HomeMy WebLinkAbout(09) A2-002t:
L—
U
IY
Q
C
3
m
V
O
rn
v
C
w
E
E
O
a. a`
a
1
BOTTOM OF DECK, —
REFERTOSTRUCTURAL
DRAWINGS
STUDS AND
INSULATION TO
UNDERSIDE OF
DECKING ABOVE (BID,
BE, 6F, AND 6H ONLY)
UNDERSIDE OF
HORIZONTAL CEILING
ASSEMBLY
2 Xfi WOOD STUDS @16"O.C.
5/8" GYPSUM BOARD OR
MOISTURE RESISTANT GYPSUM
BOARD AT PLUMBING PARTITIONS —
1/2" RESILIENT CHANNEL @
ALL CORRIDOR WALLS
ADJACENT TO RESIDENTIAL
UNITS
CORRIDOR SIDE
BASE PER SCHEDULE
FIN. FLOOR �
2 3 4 5 6 7
BOTTOM OF CEILING
DECK, REFER TO
BOTTOM OF
CEILING DRAWINGS
BOTTOM OF DECK,
BOTTOM OF DECK,
DECK, REFER TO
REFER TO
REFER TO
I
STRUCTURAL
STRUCTURAL /
STRUCTURAL
DRAWINGS
MIN 3/8"THICK
STRUCTURAL WOOD
DRAWINGS CMU MASONRY STOPS
UNDERSIDE OF DECK
DRAWINGS
DRAFT STOPPING
(B (BB ONLY)
. .. .. ,.-
PANEL
.....
UNDERSIDE OF
HORIZONTAL CEILING
ASSEMBLY
STUDS AND INSULATION TO
2 X 4 WOOD STUDS @ 16" O.C. —
UNDERSIDE OF CEILING
ASSEMBLY (613 AND 6C ONLY)
5/8" GYPSUM BOARD OR —
MOISTURE RESISTANT GYPSUM
SOUND ATTENUATION BATT
BOARD AT PLUMBING PARTITIONS
INSULATION (BD, BE, 6F, AND
6H ONLY)
1/4"
UNIT SIDE
BASE PER E
B DOUBLE LAVER OF 5/3
GYPSUM BOARD BOTH
FIN. FLOOR
SIDES (6F ONLY)
PARTITION TYPE 6
6B - 1 LAVER 5/8" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE,
INTERIOR 2X6 WOOD CHASE WALL.
6C— 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD
STUD PARTITION, 1 LAVER 5/8" GYPSUM BOARD TO ASSEMBLY ABOVE.
6D — 1 LAVER 518' GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6 WOOD
STUD PARTITION WITH SOUND BATTS, 1 LAVER 518' GYPSUM BOARD TO ASSEMBLY
ABOVE. 1/2" RESILIENT CHANNEL @ ALL CORRIDOR WALLS ADJACENTTO
RESIDENTIAL UNITS. INCLUDE ACOUSTICAL SEALANT AT TOP AND BOTTOM.
MINIMUM STC = 50.
6E — 1 LAVER 518" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6
WOOD STUD PARTITION WITH SOUND BATTS, 1 LAYER 5/8" FIRE RATED GYPSUM
BOARD TO ASSEMBLYABOVE. 1/2" RESILIENT CHANNEL @ ALL CORRIDOR WALLS
ADJACENT TO RESIDENTIAL UNITS. INCLUDE FIRE RATED SEALANT AT TOP AND
BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305.
6F —2 LAVERS 518" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR
2X6 WOOD STUD PARTITION WITH SOUND BATTS, 2 LAYERS 518" FIRE RATED
GYPSUM BOARD TO ASSEMBLYABOVE. 1/2" RESILIENT CHANNEL @ ALL CORRIDOR
WALLS ADJACENT TO RESIDENTIAL UNITS. INCLUDE FIRE RATED SEALANT AT TOP
AND BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305.
