Loading...
HomeMy WebLinkAboutGN000.1LOT SPECIFIC PLAN INFORMATION Customer Name {\C256;* Market Home *, 6838-02300} Address{\C256;12957 COPPER RUN BOULEVARD}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074} Community{\Fsimplex|c0;\C256;6838}{\C256;COPPER RUN}{\C256;6838-02300} Plan Features{\C256;Elevation HR2Q} MUNICIPALITY STRUCTURAL ENGINEER APPLICABLE CODES\pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; } MECHANICAL ENGINEER BUILDING CODE ANALYSISZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: . DESIGN LOADS and CRITERIA\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} SHEET LIST TABLE SHT DESCRIPTION CC.01 Cover Sheet CC.02 Notes - Schedules and Legends CC.03 General Notes A0.01 Foundation - Basement A1.11 1st Floor Plan A1.21 2nd Floor Plan A2.01 Building Section A2.02 Building Section A2.03 Building Section A2.04 Building Section A3.01 Front Elevation A3.02 Left Elevation A3.03 Right Elevation A3.04 Rear Elevation A4.01 Roof Plan U0.01 Basement Utility Plan U1.11 1st Floor Utility Plan U1.21 2nd Floor Utility Plan Structural Plan - Foundation Basement (IN Code) Structural Plan - 1st Floor (IN Code) Structural Plan - 2nd Floor (IN Code) LOT SPECIFIC OPTION SELECTIONSBath 3 OptionOpt Basement Bath Rough-InOpt Boot Bench at Owner's EntryBuilt in Kitchen OptionOpt. Windows at Cafe Opt Coach Light - Location 1Opt Coach Light - Location 2Opt Coach Light - Location 3Opt. Covered Patio at RearOpt Double Sink Bowl at Bath 2Dining Room - Additional Windows Elevation HR2QNo OptionBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageMasonry Wrap - Sides and RearOwners Suite - Additional WindowsBase Owner's BathShower Option at Bath 3IndianaOpt Basement Window Well - Location 4 SQUARE FOOTAGE TOTAL:CONDITIONED - LIVABLE SF 1st Floor 2nd Floor 1829 SF 1527 SF 3356 SF TOTAL:CONDITIONED - NON-LIVABLE SF Basement - Unfinished 1279 SF 1279 SF TOTAL:UNCONDITIONED SF 3 Car Garage Side Covered Porch Front Porch 804 SF 168 SF 107 SF 1078 SF 5713 SF COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2017 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:12/12/2016 PROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Allison II 2377.300Home for * Market Home *, 6838-0230012957 Copper Run Boulevard, Carmel, IN 46074CC.01 11/12/19 David Rutti