Loading...
HomeMy WebLinkAbout(14) P2-0011 2 3 0 5 0 7 e 0 Na a DRAIN SCHEDULE MANUFACTURER TYPE BODY OUTLET STRAINER/GRATE TOP FINISH ADD.FEATURE ZURN/OATEY w yw gLL z Yz aw wo: r aH osuai w y❑m o w Ug Q U o �❑' rc a z m o z tt yyd 3 w Mz 0 Y z a Woww i a O> 9 � ` m 2 CATALOG NOS 0 d w w0 wQV Vw I tlV V G FD-1 OATEY 43569 ■ ■ 2" ■ 4" ■ ■ DSG1 OVERFLOW DRAIN OUTLET COVER Z199 OC ■ ■ ■ 1 RD-1 ROOFDRAINZ107-W2 ■ ■ 4" ■ 15" ■ ■ ■ OVERFLOW ROOF DRAIN ■ ■ 4" ■ 15" ■ ■ ■ OD-1 Z107-W4 NOTES: 1. SIZE AS REQUIRED GENERAL NOTES (PLUMBING) 1. REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES NOT INDICATED ON THE FLOOR PLANS. 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL THE PLUMBING SYSTEM AS PER THE STATE PLUMBING CODE AND APPLICABLE LOCAL CODES. 3. CONTRACTOR SHALL NOT SCALE THE CONTRACT DOCUMENTS FOR THE PURPOSE OF OBTAINING FINAL MEASUREMENTS. COORDINATE WITH ARCHITECTURAL PLANS AND ACTUAL FIELD CONDITIONS. 4. PLANS TO BE CONSIDERED DIAGRAMMATIC AND ALONG WITH SPECIFICATIONS, REFLECT A MINIMUM ACCEPTABLE STANDARD. ALL WORK SHALL CONFORM TO THE STATE PLUMBING CODE AND THE AMERICANS WITH DISABILITIES ACT GUIDELINES. 5. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL FEES AND PERMITS ASSOCIATED WITH HIS PORTION OF THE WORK. 6. PLUMBING CONTRACTOR SHALL COORDINATE ALL ASPECTS OF WORK WITH OTHER TRADES PRIOR TO AND DURING CONSTRUCTION/INSTALLATION. 7. WHEN A CONFLICT BETWEEN PLANS AND SPECIFICATIONS OR NOTES OCCURS. THE ENGINEER SHALL DECIDE WHICH GOVERNS. GENERALLY, THE MORE RESTRICTIVE, MORE SPECIFIC, OR STRICTER PROVISION SHALL GOVERN. IF ANY DISCREPANCIES ARE DISCOVERED ON THE PLANS OR BETWEEN THE PLANS AND THE SPECIFICATIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR AND OBTAIN CLARIFICATION OF THE INTENT FROM THE ENGINEER PRIOR TO CONSTRUCTION OR INSTALLATION OF PROPOSEDIMPROVEMENTS. 8. REFER TO ARCHITECTURAL DRAWINGS AND INTERIOR ELEVATIONS FOR EXACT LOCATIONS, FIXTURE HEIGHTS AND ACCESSIBILITY REQUIREMENTS. 9, PROVIDE CLEANOUTS OR WALL CLEANOUTS WHERE INDICATED ON PLANS. 10. ACCESS PANEL AT KITCHEN ISLAND PROVIDED BY GENERAL CONTRACTOR. 11. ALL PIPING SHALL BE SLOPED AT A MINIMUM OF 1/8" SLOPE. 12. ALL PIPING SHOWN ON FIRST THROUGH FOURTH FLOOR PLANS IS ABOVE CEILING, BELOW FLOOR ABOVE. 13. ACCESS PANEL AT KITCHEN ISLAND FURNISHED BYTHE GENERAL CONTRACTOR. ALL OTHER ACCESS PANELS PROVIDED BY THE PLUMBING CONTRACTOR. 14. PIPING RUN ABOVE 3RD AND 4TH FLOOR CEILINGS SHALL BE RUN BELOW/UNDERSIDE OF ROOF INSULATION. GENERAL NOTES (FIRE PROTECTION 1. FIRE SYSTEM SHALL BE SUPPLIED FROM STANDPIPE STUB PROVIDED IN GARAGE PROJECT. 2. STANDPIPE WILL BE CONSIDERED WET TYPE, SUPPLIED FROM FIRE PUMP. 3. STANDPIPE SYSTEM SHALL BE INTERCONNECTED AND PROVIDED WITH FIRE DEPARTMENT CONNECTION. 