HomeMy WebLinkAbout(16) M2-001u 2 3 9 9 I 7 1 W HVAC ABBREVIATION LEGEND PIPE SYMBOL LEGEND SCHEMATIC SYMBOL LEGEND A AMPS MC MECHANICAL CONTRACTOR +--CHWS­4 CHILLED WATER SUPPLY PIPE ICI PIPE DOWN MV/AV AIR VENT, MV-MANUALVENT;AV- AUTOMATIC VENT ACC ACR AIR COOLED CONDENSING UNIT ACR COPPER REFRIG PIPE MCA MD MINIMUM CIRCUIT AMPS MANUAL DAMPER !-CHWR� CHILLED WATER RETURN PIPE ,Y� PIPE UP AFF ABOVE FINISHED FLOOR MFF MATT FACED FIBERGLASS ♦-CWS� CONDENSER WATER SUPPLY PIPE ! Y ! TEE DOWN M� AUTOMATIC 2-WAY CONTROL VALVE ALUM ALUMINUM MI MALLEABLE IRON !-CWR� CONDENSER WATER RETURN PIPE �+ TEE UP APO AIR PRESSURE DROP MUA MAKE UP AIR ASJ ALL SERVICE INSULATION JACKET NC NOISE CRITERIA LEVEL t-DCW­4 DOMESTIC COLD WATER PIPE ✓ PIPE BREAK (FOR CLARITY) AUTOMATIC 3-WAY CONTROL VALVE B STEAM BOILER CA OUTSIDE AIR !-HWS--i HEATING HOT WATER SUPPLY PIPE CAPPED PIPE BAS BUILDING AUTOMATION SYSTEM OBD OPPOSED BLADE DAMPER !-HWR� HEATING HOT WATER RETURN PIPE •r,T�' GAS SHUT-OFF VALVE AUTOMATIC FLOW CONTROLLER BDD BACKDRAFT DAMPER O.C. ON CENTER BHP BRAKE HORSE POWER ODU OUTDOOR UNIT ♦-CLYS­4 ICE WATER SUPPLY PIPE S BALL VALVE BOD BOTTOM OF DUCT PC PLUMBING CONTRACTOR !-GLYR­4 ICE WATER RETURN PIPE BUTTERFLY VALVE CHECK VALVE BOP BOTTOM OF PIPE PC PRESSURE DROP BR BRAZED PGGS PAINT GRIP GALVANIZED STEEL I-DTS� DUAL TEMPERATURE SUPPLY PIPE L_ 7 UNION C-AL CAL CORRUGATED ALUMINUM CALCIUM SILICATE INSULATION PP PPM POLYPROPYLENE PARTS PER MILLION ✓-DTR� DUAL TEMPERATURE RETURN PIPE {; CALIBRATED BALANCE VALVE FLEXIBLE CONNECTION CCP CALCIUM CARBONATE POWDER PRESS. PRESSURE ♦-DHW­i DOMESTIC HOT WATER PIPE 7ri PRESSURE REGULATING VAVLE CIF CUBIC FEET PRV PRESSURE REGULATING VALVE !-_VVENT PIPE GLOBE VALVE TR _ F GAUGE, T-TEMPERATURE; P-PRESSURE CFM CUBIC FEET PER MINUTE PS PRESSURE SENSOR ♦-G� NATURAL GAS PIPE GATE VAVLE CH CHILLER PVC POLYVINYL CHLORIDE CHP CHILLED WATER PUMP PVCGS PVC COATED GALVANIZED STEEL J-LPG� LIQUID PROPANE GAS PIPE STRAINER WITH BLOW DOWN VALVE �'� MANUAL BALANCE VALVE CHIN CHILLED WATER RA RETURN AIR !-RL� REFRIGERANT LIQUID PIPE ? Y STRAINER CHWR CHILLED WATER RETURN RC ROOM CRITERIA LEVEL CHWS CHILLED WATER SUPPLY RECT RECTANGULAR ♦-RSA REFRIGERANT SUCTION PIPE F­i BLIND FLANGE PIPE REDUCER/INCREASER CI CAST IRON REFRIG. REFRIGERANT J-RHG­f REFRIGERANT HOT GAS PIPE ! 4 7 MOTORIZED 2-WAYVALVE CL CENTERLINE RL REFRIGERANT LIQUID CLP CENTERLINE OF PIPE RF RETURN OR RELIEF FAN !