Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I38916663.23_Copper_Run
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). October 16,2019 Liu, Xuegang Pages or sheets covered by this seal: I38916663 thru I38916707 My license renewal date for the state of Indiana is July 31, 2020. 23_Copper_Run 23 Copper Run IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE01 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916663 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-WBaIsPoGtVe7EscP9GLzebHIuBWXRmlQ?t0WagyT9l_ Scale = 1:49.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 2x4 3x4 4x6 2x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-5-0 19-5-0 -0-11-0 0-11-0 9-8-8 9-8-8 19-5-0 9-8-8 20-4-0 0-11-0 1-1-07-6-111-1-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.16 0.07 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 264 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 19-5-0. (lb) - Max Horz 33=-180(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 33, 18, 26, 28, 29, 30, 31, 32, 24, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 33, 18, 25, 26, 28, 29, 30, 31, 32, 24, 23, 22, 21, 20, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 18, 26, 28, 29, 30, 31, 32, 24, 23, 22, 21, 20, 19. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE02 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916664 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-_N8g4lpuepm_r?BcjztCAopUNbt2AEzZDXm357yT9kz Scale = 1:35.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-7-0 13-7-0 -0-11-0 0-11-0 6-9-8 6-9-8 13-7-0 6-9-8 14-6-0 0-11-0 1-1-05-7-51-1-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.12 0.05 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 152 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-7-0. (lb) - Max Horz 24=-135(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE03 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916665 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-SZi3H5qWO7uqT9moGhORj0MVz?17vYWjSBVdeZyT9ky Scale = 1:50.2 Sheet Back Left Option 5-2-8 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 17 16 15 14 13 12 10 9 31 30 11 4x6 3x6 3x8 3x6 3x6 3x4 3x6 4x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 3x6 2x4 5-2-8 5-2-8 5-2-8 7-0-0 1-9-8 10-2-8 3-2-8 20-5-0 10-2-8 -0-11-0 0-11-0 4-11-10 4-11-10 10-2-8 5-2-14 13-7-8 3-5-0 15-5-6 1-9-14 20-5-0 4-11-10 21-4-0 0-11-0 1-1-07-10-111-1-08.00 12 Plate Offsets (X,Y)-- [22:0-1-15,0-0-8], [25:0-1-4,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.77 0.77 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.65 0.03 (loc) 9-10 9-10 9 l/defl >622 >243 n/a L/d 240 180 n/a PLATES MT20 Weight: 197 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-17,7-9: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 30, 31 REACTIONS.All bearings 7-3-8 except (jt=length) 9=0-5-8, 11=0-3-8. (lb) - Max Horz 17=-188(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 17, 9, 14, 11 Max Grav All reactions 250 lb or less at joint(s) 14, 15, 16, 13, 11 except 17=731(LC 1), 9=828(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-640/94, 4-5=-597/103, 5-6=-722/102, 6-7=-362/79, 2-17=-263/126, 7-9=-375/113 BOT CHORD 16-17=-68/616, 15-16=-68/616, 14-15=-68/616, 13-14=-68/616, 11-13=-80/740, 10-11=-80/740, 9-10=0/649 WEBS 10-31=-21/424, 4-31=-21/423, 3-17=-674/0, 6-9=-552/50 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 9, 14, 11. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE04 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916666 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-SZi3H5qWO7uqT9moGhORj0McU?CBvi0jSBVdeZyT9ky Scale = 1:23.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 8 7 6 4x6 2x4 2x4 2x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3-3-12 3-3-12 6-7-8 3-3-12 -0-11-0 0-11-0 3-3-12 3-3-12 6-7-8 3-3-12 7-6-8 0-11-0 1-1-03-3-81-1-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.29 0.12 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 7 7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-7: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=317/0-3-8, 6=317/0-3-8 Max Horz 8=81(LC 5) Max Uplift 8=-42(LC 6), 6=-42(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-8=-266/95, 4-6=-266/95 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE05 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916667 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Pyqpimrmwk8YiTwBO6QvoRRwMot2Nan0wV_jiRyT9kw Scale = 1:73.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 3x4 3x6 3x6 4x6 3x6 3x6 3x6 32-11-0 32-11-0 -0-11-0 0-11-0 18-7-3 18-7-3 32-11-0 14-3-13 1-0-011-10-33-6-07.