HomeMy WebLinkAboutCLAY CORNER 39 - CC039 (AS DESIGNED)IECC 2909 Performance Compliance
Property
1559 JENSEN ❑R
CARMEL, IN 46032
Model: CHARTWELL (C)
Community: CLAY CORNER 39
CC039 (AS DESIGNED)
CLAY CORNER 39
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,178
$194
$375
$1,747
$564
$0
$2,311
Requirements
C4405.3
Performance -based compliance passes by 15.8%
R402.4.12
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U-Factor
40322
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4D52
Duct Insulation
C-M,
Energy Solutions
As Designed
$948
$149
$375
$1,471
$564
$0
$2,036
Air sealing is 5.00 ACH at 54 Pa. It must not exceed 7.00 ACH at 5D Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 15.8%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 9/19/19 at 9:00 AM
Ekotrope RATER - Version 3.1.0.2256
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
1559 JENSEN DR
CARMEL, IN 46032
Builder: LENNAR HOMES
I kkT, NN 174I
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U-Value: 0.33, SHGC: 0.28
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 105 CFM25 (4.951 100 s.f.)
Total Duct Leakage 168 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 95.5AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
9i 19/19 at 9:00 AM
Ekotrope RATER - Version 3.1.0.225E
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property Organization
1559 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: CHARTVVELL (C)
Community: CLAY CORNER 39 Builder
LENNAR HOMES
CC039 (AS DESIGNED)
CLAY CORNER 39
General Building Information
Conditioned Area (sq ft) 2,123
Conditioned Volume (cubicft) 19,107
Insulated Shell Area (sq ft) 6,172
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB(2,123 s.f., 214 ft. exterior perimeter)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CON DIAM B 2X4 (1,746 s.f. )
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CON DIGAR (180 s.f. )
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
None Present
Roof
1
Energy Code Inspection Checklist
Property
Organization
1559 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL (C)
Community: CLAY CORNER 39
Builder
LENNAR HOMES
CC039 (AS DESIGNED)
CLAY CORNER 39
Name: SECOND (2,123 s.f.)
R-27.55 continuous insulation,
R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (72 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH
E] Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH
El Name: LEFT SIDE (63 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
El Name: LEFT SIDE GD (18 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
El Name: RIGHT SIDE (53 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
M Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
1559 JENSEN DR
CARMEL, IN 46032
Model: CHARTVVELL (C)
Community: CLAY CORNER 39
CC039 (AS DESIGNED)
CLAY CORNER 39
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
inspection Status
Results are projected
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,592 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 105 CFM25 (4.95 / 100 s.f.)
Total Leakage specified as: 168 CFM25 (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes 3
5N5
Building Summary
Property
1559JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL (C)
Community: CLAY CORNER 39
CCD.39 (AS DESIGNED)
CLAY CORNER 39
eneral Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq. ft.]
Unconditioned; attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Floor Number
Model
Community
Climate Zone
Foundation Wall
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
4
1
2,123
Yes
19,107
1
Single family detached
CHARTWELL (C)
CLAY CORNER 39
5A
None Present
Foundation Wall Library List
None
Inspection Status
Results are projected
C-M,
Energy Solutions
Slab
Name Library Type
Perimeter
Floor Grade Carpet R Exposed
Masonry Area
Surface Area
Location
Enclosing
SLAB R-10, 2'down
214
On Grade 0 0
2,123.0 ft'
Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction
Slab Completely
Underslab Perimeter
Perimeter
Thermal Break
Effective R-value
Type
Insulated.