4. FLOW AND TAMPER SWITCHES SHALL BE PROVIDED AND INSTALLED BY THE SPRINKLER CONTRACTOR. WIRING CONNECTIONS AND EXTENSION TO MONITORING LOCATIONS SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 5, FIRE SUPPRESSION CONTRACTOR SHALL FURNISH AND INSTALL SPRINKLER SYSTEMS PER NFPA 13 GUIDELINES WITHIN RETAILAREAS AND NFPA 13R GUIDLINES IN RESIDENTIAL AREAS, STATE CODES AND LOCAL APPLICABLE CODES AND AMENDMENTS. 6, CONTRACTOR SHALL SECURE AND PAY FOR ALL FEES AND PERMITS ASSOCIATED WITH THEIR PORTION OF THE WORK. 7. CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THEIR WORK WITH OTHER TRADES PRIOR TO INSTALLATION / CONSTRUCTION. 8. WORK UNDER THE BUILDING#2 PROJECT SHALL CONSIST OF, BUT NOT LIMITED TO, FURNISHING, INSTALLATION, TESTING, AND WARRANTY OF FIRE SUPPRESSION PIPING INDICATED ON P2 SERIES DRAWINGS. 9. WHEN A CONFLICT BETWEEN PLANS AND SPECIFICATIONS OR NOTES OCCURS, THE ENGINEER SHALL DECIDE WHICH GOVERNS. GENERALLY, THE MORE RESTRICTIVE, MORE SPECIFIC, OR STRICTER PROVISION SHALL GOVERN. IF ANY DISCREPANCIES ARE DISCOVERED ON THE PLANS OR BETWEEN THE PLANS AND THE SPECIFICATIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR AND OBTAIN CLARIFICATION OF THE INTENT FROM THE ENGINEER PRIOR TO CONSTRUCTION OR INSTALLATION OF PROPOSEDIMPROVEMENTS. 10, PIPING RUN ABOVE 3RD AND 4TH FLOOR CEILINGS SHALL BE RUN BELOW/UNDERSIDE OF ROOF INSULATION. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Carmel FIXTURE SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL WASTE VENT HW CW SUPPLY/TRIM SUPPLY/STOP WASTE/TRIM TRAP/FIX. DRAIN ADD FEATURES NOTES CLEVELAND FAUCET GROUP MULTI 2" P-TRAP, 42X60 ACRYLIC DROPIN TUB WITH APRON. BT1 BATHTUB STERLING S711111120 2" 11/2" 1/2" 1/2" CFG46301CBNGR INTEGRAL W/ HOUSING DRAIN BRUSHED NICKEL FINISH ON TRIM. CONTRACTOR TO CFG45311 TUB/SHOWER VALVE DIRECT 522334 AND OVERFLOW PROVIDE LEFT OR RIGHT DRAINS PER PLANS. MULTI 2" P-TRAP, TO BE DETERMINED. PRESSURE BALANCE TUB/ BT2 BATHTUB, ACCESSIBLE STERLING 5711111120 2" 11/2" 1/2" 1/2" W/SYMMONS INTEGRAL HOUSING DRAIN SHOWER VALVE WITH STOPS. HAND HELD SHOWER 2 S-9603-X-PLR-1.5 TUB/$HOWER VALVE DIRECT 522334 AND OVERFLOW WITH 60" HOSE AND MINIMUM 300SLIDE BAR. CULTURED MARBLE TOP - WHITE POP-UP DRAIN WHITE UNDERMOUNT BOWL FOR CULTURED MARBLE LV1 LAVATORY MULTI HOUSING DIRECT SINGLE 37"x22"-CONTEMPO BS 11/2" 11/4" 1/2" 1/2" CLEVELAND FAUCET GROUP ANGLE SUPPLIES W/ INCL. 1-1/4"P-TRAP VANITY. BRUSHED NICKEL FAUCET WITH CERAMIC DOUBLE 61N22"-CONTEMPO BS CFG4610OBN STOPS WITH FAUCET DISC AND SINGLE LEVER HANDLE. CULTURED MARBLE TOP- WHITE POP-UP DRAIN WHITE UNDERMOUNT BOWL FOR CULTURED MARBLE LV2 LAVATORY, ACCESSIBLE MULTI HOUSING DIRECT SINGLE 37N22" - CONTEMPO B$ 1112" 11/4" 112" 1/2" CLEVELAND FAUCET GROUP ANGLE SUPPLIES W/ INCL. 1-1/4"P-TRAP VANITY. BRUSHED NICKEL FAUCET WITH CERAMIC 3 DOUBLE 