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.39 0.16 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 30 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 683 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 29-30: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 17-42,16-43,18-41: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 17-42, 16-43, 15-44, 14-45, 13-47, 18-41, 19-39, 20-38, 21-37 REACTIONS.All bearings 32-11-0. (lb) - Max Horz 57=316(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 30, 42, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 39, 38, 37, 36, 35, 34, 33, 32, 31 except 57=-306(LC 4), 56=-273(LC 5) Max Grav All reactions 250 lb or less at joint(s) 30, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 41, 39, 38, 37, 36, 35, 34, 33, 32, 31 except 57=376(LC 5), 42=256(LC 7), 56=259(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-57=-258/221, 2-3=-359/312, 3-4=-275/252, 4-5=-265/259, 5-6=-246/256, 6-7=-228/253, 7-8=-209/251, 13-14=-116/257, 14-15=-97/277, 15-16=-80/302, 16-17=-58/302, 17-18=-48/301, 18-19=-48/293, 19-20=-45/263 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 42, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 39, 38, 37, 36, 35, 34, 33, 32, 31 except (jt=lb) 57=306, 56=273. 12) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE05 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916667 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:19 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Pyqpimrmwk8YiTwBO6QvoRRwMot2Nan0wV_jiRyT9kw 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE06 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916668 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-LLyZ7St0SLOGyn4ZVXSNtsXHUcYDrUCJNoTqnKyT9ku Scale = 1:74.4 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 3130 5x6 3x4 3x4 5x6 5x6 5x6 3x6 35-1-0 35-1-0 16-6-12 16-6-12 35-1-0 18-6-4 36-0-0 0-11-0 2-1-1111-9-101-0-07.00 12 Plate Offsets (X,Y)-- [9:0-3-0,0-3-0], [19:0-3-0,0-3-0], [47:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.35 0.18 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.01 (loc) 29 29 30 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 699 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 28-30: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 14-45,13-46,15-44: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 14-45, 13-46, 12-47, 11-48, 10-49, 15-44, 16-43, 17-42, 18-40 REACTIONS.All bearings 35-1-0. (lb) - Max Horz 58=-299(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 44, 43, 42, 40, 39, 38, 37, 36, 35, 34, 33, 32 except 58=-149(LC 4), 30=-290(LC 5), 57=-165(LC 5), 31=-248(LC 4) Max Grav All reactions 250 lb or less at joint(s) 58, 47, 46, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 44, 43, 42, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31 except 30=336(LC 4), 45=265(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 11-12=-20/276, 12-13=-18/307, 13-14=-21/313, 14-15=-22/314, 15-16=-37/313, 16-17=-56/288, 17-18=-75/268, 27-28=-311/286 BOT CHORD 57-58=-209/251, 56-57=-209/251, 55-56=-209/251, 54-55=-209/251, 53-54=-209/251, 52-53=-209/251, 51-52=-209/251, 50-51=-209/251, 49-50=-208/250, 48-49=-208/250, 47-48=-208/250, 46-47=-208/250, 45-46=-208/250, 44-45=-208/250, 43-44=-208/250, 42-43=-208/250, 40-42=-208/250, 39-40=-208/250 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 44, 43, 42, 40, 39, 38, 37, 36, 35, 34, 33, 32 except (jt=lb) 58=149, 30=290, 57=165, 31=248.Continued on page 2 October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE06 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916668 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:21 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-LLyZ7St0SLOGyn4ZVXSNtsXHUcYDrUCJNoTqnKyT9ku NOTES-(13-14) 12) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE07 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916669 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-pXVyKotfDfW7Zwfm3EzcQ33RE0sPatVScSDOJmyT9kt Scale = 1:72.8 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 2x4 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4x6 2x4 -0-11-0 0-11-0 9-9-8 9-9-8 5-6-1011-3-37.00 12 Plate Offsets (X,Y)-- [2:0-1-7,0-0-0], [2:0-1-15,0-1-8], [3:0-0-10,0-0-0], [17:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.41 0.31 0.40 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 11 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 250 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 10-11: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 17-18. WEBS 1 Row at midpt 10-11, 9-12, 8-13, 7-14 REACTIONS.All bearings 9-9-8. (lb) - Max Horz 18=329(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 11, 12, 13, 14, 15, 16 except 18=-506(LC 4), 17=-625(LC 5) Max Grav All reactions 250 lb or less at joint(s) 11, 12, 13, 14, 15, 16 except 18=748(LC 5), 17=487(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-18=-715/493, 2-3=-320/224 BOT CHORD 17-18=-281/252 WEBS 3-17=-534/768 NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 12, 13, 14, 15, 16 except (jt=lb) 18=506, 17=625. