HomeMy WebLinkAboutCOP 017 - Energy Certificate12904 COPPER RUN BLVD
CARMEL, IN 46074
Builder: PULTE HOMES
i'i ITS P
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor R-30
Infiltration 5 ACH50
Window U-Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 255 CFM @ 25Pa (4.961 100 s.f.)
Total Duct Leakage 411 CFM @ 25Pa (Post -Construction)
Heating Furnace • Natural Gas • 93AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.64 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adapted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certiry that the building design descrtbed herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspecteditested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the ]ECC or will be verified as such by another party.
Name:
Organization:
Michael Hill
TSI Energy Solutions
Signature -
Date:
10/14/19 at 9:20 AM
Ekotrope RATER - Version 3.1.0.2273
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RES NET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.