HomeMy WebLinkAboutGN010.0- Energy CertificateIECC 2909 Performance Compliance
P ro pe rty
11937 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WE,:
WWC52 (AS DESIGNED)
WATER FRONT AT WEST CLAP 52
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN
HOME BUILDING
GROUP
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,450
$258
$369
$2,077
$1,184
$0
$3,262
Requirements
405.3
Performance -based compliance passes by 6.5%
®
R402.4.12
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
®
402.5
Area -weighted average fenestration U-Factor
40322
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C",Erergy Solutions
As Designed
$1,390
$183
$369
$1,942
$1,161
$0
$3,103
Air sealing is 4.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 5D Pa.
design exceeds requirements for IECC 2009 Performance compliance by 6.5%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 10/21/19 at 2:03 PM
Ekotrope RATER - Version 3.2.2.2279
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
11937 WEST RD
ZIONSVILLE, IN 46077
Builder: PAUL SHOOPMAN HOME BUILDING GROUP
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-10
Framed Floor NIA
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 4 ACH50
Window U-Value: 0.3, SHGC: 0.25
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 168 CFM @ 25Pa (3.95 / 100 s.f.)
Total Duct Leakage 336 CFM @ 25Pa (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
10/21 / 19 at 2:03 PM
Ekotrope RATER - Version 3.2.2.2279
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property
Organization
11937 WEST RD
TSI Energy Solutions
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONT AT WE,:
Builder
PAULSHOOP MAN
WWC52 (AS DESIGNED)
HOME BUILDING
WATER FRDNIT AT WEST CLAP 52
GROUP
General Building Information
Conditioned Area (sq ft) 4,254
Conditioned Volume (cubic ft) 46,095
Insulated Shell Area (sq ft) 10,636
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT(1,069 s.f., 57 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
[ Name: CRAWL(2,116 s.f., 211 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
]l Name: CONDIAMB FIN (Exterior Perimeter [ft]: 35, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 0.00
Fully insulated (top to bottom)
[ Name: CONDfGAR (Exterior Perimeter [ft]: 22, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R-0 continuous insulation, R-0 cavity insulation
Insulation Grade: I
Fully insulated (tap to bottom)
El Name: CRAWLIAMB (Exterior Perimeter [ft]: 172, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
R: 10.00
Fully insulated (top to bottom)
El Name: CRAWLIGARAGE (Exterior Perimeter [ft]: 39, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
R: 10.00
Fully insulated (top to bottom)
Energy Code Inspection Checklist
P ro pe rty
11937 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WE,:
WWC52 (AS DESIGNED)
WATER FRONT AT WEST CLAP 52
Above Grade Wall
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN
HOME BUILDING
GROUP
Name: CONDIAMB (2,079 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIGAR (468 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (278 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CONDIAMB (217 s.f.)
R: 13.575
El Name: CONDIGAR (52 s.f.)
R: 13.575
Roof
Name: MAIN (3,085 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Name: VAULT (126 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.476
El Name: GARAGE (24 s.f.)
U: 0.182
Inspection Status
Results are projected
CTMEnergy Solutions
2
Energy Code Inspection Checklist
Property
11937 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WE,:
WWC52 (AS DESIGNED)
WATER FRONT AT WEST CLAP 52
Name: GARAGE (24 s.f.)
U: 0.182
Glazing
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAULSHCOP MAN
HOME BUILDING
GROUP
Inspection Status
Results are projected
El Name: FRONT (74 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH
11 Name: BACK (126 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
11 Name: SLIDER (96 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
11 Name: CURTAIN WALL (160 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
E] Name: BACK BSMT (30 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
E] Name: LEFT (62 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST
E] Name: RIGHT (54 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
ElMechanical ventilation system rated for, and capable of, providing continuous ventilation.
System shall include automatic timing controls.
System type: Exhaust Only, 24 hrsiday, 9 Watts.
Mechanical Equipment
El HEATING • Natural Gas • 100% Heating Load @ 92.1 AFUE
El COOLING • Electric • 100% Cooling Load @ 13 SEER
Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
11937 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WE,:
WWC52 (AS DESIGNED)
WATER FRONT AT WEST CLAP 52
Air Leakage Control
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAULSHCOP MAN
HOME BUILDING
GROUP
inspection Status
Results are projected
Test Status: Blower -door tested
House is air -sealed as to achieve 3,073 CFM50 (4.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 168 C F M @ 25Pa (3.95 / 100 s.f.)