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE08 Truss Type MONOPITCH SUPPORTED Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916670 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Hj3KY8uH_ze_B4DydxVryHcgsQG9JQ0bq6yxrDyT9ks Scale = 1:13.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 2x4 2x4 2x4 2x4 -0-11-0 0-11-0 1-11-8 1-11-8 1-0-02-1-117.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.10 0.02 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=152/1-11-8, 4=49/1-11-8 Max Horz 5=60(LC 5) Max Uplift 5=-31(LC 6), 4=-24(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE09 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916671 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-D6B4yqwXWauiQONKkMXJ1ihoWDl6n5VuIQR2w5yT9kq Scale = 1:93.7 Sheet Front Right Option -0-10-9 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 27 26 25 24 23 22 21 20 18 17 16 15 14 13 31 30 29 28 52 53 54 19 3x6 6x10 5x6 3x6 3x16 MT18HS 2x4 2x4 10x16 3x16 MT18HS 3x4 3x8 3x6 8x10 3x4 3x8 3x6 10x10 3x6 3x6 3x6 3x6 5x12 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-10-9 8-0-5 8-0-5 19-3-0 11-2-11 22-11-8 3-8-8 33-6-8 10-7-0 35-11-0 2-4-8 44-7-8 8-8-8 45-6-1 0-10-9 -0-11-0 0-11-0 5-2-11 5-2-11 11-6-6 6-3-11 19-3-0 7-8-10 22-11-8 3-8-8 24-6-8 1-7-0 28-3-0 3-8-8 33-6-8 5-3-8 39-6-7 5-11-15 44-7-8 5-1-1 1-0-012-2-121-2-14-7-212-2-127.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-8], [2:0-1-12,0-1-0], [6:0-7-0,0-1-12], [10:0-4-0,0-2-4], [30:0-0-14,0-0-15], [30:0-5-12,0-1-12], [46:0-1-8,0-0-12], [48:0-1-8,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.99 0.89 0.96 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.66 -1.36 0.30 (loc) 20-22 20-22 13 l/defl >651 >315 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 380 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 7-23: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-24,6-24: 2x4 SPF No.2, 2-27,12-13: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 6-10. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-24, 6-24, 3-27, 11-13 JOINTS 1 Brace at Jt(s): 28, 29, 30, 31 REACTIONS.All bearings 9-0-0 except (jt=length) 27=0-3-8, 19=0-3-8. (lb) - Max Horz 27=285(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 12, 27, 13, 16, 19 Max Grav All reactions 250 lb or less at joint(s) 12, 18, 17, 16, 15, 14 except 27=1911(LC 1), 13=1024(LC 1), 19=503(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-406/110, 3-5=-2729/218, 5-6=-2042/251, 6-7=-2584/287, 7-8=-2595/284, 8-9=-1598/169, 9-10=-1309/154, 10-11=-1594/141, 2-27=-396/122 BOT CHORD 26-27=-233/2276, 24-26=-171/2129, 7-22=-3/261, 20-22=-152/2503, 19-20=-191/2459, 18-19=-191/2459, 17-18=-79/1373, 16-17=-79/1373, 15-16=-79/1373, 14-15=-79/1373, 13-14=-79/1373 WEBS 5-26=0/384, 5-24=-659/196, 6-24=-1419/193, 22-24=-147/2798, 6-22=-145/2171, 9-30=-417/179, 20-30=-394/187, 20-29=0/439, 10-29=0/421, 3-27=-2485/86, 11-13=-1641/97, 18-28=-1265/131, 28-29=-1245/136, 29-30=-1206/135, 30-31=-1170/136, 8-31=-1160/133 NOTES-(14-15) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 10) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE09 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916671 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:25 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-D6B4yqwXWauiQONKkMXJ1ihoWDl6n5VuIQR2w5yT9kq NOTES-(14-15) 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 27, 13, 16, 19. 12) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 15) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss GE10 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916672 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-iIlSAAx9Hu0Z2YyXI42YavE93dGPWmm2X4BbSYyT9kp Scale = 1:38.9 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 103x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-8-4 11-8-4 6-9-137.