HomeMy WebLinkAboutElectrical E1.1ABBREVIATIONS A AMRAMPERES ADA AMERICANS WITH DISABILITIES ACT AFC ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AEG ABOVE FINISHED GRADE ANSI AMERICAN NAT'L STANDARDS INSTITUTE ARCH ARCHITECT, ARCHITECTURAL AUX AUXILIARY AWG AMERICANWIREGAUGE AN AUDIOVISUAL BAS BUILDING AUTOMATION SYSTEM ENS BREAKER BLDG BUILDING BMS BUILDING MANAGEMENT SYSTEM C CONDUIT CAW CABLE TELEVISION SYSTEM CIB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CFM CUBIC FEET PER MINUTE OCT CIRCUIT CLG CEILING CT CURRENTTRANSFORMER CW COLD WATER D DEEP,DEPTH Di DIGITAL ALARM COMMUNICATING TRAIN SMITTER all DECIBEL DOC DIRECT DIGITAL CONTROL 6 DELTA CIA DIAMETER DISC DISCONNECT ON DOWN DWG DRAWING EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ETR EXISTING TO REMAIN EMT ELECTRICAL METALLIC TUBING EWC ELECTRICAL WATER COOLER EXIT EXHAUST EX, EXIST EXISTING FA FIREALARM FACE FIRE ALARM CONTROL PANEL FARA FIRE ALARM REMOTE ANNUNCIATOR FLA FULL LOAD AMPS FPC FIRE PROTECTION CONTRACTOR FT FOOT FEET GGRD GROUND GC GENERAL CONTRACTOR GFI, GFCI GROUND FAULT INTERRUPTER HID HIGH INTENSITY DISCHARGE HTR HEATER WAG HEATING,VENTILATING&AC IBC INTERNATIONAL BUILDING CODE IN INCH, INCHES KVA KILOVOLT -AMPS KW KILOWATTS KWH KILOWATT-HOUR L LENGTH LED LIGHT EMITTING DIODE URA LOCKED ROTOR AMPS LTG LIGHTING MAX MAXIMUM MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MECH MECHANICAL MH METALHALIDE MIN MINIMUM MOCP MAXIMUM OVER CURRENT PROTECTION MUA MAKE UP AIR MTD MOUNTED WA NOTAPPMCABLE N.C. NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEW NATIONAL ELECTRICAL MFR'S ASSOC. NFPA NATIONAL FIRE PROTECTION ASSOC. NIC NOT IN CONTRACT N.O. NORMALLY OPEN NTS NOT TO SCALE OC ON CENTER ON OVERHEAD OSHA OCCUPATIONAL SAFETY&HEALTH ADMIN. P POLE PB PUSH BUTTON PC PLUMBINGCONTRACI`M PF POWERFACTOR PH PHASE PVC POLYVINYL CHLORIDE RCP REFLECTED CEILING PLAN REV REVISION REX REMOVE EXISTING RGS RIGID GALVANIZED STEEL RLA RUNNING LOAD AMPS RM ROOM RR REMOVE AND RELOCATE RTU ROOF TOP UNIT SE SERVICE ENTRANCE SF SQUARE FEET, SQUARE FOOT TIC TIMECLOCK THEM THROUGH TRANS TRANSFORMER TYP TYPICAL UG UNDERGROUND ILL UNDERWRITERS LABORATORIES, INC. UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTED POWER SUPPLY VA VOLT-AMPERE W WATT, WIDTH WI WITH WP WEATHERPROOF XFMR TRANSFORMER Y WYE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 10/31/19 ELECTRICAL SYMBOLS TECHNOLOGY SYMBOLS ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS 1,35 HOMERUN TO PANEL" A", CIRCUIT #1,3,5(VIA20A-i P CIRCUIT BREAKERS(, HOMERUN TO EQUIPMENT INDICATED. REFER TO PLANS AND A TWO#12 CONOUCTORS(MINIMUM SIZE(, UON. A GROUNDING CONDUCTOR SPECIFICATIONS FOR ALL REQUIREMENTS. RHN I RF PROVIDED IN Al 1 CnNDI IRR PETER TD.CPFCIFICATIDNF FOR CIRCUITRY TURNING UP 96 PAN ELBOARD - 2WY112TV304 W II PANELBOARD-4WY127/V304W ® DRY TYPE TRANSFORMER REFER TO PLANS FOR SIZFNOLTAGE. OJ 41 JUNCTION BOX- CEILING OR WALL MOUNTED. Lp DISCONNECT SWITCH UNFUSED:"AS"- INDICATES SWITCH SIZE (AMPS). DISCONNECTSWITCH FUSED: "AS" -INDICATES SWITCH SIZE (AMPS). "AP - INDICATES FUSE SIZE (AMPS). COMBINATION MOTOR STARTERDISCONNECT SWITCH C MOTOR IIT� DUPLEX RECEPTACLE- 125V, 23A MOUNTED AT I T ME UNLESS 1( OTHERWISENOTED. CONTROLLED DUPLEX RECEPTACLE-125V, 20A MOUNTED AT W AFF UNLESS OTHERWISE