HomeMy WebLinkAbout(09) A2-3121 1 2 1 3 1 4 I 5 I 6 I 7 I 8 1 s
fi
INSULATION RUN OVERTOP THE PIPING IN THE
ROOF TRUSSES ABOVE CEILING
NAILABLE BLOCKING AT
TOP OF PARAPET
EXTERIOR GYPSUM BOARD
SHEATHING OR OSB
SHEATHING
ATTIC VENTILATION
LOUVER - REFER TO ROOF
�.
PLAN FOR REQUIREMENTS
CONTINUE ROOFING UP
AND OVER PARAPET
60 MIL EPDM FULLY
ADHERED ROOFING
MEMBRANE
<
n
.
m
61101WA
OSB ROOF SHEATHING, -
REFER TO STRUCTURAL
DRAWINGS
BATT INSULATION, R-38-
MINIMUM
WOOD ROOF TRUSSES, -
REFER TO STRUCTURAL
DRAWINGS
1W METAL RESILIENT
CHANNEL
5/8°-TYPE X GYPSUM
BOARD
PRE -FINISHED METAL
COPING CAP
DOUBLE BRICK SOLDIER
COURSE
DOUBLE 2X6 TOP PLATE
GALVANIZED METAL BRICK
TIES AT 16" ON CENTER,
VERTICALLY AND
HORIZONTALLY
BRICK VENEER, REFER TO
ELEVATIONS FOR COLOR
ILL DESIGN #P522
OSB WALL SHEATHING,
REFER TO STRUCTURAL
DRAWINGS
DOUBLE 2X6 TOP PLATE
ARCHED DOUBLE BRICK
KING COURSE
DB
505
a
m
2" DRAINABLE EIFS SYSTEM
PER MANUF'R, REFERTO
ELEV.FORTYPE
VINYL WINDOW, AS
SCHEDULED
NAILABLE BLOCKING
TOP OF PARAPET
CONTINUE ROOFING
AND OVER PARAPET
EXTERIOR GYPSUM I
SHEATHING OR OSB
SHEATHING
60 MIL EPDM FULLY -
ADHERED ROOFING
MEMBRANE
OSB ROOF SHEATHING, -
REFER TO STRUCTURAL
DRAWINGS
BATT INSULATION, R-38-
MINIMUM
WOOD ROOF TRUSSES, -
REFER TO STRUCTURAL
DRAWINGS
Y°WETAL RESILIENT
CHANNEL
5/8°-TYPE X GYPSUM
BOARD
SLOPE
PRE -FINISHED METAL
COPING CAP
DOUBLE BRICK SOLDIER
COURSE
EXTERIOR GYPSUM BOARD
SHEATHING OR OSB
SHEATHING
BATT INSULATION, R-19
MINIMUM
ILL DESIGN # P522
NAILABLE BLOCKING
BRICK VENEER, REFER TO
TOP OF PARAPET
ELEVATIONS FOR COLOR
CONTINUE ROOFING
WEATHER BARRIER
AND OVER PARAPET
DOUBLE 2X6 TOP PLATE
EXTERIOR GYPSUM I
BRICK SOLDIER COURSE
SHEATHING OR OSB
SHEATHING
THROUGH WALL FLASHING
60 MIL EPDM FULLY -
ADHERED ROOFING
STEEL ANGLE LINTEL.
MEMBRANE
REFER TO STRUCTURAL
DRAWINGS
VINYL WINDOW, AS
SCHEDULED
A III— BATT INSULATION, R-19
MINIMUM T OSB ROOF SHEATHING,
2.60 SILL FLASHING REFER TO STRUCTURAL
5/80-TYPE X GYPSUM DRAWINGS
BOARD 20 DRAINABLE EIFS SYSTEM
PER MANUF'R, REFER TO
'/.°-GYPCRETE ''/.°-GYPCRETE ELEV. FOR TYPE WOOD ROOF TRUSSES,
2° DRAINABLE EIFS SYSTEM 'ACOUSTIBLOCK° OSB WALL SHEATHING, REFER STRUCTURAL
°ACOUSTIBLOCK° �0 PER MANUF'R, REFER TO SOUND -PROOFING REFERTO STRUCTURAL DRAWINGS
SOUND -PROOFING \ ELEV. FOR TYPE MEMBRANE, 1/8" MINIMUM _ DRAWINGS _ l7 /lw
MEMBRANE, SOUND-PROOFING
MINIMUM \ 883' - o r 4�
4" �1
3/V APA RATED OSB
SUBFLOORING WEATHER BARRIER '/.`APA RATED OSB ILL DESIGN #L546 CHANNEL RESILIENT
`\ _ _FIOOf 04 SUBFLOORING WEATHER BARRIER
883' - 7 3/4" BATT INSULATION, R-1 DOUBLE 2X6 TOP PLATE 538"-TYPE X GYPSUM
MINIMUM BOARD
ILL DESIGN #L546
BATT INSULATION, R-1 OSB WALL SHEATHING,
MINIMUM REFER TO DRAWINGS CHANNEL
y^-METAL RESILIENT g
CHANNEL 29
DOUBLE 2X6 TOP PLATE I I.60
VINYL WINDOW, AS
5/8°-TYPE X GYPSUM Il SCHEDULED
1/2'-METAL RESILIENT BOARD, `- 5/8"-TYPE X GYPSUM
CHANNEL VINYL WINDOW, AS BOARD
SCHEDULED
5/8"-TYPE X GYPSUM t
'/.°-GYPCRETE
BOARD 2 80
°ACOUSTIBLOCK"
5/8"TYPE XGYPSUM SILL FLASHING SOUND -PROOFING
BOARD MEMBRANE, 1/8' MINIMUM
5/8°-TYPE X GYPSUM '/.
