HomeMy WebLinkAbout(09) A2-4012 3 9 5 7 y 9 R 2 a. UNIT B2•A2 • ONE BEDROOM SCALE: 1/4" = 9'-0" CEILING -5/8" GYP BD ON 2x4'S (LLV) AT 24" OC TIGHT TO UNDERSIDE OF RATED CEILING ASSMEBLY UNIT 62•A5 • ONE BEDROOM A9dn9 CCCI P 1/d" = 1'11" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camlel UNIT 62•A4 • ONE BEDROOM SGALL: 1/4" = 1'-0 ON 2x4'S (LLV) AT 24" OC TIGHT TO UNDERSIDE OF RATED CEILING ASSMEBLY UNIT B2•A1 In ONE BEDROOM SCALE: 1/4" = T-0" It GENERAL NOTES - INTERIOR FRAMING 1. ALL MATERIALS AND WORK SHALL BE FURNISHED AND INSTALLED IN WORKMANSHIP -LIKE MANNER IN STRICT ACCORDANCE WITH ALL PREVAILING LOCAL, STATE, AND NATIONAL BUILDING CODES. 2. CONTRACTORS SHALL STORE, HANDLE, AND INSTALL ALL PRODUCTS AND ASSEMBLIES PER THE MANUFACTURER'S INSTRUCTIONS, RECOMMENDATIONS, AND PROCEDURES IN ORDER TO ENSURE THE MANUFACTURER'S WARRANTY IS VALIDATED. 3. SUB -CONTRACTORS SHALL VERIFYALL DIMENSIONS. 4. ALL DIMENSIONS ARE GIVEN FROM STUD TO STUD, UNLESS OTHERWISE NOTED. 5. STUD DIMENSIONS ARE 3 1/2" OR 5 1/2" UNO. 6. ALL EXTERIOR WALLS ARE TO BE 2x6 STUDS. REFER TO STRUCTURAL FOR OTHER LOCATIONS. 7. UNIT LAYOUT IS AS SHOWN ON 1/4"SCALE PLANS. FOR BUILDING DIMENSIONS, REFER TO 1/8" SCALE OVERALL BUILDING FLOOR PLANS. S. GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL CONTRACTOR S FOR ALL RESPECTIVE OPENINGS, AS REQUIRED, INCLUDING MAINTAINING FIRE RATED ASSEMBLIES. 9. FOR MATERIALS AND FINISHES, REFER TO FINISH SCHEDULES ON THIS SHEET. 10. TYPE'X" 518" THICK GYPSUM BOARD SHALL BE USED AT RATED WALL CONSTRUCTION INCLUDING BEARING WALLS. TYPE "C" 5/8" GYPSUM BOARD SHALL BE USED AT CEILINGS. REFER TO UL ASSEMBLIES. 11. ALL CEILING ASSEMBLIES ARE TO BE MIN. 1 HOUR FIRE RATED CONSTRUCTION WITH DAMPERS AT ALL DUCT PENETRATIONS. REFER TO MECHANICAL DRAWINGS. 12. ALL WALLS WHICH FORM PERIMETERS OF DWELLING UNITS AND ALL LOAD BEARING WALLS SHALL BE MIN. 1 HOUR FIRE RATED UL-U305 OR UL-U314 ASSEMBLY. NON -LOAD BEARING INTERIOR PARTITIONS WITHIN DWELLING UNITS DO NOT REQUIRE FIRE RATING. 13. USE MIN.3/8" OISE AT ALL ATTIC DRAFT STOPS. 14. REFER TO STRUCTURAL FOR ALL WINDOW AND DOOR HEADER SIZES. 15. CONTRACTOR TO PROVIDE: (1) 12" WOOD SHELF AND ROD IN ALL ENTRY CLOSETS, (1) 12" WOOD SHELF, ROD, AND VERTICAL SHELVING IN BEDROOM CLOSETS, (1) 12" WOOD SHELF AT LAUNDRY, (5) 12" DEEP WOOD SHELVES IN LINEN CLOSETS, AND (5) 18' DEEP WOOD SHELVES IN PANTRY. PROVIDE SHELVES IN BATH ROOM AS SHOWN. REFER TO DRAWINGS. 