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.23 0.12 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 131 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-8-4. (lb) - Max Horz 1=194(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 Max Grav All reactions 250 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss M01 Truss Type MONOPITCH Qty 5 Ply 1 23 Copper Run Job Reference (optional) I38916673 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-iIlSAAx9Hu0Z2YyXI42YavEB6dHsWnm2X4BbSYyT9kp Scale = 1:13.7 1 2 3 5 4 2x4 2x4 2x4 2x4 1-11-8 1-11-8 -0-11-0 0-11-0 1-11-8 1-11-8 1-0-02-1-111-10-30-3-82-1-117.00 12 Plate Offsets (X,Y)-- [4:0-1-15,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.10 0.02 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=152/0-3-8, 4=49/0-1-8 Max Horz 5=60(LC 5) Max Uplift 5=-31(LC 6), 4=-24(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss M02 Truss Type MONOPITCH Qty 6 Ply 1 23 Copper Run Job Reference (optional) I38916674 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-AUJrNWxn2B8QgiXjsnZn77nIm1ahFEaBlkw9__yT9ko Scale = 1:17.3 1 2 3 5 4 2x4 3x6 2x4 5-3-8 5-3-8 -0-11-0 0-11-0 5-3-8 5-3-8 0-9-02-6-30-3-84.00 12 Plate Offsets (X,Y)-- [4:0-1-15,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.24 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.09 0.00 (loc) 4-5 4-5 l/defl >999 >682 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=272/0-3-8, 4=195/0-1-8 Max Horz 5=75(LC 6) Max Uplift 5=-40(LC 4), 4=-29(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss M07 Truss Type MONOPITCH Qty 6 Ply 1 23 Copper Run Job Reference (optional) I38916675 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-ehtDbryPpVGHHr6vQV40fKJRrRrQ_cpL_OgiXQyT9kn Scale = 1:62.0 1 2 3 4 6 5 7 8 9 10 4x8 4x8 3x4 3x4 4x6 3x6 5-0-6 5-0-6 10-1-0 5-0-10 -0-11-0 0-11-0 5-0-6 5-0-6 10-1-0 5-0-10 5-6-1011-5-39-1-1211-5-37.00 12 Plate Offsets (X,Y)-- [4:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.47 0.53 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.31 0.22 (loc) 5-6 5-6 8 l/defl >765 >374 n/a L/d 240 180 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP 2400F 2.0E BOT CHORD 2x6 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF No.2, 2-6: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5, 3-6 REACTIONS.(lb/size)6=556/0-3-8, 8=459/0-3-8 Max Horz 6=303(LC 5) Max Uplift 8=-142(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-7=-107/367, 4-7=-107/367 WEBS 4-8=-465/147 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 5) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=142. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss PB01 Truss Type GABLE Qty 9 Ply 1 23 Copper Run Job Reference (optional) I38916676 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-ehtDbryPpVGHHr6vQV40fKJWIRyI_g8L_OgiXQyT9kn Scale = 1:31.1 2 3 4 5 6 10 9 8 1 7 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 15-0-15 15-0-15 7-6-7 7-6-7 15-0-15 7-6-7 -0-0-44-4-84-4-120-1-00-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.18 0.09 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-0-15. (lb) - Max Horz 1=-98(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6 except 9=266(LC 1), 10=310(LC 10), 8=310(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 10, 8. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss PB02 Truss Type GABLE Qty 2 Ply 1 23 Copper Run Job Reference (optional) I38916677 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-6tQboBz2aoP8v?h6zCbFCYsj1qHkj8VUD2PF3syT9km Scale = 1:12.2 2 3 4 1 5 3x4 2x4 2x4 5-3-8 5-3-8 2-7-12 2-7-12 5-3-8 2-7-12 -0-0-41-6-41-6-80-1-00-1-87.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.06 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-3-8. (lb) - Max Horz 1=-31(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss PBE01 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916678 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-a3_z0X_gK6X_X9GIXw7UklPtYEfhSbPdSi9pbJyT9kl Scale = 1:28.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 1 11 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-3-8 14-3-8 7-1-12 7-1-12 14-3-8 7-1-12 -0-0-44-1-124-2-00-1-00-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.07 0.03 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 102 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-3-8. (lb) - Max Horz 1=-92(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 2, 10, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11, 2, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 2, 10, 16, 17, 18, 14, 13, 12. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss PBE02 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916679 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-2GYLDt_I5Qfr8JrU5dejHzx3XezCB2?ngMuM7lyT9kk Scale = 1:12.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 1 5 3x4 2x4 2x4 5-3-8 5-3-8 2-7-12 2-7-12 5-3-8 2-7-12 -0-0-41-6-41-6-80-1-00-1-87.