T "-GYPCRETE BATT INSULATION, R-19
BOARD 2.60 'ACOUSTIBLOCK' MINIMUM
SOUND -PROOFING 'W APA RATED OSB
%'-GYPCRETE MEMBRANE, 1/8" MINIMUM SUBFLOORING
WEATHER BARRIER BATT INSULATION, R-19
'ACOUSTIBLOCK° 2' DRAINABLE EIFS SYSTEM 3/4•-qpq RATED OSE MINIMUM
SOUND -PROOFING PER MANUF'R, REFER TO Floor 03
MEMBRANE, 1/8" MINIMUM ELEV. FOR TYPE SUBFLOORING_ _ _ _ _ _ _
872' - 11 7/8
3/.°-APA RATED OSB WEATHER BARRIER OSB WALL SHEATHING, ILL DESIGN # L546
SUBFLOORING REFER TO STRUCTURAL 'W-METAL RESILIENT
Floor 03 DRAWINGS CHANNEL
872' - 111 7/1 BATT INSULATION, R-19 ILL DESIGN #L546
MINIMUM 90-TYPE X GYPSUM
OSB WALL SHEATHING,
REFER STRUCTURAL BOARD
BATT INSULATION, R-19 DRAWINGS VINYL WINDOW, AS
MINIMUM DOUBLE 2X6 TOP PLATE SCHEDULED
ILL DESIGN #L546 2" DRAINABLE EIFS SYSTEM
DOUBLE 2X6 TOP PLATE 1/25iv1ETAL RESILIENT PER MANUF'R, REFER TO
CHANNEL I' �J
5/8°-TYPE X GYPSUM J BOARD VINYL WINDOW, AS
SCHEDULED
BRICK ROWLOCK
5/8"-TYPE XGYPSUM 1
BOARD 2-80 BRICK VENEER, REFER TO
ELEVATIONS FOR COLOR
ILL DESIGN #D902 -
BRICK SOLDIER COURSE
Floor 02
862'
GALVANIZED METAL BRICK
TIES AT 16' ON CENTER,
BATT INSULATION, R-19 VERTICALLY AND
MINIMUM HORIZONTALLY
BRICK SOLDIER COURSE
WEATHER BARRIER
OSB WALL SHEATHING,
B2 REFER TO STRUCTURAL
2-505 I DRAWINGS
BRICK SOLDIER COURSE
BOARD
STOREFRONT SYSTEM W/ I THROUGH WALL FLASHING
INSULATED GLASS, REFER
TO SHEET A2-603 FOR
DETAILS — 1 STEEL FRAMING, REFER TO
JSTRUCTURAL DRAWINGS
I.. Floor 01
849' -101,
SEALANTAT DISIMILAR
4° POURED CONCRETE MATERIALS
SLAB, REFER TO
STRUCTURAL DRAWINGS IW EXPANSION JOINT
4° RIGID INSULATION
F.F_Podium
847, - 4"
N =.STIR Podium
846' - 8"
EXISTING STRUCTURAL -
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and local Codes SECTION
City of Carmel I/4" = 1'-0"
DATE: 10/31/19
CHANNEL ELEV. FOR TYPE
VINYL WINDOW, AS 518°-TYPE X GYPSUM
BOARD TYPE XGYPSUM 2-60 - ^ SCHEDULED BOARD
BOA
3/.°-GYPCRETE
'ACOUSTIBLOCW
SOUND -PROOFING
MEMBRANE, 1/8" MINIMUM
'/."-APA RATED OSB
_ SUBFLOORING
BATT INSULATION, R-1 2-602 BRICK ROW LOCK
MINIMUM
5/8°-TYPE X GYPSUM BATT INSULATION, R-19
BOARD MINIMUM
— — — WEATHER BARRIER Floor02 L
ILL DESIGN #0902 4 862' - 4"
'W-METAL RESILIENT
CHANNEL
BATT INSULATION, R-1 GALVANIZED METAL BRICK 5/8°-TYPE X GYPSUM
TIES AT 16" ON CENTER,
MINIMUM VERTICALLVAND BOARD
HORIZONTALLY
BRICK VENEER, REFER TO
ELEVATIONS FOR COLOR
OSB WALL SHEATHING,
REFERTO STRUCTURAL
DRAWINGS
TYPE X GYPSUM
BRICK SOLDIER COURSE
BOARD 24 THROUGH WALL FLASHING
2.601
STEEL FRAMING, REFER TO
STRUCTURAL DRAWINGS
STOREFRONT SYSTEM W/
INSULATED GLASS, REFER
�.., TO SHEET A2-603 FOR 5y8'-TYPE X GYPSUM
DETAILS BOARD
- %/ GYPCRETE
'/."-APA RATED OSB
SUBFLOORING
Floor 01 T
849' - 100"
1" RIGID INSULATION
THERMALBREAK
5/8°-TYPE X GYPSUM------,.
