HomeMy WebLinkAboutGN010.0- Energy CertificateIECC 2909 Performance Compliance P ro pe rty 11937 WEST RD ZIONSVILLE, IN 46077 Model: HERON Community: WATERFRONT AT WE,: WWC52 (AS DESIGNED) WATER FRONT AT WEST CLAP 52 Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,450 $258 $369 $2,077 $1,184 $0 $3,262 Requirements 405.3 Performance -based compliance passes by 6.5% ® R402.4.12 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC ® 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C",Erergy Solutions As Designed $1,390 $183 $369 $1,942 $1,161 $0 $3,103 Air sealing is 4.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 5D Pa. design exceeds requirements for IECC 2009 Performance compliance by 6.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 10/21/19 at 2:03 PM Ekotrope RATER - Version 3.2.2.2279 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 11937 WEST RD ZIONSVILLE, IN 46077 Builder: PAUL SHOOPMAN HOME BUILDING GROUP Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-10 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 4 ACH50 Window U-Value: 0.3, SHGC: 0.25 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 168 CFM @ 25Pa (3.95 / 100 s.f.) Total Duct Leakage 336 CFM @ 25Pa (Post -Construction) Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 10/21 / 19 at 2:03 PM Ekotrope RATER - Version 3.2.2.2279 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 11937 WEST RD TSI Energy Solutions ZIONSVILLE, IN 46077 Devin Sielschott Model: HERON Community: WATERFRONT AT WE,: Builder PAULSHOOP MAN WWC52 (AS DESIGNED) HOME BUILDING WATER FRDNIT AT WEST CLAP 52 GROUP General Building Information Conditioned Area (sq ft) 4,254 Conditioned Volume (cubic ft) 46,095 Insulated Shell Area (sq ft) 10,636 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT(1,069 s.f., 57 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. [ Name: CRAWL(2,116 s.f., 211 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall ]l Name: CONDIAMB FIN (Exterior Perimeter [ft]: 35, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 0.00 Fully insulated (top to bottom) [ Name: CONDfGAR (Exterior Perimeter [ft]: 22, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R-0 continuous insulation, R-0 cavity insulation Insulation Grade: I Fully insulated (tap to bottom) El Name: CRAWLIAMB (Exterior Perimeter [ft]: 172, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2) R: 10.00 Fully insulated (top to bottom) El Name: CRAWLIGARAGE (Exterior Perimeter [ft]: 39, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2) R: 10.00 Fully insulated (top to bottom) Energy Code Inspection Checklist P ro pe rty 11937 WEST RD ZIONSVILLE, IN 46077 Model: HERON Community: WATERFRONT AT WE,: WWC52 (AS DESIGNED) WATER FRONT AT WEST CLAP 52 Above Grade Wall Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Name: CONDIAMB (2,079 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIGAR (468 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (278 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (217 s.f.) R: 13.575 El Name: CONDIGAR (52 s.f.) R: 13.575 Roof Name: MAIN (3,085 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Name: VAULT (126 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (24 s.f.) U: 0.476 El Name: GARAGE (24 s.f.) U: 0.182 Inspection Status Results are projected CTMEnergy Solutions 2 Energy Code Inspection Checklist Property 11937 WEST RD ZIONSVILLE, IN 46077 Model: HERON Community: WATERFRONT AT WE,: WWC52 (AS DESIGNED) WATER FRONT AT WEST CLAP 52 Name: GARAGE (24 s.f.) U: 0.182 Glazing Organization TSI Energy Solutions Devin Sielschott Builder PAULSHCOP MAN HOME BUILDING GROUP Inspection Status Results are projected El Name: FRONT (74 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH 11 Name: BACK (126 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH 11 Name: SLIDER (96 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH 11 Name: CURTAIN WALL (160 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH E] Name: BACK BSMT (30 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH E] Name: LEFT (62 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST E] Name: RIGHT (54 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST Skylight None Present Mechanical Ventilation ElMechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 24 hrsiday, 9 Watts. Mechanical Equipment El HEATING • Natural Gas • 100% Heating Load @ 92.1 AFUE El COOLING • Electric • 100% Cooling Load @ 13 SEER Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor C", Energy Solutions 3 Energy Code Inspection Checklist Property 11937 WEST RD ZIONSVILLE, IN 46077 Model: HERON Community: WATERFRONT AT WE,: WWC52 (AS DESIGNED) WATER FRONT AT WEST CLAP 52 Air Leakage Control Organization TSI Energy Solutions Devin Sielschott Builder PAULSHCOP MAN HOME BUILDING GROUP inspection Status Results are projected Test Status: Blower -door tested House is air -sealed as to achieve 3,073 CFM50 (4.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 168 C F M @ 25Pa (3.95 / 100 s.f.) Total Leakage specified as: 336 CFM @ 25Pa (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage t= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status *Sl Energy Solutions 11937 WEST RD TSI Energy Solutions Results are projected ZIONSVILLE, IN 46077 Devin Sielschott Model: HERON Community: WATERFRONTAT WEST CLAY 52 Builder PAUL SHOOPMAN HOME WWC52 (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 52 eneral Building Information mber Of Bedrooms 4 mber Of Floors 1 nditioned Floor Area [sq. ft.] 4,254 conditioned; attached garage? Yes nditioned Volume [cu. ft.] I 46,095 tal Units in Building 1 sidence Type Single family detached oor Number odel HERON mmunity WATERFRONT AT WEST CLAY 52 mate Zone 5A I -Foundation Wall Name Library type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB FIN Uninsulated 1 8 35 Exposed Exterior Conditioned Space CONDIGAR Uninsulated 1 8 22 Exposed Exterior Conditioned Space CRAWLIAMB R-10 Draped, Full 1 2 172 Exposed Exterior Conditioned Crawlspace CRAWLIGARAGE R-10 Draped, Full 1 2 39 Exposed Exterior Conditioned Crawlspace Foundation Wall Library Li Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R-10 Draped; Full NiA NIA Yes NIA N.'A 10.00 Uninsulated NIA NIA Yes NIA NIA 0.00 Uninsulated NIA NIA Yes 0.00 NIA NIA Slab Name Library Type Perimeter Floor Grade Carpet Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 57 Below Grade 123 0 1:069.0 ft' Exposed Exterior Conditioned Space CRAWL Uninsulated 211 Below Grade 123 a 2,116.0 ftz Exposed Exterior Conditioned Crawlspace 1 Building Summary *Sl Energy Solutions Property Organization Inspection Status 11937 WEST RD TSI Energy Solutions Results are projected ZIONSVILLE, IN 46077 Devin Sielschott Model: HERON Community: WATERFRONTAT WEST CLAY 52 Builder PAUL SHOOPMAN HOME WWC52 (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 52 Fslab-11brary'Fist Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Woad Frame 1 Other No ❑ 0 ❑ No 0.00 Framed Floor None Present Framed Floor Library List None Present Rim Joist Name CONDIAMB CO N DIGAR Rim Joist Library List Name G1 R-13, R-3.0 all Name CONDIAMB CONDIATTIC Library Type Surface Area r Location G1 R-13, R-3.0 217.0 fl' Exposed Exterior G1 R-13, R3.0 52.0 fl' Unconditioned, attached garage sulation R-value 13.575 n G1 R-13 BATT, R3.0 Medium 2,079.0 ft' Exposed Exterior G 1 R-13 BATT, R3.0 Medium 27130 ft' Attic Building Summary Property 11937 WEST RID ZIONSVILLE, IN 46077 Model: HERON Community: WATERFRONTAT WEST CLAY 52 WWC52 (AS DESIGNED) WATERFRONTAT WEST CLAY 52 Name Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Library Type Inspection Status Results are projected Surface Color Surface Area *Sl Energy Solutions Location CONDIGAR GI R-13 Gar Walls l;ledur-, 4613.0 ft' Unconditioned, attached garage Wall Library List Name Effective R-value G1 R-13 BATT, R-3-0 15.12 G1 R-13 Gar Walls 11.141 Glazing Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.30, SHGC-.25 CONDIAMB 0 0 0 North 126.0 TV BACK BSMT U-.30. SHGC-25 CONDIAMB FIN 0 0 0 North 30.0 ttF CURTAIN WALL U-.30. SHGG.25 CONDIAMB 0 0 0 North 160.0 rF FRONT U-.30. SHGG25 CONDIAMB 0 0 ❑ South 74.0 tt2 LEFT U-.30. SHGC-25 CONDIAMB 0 0 ❑ West 62.0 tt2 RIGHT U-.30, SHGC-25 CONDIAMB 0 0 ❑ East 54.0 tt2 SLIDER U-.30, SHGC-25 CONDIAMB 0 0 ❑ North 96.0 tt2 Glazing Library Li Name U-.30. SHGC-.25 Skylight