HomeMy WebLinkAbout(09) A2-5042 I 3 I 4 I 5 I 6 I 7 I 8 I 9
10 VB'
F4
El
EPDM CUSTOM
CURB FLASHING
EPDM MEI
TYPE
EPDM REINFORCED
CURB CORNER SIZES
SIZE OF FINISHED CURB
7"
12" x 12"
13"
24" x 24"
19"
36" x 36"
25"
48" x 48"
37"
72" x 72"
31"
60" x 60"
AD WELD AT
INING LAP OF CURB
ASHING (TYP.)
!RTICAL T-JOINT
)VER - TYP.
.,JT EDGE SEALANT
c1 ROOF CURB FLASHING DETAIL
SCALE: 1" = 1'-0"
STRAINER BASKET
EPDM MEMBRANE
COMPRESSION RING EPDM BONDING ADHESIVE
12" (ADHERED SYSTEMS ONLY)
1" MAX. o�
INSULATION
SUBSTRATE
1/2• MIN. CONTINUOUS BEAD OF WATERBLOCK
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations DRAIN DETAIL
of State and local Codes =1'-0"
City of Carmel
DATE: 10/31/19
F3 �, EIFS CORNICE TYPE 3
' SCALE: 3" = 1'-0"
WOOD NAILER (SEE NOTES)
EPDM MEMBRANE
BONDING ADHESIVE
CANT STRIP
HD OR HD PLUS SEAM PLATE POSITIONED
1W MIN. BEYOND TOE OF CANT
FASTENER AND HD
HID PLUS SEAM PLATE AT STRIP
OR O.C. X. SPLICE TAPE
NOTES)� SINGLE IS NOT REQUIRED.
WALL/CURB
3' SINGLE PLY QUICKPRIME PRIMER
QUICKSEAM fi QUICKSEAM FLASHING
PROTECTION BOARD
SUBSTRATE
fi' MAX.
NOTES:
1. REFER TO MFR. WEBSITE FOR MOST 3. IN CASE OF OBSTRUCTION REFER TO BASE
CURRENT INFORMATION.
2. MAXIMUM 6• LONG FASTENERS. 4. REFER TO QUICKSEAM LAYOUT DETAIL
(NOTE: WOOD BLOCKING MAY BE SUBSTITUTED QUICKSEAM RFP STRIP LAYOUT.
FOR INSULATION TO REDUCE FASTENER LENGTH
REQUIREMENT).
1NIT=DETAIL AT PARAPET/WALL
RA_�. �:1IBi1Ca1Y
CONTINUOUS BEAD
OF WATERBLOCK
4 FLASHING DETAIL
A2-505 SCALE: 3" = 1'-0"
FIELD FABRICATED MTL
HOOD BY OTHERS
(OPTIONAL).
FASTNER SEAM PLATE
@ 12" O.C. MAX.
PRE -MOLDED EPDM —
PIPE FLASHING
2"
MIN.
WELDED SPLICE
WALU CURB (MASONRY / CONCRETE SUBSTRATE ONLY)
CONTINUOUS BEAD OF HIGH GEADE SEALANT
APPROPRIATE FASTENER 12" O.C. MAX.
CONTINUOUS BEAD OF SEALANT
TERMINATION BAR
APPROPRIATE FASTENER 12" O.C. MAX
METAL COUNTERFLASHING, 3" MIN FACE
EPDM MEMBRANE CURB FLASHING
BONDING ADHESIVE
USE APPROPRIATE BASE TIE-IN
CONTINUOUS BEAD OF AP SEALANT OR HIGH
GRADE SEALANT
CONTINUOUS BEAD OF ULTRAPLY EPDM
SEALANT
STAINLESS STEEL CLAMPING RING
PIPE PENETRATION DETAIL
SCALE: 3" = 1'-O
EPDM BONDING ADHESIVE
(ADHERED SYSTEM ONLY)
EPDM MEMBRANE
INSULATION
SUBSTRATE
EIFS CORNICE TYPE 4
ccnl F.
3" EXTERIOR INSULATION FINISH SYSTEM
CONTINUOUS BEAD OF SEALANT
FRY REGLET
EPDM TERM BAR
— REGLET SNAP LOCK
FLUID APPLIED AIR BARRIER
AS PART OF THE EIFS
SYSTEM (SHOWN DASHED)
FASTENER AND SEAM PLATE w
EPDM FLASHING MEMBRANE a o
CUT EDGE SEALANT °o
EPDM FIELD MEMBRANE rc
FLASHING DETAIL D8 EI
scnl F- s" = 11-11" cc
1-1/4" HOT DIPPED
GALVANIZED ROOF
NAILS @ 12" O.C.
MAX.
WOOD NAILER
INSULATED METAL CURB
INSULATION
FASTENER 12" O.C.
MAX.W/EPDM
SEALANT
WOOD NAILER
c6 ROOF CURB DETAIL
A2-105 SCALE: 3" = 1'-0"
e To 8•
FIELD FABRICATED MTL HOOD BY
OTHERS (OPTIONAL).
FASTNER SEAM PLATE @ 12" O.C.
MAX.
PRE -MOLDED EPDM
PIPE FLASHING
WELDED SPLICE -
PIPE PENETRATION DETAIL
SCALE: 3" = 1'-0"
R.T.U.
EPDM 18" CURB FLASHING OR MEMBRANE
EPDM BONDING ADHESIVE
CONTINUOUS BEAD OF WATERBLOCK
WELDED SPLICE
EPDM MEMBRANE
EPDM BONDING ADHESIVE
INSULATION
SUBSTRATE
CONTINUOUS BEAD OF EPDM SEALANT
STAINLESS STEEL CLAMPING RING
EPDM BONDING ADHESIVE
(ADHERED SYSTEM ONLY)
EPDM MEMBRANE
INSULATION
SUBSTRATE
ICE TYPE 2
EIFS CORNICE TYPE 1
SCALE: 3" = 1'-U"
w OULPERT
--�TT�
1RERITMURE INN I NEERINSISEOSPATILL
7635 Interactive Way
Suite 100
O Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
F
E
D
C
B
E
^0
\W\
n/
W
E
U
J
W
m
�
O
�
�
c
m
�
N
E CD
W
U�
c
`o m
F
�
o�
NE
U
m
•- m
GU
Q Issuances:
NEV
officlu M
DATE
0
Issued For Building 2 Review
10/05/18
1
Issued For Building 2Permit
05/01/19
Prom. No.: 074904
Date: 10/05/18
A Sheet Name:
ROOF DETAILS