-LPS� LOW PRESSURE STEAM PIPE _ p �tl-� MOTORIZED 3-WAY VALVE PRESSURE REDUCING VALVE CMC CONC. CEILING MOUNTED CENTRIFUGAL FAN CONCRETE RMC RMP ROOF MOUNTED CENTRIFUGAL FAN ROOF MOUNTED PROPELLER FAN NMPS� MEDIUM PRESSURE STEAM PIPE J-HPS� HIGH PRESSURE STEAM PIPE I-CRCONDENSATE RETURN PIPE l�'L PRESSURE RELIEF VALVE SHUTOFF VALVE CPVC CHLORINATED PVC RTU ROOF TOP UNIT CR CRP STEAM CONDENSATE RETURN CONDENSATE RETURN PIPE RV S RELIEF VALVE SWITCH ♦-FWD FEED WATER PIPE awa PRESSURE GAGE F THERMOMETER COMBINATION BALANCE -SHUTOFF VALVE CS CARBON STEEL SA SUPPLY AIR CT COOLING TOWER SC SENSIBLE CAPACITY CU COPPER SCH SCHEDULE TDV TRIPLE DUTY VALVE; SHUTOFF -BALANCE -CHECK DUCTWORK SYMBOL LEGEND CW CONDENSER WATER SCR SCREWED (THREADED) CWP CONDENSER WATER PUMP SF SUPPLY FAN SAFETY RELIEF VALVE D DRAIN SO SHUT OFF VALVE TERMINAL a3-r� n I SUPPLY OR OUTSIDE AIR DUCT RADIUS RECTANGULAR ELBOW DB DECIBELS SQ SQUARE DCW DOMESTIC COLD WATER SS STAINLESS STEEL DIRECTION OF FLOW ICI f RETURN OR EXHAUSTAIR DUCT UP ( SUPPLY OR OUTSIDE AIR ROUND 0 W DUCTUP CDC DIRECT DIGITAL CONTROLS SW SWEAT CONNECTION DHW DOMESTIC HOT WATER SWLD SOLVENT WELD DMPR DAMPER T THERMOSTAT SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN OR EXHAUST AIR ROUND DUCT UP DS DUCT SILENCER (SOUND ATTENUATOR) TC TOTAL CAPACITY DT DUALTEMPERATURE TEMP. TEMPERATURE DTP DUAL TEMPERATURE PUMP TH THICKNESS � RETURN OR EXHAUST AIR DUCT DOWN ROUND DUCT DOWN DTR DUAL TEMPERATURE RETURN THIRD THREADED DTS DUAL TEMPERATURE SUPPLY TOD TOP OF DUCT E-AL EMBOSSED ALUMINUM TOJ TOP OF JOIST �� SUPPLY/ OUTSIDE AIR DUCT OFFSET ROUND OFFSET EAT ENTERING AIR TEMPERATURE TOS TOP OF STEEL EC ELECTRICAL CONTRACTOR TS TEMPERATURE SENSOR EDB ENTERING DRY BULB TEMPERATURE T/S PIPE TYPE OR SCHEDULE �. RETURN AIR DUCT OFFSET ROUND ELBOW \ffi EF EXHAUST FAN UBC UPBLAST CENTRIFUGAL FAN EH ELECTRIC HEATER UC FLEXIBLE UNICELLULAR EWB ENTERING WET BULB TEMPERATURE UH UNIT HEATER MANUAL BALANCING DAMPER ROUND WYE EWT EXH ENTERING WATER TEMPERATURE EXHAUST UV V UNIT VENTILATOR VOLTS F FURNACE VAV VARIABLEAIRFLOW MOTORIZED DAMPER ELI RECTANGULAR BRANCH TAKEOFF FCU FANCOIL UNIT VC VENTILATING CONTRACTOR FD FIRE DAMPER WCS WROUGHT CARBON STEEL FIREDAMPER Vl RECTANGULAR DUCT TERMINATION FFJ FOIL FACED JACKET WCU WROUGHT COPPER FG FIBERGLASS WILD WELDED CONNECTION FGB FIBERGLASS BOARD INSULATION WMP WALL MOUNTED PROPELLER FAN RECTANGULAR TO ROUND TRANSITION �J ROUND DUCTTERMINATION FGW FIBERGLASSWRAP WPD WATER PRESSURE DROP FLA FULL LOAD AMPS WT WEIGHT (OR DENSITY) FLG FLANGE RECTANGULAR TRANSITION •--�� FLGD FLANGED FMG FOAM GLASS FPM FEET PER MINUTE r, I STANDARD RECTANGULAR ELBOW I 1 FPP FAN POWERED PARALLELVAV FPS FAN POWERED SERIES VAV FS FLOW SWITCH ANNOTATION SYMBOL LEGEND FSD FIRE/SMOKE DAMPER FIN FEED WATER Q THERMOSTAT OR TEMP. SENSOR QH HUMIDISTAT