4^POURED CONCRETE EXTERIOR CONCRETE, BOARD
SLAB, REFER TO
STRUCTURAL DRAWINGS REFER TO CIVIL DRAWINGS 2X6 PRESSURE TREATED
WOOD SILL PLATE AND SILL
SEALER
EXISTING STRUCTURAL 2°-CONTINUOUS RIGID
4°-RIGID INSULATION SLAB INSULATION
F.F. Podium
PRE -FINISHED METAL
COPING CAP
EXTERIOR GYPSUM BOARD
SHEATHING OR OSB
SHEATHING
0
SLOPE n 2° DRAINABLE EIFS SYSTEM
PER MANUF'R, REFER TO
ELEV. FOR TYPE
BATT INSULATION, R-38
MINIMUM
WEATHER BARRIER
ILL DESIGN # P522
DOUBLE 2X6 TOP PLATE
8' H. EIFS LINTEL, REFER TO
ELEVATIONS FOR COLOR
VINYL WINDOW, AS
SCHEDULED
V 4" H. EIFS SILL, REFER TO
ELEVATIONS FOR COLOR
25 DRAINABLE EIFS SYSTEM
PER MANUF'R, REFER TO
ELEV. FOR TYPE
OSB WALL SHEATHING,
REFER TO STRUCTURAL
DRAWINGS
BRICK ROWLOCK
• _ _ Floor 03 n
872' - 11 7/8" V
BRICK VENEER, REFER TO
ELEVATIONS FOR COLOR
GALVANIZED METAL BRICK
TIES AT 16" ON CENTER,
VERTICALLY AND
HORIZONTALLY
DOUBLE 2X6 TOP PLATE
BRICK SOLDIER COURSE
X X X THROUGH WALL FLASHING
J STEEL ANGLE LINTEL,
REFER TO STRUCTURAL
DRAWINGS
7
2-602
J
� W EATHER BARRIER
Floor 02
862' -
—OSB WALL SHEATHING,
REFER TO STRUCTURAL
DRAWINGS
ILL DESIGN # L546
—DOUBLE 2X6 TOP PLATE
25 DRAINABLE EIFS SYSTEM
PER MANUF'R, REFER TO
-� ELEV. FOR TYPE
BRICK ROWLOCK
BRICK VENEER, REFER TO
ELEVATIONS FOR COLOR
GALVANIZED METAL BRICK
TIES AT 16° ON CENTER,
VERTICALLYAND
HORIZONTALLY
BRICK SOLDIER COURSE
Floor 01 n
849' - 100"
W EATHER BARRIER
THROUGH WALL FLASHING
—MASONRY WEEP VENTS
847 - 4" —
— —
84T - 4'Q
...2, .:,
..,
.. ..°
' STR Podium
•'STIR Podium
846=
846'-8�
-;,
o'°
EXTERIOR CONCRETE,
e-
EXISTING STRUCTURAL
°REFER TO CIVIL DRAWINGS
SLAB
A3 WALL SECTION
As
WALL SECTION
A2.101 SCALE: 3/4" = 1'-01,
A2.101
SCALE: 3/4" = 1'-0"
PRE -FINISHED METAL
COPING CAP
NAILABLE BLOCKING
TOP OF PARAPET
CONTINUE ROOFING L
AND OVER PARAPET
EXTERIOR GYPSUM BI
SHEATHING OR OSB
SHEATHING
60 MIL EPDM FULLY
ADHERED ROOFING
MEMBRANE
OSB ROOF SHEATHING, -
REFER TO STRUCTURAL
DRAWINGS
BATT INSULATION, R-38-
MINIMUM
WOOD ROOF TRUSSES, -
REFER TO STRUCTURAL
DRAWINGS
1/,"-METAL RESILIENT
CHANNEL
5/8'-TYPE X GYPSUM —
BOARD
SOUND -PROOFING
MEMBRANE. I& MINIMUM
33W APA RATED OSB
SUBFLOORING
BATT INSULATION, R-19
MINIMUM
'W-METAL RESILII