Total Leakage specified as: 336 CFM @ 25Pa (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage t= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization
Inspection Status
*Sl Energy Solutions
11937 WEST RD
TSI Energy Solutions
Results are projected
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONTAT WEST CLAY 52
Builder
PAUL SHOOPMAN HOME
WWC52 (AS DESIGNED)
BUILDING GROUP
WATERFRONTAT WEST CLAY 52
eneral Building Information
mber Of Bedrooms
4
mber Of Floors
1
nditioned Floor Area [sq. ft.]
4,254
conditioned; attached garage?
Yes
nditioned Volume [cu. ft.]
I
46,095
tal Units in Building
1
sidence Type
Single family detached
oor Number
odel
HERON
mmunity
WATERFRONT AT WEST CLAY 52
mate Zone
5A
I -Foundation Wall
Name Library type
Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB FIN Uninsulated
1
8
35 Exposed Exterior Conditioned Space
CONDIGAR Uninsulated
1
8
22 Exposed Exterior Conditioned Space
CRAWLIAMB R-10 Draped, Full
1
2
172 Exposed Exterior Conditioned Crawlspace
CRAWLIGARAGE R-10 Draped, Full
1
2
39 Exposed Exterior Conditioned Crawlspace
Foundation Wall Library Li
Name Feet From Wall Top To
Feet From Wall Top To Is Fully
Insulated Continuous R-value
Cavity R-value Effective Insulation R-
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R-10 Draped; Full NiA
NIA
Yes
NIA N.'A 10.00
Uninsulated NIA
NIA
Yes
NIA NIA 0.00
Uninsulated NIA
NIA
Yes
0.00 NIA NIA
Slab
Name Library Type
Perimeter Floor Grade
Carpet Exposed
Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated
57 Below Grade
123 0
1:069.0 ft' Exposed Exterior Conditioned
Space
CRAWL Uninsulated
211 Below Grade
123 a
2,116.0 ftz Exposed Exterior Conditioned
Crawlspace
1
Building Summary
*Sl Energy Solutions
Property Organization Inspection Status
11937 WEST RD TSI Energy Solutions Results are projected
ZIONSVILLE, IN 46077 Devin Sielschott
Model: HERON
Community: WATERFRONTAT WEST CLAY 52 Builder
PAUL SHOOPMAN HOME
WWC52 (AS DESIGNED) BUILDING GROUP
WATERFRONTAT WEST CLAY 52
Fslab-11brary'Fist
Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value
Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated Woad Frame 1 Other No ❑ 0 ❑ No 0.00
Framed Floor
None Present
Framed Floor Library List
None Present
Rim Joist
Name
CONDIAMB
CO N DIGAR
Rim Joist Library List
Name
G1 R-13, R-3.0
all
Name
CONDIAMB
CONDIATTIC
Library Type
Surface Area
r
Location
G1 R-13, R-3.0 217.0 fl' Exposed Exterior
G1 R-13, R3.0
52.0 fl' Unconditioned, attached garage
sulation R-value
13.575
n
G1 R-13 BATT, R3.0 Medium 2,079.0 ft' Exposed Exterior
G 1 R-13 BATT, R3.0 Medium 27130 ft' Attic
Building Summary
Property
11937 WEST RID
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONTAT WEST CLAY 52
WWC52 (AS DESIGNED)
WATERFRONTAT WEST CLAY 52
Name
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN HOME
BUILDING GROUP
Library Type
Inspection Status
Results are projected
Surface Color
Surface Area
*Sl Energy Solutions
Location
CONDIGAR GI R-13 Gar Walls
l;ledur-,
4613.0 ft'
Unconditioned, attached garage
Wall Library List
Name
Effective R-value
G1 R-13 BATT, R-3-0
15.12
G1 R-13 Gar Walls
11.141
Glazing
Name Library Type Wall Assignment Foundation Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-.30, SHGC-.25
CONDIAMB
0
0
0
North
126.0 TV
BACK BSMT U-.30. SHGC-25
CONDIAMB FIN
0
0
0
North
30.0 ttF
CURTAIN WALL U-.30. SHGG.25
CONDIAMB
0
0
0
North
160.0 rF
FRONT U-.30. SHGG25
CONDIAMB
0
0
❑
South
74.0 tt2
LEFT U-.30. SHGC-25
CONDIAMB
0
0
❑
West
62.0 tt2
RIGHT U-.30, SHGC-25
CONDIAMB
0
0
❑
East
54.0 tt2
SLIDER U-.30, SHGC-25
CONDIAMB
0
0
❑
North
96.0 tt2
Glazing Library Li
Name
U-.30. SHGC-.25
Skylight
Shg c U-facto r
025 0.30D
9
Building Summary
*Sl Energy Solutions
Property Organization Inspection Status
11937 WEST RD TSI Energy Solutions Results are projected
ZIONSVILLE, IN 46077 Devin Sielschott
Model: HERON
Community: WATERFRONTAT WEST CLAY 52 Builder
PAUL SHOOPMAN HOME