Shg c U-facto r 025 0.30D 9 Building Summary *Sl Energy Solutions Property Organization Inspection Status 11937 WEST RD TSI Energy Solutions Results are projected ZIONSVILLE, IN 46077 Devin Sielschott Model: HERON Community: WATERFRONTAT WEST CLAY 52 Builder PAUL SHOOPMAN HOME WWC52 (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 52 kylight Library None Present Opaque ❑o Name Library 'TV pe Wall Assignment FoundatianWall Emittance Solar Surface Color Surface Area Location Assign ment Absorpta nce FRONT Wood Door CONDIAMB 0.9 0.75 Medium 24.0 111 Exposed Exterior GARAGE FiberglasslSteel CONDIGAR 0.9 0.75 Medium 24.0 f12 Exposed Exterior Door GARAGE FiberglasslSteel CONDIGAR 0.9 0.75 Medium 24.0 f12 Exposed Exterior Door Opaque Door Library List Name Effective J-factor IFiberglass/Steel Door 0.182 Wood Door 0.476 Roof Insulation Name Library type Attic Exterior Area [s.f.] Clay or Concrete Roof Surface Color Surface Area Location Tiles MAIN R-38 Blown, GRt 3,085 No Medium 3.085.0 f11 Attic VAULT R-38 Vaulted. GRt 126 No Medium 126.0 ft' Vaulted Roof Roof Insulation Library List Name Has Radiant Barrier Effective R-value R-8 Blown, GR1 No 38.268 R-38 Vaulted, GR1 No 32.263 4 Building Summary Property Organization Inspection Status *Sll Energy Solutions 11937 WEST RD TSI Energy Solutions Results are projected ZIONSVILLE, IN 46077 Devin Sielschott Model: HERON Community: WATERFRONTAT WEST CLAY 52 Builder PAUL SHOOPMAN HOME WWC52 (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 52 Whale House Infiltration Infiltration Measurement type Shelter Class 4ACH at 50 Pa Blower -door tested 4 Mechanical Ventilation Ventilation Type Ventilation Rate "" I Operational hours per day Fan Watts Runs once every three Energy Recovery Percent Minute] hours Exhaust Only 20 24 9 Yes 0 Lighting a- % Interior Fluorescent % Interior LED Lighting °% Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting 0 0 a 0 a a Gnsite Generation None Present Onsite Generation Library List qW None Present Solar Generation None Present Solar Generation Library List None Present Building Summary Property Organization Inspection Status *Sl Energy Solutions 11937 WEST RD TSI Energy Solutions Results are projected ZIONSVILLE, IN 46077 Devin Sielschott Model: HERON Community: WATERFRONTAT WEST CLAY 52 Builder PAUL SHOOPMAN HOME WWC52 (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 52 onditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location COOLING CA13MA048 0% 100% 0% Conditioned Space HEATING 912SA48100S21 100% 0% 0% Conditioned Space Water Heating ENT 50 100 0% 0% 100% Conditioned Space 1 Equipment Type: 912SA481005 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 93 Use default EAE No EAE [kWh] 756 Equipment Type: CAUNA048 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 45.5 ■ Equipment Type: ENT 50 100 Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 on Building Summary Property 11937 WEST RD ZIONSVILLE, IN 46077 Model: HERON Community: WATERFRONTAT WEST CLAY 52 WWC52 (AS DESIGNED) WATERFRONTAT WEST CLAY 52 butivn System on Type -quipment -quipment Served Grilles luct R Value luct R Value Iuct Area [ftJ ud Area 1ft9 to Outdoors Ikage Ikage Duct Test Conditions cult Flow Rate :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area rCeiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Forced Air HEATING COOLING 4254 4 10 10 1148.58 850.8 168 CFM @ 25Pa (3.951 100 s.f.) 336 CFM25 Post -Construction Yes Attic (well vented, under insulation) 50 50 Conditioned Space 50 50 Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C"IEnergy Solutions 7 Building Summary Property 11937 WEST RD ZIONSVILLE, IN 46077 Model: HERON Community: WATERFRONTAT WEST CLAY 52 WWC52 (AS DESIGNED) WATERFRONTAT WEST CLAY 52 Water Distribution tillillillit Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization [An thes Washer l Energy Rating ric Rate al Gas Cost Rate city ppliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency RangefOven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Standard No 45 No No 10 No Electric Timer Controls 704 kWh[Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Electric No No 709 kWh[Year C"IEnergy Solutions ,3