CHANNEL
5/8°-TYPE X GYPS
BOARD
DOUBLE 2X6 TOP
SOUND -PROOFING
MEMBRANE, 1/8° MINIMUM
3W APA RATED OSB
SUBFLOORING
BATT INSULATION,
MINIMUM
1/V-METAL RESILIEf
CHANNEL
5/8°-TYPE X GVPSU
BOARD
Iw4XIN(619:
MEMBRANE, 1/8° MINIMUM
33W APA RATED OSB
SUBFLOORING
5/8°-TYPE X GYPSUM
BOARD
4"POURED CONCRETE
SLAB, REFER TO
STRUCTURAL DRAWINGS
4° RIGID INSULATION
WALL SECTION
SCALE: 3/4" = V-0"
PRE -MANUFACTURED EIFS
CORNICE, TYPE 4- REFER
TO DRAWING A2-504
REFER TO STRUCTURAL
DRAWINGS
OP� W EATHER BARRIER
J
GALVANIZED METAL BRICK
TIES AT 16' ON CENTER,
VERTICALLY AND
HORIZONTALLY
BRICK VENEER, REFER TO
ELEVATIONS FOR COLOR
ILL DESIGN # P522
DOUBLE 2X6 TOP PLATE
THROUGH WALL FLASHING
MASONRY UNIT LINTEL
STEEL ANGLE LINTEL,
REFER TO STRUCTURAL
SIM 13 DRAWINGS
2-601
PREFINISHED RAILING
SYSTEM, REFER TO SHEET
A2-521 FOR DETAILS
SLIDING VINYL PATIO DOOR
B4 `
2-505 UNIT. SEE SCHEDULE
---- SILL FLASHING
BRICK ROWLOCK
Floor 03
872' - 11 7/8" V
ILL DESIGN #L546
BRICK VENEER, REFER TO
_
ELEVATIONS FOR COLOR
/
y
MASONRY UNIT LINTEL
THROUGH WALL FLASHING
- STEEL ANGLE LINTEL,
REFER TO STRUCTURAL
DRAWINGS
SLIDING VINYL PATIO DOOR
UNIT. SEE SCHEDULE
BRICK ROWLOCK
2-sos Floor 02
862' - 4" V
ILL DESIGN # L546
PREFINISHED RAILING
SYSTEM, REFER SHEET
A2-521 FOR DETAILS
OSB WALL SHEATHING,
REFER TO STRUCTURAL
DRAWINGS
MASONRY VENEER UNIT
MASONRY UNIT LINTEL
THROUGH WALL FLASHING
STEEL ANGLE LINTEL,
REFER TO STRUCTURAL
DRAWINGS
3 J
801
SLIDING VINYL PATIO DOOR
UNIT. SEE SCHEDULE
BRICK ROWLOCK
PREFINISHED RAILING
- A2 SYSTEM, REFER TO SHEET
2-505 A2-521 FOR DETAILS
Floor 01
849' - 10"
_ WEATHER BARRIER
THROUGH WALL FLASHING
GROUT SOLID
MASONRY VENEER UNIT
EXTERIOR CONCRETE,
REFER TO CIVIL DRAWINGS
F.F._Podium
"SEALANTAT DISIMILAR - 847 -4
o- MATERIALS,'STR pOdlUm
846' - 8"
1° RIGID INSULATION
THERMALBREAK
IAi
WOULPERT
1RERITEMUM I_Ne I NEERINSISEOSPITILL
7635 Interactive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
F
E
W
D
^O
III
U �
C J
J
of
0 c
D'
oOc
�l Nr
IN
W O c
F N N
U "E
B
Q Issuances:
REV
DESCRI"M
MTE
0
Issued For Building 2 Review
10/05/18
1
ASI#4
12/21/18
2
Issued For Building 2Pemil
05301/19
Prom. No.: 074904
Date: 10/05/18
A Sheet Name:
WALL SECTIONS
A2=312