16. REFER TO STRUCTURAL DRAWINGS FOR INTERIOR BEARING WALL MEMBER SEE AND SPACING. 17. FLOOR TOPPING TO BE 3/4" GYPCRETE 2000 OR APPROVED EQUAL. CONTRACTOR TO ADJUST STAIR RISER HEIGHTS AND DOOR HEADER HEIGHTS ABOVE SUB -FLOOR ACCORDINGLY. 18. CONTRACTOR TO PROVIDE PAPER FACED INSULATION FORALL EXTERIOR WALLS. PROVIDE TY'VEK VAPOR BARRIER ON ALL EXTERIOR WALLS. 19. ALL WALL AND CEILING GYPSUM BOARD TO BE SMOOTH FINISH COATING. REFER TO FINISH SCHEDULE FOR SHEEN. 20. PROVIDE WASHER AND DRYER HOOKUPS IN ALL UNITS AS REQUIRED TO MEET OR EXCEED APPLICABLE CODES. 21. DWELLING UNIT SEPARATION WALLS OF APARTMENT UNITS SHALL BE MIN, ONE HOUR FIRE RATED CONSTRUCTION. 22. PROVIDE WOOD BLOCKING SUPPORTAS REQUIRED. INCLUDING, BUT NOT LIMITED TO: ALL LOCATIONS FOR GRAB BARS IN ALL UNITS AND AT ALL STAIR RAILS, SUPPORT FOR SHEATHING EDGES NOT ON FRAMING, KITCHEN WALL CABINETS ON ALL FLOORS, AND AT TV WALL LOCATIONS. 23. PROVIDE R-13 (3 ls') MIN. ACOUSTIC BATT INSULATION IN ALL DWELLING UNIT SEPARATION WALLS. IN CEILINGS PROVIDE R-13 (3 %") MIN. ACOUSTIC BATT INSULATION AT LOCATIONS WHERE OCCUPIED SPACE ABOVE HAS A HARD FLOOR SURFACE. PROVIDE R-19 (51/2") MIN. PAPER FACED THERMAL BATT INSULATION IN EXTERIOR WALLS. PROVIDE R-30 (9') MIN. IN CEILING ABOVE GARAGES. PROVIDE R-38 (11') MIN. IN CEILING BELOW ROOF AREAS. 24. ALL LIVING UNITS SHALL BE CONSTRUCTED TO COMPLY WITH OBC ADAPTABLE UNIT TYPE "B" REQUIREMENTS, UNLESS DESIGNATED ADA ACCESSIBLE UNIT TYPE "A" IN UNITS LOCATIONS SHOWN. 25. PROVIDE CONTROL JOINTS IN CORRIDOR GYPSUM BOARD CEILING 30 FEET O.C. WITH RESILIENT CHANNELS, TYPICAL. 26. STRUCTURAL MEMBERS SUPPORTING MORE THAN ONE FLOOR SHALL BE INDIVIDUALLY PROTECTED BYAONE-HOUR FIRE RESISTANCE RATED ASSEMBLY. L'r—Zmm■■■� ■- ell ■■■■■■■ i�'— p 11 L_M■IW■rrl ��■■� .■■■■IF ■II11�� i m to, �i.\ jl��I■......._■I r� �■■■■■I \\`R�i■rII■■■■■■.m A ■■■■■■■■■■■■■r■■fl■■■■r■■� � �1■11�� �., ■■I■■ ■I■■■■■■■■■■■■■■■■■■m7■■■■■■1 �m ■��■ ■il■■■■■■■■■■■■■■■■■■■■■■■■■■1� - ME . : a . -■■ d■■■■ q■■■■ ■■■■■■■■.I■ ■■1■■■� II=■Il1lRlYIkip gym■■■■■■■■■■■■■■■■■■■■■■■rm LLY■■■■■■■■■■■■■■■■■■■■■ N ■ • a a . -i . N e& 0 ■■■■■■■■ ml ■■■■■■s■■�■■■ I■■■■■■. 5 UNIT B2•A3 • ONE BEDROOM A2-102 SCALE: 1/4"=1'-0" %A# W®®LPERT ARCH REaVes IUN61 NEERINOj0E04PATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 ILE L1 Irr Qlssuanees: Rev Dns MM a,E 0 Issued For Building 2 Review 10/05/18 1 ASI#4 12/21/18 2 Issued For Building 2Permit 05/01/19 Prom. No.: 074904 Date: 10/05/18 A Sheet Name: UNIT PLANS FYZA L1111 DATE: 10/31/19