CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on:September 12, 2019
Project number Release date
409933 09/12/19
Construction type Occupancy classification
Scope of release
II-B A-2, REM
Type of release
Project name
Street address
City County
ARCH ELEC HOOD MECH
PLUM
Standard
Kolache Facory
10460 N Michigan Rd
Suite 110
CARMEL HAMILTON
To: Owner / Architect / Engineer
Curran Architecture
Shawn M Curran AR19600043
5719 Lawton Loop E Dr
Suite 2
Indianapolis IN 46216
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
4G0412AE
14W1104A
14B0700
14B1100HC
14M050709
14M0506
This project has been reviewed under the 2014 Indiana Building Code.
The proposed building, addition, or remodel shall not put the existing building in noncompliance or
into further noncompliance in accordance with 675 IAC 12-4-12.
Required means of egress shall be maintained during construction and demolition, remodeling or
alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5).
Fire resistive construction shall be maintained in accordance with Chapter 7, IBC (675 IAC 13-2.6).
The current code for handicapped accessibility in use in the State of Indiana is Chapter 11 of the
Indiana Building Code (675 IAC 13-2.6) and ICC standard A117.1, 2009 edition (675 IAC 13-2.6).
NOTE: This release includes a Type 1 Hood and Hood Fire Suppression System.
The complete installation of the kitchen exhaust hood and hood suppression system shall be in
accordance with Sections 507 and 509, IMC (675 IAC 18-1.6).
Commercial kitchen hood ventilation system ducts and exhaust equipment shall be designed and
installed in accordance with Section 506, IMC (675 IAC 18-1.6).
NOTE: Grease duct clearances where enclosures are not required, grease duct systems and
exhaust equipment serving a Type I hood shall have a clearance to combustible construction of not
less than 18 inches (457 mm), and shall have a clearance to noncombustible construction and
gypsum wallboard attached to noncombustible structures of not less than 3 inches (76 mm) in
accordance with Section 506.3.6, IMC.
NOTE: A Type I hood shall be installed with a clearance to combustibles of not less than 18 inches
(457 mm) in accordance with Section 507.9, IMC.
NOTE: Exhaust outlets shall be located not less than 10 feet (3048 mm) horizontally from parts of
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
3172880753, scurran@curran-architecture.com
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
AREL
4G03
the same or contiguous buildings, adjacent buildings and adjacent property lines and shall be
located not less than 10 feet (3048 mm) above the adjoining grade level. Exhaust outlets shall be
located not less than 10 feet (3048 mm) horizontally from or not less than 3 feet (914 mm) above air
intake openings into any building in accordance with Section 506.3.13.3, IMC.
NOTE: Duct-to-exhaust fan connections shall be flanged and gasketed at the base of the fan for
vertical discharge fans; shall be flanged, gasketed and bolted to the inlet of the fan for side-inlet
utility fans; and shall be flanged, gasketed and bolted to the inlet and outlet of the fan for in-line fans.
Gasket and sealing materials shall be rated for continuous duty at a temperature of not less
than1500ºF (816ºC) in accordance with Section 506.3.2.3, IMC.
NOTE: Makeup air shall be supplied during the operation of commercial kitchen exhaust systems
that are provided for commercial cooking appliances. The amount of makeup air supplied to the
building from all sources shall be approximately equal to the amount of exhaust air for all exhaust
systems for the building. The makeup air shall not reduce the effectiveness of the exhaust system.
Makeup air shall be provided by gravity or mechanical means or both. Mechanical makeup air
systems shall be automatically controlled to start and operate simultaneously with the exhaust
system. Makeup air intake opening locations shall comply with Section 401.4, IMC, in accordance
with Section 508.1, IMC.
Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from
required compliance with all applicable rules of the commission, even if noncompliant conditions
appear in the plans and specifications that have been filed with the division. The owner is
responsible for correcting any and all areas of noncompliance even if they are discovered
subsequent to the issuing of this design release.
This construction design is a revised release to the release dated: 09/03/2019 (correction of
street address)
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
LARRY DAVIS
CHARLES KIPHART
ONE HAMILTON SQUARE SUITE 138
NOBLESVILLE,IN 46060
BUILDING COMMISSIONER
Fax & e-mail: 3177742559, Chuck.kiphart@hamiltoncounty.in.gov
Director, Division of Fire and Building Safety ldavis2@dhs.in.gov