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.06 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-3-8. (lb) - Max Horz 1=-31(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T01 Truss Type COMMON Qty 3 Ply 1 23 Copper Run Job Reference (optional) I38916680 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-2GYLDt_I5Qfr8JrU5dejHzxw0er8BuCngMuM7lyT9kk Scale = 1:46.2 1 2 3 4 5 6 10 9 8 7 4x6 3x4 3x6 3x8 3x4 3x4 3x6 3x8 3x8 9-8-8 9-8-8 19-3-8 9-7-0 -0-11-0 0-11-0 5-2-5 5-2-5 9-8-8 4-6-2 14-1-14 4-5-6 19-3-8 5-1-10 1-1-07-6-111-2-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.60 0.66 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.43 0.03 (loc) 8-10 8-10 7 l/defl >999 >534 n/a L/d 240 180 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=826/0-3-8, 7=758/Mechanical Max Horz 10=189(LC 5) Max Uplift 10=-64(LC 6), 7=-30(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-315/92, 3-4=-721/116, 4-5=-721/117, 5-6=-257/66, 2-10=-342/117 BOT CHORD 8-10=-56/668, 7-8=-13/663 WEBS 4-8=-46/486, 3-10=-620/30, 5-7=-674/52 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T02 Truss Type COMMON Qty 5 Ply 1 23 Copper Run Job Reference (optional) I38916681 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-WS6kRD?wsjnimTPhfK9yqAU4b2CowOuwv0ewgByT9kj Scale = 1:46.2 1 2 3 4 8 7 6 5 3x4 4x6 5x6 3x6 3x4 2x4 3x8 4x8 9-8-8 9-8-8 16-3-8 6-7-0 5-2-5 5-2-5 9-8-8 4-6-2 16-3-8 6-7-0 1-1-07-6-113-2-08.00 12 Plate Offsets (X,Y)-- [4:0-2-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.68 0.63 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.51 0.01 (loc) 6-8 6-8 5 l/defl >940 >373 n/a L/d 240 180 n/a PLATES MT20 Weight: 66 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5,1-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=640/Mechanical, 8=640/0-3-8 Max Horz 8=203(LC 5) Max Uplift 5=-23(LC 6), 8=-26(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-292/59, 2-3=-529/111, 3-4=-557/94, 4-5=-594/69, 1-8=-257/61 BOT CHORD 6-8=-83/528 WEBS 3-6=0/292, 4-6=0/367, 2-8=-456/53 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 8. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T03 Truss Type COMMON Qty 2 Ply 1 23 Copper Run Job Reference (optional) I38916682 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-?eg6eZ0Yd1vZOd_tC2gBMO0G1SW4fvf48gNTCeyT9ki Scale = 1:46.2 1 2 3 4 8 7 6 5 9 10 3x4 4x6 3x8 3x4 4x6 5x8 2x4 3x6 3x6 9-8-8 9-8-8 11-0-0 1-3-8 11-3-8 0-3-8 5-2-5 5-2-5 9-8-8 4-6-3 11-3-8 1-7-0 1-1-07-6-115-8-120-9-46-6-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.63 0.69 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.48 0.01 (loc) 7-8 7-8 10 l/defl >697 >277 n/a L/d 240 180 n/a PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-8,4-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=443/0-3-8, 10=422/0-1-8 Max Horz 8=183(LC 6) Max Uplift 10=-84(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-260/57 BOT CHORD 7-8=-117/301 WEBS 2-7=-261/161, 4-7=-8/492, 4-10=-423/91 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T06 Truss Type COMMON Qty 5 Ply 1 23 Copper Run Job Reference (optional) I38916683 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-?eg6eZ0Yd1vZOd_tC2gBMO0CjSS9fox48gNTCeyT9ki Scale = 1:72.8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 1017 3x6 5x6 3x6 3x4 3x6 3x6 4x6 3x8 3x6 3x4 3x6 5x6 10x10 3x8 8-5-6 8-5-6 16-6-12 8-1-6 24-8-2 8-1-6 35-1-0 10-4-14 8-5-6 8-5-6 16-6-12 8-1-6 22-7-11 6-0-15 24-8-2 2-0-7 29-10-15 5-2-13 35-1-0 5-2-1 36-0-0 0-11-0 2-1-1111-9-101-0-07.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [8:0-1-12,0-1-0], [10:Edge,0-2-8], [15:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.84 0.94 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.74 0.09 (loc) 10-11 10-11 10 l/defl >999 >566 n/a L/d 240 180 n/a PLATES MT20 Weight: 153 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-13,4-13,6-13: 2x4 SPF No.2, 1-16,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 11-13. WEBS 1 Row at midpt 2-13, 6-13, 7-10 REACTIONS.(lb/size)16=1540/0-3-8, 10=1591/0-3-8 Max Horz 16=-299(LC 4) Max Uplift 16=-57(LC 6), 10=-99(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1929/164, 2-4=-1545/226, 4-6=-1539/222, 6-7=-2103/183, 7-8=-476/68, 1-16=-1471/132, 8-10=-434/108 BOT CHORD 15-16=-247/319, 13-15=-48/1571, 11-13=0/1767, 10-11=-58/1772 WEBS 2-13=-524/161, 4-13=-78/977, 6-13=-744/157, 6-11=0/371, 1-15=-13/1500, 7-10=-1788/127 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T06A Truss Type COMMON Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916684 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-TrEUrv1AOL1Q?mZ3mlBQvbZNRroOOEjDMK70k4yT9kh Scale = 1:72.2 1 2 3 4 5 6 7 8 15 14 13 12 11 10 916 3x6 5x6 3x6 3x4 3x6 3x6 4x6 3x8 3x6 3x4 3x6 5x6 4x8 3x6 3x8 8-5-6 8-5-6 16-6-12 8-1-6 24-8-2 8-1-6 35-1-0 10-4-14 8-5-6 8-5-6 16-6-12 8-1-6 22-7-11 6-0-15 24-8-2 2-0-7 29-10-15 5-2-13 35-1-0 5-2-1 2-1-1111-9-101-0-07.