RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel
DATE: 10/31/19
UNIT B2•A2 TYPE A AN ONE B
.grAI F- 1/A" = 1'-n"
RATED CEILING ASSMEBLY
UNIT B2•B1 AN TWO
UNIT B2•B2 AN TWO BEDROOM
SCALE: 1/4" = 1'-0"
GENERAL NOTES - INTERIOR FRAMING
1. ALL MATERIALS AND WORK SHALL BE FURNISHED AND INSTALLED IN
WORKMANSHIP -LIKE MANNER IN STRICT ACCORDANCE WITH ALL
PREVAILING LOCAL, STATE, AND NATIONAL BUILDING CODES.
2. CONTRACTORS SHALL STORE, HANDLE, AND INSTALL ALL PRODUCTS AND
ASSEMBLIES PER THE MANUFACTURER'S INSTRUCTIONS,
RECOMMENDATIONS, AND PROCEDURES IN ORDER TO ENSURE THE
MANUFACTURER'S WARRANTY IS VALIDATED.
3. SUB -CONTRACTORS SHALL VERIFY ALL DIMENSIONS.
4. ALL DIMENSIONS ARE GIVEN FROM STUD TO STUD, UNLESS OTHERWISE
NOTED.
5. STUD DIMENSIONS ARE 31/2" OR 51/2" UNO.
6. ALL EXTERIOR WALLS ARE TO BE 2z6 STUDS. REFER TO STRUCTURAL FOR
OTHER LOCATIONS.
7. UNIT LAYOUT IS AS SHOWN ON W SCALE PLANS. FOR BUILDING
DIMENSIONS, REFER TO 1/8" SCALE OVERALL BUILDING FLOOR PLANS.
8. GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL,
PLUMBING, AND ELECTRICAL CONTRACTOR S FOR ALL RESPECTIVE
OPENINGS, AS REQUIRED, INCLUDING MAINTAINING FIRE RATED
ASSEMBLIES.
9. FOR MATERIALS AND FINISHES, REFER TO FINISH SCHEDULES ON THIS
SHEET.
10. TYPE "X" 5/8" THICK GYPSUM BOARD SHALL BE USED AT RATED WALL
CONSTRUCTION INCLUDING BEARING WALLS. TYPE "C" 5/8" GYPSUM BOARD
SHALL BE USED AT CEILINGS. REFER TO ILL ASSEMBLIES.
11. ALL CEILING ASSEMBLIES ARE TO BE MIN. 1 HOUR FIRE RATED
CONSTRUCTION WITH DAMPERS AT ALL DUCT PENETRATIONS. REFER TO
MECHANICAL DRAWINGS.
12. ALL WALLS WHICH FORM PERIMETERS OF DWELLING UNITS AND ALL LOAD
BEARING WALLS SHALL BE MIN. 1 HOUR FIRE RATED UL-U305 OR UL-1,1314
ASSEMBLY. NON -LOAD BEARING INTERIOR PARTITIONS WITHIN DWELLING
UNITS DO NOT REQUIRE FIRE RATING.
13. USE MIN. 3/8'OSB AT ALL ATTIC DRAFT STOPS.
14. REFER TO STRUCTURAL FOR ALL WINDOW AND DOOR HEADER SIZES.
15. CONTRACTOR TO PROVIDE: (1) 12" WOOD SHELF AND ROD IN ALL ENTRY
CLOSETS, (1) 12" WOOD SHELF, ROD, AND VERTICAL SHELVING IN BEDROOM
CLOSETS, (1) 12" WOOD SHELF AT LAUNDRY, (5) 12" DEEP WOOD SHELVES IN
LINEN CLOSETS, AND (5) 18' DEEP WOOD SHELVES IN PANTRY. PROVIDE
SHELVES IN BATH ROOM AS SHOWN. REFER TO DRAWINGS.
16. REFER TO STRUCTURAL DRAWINGS FOR INTERIOR BEARING WALL MEMBER
SIZE AND SPACING.
17. FLOOR TOPPING TO BE 3/4" GYPCRETE 2000 OR APPROVED EQUAL.
CONTRACTOR TO ADJUST STAIR RISER HEIGHTS AND DOOR HEADER
HEIGHTS ABOVE SUB -FLOOR ACCORDINGLY.
18. CONTRACTOR TO PROVIDE PAPER FACED INSULATION FOR ALL EXTERIOR
WALLS. PROVIDE TYVEK VAPOR BARRIER ON ALL EXTERIOR WALLS.
19. ALL WALLAND CEILING GYPSUM BOARD TO BE SMOOTH FINISH COATING.
REFER TO FINISH SCHEDULE FOR SHEEN.
20. PROVIDE WASHERAND DRYER HOOKUPS IN ALL UNITS AS REQUIRED TO
MEET OR EXCEED APPLICABLE CODES.
21. DWELLING UNIT SEPARATION WALLS OF APARTMENT UNITS SHALL BE MIN,
ONE HOUR FIRE RATED CONSTRUCTION.
