HomeMy WebLinkAboutMechanical M1.0OUTLINE ON ROD RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Camel (� yVT�tanrMDA�L DATE: \ 10/31/19 1 MECHANICAL PLAN Mica SCALE varmv-0" GENERAL SHEET NOTES Is 1. EXISTIWORK. THECO TRACT RSHALL FIE DVERIFYIS BASED H LIMITEDEXISTINGSNDITIO SFORLDING DRAWINGS AND FIELD . WORN.THECONTRACTORSHALL FIELDVERIFYTHEEXISTINGCONDITIONSFUATION THAT CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT IS DESCRIBED IN THE DOCUMENTS. 2. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. 3. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER OISCIPLINES FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION PRIOR TO ANY ISOLATION CONDITIONS.FSYSTEMS, C U R R A N 4. PRIORTOANV ISOLATIOU 6SYSTEMS,SHUTDOWNS OR DEMOLITION THE CONTRACTOR SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACULTIES ENGNEENNUMAINTENANCE PERSONNEL OF WORK TO BE PERFORMED SO AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES. 5. PROTECT EQUIPMENT, FIXTURES, PIPING, DUCTWORIC ETC. INDICATED TO REMAIN AGAINST DAMAGE A R C H I T E C T U R E AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY THE ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION WRING SELECTIVE DEMOLITION AND THEN 5719 LAWTON LOOP E. DR. #212 CLEANED AND REINSTALLED IN THEIR ORIGINAL LOCATIONS. INDIANAPOLIS, IN 46216 6. WHERE PIPE, DUCTWORK, INSULATION, FIXTURES OR EQUIPMENT TO REMAIN IS DAMAGED OR O :: 317. 288. 0681 DISTURBED, REMOVE THE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY AND IF :: 317 . 288 . 0753 QUALITY. WHERE IDENTICAL MATERIALS ARE UNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE EQUALS OR SURPASSES THAT OF THE EXISTING MATERIALS. 7. MAINTAIN AND RESTORE, IF INTERRUPTED BY DEMOLITION OR IN THE PATH OF NEW CONSTRUCTION, ALL UTILITIES PASSING THROUGH AND SERVING OUTSIDE OF DEMOLITION AREA. 8. MECHANICAL SYSTEMS INSTALLATIONS MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS DESIGNATED AS EITHER FIRE RATED OR 'SMOKE TIGHT. PROVIDE CODE REQUIRED THROUGH - PENETRATION FIRESTOP SYSTEM AT RATED OR SMOKE TIGHT ASSEMBLIES WHERE FIRE DAMPERS ARE NOT REQUIRED. COORDINATE WIARCHITECTURAL PLANS AND GENERAL CONTRACTOR. 9. SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED PER NFPA 70. 10. UNITED ABOVE CEILING CLEARANCES EXIST. COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORT( WITH ALL DUCTWORK( SPRINKLERS, LIGHT FIXTURES, AND OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE. DRAWN BY: STK *T/E/S CHECKD BY: KOH 11. ALLROOF PENETRATIONS, RATTHIS C NTRAC OR'S E GSHALL 00RDINORMED BYPENETR TIONS AROVED ROOFING CONTRACTORAT THIS HIND ANCFOU'S EXPENSE. COORDINATE ROOF A LANDLORD AND O PENETRATIONS AND ROOFTOP EQUIPMENT LOCATIONS WITH LANDLORD AND GENERAL CONTRACTOR. 12. NOTHINGS PERMITTEDTOBEATTACHEDTQ SUSPENDEDFROM, OR PENETRATETHE ROOF DECK. CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST ORTHE STRUCTURAL E NGINE ERING STEEL WHICH EXISTS ABOVE THE SPACE. 13. COORDINATE FINAL ROOFTOP UNIT LOCATIONS WITH LANDLORDS STRUCTURAL ENGINEER. ROOFTOP 25760 First Street UNITS AND MAKE-UP AIR UNIT TO BE LOCATED WITHIN STRUCTURAL BAY. PROVIDE 10' CLEARANCE FROM Cleveland, OH 44145 UNIT OUTSIDE AIR INTAKE TO ANY EXHAUSTNENTS ON ROOF. P 440 8712410 14. GENERAL CONTRACTOR TO LABEL ALL ROOFTOP EQUIPMENT WITH TENANT NAME, SPACE NUMBER AND F 440 8717954 EQUIPMENT IDENTIFICATION (RTU-1, ETC.), PER MALL SPECIFICATIONS AND STANDARDS. tesengineedng.com 15. REFER TO LL CRITERIA MANUAL FOR ADDITIONAL STANDARDS AND REQUIREMENTS. 