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [14:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.85 0.94 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.74 0.09 (loc) 9-10 9-10 9 l/defl >999 >566 n/a L/d 240 180 n/a PLATES MT20 Weight: 152 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-12,4-12,6-12: 2x4 SPF No.2, 1-15,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 10-12. WEBS 1 Row at midpt 2-12, 6-12, 7-9 REACTIONS.(lb/size)15=1541/0-3-8, 9=1526/0-3-8 Max Horz 15=-289(LC 4) Max Uplift 15=-57(LC 6), 9=-65(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1930/164, 2-4=-1547/226, 4-6=-1540/223, 6-7=-2108/184, 7-8=-407/39, 1-15=-1472/132, 8-9=-321/55 BOT CHORD 14-15=-254/309, 12-14=-58/1572, 10-12=-5/1770, 9-10=-88/1785 WEBS 2-12=-524/161, 4-12=-78/978, 6-12=-746/157, 6-10=0/374, 1-14=-13/1501, 7-9=-1868/158 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T07 Truss Type COMMON Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916685 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-x1os3F2o9e9Hdw8FKTifRp6aOFDn7geMb_saGWyT9kg Scale = 1:71.7 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10171819 3x6 4x6 3x6 3x16 MT18HS3x4 3x6 3x6 3x8 3x6 3x6 3x4 4x6 3x6 3x8 3x6 8-0-5 8-0-5 18-7-3 10-6-14 25-9-6 7-2-3 32-11-0 7-1-10 -0-11-0 0-11-0 5-2-11 5-2-11 11-6-7 6-3-11 18-7-3 7-0-13 25-9-6 7-2-3 32-11-0 7-1-10 1-0-011-10-33-6-07.00 12 Plate Offsets (X,Y)-- [9:Edge,0-1-12], [11:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.70 0.61 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.42 -0.79 0.06 (loc) 13-15 13-15 10 l/defl >931 >495 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 142 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 10-12: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-13: 2x4 SPF No.2, 9-10,2-16: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-14 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-13, 7-13, 3-16 REACTIONS.(lb/size)10=1481/0-3-8, 16=1532/0-3-8 Max Horz 16=316(LC 5) Max Uplift 10=-46(LC 7), 16=-97(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-349/99, 3-5=-2081/185, 5-6=-1389/214, 6-7=-1394/214, 7-9=-1476/153, 9-10=-1418/122, 2-16=-359/118 BOT CHORD 15-16=-155/1763, 13-15=-74/1543, 11-13=0/1198 WEBS 5-15=0/443, 5-13=-663/186, 6-13=-87/899, 7-11=-324/90, 9-11=-16/1280, 3-16=-1903/65 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 16. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T07A Truss Type COMMON Qty 4 Ply 1 23 Copper Run Job Reference (optional) I38916686 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-PDMEGa2RwyH8F4jSuADu_0emVfZ2s61Wqec7pyyT9kf Scale = 1:73.8 1 2 3 4 5 6 7 8 9 10 20 19 15 14 13 12 11 18 17 16 2122 3x6 4x6 3x6 3x4 2x4 3x4 3x4 3x8 5x12 3x6 3x6 3x4 4x6 5x6 5x12 3x6 2x4 2x4 4x8 2-3-8 2-3-8 8-0-5 5-8-13 12-5-8 4-5-3 18-7-3 6-1-11 25-9-6 7-2-3 32-11-0 7-1-10 -0-11-0 0-11-0 2-3-8 2-3-8 5-2-11 2-11-3 11-6-7 6-3-11 12-5-8 0-11-1 18-7-3 6-1-11 25-9-6 7-2-3 32-11-0 7-1-10 1-0-011-10-33-6-00-8-07.00 12 Plate Offsets (X,Y)-- [2:0-2-9,0-2-8], [10:Edge,0-1-12], [12:0-2-8,0-1-8], [16:0-3-8,0-0-0], [18:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.68 0.61 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.29 0.13 (loc) 12-14 12-14 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 154 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-14: 2x4 SPF No.2, 10-11,2-20: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-5 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-14, 6-14 REACTIONS.(lb/size)20=1460/0-3-8, 11=1434/0-3-8 Max Horz 20=316(LC 5) Max Uplift 20=-97(LC 6), 11=-47(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2317/137, 3-4=-2285/200, 4-6=-2178/211, 6-7=-1289/226, 7-8=-1302/219, 8-10=-1433/152, 10-11=-1381/121, 2-20=-1428/134 BOT CHORD 12-14=0/1161, 17-18=-207/2028, 16-17=-57/1539 WEBS 4-17=-348/174, 6-17=-54/471, 7-14=-110/848, 8-14=-291/142, 8-12=-260/99, 10-12=-15/1244, 6-16=0/294, 2-18=-149/1868, 6-14=-851/182, 14-16=-60/1500 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 11. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T08 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916687 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-LcT?hG4hSZXsUOtq?bGM3Rk4vTF4K2npHy5EtryT9kd Scale = 1:89.4 Sheet Front Right Option -2-11-15 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 23 22 15 14 13 18 17 16 21 20 19 25 24 26 27 49 3x6 5x6 3x6 2x4 2x4 2x4 3x4 8x8 10x10 3x4 3x4 3x8 6x16 5x8 2x4 4x10 4x6 5x12 2x4 2x4 5x8 2x4 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4-10-9 1-8-152-11-15 2-3-8 2-3-8 8-0-5 5-8-13 12-5-8 4-5-3 19-3-0 6-9-8 22-11-8 3-8-8 30-1-8 7-2-0 35-11-0 5-9-8 38-10-15 2-11-15 -0-11-0 0-11-0 2-3-8 2-3-8 5-2-11 2-11-3 11-6-6 6-3-11 12-5-8 0-11-2 18-7-3 6-1-11 19-3-0 0-7-13 22-11-8 3-8-8 24-6-8 1-7-0 29-11-5 5-4-13 35-11-0 5-11-11 36-10-0 0-11-0 1-0-012-2-121-0-04-7-212-2-127.