22. PROVIDE WOOD BLOCKING SUPPORT AS REQUIRED. INCLUDING, BUT NOT
LIMITED TO: ALL LOCATIONS FOR GRAB BARS IN ALL UNITS AND AT ALL
STAIR RAILS, SUPPORT FOR SHEATHING EDGES NOT ON FRAMING, KITCHEN
WALL CABINETS ON ALL FLOORS, AND AT TV WALL LOCATIONS.
23. PROVIDE R-13 (3 %°) MIN. ACOUSTIC BATT INSULATION IN ALL DWELLING
UNIT SEPARATION WALLS. IN CEILINGS PROVIDE R-13 (3 %") MIN. ACOUSTIC
BATT INSULATION AT LOCATIONS WHERE OCCUPIED SPACE ABOVE HAS A
HARD FLOOR SURFACE. PROVIDE R-19 (51/2") MIN. PAPER FACED THERMAL
BATT INSULATION IN EXTERIOR WALLS. PROVIDE R-30 (9") MIN. IN CEILING
ABOVE GARAGES. PROVIDE R-38 (11") MIN. IN CEILING BELOW ROOF AREAS.
24. ALL LIVING UNITS SHALL BE CONSTRUCTED TO COMPLY WITH OBC
ADAPTABLE UNIT TYPE "B" REQUIREMENTS, UNLESS DESIGNATED ADA
ACCESSIBLE UNIT TYPE "A" IN UNITS LOCATIONS SHOWN.
25. PROVIDE CONTROL JOINTS IN CORRIDOR GYPSUM BOARD CEILING 30 FEET
O.C. WITH RESILIENT CHANNELS, TYPICAL.
26. STRUCTURAL MEMBERS SUPPORTING MORE THAN ONE FLOOR SHALL BE
INDIVIDUALLY PROTECTED BYA ONE -HOUR FIRE RESISTANCE RATED
ASSEMBLY.
GENERAL NOTES - ACCESSIBILITY
ALL DWELLING UNITS SHALL COMPLY WITH THE FOLLOWING:
1. THE HEIGHT OF THE WATER CLOSET SHALL BE AT LEAST 15" AND NO MORE
THAN 19" MEASURED TO THE TOP OF THE TOILET SEAT.
2. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A BRAG BAR OR
HANDRAIL SHALL BE 1.1W TO 1-1/2".
3. THE STRUCTURAL STRENGTH OF GRAB BARS, BATH TUB SEATS FASTENERS
AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS
3.1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCES BY THE MAXIMUM
BENDING MOMENT FROM THE APPLICATION OF 250 LBF SHALL BE LESS
THAN THE ALLOWABLE STRESS OF THE MATERIAL OF THE GRAB BAR OR
SEAT.
3.2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION
OF 250 LEE SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR
THE MATERIAL OF THE GRAB BAR OR SEAR. IF THE CONNECTION
BETWEEN THE GRAB BAR AND ITS MOUNTING BRACKET OR OTHER
SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND
TORSIONAL SHEAR STRESSES SHALL BE TOTALED FOR THE COMBINED
SHEAR STRESS, WHICH SHALL NOT EXCEEDED THE ALLOWABLE SHEAR
STRESS.
3.3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM
THE APPLICATION OF 250 LEE SHALL BE LESS THAN THE ALLOWABLE
LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR
THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER
ALLOWABLE LOAD.
3.4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE
OF 250 LEE PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF
250 _BF SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL AND THE
SUPPORTING STRUCTURE.
3.5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
TYPE'B' ACCESSIBLE UNIT
ALL UNITS NOT DESIGNATED AS TYPE W PER BUILDING FLOOR PLAN SHEETS A2-101
THRU A2-104B
1. PRIMARY ENTRANCE DOOR HARDWARE TO BE LEVER TYPE. LOCKING
MECHANISM TO BE ACCESSIBLE PUSH BUTTON TYPE PER ANSI 1003.5
2. ALL THRESHOLDS TO BE 1/2" MAXIMUM CHANGE IN LEVEL FROM TOP OF
THRESHOLD TO FINISHED FLOOR. PATIO SURFACE SHALL BE 4" MAXIMUM
BELOW FLOOR LEVEL OF ADJACENT INTERIOR SPACE
3. TOILET CENTERLINES SHALL BE 18" (MIN.) FROM WALL MEASURED FROM
FACE OF DRYWALL.
4. PRIMARY ENTRANCE DOOR SHALL BE 36" WIDE AND HAVE 18" (MIN.) PULL
SIDE CLEARANCE.
5. INTERIOR UNIT PASSAGE DOORS SHALL BE 34" WIDE (MIN.).
6. INSTALL BLOCKING FOR FUTURE GRAB BARS ATTOILETS AND TUBS
74 A
WOULPEPT
ARCHITECTURE tNCINEERINGIcEoaPATIAL
7635 Interactive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
09
no
u
IM
L
mfm=j
E
cam
Qlssuanees:
eev
neacmnieN
Mae
0
Issued For Building 2 Review
10/05/18
1
ASI#4
12/21/18
2
Issued For Building 2Permit
05/01/19
Prom. No.: 074904
Date: 10/05/18
A Sheet Name:
UNIT PLANS
SCALIL: 1/4' = 1'-U
FYAEA [lip