NOTED. R GFCI DUPLEX- 125V, 20A MOUNTED AT I8"AFF UNLESS OTHERWISE NO DUPLEX RECEPTACLE PROTECTED VIA GFCI BREAKER, PROVIDE LABELING AS REQUIRED BY NEC-125V, 20A MOUNTED AT 18"AFF UNLESS OTHERWISE NOTED. DUPLEXABOVE CW NTER-12TI MA MOUNTEDAT T ABOVE COUNT UNLESS OTHERWISE NOTED. CONTROLLED DUPLEX RECEPTACLE ABOVE COUNTER-12/,20A MOUNTEDAT 8" ABOVE COUNTER UNLESS OTHERWISE NOTED. GFCI DUPLEX ABOVE COUNTER-125V 20A MOUNTED AT 8- ABOVE Q 11 COUNTER UNLESS OTHERWISE NOTED. A DUPLEX MOVE COUNTER PROTECTED VIA GFCI BREAKER, PROVIDE LABELING AS REQUIRED BY NEC -125V, 20A, MOUNTED AT 8" ABOVE COUNTER UNLESS OTHERWISE NOTED. DOUBLE DUPLEX RECEPTACLE-125V, 20A MOUNTEDAT 1T AFF UNLES OTHERWISENOTED. SPECIAL PURPOSE RECEPTACLE, TYPE AND MOUNTING AS INDICATED ON THE DRAWINGS. 0 DUPLEX RECEPTACLE- 125V, MX MOUNTED IN CEILING. ® DUPLEXRECEPTACLE- 125V, 23A MOUNTED IN CEILING. ® DUPLEX RECEPTACLE- 125V, 20A MOUNTED IN FLOOR BOX. ® DOUBLEDUPLEXRECEPTACLE- 125V, 20A MOUNTED IN FLOOR BOX. RNCOMBINATION DUPLEX RECEPTACLE AND VOICEDATA OUTLET MOUNTED IN FLOOR BOX. ®` FIRE RATED POKE -THROUGH DEVICE DUPLEX RECEPTACLE-125V, 20A. .® COMBINATION DUPLEX RECEPTACLE AND VOICEDATA POKE -THROUGH DEVICE DUPLEX RECEPTACLE. RANGE RECEPTACLE, REFER TO PLANS FOR TYPE AND AMPERAGE. Q POWER POLE, REFER TO PLANS FOR TYPE AND AMPERAGE. P T CEILING MOUNTED POWERICOMMUNICATIONS FURNITURE FEED. P T WALL MOUNTED POWERICOMMUNICATIONS FURNITURE FEED. EDT POKE-THRU POWERCOMMUNICATIONS FURNITURE FEED. SWITCH- SINGLE POLE TOGGLE TYPE - 1201277V, 20A, 1-HP RATED, MW NTEDAT 48" AFF UNLESS OTHERWISE NOTED. "3" INDICATES THREE WAY SWITCH W INDICATES FOUR WAY SWITCH "C" INDICATES SWITCH MOUNTED S" ABOVE COUNTER "a" INDICATES SWITCHED FIXTURE CONTROL "OS" INDICATES DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH "D INDICATES DIMMER SWITCH- WATTAGE AS INDICATED ON PANEL SCHEDUfE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NETURALCONDUCTOR ER ED. S ® OCCUPANCY SENSOR- DUAL TECHNOLOGY, CEILING MOUNTED © PHOTOCELL SENSOR- DUAL TECHNOLOGY, CEILING MOUNTED �13 LIGHT FIXTURE: -9 INDICATES FIXTURE TYPE,-13- INDICATES CIRCUIT a NUMBER, 'air INDICATES SWITCH CONTROL REFER TO LUMINAIRE A SCHEDULE FOR DESCRIPTION. EllIllidNi- LIGHTING FIXTURE WIRED TO EMERGENCY ANDIOR NIGHT LIGHTING CU. ILLUMINATED "EXIT"SIGN, WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. ILLUMINATED "EXIT"SIGN, CEILING MOUNTEDSUSPENDED. PROVIDE -. DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. leyILLUMINATED "EXIT" SIGN, DUAL HEADS, WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. ILLUMINATED"EXIT"SIGN, DUAL HEADS, CEILING MOUNTEDSUSPENDED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. GA REMOTE EMERGENCY WEATHERPROOF LIGHTING HEAD SUPPLIED FROM REMOTE BATTERY UNIT. Q�ip I_I EMERGENCY LIGHTING BATTERY UNIT WITH HEADS AS INDICATED, DCD7 CEILING ORWALL MOUNTED. ® TIME CLOCK- REFER TO PLANS FOR SPECIFICATIONS. 6 LCP LIGHTING CONTROL PANEL- REFER TO PLANS FOR SPECIFICATIONS. 