HomeMy WebLinkAboutCLAY CORNER 39 - CC039 (AS DESIGNED)IECC 2909 Performance Compliance Property 1559 JENSEN ❑R CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 39 CC039 (AS DESIGNED) CLAY CORNER 39 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,178 $194 $375 $1,747 $564 $0 $2,311 Requirements C4405.3 Performance -based compliance passes by 15.8% R402.4.12 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4D52 Duct Insulation C-M, Energy Solutions As Designed $948 $149 $375 $1,471 $564 $0 $2,036 Air sealing is 5.00 ACH at 54 Pa. It must not exceed 7.00 ACH at 5D Pa. Design exceeds requirements for IECC 2009 Performance compliance by 15.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9/19/19 at 9:00 AM Ekotrope RATER - Version 3.1.0.2256 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 1559 JENSEN DR CARMEL, IN 46032 Builder: LENNAR HOMES I kkT, NN 174I Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 105 CFM25 (4.951 100 s.f.) Total Duct Leakage 168 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 95.5AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9i 19/19 at 9:00 AM Ekotrope RATER - Version 3.1.0.225E 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 1559 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: CHARTVVELL (C) Community: CLAY CORNER 39 Builder LENNAR HOMES CC039 (AS DESIGNED) CLAY CORNER 39 General Building Information Conditioned Area (sq ft) 2,123 Conditioned Volume (cubicft) 19,107 Insulated Shell Area (sq ft) 6,172 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB(2,123 s.f., 214 ft. exterior perimeter) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CON DIAM B 2X4 (1,746 s.f. ) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CON DIGAR (180 s.f. ) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist None Present Roof 1 Energy Code Inspection Checklist Property Organization 1559 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 39 Builder LENNAR HOMES CC039 (AS DESIGNED) CLAY CORNER 39 Name: SECOND (2,123 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (72 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH E] Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH El Name: LEFT SIDE (63 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: LEFT SIDE GD (18 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: RIGHT SIDE (53 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment M Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER C-M, Energy Solutions 2 Energy Code Inspection Checklist Property 1559 JENSEN DR CARMEL, IN 46032 Model: CHARTVVELL (C) Community: CLAY CORNER 39 CC039 (AS DESIGNED) CLAY CORNER 39 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES inspection Status Results are projected E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,592 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 105 CFM25 (4.95 / 100 s.f.) Total Leakage specified as: 168 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 3 5N5 Building Summary Property 1559JENSEN DR CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 39 CCD.39 (AS DESIGNED) CLAY CORNER 39 eneral Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq. ft.] Unconditioned; attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 4 1 2,123 Yes 19,107 1 Single family detached CHARTWELL (C) CLAY CORNER 39 5A None Present Foundation Wall Library List None Inspection Status Results are projected C-M, Energy Solutions Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Masonry Area Surface Area Location Enclosing SLAB R-10, 2'down 214 On Grade 0 0 2,123.0 ft' Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completely Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 2'down Wood Frame 1 Other No 0 2 10 No 0.00 Framed Floor None Present 1 Building Summary Property Organization 1559 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 39 Builder LENNAR HOMES CC❑39 (AS DESIGNED) CLAY CORNER 39 Floor Library None Present Rim Joist None Present Rim Joist Library List None Present Name Library Type CONDIAMB 2X4 G 1 R-13 BATT, R3.0 CONDIGAR G1 R-13 Gar Walls Wall Library List Name E G1 R-13 BATT, R-3.0 G1 R-13 Gar Walls Glazing Name Library IVpe Wall Assignment BACK