Insulation Width [ft] Insulation Depth [ft] Insulation R Value
R-10, 2'down Wood Frame 1 Other
No
0 2
10
No
0.00
Framed Floor
None Present
1
Building Summary
Property Organization
1559 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL (C)
Community: CLAY CORNER 39 Builder
LENNAR HOMES
CC❑39 (AS DESIGNED)
CLAY CORNER 39
Floor Library
None Present
Rim Joist
None Present
Rim Joist Library List
None Present
Name
Library Type
CONDIAMB 2X4 G 1 R-13 BATT, R3.0
CONDIGAR
G1 R-13 Gar Walls
Wall Library List
Name
E
G1 R-13 BATT, R-3.0
G1 R-13 Gar Walls
Glazing
Name Library IVpe
Wall Assignment
BACK U-.33, SHGC-28
CONDIAMB 2X4
FRONT U-.33, SHGG28
CONDIAMB 2X4
1
ue
15.12
Inspection Status
Results are projected
C-M,
Energy Solutions
Surface Color Surface Area Location
Medium 1.746.0 tt' Exposed Exterior
Medium 180.0 tt, Unconditioned, attached garage
❑ 0 ❑ North 90.0 rL2
❑ 0 0 South 72.0 R2
Building Summary
Property Organization
Inspection Status
Energy
C-M
Solutions
1559 JENSEN DR TSI Energy Solutions
Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL (C)
Community: CLAY CORNER 39 Builder
LENNAR HOMES
CCD39 (AS DESIGNED)
CLAY CORNER 39
Name Library Type Wall Assignment Foundation Wall
Overhang Depth Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
LEFT SI DE U-.33, SHGG28 CONDIAMB 2X4
0 0
0
West
63.0 Pt'
LEFT SIDE GD U-.33, SHGG28 CONDIAMB 2X4
0 0
0
West
18.0 f[,
RIGHT SI DE U-.33, SHGG28 CONDIAMB 2X4
0 0
0
East
53.0 R'
Glazing Library List
Name Shgc
U-factor
U-.33, SHGC-.28 0.28
0.330
Skylight
Skylight Library List
Opaque Door
Name Library type Wall Ass ignmen,
FRONT Fiberglass Door CONDIAMB 2X4
GARAGE Fiberglass Door CONDIGAR
Opaque Door Library List
Name
Fiberglass Door
Assignment
Effective U-factor
0.182
n
Absorptance
0.9 0.75 Medium 20.0 it' Exposed Exterior
D.9 0.75 Medium 180111 Exposed Exterior
9
Building Summary
Property Organization
Inspection Status
C-M
Energy Solutions
1559 JENSEN DR TSI Energy Solutions
Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL (C)
Community: CLAY CORNER 39 Builder
LENNAR HOMES
CCD.39 (AS DESIGNED)
CLAY CORNER 39
Roof Insulation
Name Library type Attic ExterrorArea [s.f.]
Clay or Concrete Roof Surface Color
Surface Area
Location
Tiles
SECOND R-38 Blown, GRt 2,123
Attic
No Medium
2,123.0 f1'
Roof Insulation Library List
Name Has Radiant Barrier
Effective R-value
R-38 Blown, GR1 No
38.269
Whale House Infiltration
i
Infiltration Measurement Type
Shelter Class
5ACH at 50 Pa Blower -door tested
4
Mechanical Ventilation
None Present
Lighting iiiA��Rii
°I Interior Fluorescent °I Interior LED Lighting °i Exterior Fluorescent % Exterior LED Lighting °I Garage
Fluorescent
% Garage LED Lighting
Lighting
Lighting
Lighting
C 110C
100
9 100
C
Onsite Generation
■
None Present
4
Building Summary
Property Organization
1559 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL (C)
Community: CLAY CORNER 39 Builder
LENNAR HOMES
CCD39 (AS DESIGNED)
CLAY CORNER 39
nsite Generation Library List
None Present
Solar Generation
one
Inspection Status
Results are projected
C-M,
Energy Solutions
Solar Generation Library List
None Present
Conditioning Equipment
Name Library type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location
Airconditioner 4AC`42P
0% 100% 0% Conditioned Space
Fuel -fired air 9155A48080517
distribution
100% 0% 0% Conditioned Space
Water Heating RE350'
0% 0% 100% Conditioned Space
Equipment Type: 4AC*42P
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSC (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 46
Equipment Type: 915SA48080S17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
946
A
Building Summary
Property
Energy Solutions
Organization Inspection Status C-M
1559 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL (C)
Community: CLAY CORNER 39
Builder
LENNAR HOMES
CCD39 (AS DESIGNED)
CLAY CORNER 39
quipment Type: RE.
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulhl
15.4
Recovery Efficiency
0.98
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
2123
# Return Grilles
5
Supply Duct R Value
10
Return Dud R Value
10
Supply Duct Area [ftq
114642
Return Dud Area [ItJ
1061.5
Leakage to Outdoors
105 CFM25 (4.95 1100 s.f.)
Total Leakage
168 CFM25
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
5
Percent Return Area
5
Duct 2
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
95
Percent Return Area
95
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
'-Ceiling Fan -
Has Ceiling Fan No
Cfm Per Watt 101
Al
Building Summary
Property
1559JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL (C)
Community: CLAY CORNER 39
CCD39 (AS DESIGNED)
CLAY CORNER 39
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Water Distribution0
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
ppliances and Controls
Programmabie thermostat?
Dishwasher Size
Dishwasher Efficiency
RangefOven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
5N5
Standard
No
50
No
No
30
No
Electric
Timer Controls
704 kWh[Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh[Year
C-M,
Energy Solutions
7