8 DOORBELL- REFER TO PLANS FOR SPECIFICATIONS. Q DOOR BELL PUSHBUTTON- REFER TO PLANS FOR SPECIFICATIONS. THERMOSTAT- PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 314" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. HVAC UNIT MOUNTED LIGHTIRECEPTAQE //'vuu Vda P JUNCTION BOX AND DISCONNECT SWITCH FOR SIGNAGE INFLOORMNDERFLOOR C W DUITAJIRE CIRCUITRY TURNING UP TELEPHONE FIRE RATED PLYWOOD BACKBOARD - SIZE INDICATED ON PLOD. JUNCTIONBOX CEILING OR WALL MOUNTED. ® COMBINATIONDUPMXRECEPTACMMDVOICMATAOUTLET MOUNTED IN FLOOR BOX. COMBINATION DUPLEX RECEPTACLE AND VOICEDATA POKE -THROUGH DEVICE DUPLEX RECEPTACLE. CEILING MOUNTED POWERICOMMUNICATIONS FURNITURE FEED. WALL MOUNTED POWER)COMMUNICATIONS FURNITURE FEED. PMT® POKE-THRU POWERICOMMUNICATIONS FURNITURE FEED. 0 COMBINATION VOICEDATA OUTLET- MOUNTED AT W AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 314" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "+51" INDICATES WALL MOUNTED AT W AFF, "C" INDICATES MOUNTED 8' ABOVE COUNTER. 0 DATA OUTLET- MOUNTED AT 1 T AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 39" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "+54" INDICATES WALL MOUNTED AT 51" AFF, "C" INDICATES MOUNTED S" ABOVE COUNTER. - VOICE OUTLET -MOUNTED AT IS"AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3N" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "+54" INDICATES WALL MOUNTED AT 51" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER. TV OUTLET -MOUNTED AT I8"AFF UNLESS OTHERWISE NOTED. PROVIDE 4 SINGLE GANG BOX WITH PLASTER RING AND 314"CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "+54" INDICATES WALL MOUNTED AT 54" AFF "C" INDICATES MOUNTED 8" ABOVE COUNTER. 0� SECURITY CAMERA- PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 314" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. ® WIRELESS ACCESS POINT ® KEYPAD ® GLASS BREAK ® DOOR CONTACT ® MOTION SENSOR © ELECTRIC STRIKE ® MAGNETICDCORLOCK ELECTRICAL SPECIFICATIONS DIVISION 26 - ELECTRICAL I. GENERAL PROVISIONS A. GENERAL CONDITIONS CODES & STANDARDS I. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (Al AND ANY OF THE OWNER'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. 2. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AA FOR ADDITIONAL REQUIREMENTS REGARDING' SAFETY COORDINATION & COOPERATION WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS,STORAGE, ADJUSTMENTS, CLEANING, ETC. 3. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, SFATE AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL THE OWNER REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. 4. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REWIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REWIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. 5. ALL EQUIPMENT AND MATERIALS USED SHALL BE NEW AND ILL LISTED FOR THE APPLICATION, AND SHALL BEAR AN APPROPRIATE ILL LABEL. B. SCOPE OF WORK 1. THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH IS APART OF THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS MOOS REQUIRED BY SIMILAR NiIANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF ASIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE OWNER COMPLETE, CODE APPROVED AND OPERATIONAL ELECTRICAL SYSTEM. 2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH ALL TRADES' WOW SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER BEFORE WORK IS COMMENCED. 3. CONTRACTORS SHALL BE HERD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE REWIREDAND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO THE CONTRACTOR BY REASON OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF PINY ERROR ON HIS PART. 4. ALL EXISTING UTILITY AND ELECTRICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE OWNER. 5. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. ALL CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS, AND WALLS SHALL BE FIRESTOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS, AND WALLS PENETRATED. 6. TEMPORARY ELECTRICAL SERVICE, LIGHT ING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. 7. TEMPERATURE AND INTERLOCK CONTROL COMPONENTS AND ALL RELATED WIRING AND CONDUIT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 8. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR MATERIALS AND MISCELLANEOUS EXPENSES REQUIRED FOR ALL REQUIRED ELECTRICAL DEMOLITION OF THE EXISTING AREAS BEING RENOVATED. a. THE DEMOLITION SHALL CONSIST OF THE COMPLETE REMOVAL(PROPERLY DISPOSED OFF SITE UNLESS OTHERWISE NOTED) OF ALL ELECTRICAL EQUIPMENT, WIRING, CONDUIT, MATERIALS, ETC. NOT REQUIRED IN THE FINAL DESIGN AND INSTALLATION OF THE EIEC Mill SYSTEMS FOR THE NEW RENOVATED AREAS. b. ALL UNDERGROUND SERVICES NOT BEING REUSED SHALL BE CAPPED BELOW THE FLOOR, WIRING REMOVED, AND FLOOR PENETRATIONS REPAIRED TO MATCH ADJACENT SURFACES. a. ALL ABOVE GROUND CIRCUITS SHALL BE REMOVED BACK TO THE SOURCE UNLESS INDICATED OTHERWISE. d. COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL DOCUMENTS, THE ARCHITECT, AND THE OWNER'S GENERAL REQUIREMENTS. 9. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND OWNER. WHERE AN EQUIPMENT MANUFACTURER HASA WARRANTYTHAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALLAPPLY TO THIS PROJECT. C. DOCUMENTS 1. THE DRAWINGS ARE DIAGRAMMATIC; ALLWORK SHALL BE PERFORMED AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO A W ITIONAL COST TO THE OWNER. 2. ANY INCIDENTAL ITEMS OR LABOR, ENC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS SHALL BE INCLUDING IN BID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOTH. 4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS, OR DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS AND THE SCALE OF SAME, OR BETWEEN THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS, SUCH ERRORS SHALL BE REFERRED TO THE OWNER FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE. 5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL AND MUST BE SUBMITTED AS SPECIFIED IN THE ARCHITECTURAL DOCUMENTS. 6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS ASSET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. D. COORDINATION 1. CONTRACTORSHALLLOCATE IDENTIFY AND PROTECT MY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONALAND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORT( TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAD BY THE CONTRACTOR CAUSING THE DAMAGE. 2. EACH CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORT( CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB TRADES PERSONNEL. ALL PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE OWNER BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAD BY THE CONTRACTOR CAUSING THE DAMAGE. 3. IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AT SUCH TIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE OPERATIONS OF THE SPACE, ADJACENT SPACES, OR FACILITY. A WORK SCHEDUILE SHALL BE ARRANGED WITH THE OWNER, INCLUDING PREMIUM TIME WORK TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE TO THE OWNER'S OPERATIONS. E. METHODS I. EXCAVATIONS SHALL BE MADE IN OPEN TRENCHES. FLOORS SHALL BE SAW CUT. CONDUIT SHALL BE LAID ON AN APPROPRIATELY GRADED T BED OF CLEAN AND DRY SAND. ENGINEERED FILL SHALL BE USED TO BACKFILL TO 6" ABOVE THE CONDUIT. BACKFHL THE REMAINDER OF THE TRENCH UTILIZING THE EXCAVATED MATERIAL IF APPROVED BY THE ARCHITECT OR THE OWNER. IF THE EXCAVATED MATERIALS ARE NOT ACCEPTABLE, ENGINEERED FILL ACCEPTABLE TO THE ARCHITECT SHALL BE UTILIZED TO BACKFILL THE REMAINDER OF THE TRENCH. BACKFILLSHALL BE ACCOMPLISHED IN 9" LIFTS WITH ALL LIFTS COMPACTED TO 95%PROCTOR. PATCH FLOOR TO MATCH EXISTING. 2. EQUIPMENT, CONDUIT, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER PIPING, OTHER CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND STRUCTURAL ENGINEER. 3. ALL ROOF PENETRATIONS, FLASHINGS AND COUNTER FLASHINGS SHALL BE PERFORMED BY THE OWNER'S ROOFING CONTRACTOR AT THE REQUESTING CONTRACTORS COS I. F. SUBMITTALS 1. SHOP DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT OF ALL EQUIPMENT AND ACCESSORIES PROVIDED FOR THE PROJECT WHETHER SPECIFIED HERE -IN OR ON THEDRAWINGS. REVIEW OF THE SHOP DRAWINGS SHALL BE FOR GENERAL DESIGN CONCEPT AND ADHERENCE WITH THE SPECIFICATIONS. QUANTITY OF SHOP DRAWINGS SUBMITTED SHALL BE AS SPECIFIED BY THE ARCHITECT. SHOP DRAWINGS SHALL BE PREPARED BY THE CONTRACTOR SHOWING LOCATIONS AND MEASUREMENTS FROM COLUMNS OF ALL CONCEALED AND EXPOSED PIPING, DUCTWORK( CONDUIT, EQUIPMENT, ACCESSORIES, ETC., AND SUBMITTED PRIOR TO INSTALLATION. THE OWNER MAY MAKE REPRODUCIBLE COPIES OF THEIR DRAWINGS AVAILABLE FOR USE IN PREPARATION OF SHOP DRAWINGS, HOWEVER THE OWNER SHALL NOT BE HELD RESPONSIBLE FOR NOT CONFIRMING ALL INFORMATION ON THE DRAWINGS PRIOR TO FABRICATION ANDIOR INSTALLATION. 2. PROJECT RECORD DOCUMENTS- MAINTAIN AT THE JOBSITE ONE COPY OF ALL CONTRACT DOCUMENTS CLEARLY MARKED M "PROECT RECORD COPY°. THESE DRAWINGS ARE TO BE MAINTAINED IN GOOD CONDITION, UPDATED DAILY FOR CHANGES ENCOUNTERED AND AVAILABLE AT ALL TIMES FOR INSPECTION BY THE OWNER. DONOTUSEFORFIELUCONSTRUCNONI PROJECT RECORD DOCUMENTS ARE TO BE KEPT CURRENT WITH EXACT DIMENSIONS OF ALL WORK, EQUIPMENT DISTRIBUTION CONDUIT, CIRCUITS, ETC. MARK ALL INFORMATION IN RED LINES AND NOTES BOAS TO BE EASILY IDENTIFIED FROM THE BASE DRAWING. UPON COMPLETION OF THE WORK(, ONE SET OF THESE DOCUMENTS SHALL BE TURNED OVER TO THE OWNER AS ONE QUALIFICATION FOR FINAL PAYMENT. 3. THREE COMPLETE SETS OF AS -BUILT DOCUMENTATION SHALL BE PROVIDED. IT SHALL INCLUDE, BUT NOT BE LIMITED TO ACCURATE PLAN DRAWINGS, WIRING DIAGRAMS AND OPERATION AND MAINTENANCE MANUALS. 4. SUBMIT OVERCURRENT DEVICE COORDINATION STUDY INCLUDING EQUIPMENT EVALUATION REPORTS, ONE LINE DIAGRAM, PROTECTIVE DEVICE COORDINATION STUDY AND TIME -CURRENT COORDINATION CURVES. STUDY ELECTRICAL DISTRIBUTION SYSTEM FROM NORMAL AND ALTERNATE POWER SOURCES. THE STUDY SHALL COMPLY WITH IEEE 399 FOR GENERAL STUDY REQUIREMENTS. II. PRODUCTS A CONDUIT 1. CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL WHERE EXPOSED AND SUBJECT TO DAMAGE 8-0" AFF AND BELOW AND IN WE LOCATIONS WHERE INDICATED ON THE DRAWINGS. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC AND SHALL BE CONCRETE ENCASED ST MINIMUM) WHERE INDICATED ON THE DRAWINGS. A TRANSITION SHALL BE MADE TO HEAVY WALL RIGID GALVANIZED STEEL BEFORE PVC CONDUITS PENETRATE THE FLOOR SLAB. INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT). METAL CLAD (MC) CABLE MAY BE USED IF APPROVED BY THE OWNER, AND INSTALLED IN LOCATIONS PERMITTED BY CODE. 2, FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOX TO INDIVIDUAL RECESSED LIGHT FIXTURES, AND FOR FINAL CONNECTIONS TO MOTORS AND OTHER DEVICES SUBJECT TO VIBRATION. B. CONDUIT FITTINGSMDBOXES 1. INTERIOR OUTLET BOXES SHALL BE STANDARD GALVANIZED SHEET STEEL TYPE, NOT LESS THAN 14 GAUGE IN THICKNESS, WITH KNOCKOUT OPENINGS, EXTENSIONS, PLASTER RINGS AND COVER PLATES TO ACCOMMODATE THE DEVICES INSF&MD. COVER PLATES SHALL BE SMOOTH PLASTIC TO MATCH DEVICE COLOR. USE STEEL PLATES WITH ROUNDED CORNERS FOR SURFACE BOXES. OUTDOOR (WET LOCATION) OUTLET BOXES SHALL BE CAST ALUMINUM TYPE WITH DEVICE COVERS TO SUIT. 2. OUTLET BOXES SHALL NOT BE LESS THAN 4 INCHES SQUARE 1-112INCHES DEEP. 3. COUPLINGS AND CONNECTORS FOR EMT SHALL BE DIE CAST ZINC OR STEEL BUSHING SHALL BE GROUNDING TYPE WITH INSULATING PLASTIC INSERT. 4. FLOOR BOXES SHALL BE FLUSH SERVICE TYPE., RECTANGULAR CAST METAL CONSTRUCTION GANGABLE ADJUSTABLE WITH BRASS (ALUMINUM) COVER AND TRIMIFLANGE AS REWIRED. COVER TYPE SHALL BE AS INDICATED ON LEGEND. C. WIRE AND CABLE 1. CONDUCTORS FOR POWER AND LIGHTING SHALL BE NEW 600-VOLT, 90-C, TYPE XHHW, THHW, OR THWN INSULATION, MINIMUM SIZE 912-AWG EXCEPT FOR CONTROL WIRING WHICH MAY BE #14-AWG. OTHER SIZES SHALL BE AS NOTED ON THE DRAWINGS. CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE APPROVED BYTHEOWNER. 2. BRANCH CIRCUIT RUNS EXCEEDING 100 FEET IN TOTAL LENGTH FROM THE PANELBOARD TO THE LAST DEVICE, SHALL BE #10-AWG CONDUCTORS UNLESS OTHERWISENOTED. 3. COMPRESSION TYPE LUGS AND CONNECTORS SHALL BE USED FOR ALL TERMINATIONS AND SPLICES. 4. ALL LOW VOLTAGE COMMUNICATIONS, FIRE ALARM, DATA, SECURITY, TELEPHONE AND ALL OTHER MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CEILING SHALL BE PLENUM RATED. D. WIRING DEVICES 1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 520R, RATED FOR 20 AMPS, 125 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 2. CONTROLLED RECEPTACLES SHALL BE PROVIDED WITH IDENTIFIABLE MARKINGS. 3. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 1M127 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 4. DIMMERS SHALL BE LUTRON"NOVA T-STAR" SERIES, OF A RATING, VOLTAGE AND WATTAGE SUITABLE FOR LOAD SERVED. 5. COLORS OF DEVICES SHALL BE SELECTED BY ARCHITECT. 6. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL PASS &SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC. E. LIGHTING AND RECEPTACLE PANELBOARDS I. BRANCH CIRCUIT PANELBOARDS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR, ALL IN ASURFACE OR FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 1201208V, AND 18,000 AMPS SYMMETRICAL FOR 2771480V APPLICATION UNLESS NOTED OTHERWISE. 2. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE; WITH MOLDED PLASTIC CASE 1, 2, OR 3 POLE AS INDICATED, QUICK -MAKE, QUICK -BREAK; AND THERMAL -MAGNETIC TRIP DEVICE. 3. ALL BREAKERS FEEDING HVAC EQUIPMENT SHALL BE HACK RATED, UNLESS OTHERWISENOTED. 