U-.33, SHGC-28 CONDIAMB 2X4 FRONT U-.33, SHGG28 CONDIAMB 2X4 1 ue 15.12 Inspection Status Results are projected C-M, Energy Solutions Surface Color Surface Area Location Medium 1.746.0 tt' Exposed Exterior Medium 180.0 tt, Unconditioned, attached garage ❑ 0 ❑ North 90.0 rL2 ❑ 0 0 South 72.0 R2 Building Summary Property Organization Inspection Status Energy C-M Solutions 1559 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 39 Builder LENNAR HOMES CCD39 (AS DESIGNED) CLAY CORNER 39 Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom LEFT SI DE U-.33, SHGG28 CONDIAMB 2X4 0 0 0 West 63.0 Pt' LEFT SIDE GD U-.33, SHGG28 CONDIAMB 2X4 0 0 0 West 18.0 f[, RIGHT SI DE U-.33, SHGG28 CONDIAMB 2X4 0 0 0 East 53.0 R' Glazing Library List Name Shgc U-factor U-.33, SHGC-.28 0.28 0.330 Skylight Skylight Library List Opaque Door Name Library type Wall Ass ignmen, FRONT Fiberglass Door CONDIAMB 2X4 GARAGE Fiberglass Door CONDIGAR Opaque Door Library List Name Fiberglass Door Assignment Effective U-factor 0.182 n Absorptance 0.9 0.75 Medium 20.0 it' Exposed Exterior D.9 0.75 Medium 180111 Exposed Exterior 9 Building Summary Property Organization Inspection Status C-M Energy Solutions 1559 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 39 Builder LENNAR HOMES CCD.39 (AS DESIGNED) CLAY CORNER 39 Roof Insulation Name Library type Attic ExterrorArea [s.f.] Clay or Concrete Roof Surface Color Surface Area Location Tiles SECOND R-38 Blown, GRt 2,123 Attic No Medium 2,123.0 f1' Roof Insulation Library List Name Has Radiant Barrier Effective R-value R-38 Blown, GR1 No 38.269 Whale House Infiltration i Infiltration Measurement Type Shelter Class 5ACH at 50 Pa Blower -door tested 4 Mechanical Ventilation None Present Lighting iiiA��Rii °I Interior Fluorescent °I Interior LED Lighting °i Exterior Fluorescent % Exterior LED Lighting °I Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting C 110C 100 9 100 C Onsite Generation ■ None Present 4 Building Summary Property Organization 1559 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 39 Builder LENNAR HOMES CCD39 (AS DESIGNED) CLAY CORNER 39 nsite Generation Library List None Present Solar Generation one Inspection Status Results are projected C-M, Energy Solutions Solar Generation Library List None Present Conditioning Equipment Name Library type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location Airconditioner 4AC`42P 0% 100% 0% Conditioned Space Fuel -fired air 9155A48080517 distribution 100% 0% 0% Conditioned Space Water Heating RE350' 0% 0% 100% Conditioned Space Equipment Type: 4AC*42P Fuel Type Electric Distribution Type Forced Air Motor Type PSC (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 46 Equipment Type: 915SA48080S17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 A Building Summary Property Energy Solutions Organization Inspection Status C-M 1559 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 39 Builder LENNAR HOMES CCD39 (AS DESIGNED) CLAY CORNER 39 quipment Type: RE. Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulhl 15.4 Recovery Efficiency 0.98 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 2123 # Return Grilles 5 Supply Duct R Value 10 Return Dud R Value 10 Supply Duct Area [ftq 114642 Return Dud Area [ItJ 1061.5 Leakage to Outdoors 105 CFM25 (4.95 1100 s.f.) Total Leakage 168 CFM25 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 5 Percent Return Area 5 Duct 2 Duct Location Attic (well vented, under insulation) Percent Supply Area 95 Percent Return Area 95 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ '-Ceiling Fan - Has Ceiling Fan No Cfm Per Watt 101 Al Building Summary Property 1559JENSEN DR CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 39 CCD39 (AS DESIGNED) CLAY CORNER 39 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Water Distribution0 Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef ppliances and Controls Programmabie thermostat? Dishwasher Size Dishwasher Efficiency RangefOven Fuel Convection Oven? Induction Range? Refrigerator Consumption 5N5 Standard No 50 No No 30 No Electric Timer Controls 704 kWh[Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh[Year C-M, Energy Solutions 7