16. COORDINATE ALL THERMOSTAT AND SENSOR LOCATIONS WITH FURNITURE LAYOUT AND ARCHITECTURAL PLANS. DEVICES ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR MOUNT PER ADA REQUIREMENTS. 17. ALL EXPOSED DUCTWORKTOBE PAINTED. REFER TO ARCHITECTURAL PLANS. 18. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDE ANGLE OF DIVERGENCE OF 15 DEGREE. 19. DUCT SIZES INDICATED REPRESENT EXTERNAL SHEET METAL DIMENSIONS AND INCLUDE ALLOWANCE FOR INTERNAL INSULATION. 20. SUPPLY AIR DUCTWORK NOT LOCATED IN A RETURN AIR PLENUM OR EXPOSED SHALL BE EXTERNALLY INSULATED. ALL OUTSIDE AIR DUCTWORK NOT EXPOSED SHALL BE EXTERNALLY INSULATED. 21. BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED UNLESS NOTED OTHERWISE. 22. PROVIDE ACCESS HATCHES(24"X24") FOR ALL MECHANICAL EQUIPMENT LOCATED ABOVE A HARD CEILING COORDINATE WI ARCHITECTURAL CEILING PLANS. 23. PITCH POCKETS ARE NOT PERMITTED ON THE ROOF FOR CONDENSATE DRAINS, POWER OR CONTROL WIRING. ALL CONNECTIONS ARE TO BE MADE INSIDE THE EQUIPMENT CURB OR THROUGH FEEMANUFACTUREDPIPING CURB. 24. COORDINATE EXACT MOUNTING REQUIREMENTS AND LOCATION OF HOOD WITH HOOD SHOP DRAWINGS AND OWNER REQUIREMENTS. 25. GREASE EXHAUST DUCT ACCESS PANEL CLEANOUT OPENINGS SHALL BE EQUIPPED WITH TIGHT FRTING DOORS (EQUAL TO THE THICKNESS OF THE DUCT)AND SHALL HOLD TIGHTLY CLOSED. 26. CONTRACTOR MUST REPLACE ALL AIR FILTERS IN ROOFTOP UNITS WITH AIR BALANCING AND PRIOR TO FINAL TURNOVER TO TENANT. O SHEET KEYNOTES 1 TRANSITION LINED SUPPLY AND RETURN DUCTS IN RISE TO FULL SIZE OF RTU SUPPLYAND RETURN OPENINGS. CONNECT TO FULL SIZE OF RTU SUPPLY AND RETURN OPENINGS WITH FLEX CONNECTION BELOWROOFDECK. PROVIDE RECTANGULAR ELBOW WITH DOUBLE THICKNESS TURNING VANES IN TRANSITION TO HORIZONTAL REFER TO RTU SECTION DETAIL ON SHEET M0.0 FOR ADDITIONAL INFORMATION. 2 MOUNT THERMOSTAT BANK IN OFFICE ABOVE EQUIPMENTI FIXTURES. MOUNT THERMOSTATS AT 481 3 SMOKE DETECTOR FACTORY MOUNTED IN RETURN SECTION OF RTU. 4 UNDERCUT DOOR BY I".(TYPICAL OF ALL TOILET ROOMS) 5 2v22 OPENING IN TOP OF RE TURN DUCT. 6 ROUTE NOTED SIZE EXHAUST DUCT UP TO ROOF ABOVE AT NOTED LOCATION. PROVIDE AND INSTALL PRE MANUFACTURED ROOF CAP WITH BACK DRAFT DAMPER FOR EXHAUST TERMINATION ABOVE ROOF. 7 WALL MOUNTED TEMPERATURE AVERAGING SENSOR. COORDINATE EXACT LOCATION WITH FURNITURE LAYOUT AND ARCHITECTURAL PLANS. TEMPERATURE SENSOR SHALL BE WIRED BACK TO THERMOSTAT IN OFFICE. INSTALL WITH INSULATED PAD WHERE LOCATED ON EXTERIOR WALLS. 8 BOOT TAP WITH VOLUME DAMPER FROM MAKE UP AIR DUCT MAIN TO FULL SIZE 26'X 17 MAKE UP AIR SUPPLY OUTLETS ON HOOD. BALANCE EACH TO 900 OEM. 9 PROVIDE 1IT X 1IT GREASE EXHAUST DUCT FROM KITCHEN HOOD TO GREASE EXHAUST FAN ON ROOF ABOVE. PROVIDE GREASE CLEANOUTS AT EVER 194-AND AT EVERY CHANGE IN DIRECTION. FOLLOW ALL MANUFACTURER AND LOCAL CODE REQUIREMENTS FOR GREASE EXHAUST SYSTEM. 10 ROUTE NOTED SIZE MAKE UP AIR OUCTWORK FROM MUA-1, TRANSITION TO FULL SIZE OF MUA OUTLET IN VERTICAL. PROVIDE FLEX CONNECTION AT UNIT OUTLET. I,O�S �SS�pO OR 5 c ^ma PROJECT N LOCATION ` H KEY PLAN 8/1/19 THIS DRAWING AND THE IDEAS DESIGNS AND CONCEPTS CONTAINED HEREIN ME THE EXCLUIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOM OR IN PART, WITHOUTTHE WRITTEN CONSENT OF CURRAN ARCHITECTURE. 0 C IWp172019.CLsVANNRCHIFECNR£ ��*i�,lW1:1yG«Cei 11 10460 N MICHIGAN RD CARMEL, IN 46032 MECHANICAL PLAN PROJECT NUMBER: 190197 M 1.0