HomeMy WebLinkAbout(18) E2-4012 3 0 7 E 0 R K U W J W N C C U ym O rn e n m K E D .E 2 0 a Panel Schedule PANEL NAME: PA1 VOLTAGE 208 PHASE: 1 WIRE: 3 NEUTRAL RATING: 1000/0 PANEL DESCRPTIOJ: TYPICAL 1-BEDROOM UNIT PANEL 100A MOUNTING RECESSED MAX. NO. OF CIRCUITS: 24 MANUFACTURER: Square D PANEL AI.C. RATING: 229000 LOCATION: NO BRANCH VA Load Load VA BRANCH POLES BI<R A B C Type 1 BEDROOM UCHTINGRECEPTS BATHROOM UI TINGRECEPTS,EF-1 1 1 2pt 20 1123 253 R R R E 20CD 1500 20 30 1 2 WASHER CLOTHES DRYER 2 3 4 5 7 9 11 ENTRY UWTINGRECEPTS LIVING ROOM LIGWINGRiECEPTS APPUANCERECEPTS APPLIANCERECEPTS 1 1 1 1 2M 2M 20t 20t 506 360 1282 180 830 R R R R E E E E E E E E 50D 950 38 2" 12W 950 - 15 15 15 - 15 - 1 1 2 - 1 RANGE MU-1 cw 4108 13 15 MICROWAVE GARBAGEOISPOSAL 1 1 20 20 1000 GWH1 17 19 DISHWASHER SPACE 1 - 20 - 800 - E - - - - - - SPACE SPACE 21 23 SPACE SPACE - - - - - SPACE SPACE ±22 NOTES: 1.+- ARC -FAULT CIRCUIT INTERRUPTER Total A k LIGHTING 0.1 0 0 0 0 0 RECEPTS tR] 1989 3215 0 52 34 EQUIP. F-1 5288 4980 0 10268 66 OTHER 0 0 0 0 0 ADDITIONAL 0 0 0 0 0 TOTAL n2 81% 0 15472 DEMAND 5C94 5737 0 10830 70 % 47 53 0 UNIT 62-A1 - ONE BEDROOM 1 1 scALE: v4 7- 1. RELEASED FOR CONSTRUCTION J 2 Panel Schedule PANEL NAME: PA2 VOLTAGE 208 WIRE: 3 NEUTRAL RATING: 100% PANEL DESCRPTIOJ: TYPICAL 1-BEDROOM UNIT PANEL MAINS: 100A 2 MOUNTING RECESSED CIRCUITS: MANUFACTURER: Square D PANEL AI.C. RATING: 229000 LOCATION: NO BRANCHVA Load12� BRANCH POLES BB C Type 1 3 7 9 11 BEDROOM UCHTINGRECEPTS BATHROOM LICHTINGRECEPTS,EF-1 ENTRY UWTINGRECEPTS LIVING ROOM LIGWINGR CEPTS APPUANCERECEPTS APPLIANCERECEPTS 1 1 1 1 1 1 2W 264 212W 280 2360 i 253 830E R0 R R R R R E0 20 30 - 15 15 15 - 15 1 2 - 1 1 2 - 1 WASHER CLOTHES DRYER5 RANGE AHU-2 CU-2 2 4 6 8 10 12 13 15 MICROWAVE GARBAGEDISPOSAL 1 1 0D 14 GWH1 18 17 DISHWASHER SPACE 1 - 00 E- - - - - SPACE SPACE 1819 A 21 SPACE - - - - - - SPACE 22 24 NOTES: 1.+- ARC -FAULT CIRCUIT INTERRUPTER TOMI LIGHTING 0.1 0 0 0 0 0 RECEPTS JR] 21N 3313 0 M17 34 EQUIP. F-1 5408 51W 0 105C8 66 OTHER 0 0 0 0 0 ADDITIONAL 0 0 0 0 0 TOTAL 7512 8413 0 15925 DEMAND use Sears 0 11148 70 % 47 53 0 UNIT B2-A2 - ONE BEDROOM GENERAL NOTES A. ALL 120V, 15 A AND 20-A RECEPTACLES SHALL BE TAMPER RESISTANT. B. COORDINATE ALL KITCHEN AND KITCHEN ISLAND RECEPTACLES WITH ARCHITECTURAL ELEVATIONS. C. PROVIDE FIRE RATED ELECTRICAL BOXES IN ALL FIRE RATE WALLS, CEILINGS, AND ASSEMBLIES. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATINGS. DRAWING NOTES 1 PROVIDE 125/250V 30A-3P, 4 WIRE DRYER RECEPTACLE, 48" M.H. NEMA 14-30R. (3) #10, #10 GIRD . 0.75" C. 2 PROVIDE 125V ZOAAP RECEPTACLE, 18" 2 M.H. NEMA 5-ZOR. (2) #12, #12 GRD., 0.75" C 3 REFER TO ROOF POWER PLAN FOR LOCATION OF CONDENSING UNIT SERVING THIS RESIDENTIAL UNIT. DISCONNECT TO BE LOCATED ON ROOF, ADJACENT TO EQUIPMENT. 4 PROVIDE 20A-120V RECEPTACLE UNDER SINK FOR GARBAGE DISPOSAL AIR SWITCH. 5 PROVIDE CEILING MOUNTED JUNCTION BOX UL LISTED FOR FAN AND FIXTURE SUPPORT. PRE -WIRE FOR FUTURE PADDLE FAN AND LIGHT KIT. 6 PROVIDE RECEPTACLE AND CAN EQUIPMENT BOX AT 18" AFF AND AT 4'-9" AFF BETWEEN BLOCKING AT THIS LOCATION. COORDINATE EXACT HEIGHT AND LOCATION OF BLOCKING WITH ARCHITECTURAL DRAWINGS. 7 PROVIDE RECEPTACLE IN CABINET ABOVE RANGE FOR MICROWAVE. 8 UDB PANEL TO BE SUTTLE SOLUTIONS 47' SOHO ACCESS ENCLOSURE. PROVIDE DUPLEX 12OV-20A RECEPTACLE INSIDE PANEL FOR EQUIPMENT. ADD TO CIRCUIT #5. CATALOG #SAE-42DDCNY. 1k1/ W®®LPE CST ARCRITECTUREjER61NEERIN6l6EWATIAL 7635 Interactive Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 F E u 110 u U J J Q Issuances: Rey DaCRI"M More 0 Issued For Building 2 Review 10/05/18 1 Issued For Building 2 Permit 05/01/19 2 ASI #10 09/11/19 Prom. No.: 074904 Date: 10/05/18 A Sheet Name: ELECTRICAL ENLARGED PLANS Subject to compliance with all regulations at State and meal Codes City of Cannel (} �Vrtt�\9w1�1jpA� DATE: 10/31/19 E2=401