SECTION SYMBOL 100 G NATURAL GAS GA GAGE (GAUGE) GALV GALVANIZED SWITCH GC GENERAL CONTRACTOR GPH GALLONS PER HOUR X KEYNOTE DESIGNATION RTU EQUIPMENT PLAN MARK 12 GPM GALLONS PER MINUTE GRV GROOVED PIPE POINT OF NEW CONNECTION a GS GALVANIZED STEEL 4 DETAIL SYMBOL -100 H HUMIDIFIER (HUMIDITY) 1-01 VAV TERMINAL UNIT MARK HC HEATING CONTRACTOR 6LW-1 EQUIPMENTMARK HF HI A-8'¢ A-24x12 AIR DEVICE MARK - NECK SIZE 250 250 AIRFLOW HG HOTOT GAS GAS (REFRIGERANT) HP HORSEPOWER 8'o ROUND DUCT SIZE HPS HIGH PRESSURE STEAM HRC HEAT RECLAIM WATER 24x12 RECTANGULAR DUCT SIZE HS HUMIDITYSENSOR AIR DEVICE AND DUCT ACCESS. LEGEND HV HEATING/VENTILATINGUNIT HW HEATING HOT WATER HWB HOT WATER BOILER RETURN AIR GRILLE SUPPLY AIR DIFFUSER �� (HARD CONNECTION) HWP HOT WATER PUMP HWR HOT WATER RETURN Imo, SUPPLYAIR DIFFUSER WITH FLEXIBLE ICI"'� RUNOUTAND DAMPER �: RETURN OR EXHAUST GRILLE L�)ILJ (HARD CONNECTION) HWS HOT WATER SUPPLY ILC INLINE CENTRIFUGAL FAN LAT LEAVING AIR TEMPERATURE SIDEWALL DIFFUSER T 14X14 TRANSFER OPENING IN WALL LDB LEAVING DRY BULB TEMPERATURE LP LIQUID PROPANE LPS LOW PRESSURE STEAM SUPPLY AIR DIFFUSER �L (HARD CONNECTION) TRANSFER OPENING IN WALL LVR LOUVER LWB LEAVING WET BULB TEMPERATURE LWT LEAVING WATER TEMPERATURE RETURN OR EXH. GRILLE (HARD CONNECTION) M MOTORIZED MAT. MATERIAL MBH 1000 BTUH DESIGN CRITERIA I PROJECT NOTES I CONTROL NOTES: 1. PROVIDE PROJECT SPECIFIC CONTROL SYSTEM MANUAL FOR THE BUILDING. THE MANUAL SHALL CONTAIN A DIAGRAM OF THE CONTROL SYSTEM ARCHITECTURE, WIRING DIAGRAMS AND A SEQUENCE OF OPERATION. THE MANUAL SHALL ALSO INCLUDE AN 11 X 17 FLOOR PLAN INDICATING THE MAJOR EQUIPMENT AND PANEL LOCATIONS. THE MANUAL SHALL BE BOUND IN A HARD BACK 3 RING BINDER WITH DIVIDERS. BINDER SHALL BE LABELED'H.V.A.0 TEMPERATURE CONTROL MANUAL' AND INCLUDE THE PROJECT NAME AS WELL AS THE BUILDING NAME, NUMBER AND ADDRESS. 2. LABEL ALL CONTROL PANELS, ACTUATORS, SENSORS, ETC WITH 118' THICK PLASTIC LAMINATE SIGNS. SEE DRAWINGS FOR LABEL AND LETTERING REQUIREMENTS. LABEL DESIGNATIONS SHALL BE CONSISTENT WITH THE DRAWINGS, TEMPERATURE CONTROL SYSTEM MANUAL AND DIAGRAMS. 3. MOUNT WALL MOUNTED THERMOSTATS, TEMPERATURE SENSORS AND CARBON MONOXIDE SENSORS 4'-0' ABOVE FINISH FLOOR. DO NOT MOUNT THERMOSTATS OR TEMPERATURE SENSORS IN DIRECT SUNLIGHT OR NEAR HEAT PRODUCING EQUIPMENT. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MOTOR STARTERS AND DISCONNECT SWITCHES FOR H.V.A.C. EQUIPMENT UNLESS THEY ARE INCLUDED WITH THE EQUIPMENT AS INDICATED ON THE DRAWINGS AND IN THE SPECIFICATIONS. COORDINATE STARTER REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR AND THE CONTRACTOR PRIOR TO ORDERING. 