Loading...
HomeMy WebLinkAbout3313 Room Addition End Truss DesignProject Name: QTREC0611152 Qty: 2 Truss: t1e Customer: Walk - In SID: TID: Date:10 / 18 / 19 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Midwest Manufacturing 5311 Kane Road Eau Claire, WI 54703 (715) 876-5555 midwestmanufacturing.com Typical plate: 1.5x4 3x4= 3x4= 3x4= 1-0-0 1-0-0 4-1 4-14-6-14-10-131 4-0-0 2 2-0-0 3 2-0-0 4 2-0-0 10-0-0 5 2-0-0 6 2-0-0 7 2-0-0 8 4-0-0 20-0-0 9 1 4-0-0 11 2-0-0 12 2-0-0 13 2-0-0 14 2-0-0 15 2-0-0 16 2-0-0 17 4-0-0 20-0-0 910 18 20-0-0 5/12 -5/12 Plates -- Simpson Strong-Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicated by '-18' Code/Design: IRC-2012/TPI-2007 PSF Live Dead Dur Factors TC 20.0 7.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 37.0 Plt 1.15 1.60 1.15 Spacing: 1-04-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 15% Creep (Kcr) = 1.5 OH Soffit Load: 1.0 psf -----------Snow Load Specs----------- ASCE7-10 Ground Snow(Pg) = 30.0 psf Risk Cat: II Terrain Cat: B Roof Exposure: Fully Exposed Thermal Condition: Cold Ventilated(1.1) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: Yes ----------Wind Load Specs---------- ASCE7-10 Wind Speed(V) = 115 mph Risk Cat: II Exposure Cat: B Bldg Dims: L = 0.0 ft B = 0.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 4.2 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: HybridMW -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 SP (ALSC6-2013) #1 BC 2x4 SP (ALSC6-2013) #1 Webs 2x4 SP (ALSC6-2013) #1 Member Forces Summary ...Mem... Ten Comp .CSI. TC 1- 5 44 40 0.05 5- 9 47 40 0.05 BC 1- 9 40 12 0.01 Web 2-11 81 132 0.01 3-12 46 106 0.01 4-13 76 128 0.02 5-14 0 57 0.01 6-15 76 128 0.02 7-16 46 106 0.01 8-17 81 132 0.01 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 9 54 1 20-00-00 Max Horiz = -26 / +26 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [10-00-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 8.0/12 Notes Gable webs are attached with min. 1x3 20 ga.plates. The max.rake overhang = 1/2 the truss spacing. If this truss is exposed to wind loads perpendicular to the plane of the truss, it must be braced according to a standard detail matching the wind criteria shown, or according to the Construction Documents and/or BCSI - B3. Plates designed for Cq at 0.85 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/240 L/999(-0.00) 18- 9 Vert DL L/90 L/999(-0.00) 18- 9 Vert TL L/180 L/999(-0.00) 18- 9 Horz LL 0.75in ( 0.00) @Jt 9 Horz TL 1.25in ( 0.00) @Jt 9 Bracing Data Summary ------------Bracing Data------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Joint Stress Index (JSI): Jnt1(0.52), Jnt2(0.65), Jnt3(0.65), Jnt4(0.65), Jnt5(0.65), Jnt6(0.65), Jnt7(0.65), Jnt8(0.65), Jnt9(0.52), Jnt11(0.65), Jnt12(0.65), Jnt13(0.65), Jnt14(0.65), Jnt15(0.65), Jnt16(0.65), Jnt17(0.65)