4. ALL EQUIPMENT RATED 100A OR LESS SHALL HAVE 60 DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED OVER 100A SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. 5. INDIVIDUAL SINGLE POLE CIRCUIT BREAKERS, WITH IDENTIFIEDTIES, OR 213 POLE BREAKERS SHALL BE PROVIDED FOR EACH UNGROUNDED CONDUCTOR IN ALL MULTI -WIRE BRANCH CIRCUITS. 6. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, SIEMENS, AND EATON. F. SAFETY SWITCHES AND MOTOR STARTERS 1. SAFETY SWITCHES SHALL BE FUSIBLE OR NON- FUSIBLE AS INDICATED ON THE DRAWINGS. SWITCHES SHALL BE QUICK -MAKE, QUICK -BREAK, HEAVY DUTY VISIBLE BLADE TYPE. ENCLOSURES SHALL BE NEMA 1 TYPE UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FUSES SHALL BE DUAL ELEMENT - TIME DELAY TYPE. 2. MAGNETIC MOTOR STARTERS SHALL BE COMBINATION TYPE WITH THERMAL OVERLOAD, INTEGRAL FUSED SAFETY SWITCH, H-0 A SELECTOR SWITCH, CONTROL TRANSFORMER, RUNNING PILOT LIGHT, NEMA TYPE 1 ENCLOSURE, AND (2) NORMALLY OPEN AND (2) NORMALLY CLOSED AUXILIARY CONTACTS. 3. ALL MOTORS OVER 118 HE SHALL BE PROVIDED WITH THERMAL OVERLOAD PROTECTION. OVERLOAD PROTECTION SHALL BE PROVIDED INTEGRAL WITH THE MOTOR WINDINGS ANDOR MOTOR CONTROLLER (PROVIDED BY OTHERS) UNLESS OTHERWISE INDICATED ON DRAWINGS. 4. ALL EQUIPMENT RATED 100A OR LESS SHALL HAVE 60 DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED OVER I ORA SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. G. LUMINAIRES AND LAMPS t. ALL LUMINAIRES SHALL BE SPECIFIED ON THE LUMINAIRE SCHEDULE. 2. BALLASTS SHALL BE INSTANT START, ELECTRONIC TYPE, CLASS P, "A"SOUND RATING AND MAXIMUM HARMONIC CONTENT OF 10%. DIMMING BALLASTS SHALL BE 3WIRE TYPE, WITH DIMMING CAPABILITY TO 10%OF RATED FULL OUTPUT. 3. RECESSED LUMINAIRES WITH INCANDESCENT LAMPS SHALL BE PROVIDED WITH THERMAL PROTECTION. 4. FLUORESCENT LAMPS SHALL BE MW K. INCANDESCENT LIMPS SHALL BE I D VOLT. HIGH INTENSITY DISCHARGE LAMPS SHALL BE COATED. 5. EMERGENCY LIGHTING AS INDICATED, SHALL PROVIDE A MINIMUM OF ONE FOOTCANDLE ALONG THE PATH OF EGRESS. EMERGENCY FIXTURE SUPPLIER SHALL PROVIDE FOOTCANDE PRINTOUT TO VERIFY EMERGENCY LIGHT LEVELS. 6. ALL FIXTURE I BALLAST I LAMP COMBINATIONS SHALL BE ENERGY SAVING TYPE. III, EXECUTION A GENERALMISCELLANEOUS 1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT SMALLER THAN 314" SHALL NOT BE USED FOR PINY CIRCUIT HOMERUNS. 2. RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES SHALL BE FILLED WITH AN APPROVED MATERIAL IN ACCORDANCE WITH ARTICLE 300.7 OF THE NATIONAL ELECTRICAL CODE. 3. HANGERS,SUPPORTS, OR FASTENINGS SHALL BE PROVIDED AT EACH ELBOW, AT THE ENDS OF STRAIGHT RUNS TERMINATING AT BOXES OR CABINETS, AND AT INTERMEDIATE POINTS AS REQUIRED BY CODE. CONDUITS OR BOXES SHALL NOT BE SUPPORTED BY CEILING SUPPORT WIRES OR OTHER CEILING SUPPORTING HARDWARE. 4. ACCESS PANELS SHALL BE PROVIDED FOR ALL JUNCTION BOXES AND PULL BOXES INSTALLED MOVE DRYWALL CEILINGS, COORDINATE SIZE AND LOCATION WITH ARCHITECT. 5. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH ARTICLE 410.30 OF THE NATIONAL ELECTRICAL CODE, OR ANY LOCAL CODES WHICH MY APPLY. 6. PROVIDE PERMANENT NAMEPLATES WITH DESIGNATIONS FOR PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS. 7. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT PANELBOARDS. PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16. 8. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS. 9. THE ELECTRICAL CONTRACTOR SHALL BALANCE PANELBOARD LOADING TO WITHIN 10%ON EACH PHASE BASED ON INSTALLED CONDITIONS. LOAD BALANCING CIRCUIT CHANGES SHALL BE PERFORMED OUTSIDE THE NORMAL OCCUPANCY WORKING SCHEDULE AND AT A TIME DIRECTED BY LANDLORD. 10. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHING -IN, AT NO A W ITIONAL COST TO THE OWNER. 11. CONTACT ELECTRIC POWER COMPANY AND MAKE NECESSARY ARRANGEMENTS FOR ELECTRIC SERVICE. 12. CONTACT TELEPHONE COMPANY AND MAKE NECESSARY ARRANGEMENTS FOR TEMPHONESERVICE. 13. AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY CONDITION, FOLLOWING OWNER'S INSTRUCTION IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES AND DISPOSING OF DEBRIS. 14. ALL SERVICE EQUIPMENT SHALL BE IDENTIFIED AS BEING SUITABLE FOR USE AS SERVICE EQUIPMENT. SERVICE EQUIPMENT SHALL BE FIELD MARKED WITH THE MAXIMUM AVAILABLE FAULT CURRENT AND THE DATE THE CALCULATION WAS PERFORMED. FIELD MARKING SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE INSTALLATION ENVIRONMENT. 15. PROVIDE COMPUTER -BASED, OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDIES TO DETERMINE OVERCURRENT PROTECTIVE DEVICES AND TO DETERMINER OVERCURRENT PROTECTIVE DEVICE BE FOR SELECTIVE TRIPPING. THE OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY REPORT SHALL BE SIGNED, DATE AND SEALED BY A PROFESSIONAL ENGINEER. a. FIELD ADJUST RELAY AND PROTECTIVE SETTINGS ACCORDING TO THE RECOMMENDED SETTINGS PROVIDED BY THE COORDINATION STUDY. b. MAKE MODIFICATIONS TO EQUIPMENT AS REQUIRED TO ACCOMPMSH COMPLIANCE WITH PROTECTIVE DEVICE COORDINATION STUDIES. B. GROUNDING 1. GROUND ALL CONDUITS,CABINETS, MOTORS, PANELS, AND OTHER EXPOSED NON -CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 250, 2. BOND METAL WATER PIPING AND OTHER METAL PIPING(INCLUDING GAS PIPING) AND EXPOSED STRUCTURAL METAL IN ACCORDANCE WITH NEC ARTICLE 250. 3. GROUNDING OF THE EIEC Mill SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS. FIRE ALARM NOTES 1. PRINCIPAL OCCUPANCY CLASSIFICATION IS GROUP M. 2. SPACE IS PROVIDED WITH FULL SPRINKLER COVERAGE. 3. OCCUPANT LOAD IS LESS THAN 500. 4. THE LANDLORD DOES NOT REQUIRE ALL TENANTS TO INSTALL A FIRE ALARM SYSTEM MONITORED BY THE LANDLORD SYSTEM. 5. A FIRE ALARM SYSTEM IS NOT REQUIRED. 6. FIRE ALARM SYSTEM INSTALLED OR MODIFIED BY THIS CONTRACTOR IS TO BE VERIFIED AND CERTIFIED BY AHJ AT THIS CONTRACTOR'S EXPENSE. 7. SMOKE CONTROL SYSTEMS SHALL BE AUTOMATICALLY ACTIVATED IN RESPONSE TO FIRE UETECTION DEVICES (THIS IS FOR SMOKE EVACUATION SYSTEMS ONLY). 8. SMOKE CONTROL SYSTEMS SHALL BE CAPABLE OF BEING ACTIVATED FROM THE FIREFIGHTER SMOKE CONTROL STATION (FCSC) BY SWITCHES CLEARLY MARKED TO IDENTIFY LOCATION AND FUNCTION (THIS IS FOR SMOKE EVACUATION SYSTEMS ONLY). CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288. 0681 F :: 317. 288. 0753 Wn BY: JTK CHECKED BY: EJR *T/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 8717954 tesengineedng.com B/1/19 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE E CLUEAVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOM OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCH TECNRE. © Cov11aw7200CURe4NAxClmcelU.sa I:H7I_[�771�yc[+IC�7lIl 10460 N MICHIGAN RD CARMEL, IN 46032 ELECTRICAL SPECIFICATIONS AND LEGEND PROJECT NUMBER: 190197 E I.I