5. WHERE AUXILIARY CONTACTS ARE REQUIRED IN STARTERS PROVIDED BY THE ELECTRICAL CONTRACTOR, THE MECHANICAL CONTRACTOR SHALL COORDINATE THE QUANTITYAND TYPE OF CONTACTS WITH THE E.C. PRIOR TO PURCHASE. 6, THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUIT BREAKERS IN THE ELECTRICAL PANELS THAT ARE SPECIFICALLY DEDICATED FOR THE TEMPERATURE CONTROL SYSTEM. COORDINATE THE QUANTITY AND SIZES WITH THE CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR LOCATION. 7. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALLTEMPERATURE CONTROL SYSTEM WIRING AND CONDUIT REGARDLESS OF VOLTAGE AS REQUIRED TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATION OR SATISFYANY MANUFACTURER REQUIREMENTS. POWER AND CONTROL WIRING AND CONDUIT FOR VALVE ACTUATORS, DAMPER ACTUATORS, CARBON MONOXIDE SENSORS, TEMPERATURE CONTROL PANELS, RELAYS, INDICATOR LIGHTS, REMOTE CONTROL PANELS, SOLENOID VALVES AND OTHER SIMILAR DEVICES THAT ARE PART OF THE H.V.A.0 SYSTEM SHALL BE PROVIDED BV THE MECHANICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR THE LOCATION OF CIRCUIT BREAKERS SPECIFICALLY DEDICATED FOR TEMPERATURE CONTROL SYSTEM COMPONENTS. ALL 120 V CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. CONCEALED ABOVE CEILING PLENUM RATED LOW VOLTAGE (24 VOLTS OR LESS) CONTROL WIRING DOES NOT REQUIRE TO BE INSTALLED IN CONDUIT. B. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROLS, RELAYS, SENSORS, CONTROLLERS, CONTROL TRANSFORMERS, CONTROL INTERFACE COMPONENTS, SOFTWARE, HARDWARE, ACTUATORS, SWITCHES AND ANY OTHER CONTROL COMPONENTS REQUIRED TO PROVIDE THE SPECIFIED SEQUENCE OF OPERATIONS ON PLANS, TO INTEGRATE PROJECT CONTROLS AND SYSTEM, AND TO MEET EQUIPMENT MANUFACTURER'S INSTALLATION AND OPERATION REQUIREMENTS, UNLESS NOTED OTHERWISE ON PLANS. 9. IT SHALL BE THE MECHANICAL CONTRACTORS RESPONSIBILITY TO COORDINATE ALL TEMPERATURE CONTROL SYSTEM REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR PRIOR TO THE PURCHASE OR INSTALLATION OF ANY OF THE ELECTRICAL POWER OR TEMPERATURE CONTROL SYSTEM COMPONENT. 10. ALL DAMPERS ON THE INLET OR OUTLET OF THE FAN SHALL BE OPEN PRIOR TO STARTING THE FAN. PROVIDE ANY TIME DELAYS OR END SWITCHES AS REQUIRED. 11. IN PUBLIC AREAS PROVIDE CLEAR PLASTIC VENTED IMPACT RESISTANT LOCKABLE GUARDS ON ALL WALL MOUNTED THERMOSTATS OR SENSORS WITH ADJUSTABLE SET -POINTS. IDENTIFICATION: 1. PROVIDE PLASTIC LAMINATE IDENTIFICATION LABELS ON ALL EQUIPMENT SCHEDULED ON THE DRAWINGS. THE IDENTIFICATION SHALL BE CONSISTENT WITH THE PLANMARKS SHOWN ON THE DRAWINGS AND THE BAS SYSTEM USER INTERFACE. SEE DETAILS ON DRAWINGS