6H — 1 LAVER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X6
WOOD STUD PARTITION WITH SOUND BATTS, 1 LAYER OSB ON UNIT SIDE, 1 LAVER
5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE. 1/2" RESILIENT CHANNEL @
ALL CORRIDOR WALLS ADJACENT TO RESIDENTIAL UNITS. INCLUDE FIRE RATED
SEALANTATTOPANDBOTTOM. MINIMUMSTC=50. ULDESIGN#U311
TYP. WALL PARTITION TYPES
3/4"APA RATED OSB
SUBFLOORING
314" GVPCRETE
"ACOUSTIBLOCK"
SOUND -PROOFING
MEMBRANE, 1/8"
MINIMUM
WOOD TRUSSES, CHANNELS
SEE STRUCTURAL
DRAWINGS 518" GYPSUM BOARD
SOUND BATT INSULATION STAPLED
TO UNDERSIDE OF SUBFLOORING
A01 1HR FIRE RATED FLOOR / CEILING ASSEMBLY BETWEEN UNITS
fill I saes FI nnPR 9 THPI I A ASSEMBLY TO HAVE MIN. STC
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
STUDS AND INSULATION TO
UNDERSIDE OF CEILING
ASSEMBLY STUDS AND INSULATION
TO UNDERSIDE OF
ASSEMBLYABOVE
SOUND ATTENUATION BATT
SOUND ATTENUATION BATT INSULATION (ONE SIDE OF
INSULATION (4A, 4D, 4E, AND FRAMING ONLY)
4F ONLY)
4"
5/8" GVPSUN
2"
BASE PER Si
FIN. FLOOR
4A- 1 LAVER 518" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE
INTERIOR 2X4 WOOD FURRING AND SOUND BATTS, '/z" AIR SPACE.
4B - 1 LAVER SO GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE,
INTERIOR 2X4 WOOD CHASE WALL.
4C— 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X4 WOOD
STUD PARTITION, 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE.
4D —1 LAVER 518" GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR 2X4 WOOD
STUD PARTITION WITH SOUND BATTS, 1 LAVER 518" GYPSUM BOARD TO ASSEMBLY
ABOVE. INCLUDE ACOUSTICAL SEALANT AT TOP AND BOTTOM. MINIMUM STC = 50.
4E — 1 LAVER S/8" FIRE -RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR
2X4 WOOD STUD PARTITION WITH SOUND BATTS, 1 LAYER 5/8" FIRE RATED
GYPSUM BOARD TO ASSEMBLYABOVE. INCLUDE FIRE RATED SEALANT AT TOP
AND BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305.
4F —2 LAVERS 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY ABOVE, INTERIOR
2X4 WOOD STUD PARTITION WITH SOUND BATTS, 2 LAVERS 5'8" FIRE RATED
GYPSUM BOARD TO ASSEMBLYABOVE. INCLUDE FIRE RATED SEALANT AT TOP
AND BOTTOM. MINIMUM STC = 50. ILL DESIGN #U301 AND U305.
L UNDERSIDE OF HORIZONTAL
1R"
CEILING ASSEMBLY
BOTTOM OF
5 1/2"
2x TOP PLATE FIRE BLOCKING
HORIZONTAL CEILING
ASSEMBLY
61/8"
2 Xfi WOOD STUDS @ 16" O.C.
STAGGER STUDS AS REQUIRED
SO STUDS DO NOT ALIGN
BETWEEN WALLS
SHEAR WALL SHEATHING TO BE
PROVIDED IN OPEN SPACE AS
REQUIRED, REFER TO
STRUCTURAL DRAWINGS
SOLID WOOD OR MINERAL
WOOL FIRE BLOCKING
PARTITION TYPE 9
9A- 1 LAYER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLYABOVE, INTERIOR 2X6 WOOD STUD
PARTITION WITH SOUND BATTS, 1 LAVER OSB PER STRUCTURAL DRAWINGS, AIR SPACE, INTERIOR 2X6
WOOD STUD PARTITION WITH SOUND BATTS, 1 LAVER 5/8" FIRE RATED GYPSUM BOARD TO ASSEMBLY
ABOVE. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM. MINIMUM STC 50. ILL DESIGN #U311.
60 MIL. EPDM FULLY ADHERED
ROOFING MEMBRANE OVER 5/8"
PROTECTION BOARD OVER MIN.