61R22"-CONTEMPO BS CFG4610OBN STOPS WITH FAUCET DISC AND ADA APPROVED SINGLE LEVER HANDLE. MAXIMUM 7" DEEP BOWL. STOPS AT FAUCET, Met MOP BASIN PROFLO PFMB2424 3" 11/2" 1/2" 1/2" T&S Brass CHECK VALVES ON UNIT 3"P-TRAP ACCESSORIES TO BE DETERMINED. TBO667RGH WATER SUPPLIES 9" DEEP, 18 GAUGE UNDERMOUNT STAINLESS STEEL ANGLE SUPPLIES W/ STOPS TO SINGLE BOWL. BRUSHED NICKEL FINISH ON TRIM, SKi DOUBLE -COMPARTMENT SINK WITH PROFLO PFUC208 2" 11/2" 1/2" 1/2" CLEVELAND FAUCET GROUP SINK. ADDITIONAL SUPPLIES DISPOSER 1-12"P-TRAP CERAMIC DISC FAUCET WITH SPRAYER,DISPOSALIN- 1 DISPOSER CFGCM2519CSL WITH STOPS TO DISPOSER AND STRAINER SINK -ORATOR BADGER 1 WITH WHIP FOR ELECTRICAL DISHWASHER CONNECTION. DRAIN CONNECTIONS. CONNECTIONS. 4-318" DEEP, 18 GAUGE UNDERMOUNT STAINLESS ANGLE SUPPLIES W/STOPS DOUBLE BOWL WITH TWO DRAIN OUTLETS. BRUSHED SK2 DOUBLE -COMPARTMENT SINK WITH ELKAV ELUHAD311845 2" 11/2" 1/2" 1/2" CLEVELAND FAUCET GROUP TO SINK. ADDITIONAL DISPOSER NICKEL FINISH ON TRIM, CERAMIC DISC FAUCET WITH DISPOSER, ACCESSIBLE CFGCA42519CSL SUPPLIES WITH STOPS TO STRAINER 112"PTRAP SPRAYER, DISPOSAL IN-SINK-ERATOR BADGER 1 WITH 13 DISPOSERAND DISHWASHER WHIP FOR ELECTRICAL CONNECTION. DISHWASHER SUPPLY& DRAIN CONNECTIONS. WC1 TANKTYPE, FLOOR SETWATERCLOSET PROFLO PF5112WHM 3" 11/2" -- 1/2" UNIT ANG LE SUPP LY W/ STOP UNIT INTEGRAL PROFLO#PFTSE2000WH ELONGATED SEAT IN WHITE. PF1401TWH WC2 TANK TYPE, FLOOR SET WATER PROFLO PF5112WHM 3" 11/2" -- 1/2" UNIT ANG LE SUPP LY W/ STOP UNIT INTEGRAL PROFLO#P FTSCOF2000WH ELONGATED SEAT IN WHITE. CLOSET, ADA/17" RIM PF1403TWH SCHEDULE NOTES: 1. DISPOSER AS SELECTED BY OWNER. PROVIDE AIR SWITCH ON COUNTER TO CONTROL OPERATION OF DISPOSER. 2. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING LOCATIONS OF ALL COMPONENTS. 3. PROVIDE "TRUEBRO" HANDI-LAV GUARD INSTALLATION KIT MODEL #102 (WHITE) OR APPROVED EQUAL DETAIL KEY NOTES: (TYPICAL UNIT MECH. CL( 1. PROVIDE CONNECTION TO TANKLESS WATER HEATER. HEATER PROVIDED BY MECHANICAL CONTRACTOR. 2. PROVIDE HOT& COLD WATER MANIFOLD WITH INDIVIDUAL ISOLATION VALVES. ZURN QPPM(QUICK PORT) SERIES. DETERMINE MANIFOLD OUTLETS REQUIRED PER EACH UNIT. 3. PROVIDE STUB FOR CONNECTION BY MECHANICAL CONTRACTOR. 4. PIPING TO AND FROM HYDRONIC AIR HANDLER PROVIDED BY MECHANICAL CONTRACTOR. 5. GAS SUPPLY FROM GAS METER. 6. GAS SUPPLY TO GAS RANGE. PROVIDE GAS VALVE AND UNION AT CONNECTION. PIPING TO BE RUN BELOW FLOOR AND RISE IN ISLAND WALL. 7. 112" PEX SUPPLY PIPING TO EACH INDIVIDUAL FIXTURE. 8. CPVC WATER RISER, SEE PLANS FOR SIZES. 9. TYPE"L"COPPER PIPING FROM CONNECTION TO WATER RISER TO ALL COMPONENTS WITHIN CLOSET. 10. PROVIDE THERMOSTATIC MIXING VALVE PER ABBE 1069 GUIDELINES. POWERSANATTS 3/4"-#LFLM496-1. 11. COORDINATE EXACT MOUNTING LOCATION WITH TANKLESS WATER HEATER. 