REGARDING COLOR, SIZE, TEXT HEIGHT, ETC. 2. PROVIDE PLASTIC LAMINATE IDENTIFICATION LABELS ON ALL TEMPERATURE CONTROL COMPONENTS SUCH AS CONTROL PANELS, TEMPERATURE SENSORS, HUMIDITY SENSORS, ETC. THE IDENTIFICATION SHALL BE CONSISTENT WITH THE PLANMARKS SHOWN ON THE DRAWINGS WHERE AVAILABLE AND THE BAS SYSTEM USER INTERFACE. SEE DETAILS ON DRAWINGS REGARDING COLOR, SIZE, TEXT HEIGHT, ETC. 3. PLASTIC LAMINATE SIGNS AND LABELS ON OUTDOOR EQUIPMENT SHALL BE FIXED TO EQUIPMENT WITH STAINLESS STEEL OR ALUMINUM RIVETS OR STAINLESS STEEL OR PLATED SCREWS. 4. CLEAN EQUIPMENT AND PIPING PRIOR TO AFFIXING ADHESIVE TYPE LABELS AND SIGNS. I PROJECT NOTES I GENERAL: 1. INSTALL THE H.V.A.C. SYSTEM AS INDICATED IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. 2. COORDINATE ALL WORK WITH OTHER TRADES. REWORK OF PIPING, DUCTWORK, EQUIPMENT LOCATION, CONDUIT, ETC. AS A RESULT OF POOR PLANNING. COORDINATION OR SCHEDULING SHALL BE THE RESPONSIBILITY OF THE INVOLVED CONTRACTORS. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS PRIOR TO START OF WORK. 3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ANY FRAMING REVISIONS, EQUIPMENT LOCATIONS, ADDITION OF CONTROLS, ELECTRICAL CIRCUITING REVISIONS, ETC. THAT RESULT FROM USING EQUIPMENT OTHER THAN THOSE INDICATED ON THE DRAWINGS. APPROVAL OF THE SHOP DRAWINGS BYTHE ARCHITECT/ENGINEER WILL NOT WAIVE THE CONTRACTOR OF THIS RESPONSIBILITY. 4. THE MECHANICAL CONTRACTOR SHALL HAVE THE FINAL RESPONSIBILITY FOR SYSTEM START UP, TRAINING, WARRANTY AND TURN OVER TO THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTRUCTING THE OWNER ON ANY ROUTINE MAINTENANCE REQUIRED DURING THE WARRANTY PERIOD. 5. ALL ITEMS INCLUDED ON THESE DRAWINGS AND THE SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACTORS BID. ANY ITEMS THAT ARE UNCLEAR OR FOUND TO BE INCORRECT BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO THE BID DUE DATE. EXCLUSIONS OF WORK FROM THE BID ARE NOT ACCEPTABLE. 6. ALL WORK INDICATED ON THE MECHANICAL DRAWINGS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. 7. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL FIRESTOPPING FOR DUCT AND PIPE PENETRATIONS THAT PENETRATE FIRE RATED ASSEMBLIES. SEE ARCHITECTURAL DRAWINGS OR REFER TO THE OWNERS RECORD DRAWINGS FOR LOCATIONS OF FIRE RATED ASSEMBLIES. ALL FLOOR PENETRATIONS SHALL BE FIRESTOPPED AND SEALED WATER TIGHT WITH A FLEXIBLE SEALANT. INSTALL PER MFG. RECOMMENDATIONS. B. THE MECHANICAL CONTRACTOR SHALL COORDINATE ANY ROOF PATCHING FOR ANY MECHANICALROOF PENETRATIONSNOTSPECIFICALLYIDENTIFIED THEARCHITECTURAL DRAWINGS. ALL PATCHING SHALL BE PROVIDED BY GENERAL CONTRACTOR AND BE PERFORMED IN A MANNER CONSISTENT WITH THE ROOF SYSTEMS CURRENT WARRANTY REQUIREMENTS AND MANUFACTURERS RECOMMENDATIONS. 