1/2" THICK POLVISO RIGID
INSULATION,
MIN. 3/4"APA RATED OSB 3/4" GVPCRETE
SUBFLOORING "ACOUSTIB MIN. 3/4" APA RATED ROOF
LOCK" SHEATHING
SOUND -PROOFING
MEMBRANE, 1/8"
MINIMUM I
L 112"RESILIENT
WOOD TRUSSES,
WOODTRUSSES,
CHANNELS
SEE STRUCTURAL
SEE STRUCTURAL
DRAWINGS
DRAWINGS
518" GYPSUM BOARD
A02 1HR FIRE RATED FLOOR / CEILING ASSEMBLY BETWEEN A03 1HR FIRE RATED ROOFING ASSEMBLY ILL. P-522)
CORRIDORS (ILL L-546)
— 112"RESILIENT
CHANNELS
5/8" GYPSUM BOARD
3/4" APA RATED OSB
SUBFLOORING
WOOD TRUSSES,
SEE STRUCTURAL
DRAWINGS
8" CMU WITH HORIZONTAL
MASONRY REINF @ IT ox
CORRIDOR SIDE
BASE PER SCHEDULE
FIN. FLOOR
BOTTOM OF
HORIZONTAL CEILING I
ASSEMBLY
— CMU MASONRY
5/8" GYPSUM BOARD OR
PENETRATES
MOISTURE RESISTANT
HORIZONTAL ASSEMBLY
GYPSUM BOARD AT
(8A ONLY)
PLUMBING
CORRIDOR OR
DWELLING SIDE
2x2 WOOD
FURRING @ 16" o.c.
SHAFT OPENING SIDE
WITH SOUND BATT
INSULATION
PARTITION TYPE 8
BA — 8" NOMINAL CMU WALL. INCLUDE FIRE RATED SEALANT AT TOP AND BOTTOM.
ILL DESIGN #U906.
8B - 8" NOMINAL CMU WALL TO UNDERSIDE OF ASSEMBLY ABOVE. INCLUDE FIRE
RATED SEALANT AT TOP AND BOTTOM. ILL DESIGN#U906
E:1
10 1/4"
SHAFT OPENING SIDE
"MIN. AT 2A ONLY
PARTITION TYPE EA
2 1/8"
BASE PER
SCHEDULE
FIN. FLOOR
PARTITION TYPE 2
2A-1 LAYER 5/8" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLYABOVE,
INTERIOR 2X2 WOOD FURRING, 'Am AIR SPACE.
2B — 1 LAVER 5/8" GYPSUM BOARD ON FINISHED SIDE TO ASSEMBLY ABOVE,
INTERIOR 2X2 WOOD CHASE WALL TIGHT TO CMU.
3-112" LIGHTWEIGHT
CONCRETE
FINISH FLOOR
34" GVPCRETE 3(4" GVPCRETE 3/4" GVPCRETE 2" METAL DECK
LA RATED OSB B LA RATED OSB NDN NG SUBFLOORING N SOUND -PROOFING
MEMBRANE, 1ME1/ ME,1
MINIMUM I A A8NG SUBFLOORING
AN FLOOR ASSEMBLY AT FIRST FLOOR UNITS AND CORRIDOR.
ASSEMBLY TO HAVE MIN. STC RATING OF 50
USE
WOOD TRUSSES, x
SEE STRCUTURAL
DRAWINGS
SOUND BATT INSULATION
STAPLED TO UNDERSIDE
OF SUBFLOORING
5/8" GYPSUM BOARD
METALSUPPORT
SUSPENDED
FROM STRUCTURE ABOVE
WITH WIRES
WOOD TRUSSES,
SEE STRUCTURAL
T
E
5/8" GYPSUM BOARD
METALSUPPORT
SUSPENDED
FROM STRUCTURE ABOVE
WITH WIRES
A07 1HR FIRE RATED FLOOR / CEILING ASSEMBLY ABOVE RETAIL SLAB,
NORTH END (ILL D-902)
Ce1♦
F
E
D
C
u
1 HITEGTnnE �N41 NEERIN6j6EWPATIAL
7635 Interactive Way
Suite 100
Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
E
cam
nO
W
n�
W
E
U
�
J•�
J
�^1
W
U
af
U)
o
O
ON
W
C
UM
O C
fi
C 5
o C
L
N N
NE
U
LLJ
� U
Q Issuances:
REV
DESCRI M
Mrs
0
Issued For Building 2 Review
10/05/18
1
Issued For Building 2Permit
05/01/19
Prom. No.: 074904
Date: 10/05/18
A Sheet Name:
ASSEMBLY TYPES
of State and Local Codes
\ City of+ Carmel CEILING ASSEMBLY TYPES
`�111T�W \Ia,IV.911pAAL
DATE: ` 10/31/19
ryalielp