12. EXTEND T&PDISCHARGE TO FLOOR DRAIN FOR INDIRECT DISCHARGE. 13. PROVIDE DIRT LEG AT BASE. 14. TANKLESS WATER HEATER PROVIDED BY MECHANICAL CONTRACTOR. REFER TO DRAWING M2-501 FOR ELEVATION OF CLOSET. 15. HYDRONIC AIR HANDLER PROVIDED BY MECHANICAL CONTRACTOR. REFER TO DRAWING M2-501 FOR ELEVATION OF CLOSET. 16. COIL ASSEMBLY PROVIDED BY MECHANICAL CONTRACTOR. REFER TO DRAWING M2-501 FOR ELEVATION OF CLOSET. 17, REFRIGERANT PIPING PROVIDED BY MECHANICAL CONTRACTOR. 18. EXHAUST PIPING PROVIDED BY MECHANICAL CONTRACTOR. 19. INDICATES ADDITIONAL GAS SUPPLIES SERVING ADDITIONAL FLOORS. 20, PEX MANIFOLD. 21. GAS SUPPLY TO RANGE. DETAIL LEGEND: V� BALL VALVE BV DRAIN VALVE WITH HOSE THREAD DV �., CHECKVALVE CHHK TEMPERATURE AND PRESSURE RELIEF VALVE TP 1 T UNION CONNECTION NM WATER METER T DIRECTION OF FLOW La� TEMPERING VALVE TV - CW - COLD WATER - HW - HOT WATER GAS VALVE GV - NG - GAS PIPING (NAT.) TYPICAL UNIT MECHANICAL CLOSET PIPING - ISOMETRIC NOT TO SCALE :1 REFRIGERANT TYPICAL UNIT MECHANICAL CLOSET - PLAN ET-1 EXPANSION TANK �C2-uuy 1 1/2" = 1'-0" RISER G ALL i C ( PLUMBING LEGEND SYMBOL DESCRIPTION VENT PIPING SANITARY PIPING BAN- - DOMESTIC COLD WATER PIPING - - - DOMESTIC HOT WATER PIPING OD OVERFLOW DRAIN PIPING NATURAL GAS PIPING ALL VAL PIPE UP PIPE DOWN OKEYNOTE DESIGNATION 'O ISOMETRIC DESIGNATION OUP TO ABOVE 1 P-001 DETAIL DESIGNATION CO CLEANOUT FD FLOOR DRAIN WHYD WALLHYDRANT OD OVERFLOW DRAIN DS STORM DOWNSPOUT ODS OVERFLOW DOWNSPOUT LV LAVATORY SAN SANITARY ST STORM SK SINK SS SANITARY STACK VR VENT RISER VS VENT STACK VTR VENT THRU ROOF WC WATER CLOSET WCO WALL CLEANOUT NG NATURAL GAS FIRE PROTECTION LEGEND SYMBOL DESCRIPTION -F- FIRE PROTECTION PIPING SPRINKLER PIPING -S- AL ALARM FLOW SWITCH FS TS TAMPERSWITCH FDVC FIRE DEPARTMENT VALVE CABINET AL ALARM BELL FDC FIRE DEPARTMENT CONNECTION SP STANDPIPE FDV FIRE DEPARTMENT VALVE ORD GPi HAZARD DESIGNATION PLUMBING SHEET LIST SHEETNUMBER SHEETNAME P2-001 LEGEND, DETAILS, AND SCHEDULES P2-100 PLUMBING INTERSTITIAL AND FIRST FLOOR PLAN P2-101 PLUMBING SECOND AND THIRD FLOOR PLANS P2-102 PLUMBING FOURTH FLOOR PLANS P2-401 PLUMBING TYPICAL ENLARGED PLANS AND ISOMETRICS P2-402 PLUMBING TYPICAL ENLARGED PLANS AND ISOMETRICS P2403 PLUMBING TYPICAL ENLARGED PLANS AND ISOMETRICS P2-601 PLUMBING WATER ISOMETRIC P2-602 PLUMBING SANITARY AND VENT ISOMETRIC 11k1/ -ITT-- W O U L P E R T IRCRITEULMEjINGINEERINGI6EMATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E r Ito In n W E OL 0 U J•� J � W 0 W 0 0 N cam Em 0I� Urb W O (CO �a co O C L N N NE U M LLJ 0 .so Q Issuances: REv oacRMON MTe 0 Issued For Building 2 Reviea 10N5/18 1 ASI#4 1221/18 2 Issued For Building 2Permit 05101/19 3 ASI#10 09/11/19 Prom. No.: 074904 Date: 04/26/19 Sheet Name: LEGEND, DETAILS, AND SCHEDULES DATE: 10/31/19