WWC52 (AS DESIGNED) BUILDING GROUP
WATERFRONTAT WEST CLAY 52
kylight Library
None Present
Opaque ❑o
Name Library 'TV pe Wall Assignment FoundatianWall Emittance Solar Surface Color Surface Area Location
Assign ment Absorpta nce
FRONT Wood Door CONDIAMB 0.9 0.75 Medium 24.0 111 Exposed Exterior
GARAGE FiberglasslSteel CONDIGAR 0.9 0.75 Medium 24.0 f12 Exposed Exterior
Door
GARAGE FiberglasslSteel CONDIGAR 0.9 0.75 Medium 24.0 f12 Exposed Exterior
Door
Opaque Door Library List
Name Effective J-factor
IFiberglass/Steel Door 0.182
Wood Door 0.476
Roof Insulation
Name Library type Attic Exterior Area [s.f.] Clay or Concrete Roof Surface Color Surface Area Location
Tiles
MAIN R-38 Blown, GRt 3,085 No Medium 3.085.0 f11 Attic
VAULT R-38 Vaulted. GRt 126 No Medium 126.0 ft' Vaulted Roof
Roof Insulation Library List
Name Has Radiant Barrier Effective R-value
R-8 Blown, GR1 No 38.268
R-38 Vaulted, GR1 No 32.263
4
Building Summary
Property
Organization
Inspection Status
*Sll Energy Solutions
11937 WEST RD
TSI Energy Solutions
Results are projected
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONTAT WEST CLAY 52
Builder
PAUL SHOOPMAN HOME
WWC52 (AS DESIGNED)
BUILDING GROUP
WATERFRONTAT WEST CLAY 52
Whale House Infiltration
Infiltration
Measurement
type
Shelter Class
4ACH at 50 Pa
Blower -door tested
4
Mechanical Ventilation
Ventilation Type Ventilation Rate
"" I
Operational hours per day
Fan Watts
Runs once every three Energy Recovery Percent
Minute]
hours
Exhaust Only
20
24
9
Yes 0
Lighting a-
% Interior Fluorescent % Interior LED Lighting
°% Exterior Fluorescent
% Exterior LED Lighting
% Garage Fluorescent % Garage LED Lighting
Lighting
Lighting
Lighting
0
0
a
0
a a
Gnsite Generation
None Present
Onsite Generation Library List qW
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Building Summary
Property
Organization
Inspection Status
*Sl
Energy Solutions
11937 WEST RD
TSI Energy Solutions
Results are projected
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONTAT WEST CLAY 52
Builder
PAUL SHOOPMAN HOME
WWC52 (AS DESIGNED)
BUILDING GROUP
WATERFRONTAT WEST CLAY 52
onditioning Equipment
Name Library Type
Heating Percent Load
Cooling Percent Load
Hot Water Percent Load
Location
COOLING CA13MA048
0%
100%
0%
Conditioned Space
HEATING 912SA48100S21
100%
0%
0%
Conditioned Space
Water Heating ENT 50 100
0%
0%
100%
Conditioned Space
1
Equipment Type: 912SA481005
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 93
Use default EAE No
EAE [kWh] 756
Equipment Type: CAUNA048
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
45.5
■
Equipment Type: ENT 50 100
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
on
Building Summary
Property
11937 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONTAT WEST CLAY 52
WWC52 (AS DESIGNED)
WATERFRONTAT WEST CLAY 52
butivn System
on Type
-quipment
-quipment
Served
Grilles
luct R Value
luct R Value
Iuct Area [ftJ
ud Area 1ft9
to Outdoors
Ikage
Ikage Duct Test Conditions
cult Flow Rate
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN HOME
BUILDING GROUP
Forced Air
HEATING
COOLING
4254
4
10
10
1148.58
850.8
168 CFM @ 25Pa (3.951 100 s.f.)
336 CFM25
Post -Construction
Yes
Attic (well vented, under insulation)
50
50
Conditioned Space
50
50
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C"IEnergy Solutions
7
Building Summary
Property
11937 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONTAT WEST CLAY 52
WWC52 (AS DESIGNED)
WATERFRONTAT WEST CLAY 52
Water Distribution
tillillillit
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
[An
thes Washer
l Energy Rating
ric Rate
al Gas Cost
Rate
city
ppliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
RangefOven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
PAUL SHOOPMAN HOME
BUILDING GROUP
Standard
No
45
No
No
10
No
Electric
Timer Controls
704 kWh[Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Electric
No
No
709 kWh[Year
C"IEnergy Solutions
,3