(16) M2-501
2 I 3 I 4 I 5 I 6 I 7 I 6 I 9 fY m a L) U W N C m C) rn Nr Of E U Q 2 D_ N � WEIGHTED BACK -DRAFT DAMP FOR AIR RELIEF GRILLE (REFER TO PL FOR SIZE AND TYPE) SHEET METAL SLEEVI AIR RELIEF DETAIL NTS VALL LOUVER. SEAL ALL ,ROUND WITH SILICONE. EXTERIOR WALL ACCESS PANEL WITH LATCHES. PANEL SHALL BE RATED FOR STATIC PRESSURE SUPPLY, RETURN OR OF DUCT SYSTEM. PROVIDE INSULATED EXHAUST DUCT ACCESS PANELS FOR INSULATED OR LINED DUCT SYSTEMS. BREAK -AWAY 24 GAGE GALV. STEEL BLADES. DUCT CONNECTION 165 DEGREE FUSIBLE LINK 1.5"Xl5"X1/8" STEEL ANGLE BOLTED TO SLEEVE. GALV. STEEL SLEEVE METAL GAGE TO MATCH DUCT FLOOR SLAB SYSTEM. 24 GAGE MINIMUM. UL CLASSIFIED 1-1/2 HOUR 20 GAGE GALV. STEEL FRAME FIRE DAMPER FOR STATIC SYSTEMS O HORIZONTAL FIRE/SMOKE DAMPER DETAIL NTS SIDEWALL EXHAUST FAN OKEYED NOTES 1. SIDEWALL EXHAUST FAN WITH GRILLE 2. STUD WALL 3. OUTLET FLANGE 4. BACKDRAFT OR MOTOR OPERATED DAMPER (SEE SCHEDULE SPECS) 6. 4" METAL EXHAUST DUCT UP INTO CEILING SPACE AND OUT SIDEWALL WITH LOUVER. O © DOG HOUSE FOR REFRIGERANT PIIN NTS CEILING SLEEVE: MINIMU GUAGE FOR DAMPERS NI EXCEEDING 24"X24" 16 Gl FOR LARGER SIZES NOTE CONNECT SLEEVE TO DIFFU COLLAR ALL SIDES OF DEVIL AS REQUIRED BY U.L. LABEL LES 1-1/2" X 1-1/2" X 118" MUM; FASTENED TO SLEEVE AS UIRED BY U.L. LABEL; ANGLES TO MASONRY OPENING MINIMUM 1" )AMPER ED CEILING TION n CEILING/AIR DEVICE MOUNTED FIRE DAMPER DETAIL Q' NTS KEYED NOTES: 1. 2" x 4" TREATED NAILER 2. ANCHOR TO DECK 3. 1" LINED 4. OPENING THRU ROOF. SIZE BASED ON PIPING INSTALLATION REQUIREMENTS. 5. DOUBLE WALL 112" INSULATED CAP 6. 20 GAUGE GALV. SHEET METAL. 7. CANT REQUIRED FOR BUILT-UP ROOFING. DELETE CANT FOR ANY NON BUILT-UP ROOFING SYSTEM AND FLASH TO BELOW CURB CAP. 8. SECURE CAP TO BASE WITH 1 SCREW PER SIDE. 9. 24 GAUGE GALV. SHEET METAL THIMBLE FOR PIPE PASSAGE CAULK THIMBLE AT DOG HOUSE AND AT PIPE PENETRATION. REFER TO STRI'rn ions DRAWINGS FOF FASTEN WITH MASONRYANC EXHAUSTFAN FAN ENCLOSURE ALUMINUM BACKDRAFT DAMPER WITH COUNTER BALANCE WALL LOUVER SIMILAR TO RUSKIN ELF3750. REFER TO SPECIFICATIONS. SHEET METAL SLEEVE EXTERIOR WALL n EXHAUST FAN WITH LOUVER DETAIL ' NTS PREMANUFACTURED (ALUMINUM PAINTED GALVANIZED STEEL) HOOD 14" HIGH 18 GAGE BIRD SCREEN GALVANIZED STEEL WELDED CURB FILL GAPS WITH EXPANDABLE FOAM GRAVITY BACKDRAFT SEALANT DAMPER WITH BLADE SEALS, SHAFT SEALS DISCHARGE DUCT —' AND COUNTER BALANCE OROOF MOUNTED EXHAUST HOOD NITS GALVANIZED STEEL SLEEVE. METAL GAGE TO MATCH DUCT NOTE: MECHANICAL CONTRACTOR TO COORDINATE SYSTEM. 24 GAGE MINIMUM. UfR EXACT TRUSS LOCATION AND/OR TRUSS QUANTITY WITH ACTRUSS S LOCATION SUPPLY TRPLENUMON TOP OF HVAC UNIT TO EXTEND UP INTO TRUSS SPACE, NO TRUSSES TO BE LOCATED ABOVE SUPPLY AIR 1.5"X 1.5" X 1/8" STEEL ANGLE rT ^ PLENUM. BOLTED TO SLEEVE BREAK -AWAY DUCT CONNECTION / 24 GAGE GALVANIZED STEEL BLADES FUSIBLE LINK 20 GAGE STEEL BLADES �• `ACCESS PANEL WITH LATCHES. PANEL SHALL BE RATED FOR STATIC PRESSURE UL CLASSIFIED 1-1/2 HOUR FIRE OF DUCT SYSTEM. PROVIDE INSULATED DAMPER FOR STATIC SYSTEMS ACCESS PANELS FOR INSULATED OR LINED DUCT SYSTEMS. 