9. THE MECHANICAL CONTRACTOR SHALL NOT PERFORM ANY WELDING OR TORCH CUTTING OPERATIONS WITHIN THE OCCUPIED BUILDING WITHOUT OBTAINING PERMISSION OR A BURN PERMIT FROM THE OWNER. DUCTWORK -GENERAL: 1. ALL DUCTWORK SHALL BE CONSTRUCTED, INSTALLED AND SUPPORTED PER THE LATEST VERSION OF THE S.M.A.C.N.A. H.V.A.C. DUCT CONSTRUCTION STANDARDS. UNLESS SPECIFIED MORE STRINGENTLY IN THESE CONSTRUCTION DOCUMENTS. 2. COORDINATION OF DUCT SYSTEM INSTALLATION WITH OTHER TRADES SHALL BE PERFORMED PRIOR TO THE FABRICATION OF ANY DUCTWORK. VERIFY DUCT CLEARANCES PRIOR TO FABRICATION. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS THAT REQUIRE DIMENSIONAL CHANGES OR REQUIRE MAJOR RELOCATION OF DUCTWORK. 3. ALL DUCTWORK SHALL BE SUPPORTED FROM ROOF OR FLOOR STRUCTURE ABOVE. DUCTWORK SHALL NOT LAY ON TOP OF CEILING OR LIGHT FIXTURES. 4. ALL DUCTWORK SIZES SHOWN ARE EXTERNAL DIMENSIONS. ALLOWANCE HAS BEEN MADE FOR 1' DUCTLINER WHERE AND IF REQUIRED. 5. RECTANGULAR DUCTWORK SHALL BE SUPPORTED PER THE S.M.A.C.N.A. STANDARDS AND AT EACH CHANGE IN DIRECTION. EQUIPMENT - GENERAL 1. THE H.V.A.C. EQUIPMENT AND SYSTEM SHALL NOT BE USED TO DURING CONSTRUCTION. THE WARRANTY PERIOD SHALL NOT BEGIN UNTIL SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL EXTEND THE EQUIPMENT WARRANTY PERIOD AS NECESSARY WHEN EQUIPMENT IS USED AFTER INITIAL START UP AND PRIOR TO SUBSTANTIAL COMPLETION. 74,E WOOLG EUT MCNITECTNE IENOINEw11N0I0ECWATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 No PEIINU247 STATE OF F E U � C J '- J K W U rn V I � c m O O c O N V U W O c 5 o c L � _ d �E U m = U B Dlssuances: GENERAL DESIGN INFORMATION INDOOR DESIGN CONDITIONS BUILDING STAIRWELL WINTER DRY BULB: 60.0°F LOCATION: CARMEL, INDIANA LATITUDE: 39.97 CORRIDORS AND TENANT ROOMS LONGITUDE: 86.13 ELEVATION: 853 WINTER DRY BULB: 70.0°F OUTDOOR DESIGN CONDITIONS WINTER RH%: AMBIENT SUMMER DRY BULB: 75.0°F SUMMERDRY 91.3-F (0.4%ASHRAE DESIGN SUMMERRHh: 60% MAX Prom. No.: 074904 BULB: CONDITION) SUMMER WET 75.0-F (0.4% ASHRAE DESIGN Date: 04126119 BULB: CONDITION) WINTER DRY 2.6°F (99.6% ASHRAE DESIGN BULB: CONDITION) RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel '1"19, MECHANICAL SHEET LIST SHEET NUMBER SHEET NAME M2-001 WAC LEGEND AND NOTES M2-101 WAC FIRST AND SECOND FLOOR PLAN M2-102 WAC THIRD AND FOURTH FLOOR PLAN M2-103 WAC ROOF PLAN M2401 WAC TYPICAL ENLARGED PLANS M2402 WAC TYPICAL ENLARGED PLANS M2501 WAC DETAILS M2-601 MAC SCHEDULES A Sheet Name: HVAC LEGEND AND NOTES M2=001 DATE: 10/31/19