFT OPENING SIDE "MIN. AT 2A ONLY PARTITION TYPE EA 2 1/8" BASE PER SCHEDULE FIN. FLOOR PARTITION TYPE 2 2A-1 LAYER 5/8" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLYABOVE, INTERIOR 2X2 WOOD FURRING, 'Am AIR SPACE. 2B — 1 LAVER 5/8" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE, INTERIOR 2X2 WOOD CHASE WALL TIGHT TO CMU. 3-112" LIGHTWEIGHT CONCRETE FINISH FLOOR 34" GVPCRETE 3(4" GVPCRETE 3/4" GVPCRETE 2" METAL DECK LA RATED OSB B LA RATED OSB NDN NG SUBFLOORING N SOUND -PROOFING MEMBRANE, 1ME1/ ME,1 MINIMUM I A A8NG SUBFLOORING AN FLOOR ASSEMBLY AT FIRST FLOOR UNITS AND CORRIDOR. ASSEMBLY TO HAVE MIN. STC RATING OF 50 USE WOOD TRUSSES, x SEE STRCUTURAL DRAWINGS SOUND BATT INSULATION STAPLED TO UNDERSIDE OF SUBFLOORING 5/8" GYPSUM BOARD METALSUPPORT SUSPENDED FROM STRUCTURE ABOVE WITH WIRES WOOD TRUSSES, SEE STRUCTURAL T E 5/8" GYPSUM BOARD METALSUPPORT SUSPENDED FROM STRUCTURE ABOVE WITH WIRES A07 1HR FIRE RATED FLOOR / CEILING ASSEMBLY ABOVE RETAIL SLAB, NORTH END (ILL D-902) Ce1♦ F E D C u 1 HITEGTnnE �N41 NEERIN6j6EWPATIAL 7635 Interactive Way Suite 100 Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 E cam nO W n� W E U � J•� J �^1 W U af U) o O ON W C UM O C fi C 5 o C L N N NE U LLJ � U Q Issuances: REV DESCRI M Mrs 0 Issued For Building 2 Review 10/05/18 1 Issued For Building 2Permit 05/01/19 Prom. No.: 074904 Date: 10/05/18 A Sheet Name: ASSEMBLY TYPES of State and Local Codes \ City of+ Carmel CEILING ASSEMBLY TYPES `�111T�W \Ia,IV.911pAAL DATE: ` 10/31/19 ryalielp