2 HOUR FIRE RATED PARTITION. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS. nTYPE B VERTICAL FIRE DAMPER DETAIL `% NTS NOTE: ` A. CONDENSING UNITS MUST BE ANCHORED TO ROOF TO RESIST WIND FORCES - ANCHORAGE SHALL BE COORDINATED AND SPECIFIED BY MECH. CONTRACTOR AND EQUIPMENT SUPPLIER. RELEASED FOR CONSTRUCTION JPPORT RAIL Subject to compliance with all regulall of State and Local Codes City of Carmel DATE: 10/31/19 BRAMEC 4007BLK SCRE W UP FOOT AT EA. CORNER, INVERTED AND FASTENED TO UNIT DIVERSITECH MP4C ANTI -VIBRATION PADS ADHERED TO BOTTOM OF FOOT TPO SLIP SHEET PROTECTION LAYERAT EA. SUPPORT .060 TPO FULLYADHERED MEMBRANE ROOFING OVER 1/2" FIBER BD. OVER 3/4" CDX PLYWOOD SHEATHING ON ENGINEERED WOOD TRUSS CONSTRUCTION ROOFDECK ENT OR INTAKE -ESS STEEL BAND CLAMP ILE RUBBER OR 2ENE BOOT ILE SEALANT LES VENT THRU ROOF DETAIL NTS 12" FLEX DUCT 1V SUPPLY AIR PLENUM 2" PVC EXHAUST IN WALL w CLOSET a WALL r a 2" PVC INTAKE, SEE PLAN AND SCHEDULE — A -COIL (SEE SCHEDUL N 14N21N227 RINNAI w BLOWER (SEE SCHEDULE) U SIDE p FILTER RACK u of zW W CLOSET WALL J14'x22'X34'TW w m _ a I o � TRINNAI HEATER (SEE SCHEDULE) 18.5"x26.4"x11.4" 12" CLEARANCE MECHANICAL CLOSET SECTION A PLENUM REFRIGERANT LINES TO CONDENSING UNIT RINNAI HYDRONIC AIR HANDLER PUMP WITH 6 FLOW CHECK VALVE (IFC) PLUMBING EXPANSION TANK BLOWER ASSEMBLY FLEXIBLE DUCT. MAXIMUM LENGTH F-V. MINIMIZE ABRUPT OR SHORT RADIUS TURNS.(TENANT ROOMS EXEMPT FROM MAX LENGTH REQUIREMENT) STRAP HANGERS (TYP) -� PROVIDE INSULATED ROUND PIPE WHERE ENTIRE RUNOUT EXCEEDS 5'-0" IN LENGTH. SEE DUCT SCHEDULE ON DRAWINGS FOR INSULATION TYPE AND THICKNESS. VOLUME DAMPER WITH LOCKING QUADRANT AND POSITION INDICATOR DUCT COLLAR SEAL CONNECTION BETWEEN THE DUCT COLLAR AND THE DUCTWORK CEILING MOUNTED AIR DEVICE MAIN DUCT ACCESSIBLE CEILING NOTE: 1. SEAL ENDS OF FLEXIBLE DUCT WITH TAPE AND SEAL JOINTS BETWEEN THE DUCT COLLAR AND THE MAIN DUCT. 2. DAMPER QUADRANT SHALL PENETRATE THE INSULATION AND SUFFICIENT SPACE SHALL BE ALLOWED FOR OPERATION. rNSUPPLY OR EXHAUST RUNOUT DETAIL NTS EVAPORATOR COIL HYDRONIC HEATING COIL AIR SEPARATOR ill �h WFS HWR— s FLOW SENSOR THERMOSTAT CONTROL BOX VALVE STUBS FROM TANKLESS WATER HEATER BY P.C. NOTE: ALL PIPING TO BE POTABLE GRADE COPPER PIPING AND BRASS APPURTENANCES ONLY. TYPICAL PIPING ARRANGEMENT FOR DIRECT SPACE HEATING NTS %Ai -ITT-- WOULPERT IRCHITEETYREj NGINEERINGICEMATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E V� W D (^'0 W Q U C J J � Of y ��VVVAIIJJJ111 U U c m a0c ni N UM t� co o c s_ 6 m d B �U L Issuances: REv DEacRMON MTe 0 Issued For Building 2 Review 10/05/18 1 Issued For Building 2Permit 05/01/19 2 ASI#10 09/11/19 Prom. No.: 074904 Date: 04/26/19 A Sheet Name: HVAC DETAILS M2=501