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [7:0-5-8,0-2-0], [9:0-2-8,0-1-7], [9:0-3-0,0-1-12], [13:Edge,0-8-0], [13:0-1-12,0-0-0], [15:0-2-12,Edge], [19:0-3-4,0-0-0], [21:0-5-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.82 0.64 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.41 0.23 (loc) 19-20 17-18 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 316 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-17,7-17: 2x4 SPF No.2, 2-23,11-13: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-0 max.): 7-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-17, 7-17 JOINTS 1 Brace at Jt(s): 25, 26 REACTIONS.(lb/size)23=1544/0-3-8, 13=1514/3-3-8 Max Horz 23=276(LC 5) Max Uplift 23=-96(LC 6), 13=-66(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2469/184, 3-4=-2442/249, 4-6=-2339/241, 6-7=-1398/240, 7-8=-1800/229, 8-9=-1729/230, 9-10=-2111/296, 10-11=-2112/180, 2-23=-1512/152, 11-13=-1458/166 BOT CHORD 14-15=0/1456, 13-14=-30/268, 20-21=-297/2162, 19-20=-142/1687 WEBS 4-20=-338/179, 6-20=-59/462, 6-17=-893/199, 7-17=-747/45, 15-17=-18/1782, 7-24=0/1290, 15-24=0/1030, 15-26=-89/615, 9-26=-90/620, 10-14=-352/181, 11-14=-19/1490, 9-27=-133/304, 14-27=-124/448, 6-19=0/306, 2-21=-225/1995, 17-19=-144/1638, 24-25=0/303 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 13. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T09 Truss Type PIGGYBACK BASE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916688 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-H_bl6y5x_Bnajh1D70Iq8spOnGv8oyF6lGaLykyT9kb Scale = 1:86.4 1 2 3 4 5 6 7 8 9 10 11 12 23 22 15 14 13 18 17 16 21 20 19 24 25 26 3x6 5x6 2x4 2x4 2x4 2x4 8x10 10x10 3x4 3x4 3x8 6x16 5x8 2x4 4x10 4x6 5x12 2x4 2x4 5x8 2-3-8 2-3-8 8-0-5 5-8-13 12-5-8 4-5-3 19-3-0 6-9-8 22-11-8 3-8-8 30-1-8 7-2-0 35-11-0 5-9-8 -0-11-0 0-11-0 2-3-8 2-3-8 5-2-11 2-11-3 11-6-6 6-3-11 12-5-8 0-11-2 19-3-0 6-9-8 22-11-8 3-8-8 24-6-8 1-7-0 29-11-5 5-4-13 35-11-0 5-11-11 36-10-0 0-11-0 1-0-012-2-121-0-04-7-212-2-127.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [7:0-5-12,0-2-0], [9:0-3-0,0-1-12], [13:Edge,0-8-0], [13:0-1-12,0-0-0], [15:0-2-12,0-3-4], [17:0-7-8,0-3-0], [19:0-3-4,0-0-0], [21:0-5-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.85 0.66 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.24 -0.51 0.23 (loc) 14-15 14-15 13 l/defl >999 >844 n/a L/d 240 180 n/a PLATES MT20 Weight: 189 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-17,7-17: 2x4 SPF No.2, 2-23,11-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-2 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-0 max.): 7-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 16-17. WEBS 1 Row at midpt 6-17, 7-17 REACTIONS.(lb/size)23=1582/0-3-8, 13=1606/0-3-8 Max Horz 23=276(LC 5) Max Uplift 23=-96(LC 6), 13=-66(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2535/184, 3-4=-2508/249, 4-6=-2411/241, 6-7=-1467/240, 7-8=-1757/232, 8-9=-1768/230, 9-10=-2275/296, 10-11=-2276/180, 2-23=-1548/152, 11-13=-1562/166 BOT CHORD 14-15=0/1645, 13-14=-30/259, 20-21=-297/2223, 19-20=-142/1750 WEBS 4-20=-337/179, 6-20=-59/460, 6-17=-898/199, 7-17=-851/45, 15-17=-17/1915, 7-15=0/1357, 9-15=-98/632, 10-14=-351/181, 11-14=-19/1642, 9-14=-126/458, 6-19=0/312, 2-21=-225/2049, 17-19=-144/1700 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 13. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T09A Truss Type PIGGYBACK BASE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916689 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-H_bl6y5x_Bnajh1D70Iq8spOVGvjowd6lGaLykyT9kb Scale = 1:82.6 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 3x6 5x6 3x16 MT18HS 2x4 2x4 8x10 10x10 3x4 3x6 3x6 5x12 8x10 2x4 4x10 10x10 8-0-5 8-0-5 19-3-0 11-2-11 22-11-8 3-8-8 30-1-8 7-2-0 35-11-0 5-9-8 -0-11-0 0-11-0 5-2-11 5-2-11 11-6-6 6-3-11 19-3-0 7-8-10 22-11-8 3-8-8 24-6-8 1-7-0 29-11-5 5-4-13 35-11-0 5-11-11 36-10-0 0-11-0 1-0-012-2-121-0-04-7-212-2-127.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-8], [2:0-1-12,0-1-0], [6:0-9-0,0-1-12], [8:0-3-0,0-1-12], [12:Edge,0-8-0], [12:0-1-12,0-0-0], [14:0-2-12,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.87 0.69 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.54 -1.05 0.18 (loc) 16-18 16-18 12 l/defl >787 >408 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 176 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 17-19,15-17: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 5-16,6-16: 2x4 SPF No.2, 2-19,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc purlins, except end verticals, and 2-0-0 oc purlins (4-0-14 max.): 6-8. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-16, 6-16, 3-19 REACTIONS.(lb/size)12=1655/0-3-8, 19=1666/0-3-8 Max Horz 19=276(LC 5) Max Uplift 12=-66(LC 7), 19=-96(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-365/107, 3-5=-2314/195, 5-6=-1585/226, 6-7=-1843/230, 7-8=-1852/229, 8-9=-2353/295, 9-10=-2355/179, 2-19=-372/122, 10-12=-1610/166 BOT CHORD 18-19=-227/1945, 16-18=-152/1752, 13-14=0/1720, 12-13=-30/264 WEBS 5-18=0/428, 5-16=-688/196, 6-16=-858/70, 14-16=-7/2113, 6-14=0/1364, 8-14=-95/673, 9-13=-350/181, 3-19=-2115/66, 10-13=-18/1706, 8-13=-126/445 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 19. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T10 Truss Type PIGGYBACK BASE Qty 9 Ply 1 23 Copper Run Job Reference (optional) I38916690 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-ENjVXe7BWo1Hz?AcERKIEHujP4coGnjOCa3R0cyT9kZ Scale = 1:82.8 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 112021 3x6 5x8 5x8 3x6 3x16 MT18HS 6x16 3x6 3x6 6x8 4x8 6x6 2x4 4x8 3x4 3x12 5x6 3x6 6x10 8-1-8 8-1-8 15-11-8 7-10-0 18-10-5 2-10-13 26-4-12 7-6-7 33-11-3 7-6-7 44-7-8 10-8-5 -0-11-0 0-11-0 8-1-8 8-1-8 15-11-8 7-10-0 18-10-5 2-10-13 26-4-12 7-6-7 33-11-3 7-6-7 39-6-6 5-7-3 44-7-8 5-1-2 1-0-012-0-01-2-14-7-27-4-147.00 12 3.56 12 Plate Offsets (X,Y)-- [2:0-4-10,0-3-0], [6:0-4-8,0-2-0], [8:0-5-0,0-1-12], [15:0-2-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.91 0.59 0.96 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.36 -0.90 0.41 (loc) 16-18 16-18 11 l/defl >999 >591 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 181 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 8-10: 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 10-11: 2x4 SPF-S Stud, 2-19: 2x6 SPF No.2, 2-18: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (3-11-5 max.): 6-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-15, 6-14, 9-11 REACTIONS.(lb/size)11=1933/Mechanical, 19=1953/0-5-8 Max Horz 19=282(LC 5) Max Uplift 11=-26(LC 7), 19=-98(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4794/405, 3-5=-4394/401, 5-6=-3540/387, 6-7=-3035/350, 7-8=-3035/350, 8-9=-2740/272, 9-10=-354/29, 10-11=-276/40, 2-19=-2028/268 BOT CHORD 18-19=-331/585, 16-18=-410/4220, 15-16=-268/3665, 14-15=-216/3020, 12-14=-63/2293, 11-12=-162/2238 WEBS 3-16=-366/191, 5-16=-77/1291, 5-15=-1422/223, 6-15=-127/1508, 6-14=-256/248, 7-14=-515/218, 8-14=-216/1100, 8-12=0/335, 9-11=-2536/264, 2-18=-147/3549 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Refer to girder(s) for truss to truss connections. 9) Bearing at joint(s) 19 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 19. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T11 Truss Type COMMON Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916691 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-ENjVXe7BWo1Hz?AcERKIEHut24jpG0DOCa3R0cyT9kZ Scale = 1:22.4 1 2 3 4 7 6 5 4x6 3x4 3x4 3x4 2x4 3x4 3-3-12 3-3-12 6-7-8 3-3-12 -0-11-0 0-11-0 3-3-12 3-3-12 6-7-8 3-3-12 1-1-03-3-81-1-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.29 0.14 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=322/0-3-8, 5=248/0-3-8 Max Horz 7=89(LC 5) Max Uplift 7=-42(LC 6), 5=-9(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-269/94 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T12 Truss Type COMMON Qty 2 Ply 1 23 Copper Run Job Reference (optional) I38916692 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-iZHuk_8qH698b9loo8sXmVR2wU3v?TUYRDo?Z2yT9kY Scale = 1:22.4 1 2 3 6 5 4 3x4 4x6 3x4 3x4 3x4 2x4 3-3-12 3-3-12 6-7-8 3-3-12 3-3-12 3-3-12 6-7-8 3-3-12 1-1-03-3-81-1-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.29 0.15 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=253/0-3-8, 4=253/0-3-8 Max Horz 6=-78(LC 4) Max Uplift 6=-8(LC 6), 4=-8(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss T12A Truss Type COMMON Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916693 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-iZHuk_8qH698b9loo8sXmVR3AU3G?TWYRDo?Z2yT9kY Scale = 1:22.4 1 2 3 4 8 7 6 5 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-8-4 0-8-4 3-3-12 2-7-8 6-7-8 3-3-12 3-3-12 3-3-12 6-7-8 3-3-12 1-1-03-3-81-1-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.19 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-8,4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=218/0-3-8, 7=288/0-5-8 Max Horz 7=-78(LC 4) Max Uplift 5=-8(LC 7), 7=-23(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 23 Copper Run Job Reference (optional) I38916694 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-AmqGyK8S1PH?CJK_MsNmJi_8AtKxkmRhgtYY5VyT9kX Scale: 1/4"=1' 1 2 3 4 5 11 10 9 8 7 61213141516171819 4x8 4x6 12x12 3x8 5x6 3x8 8x8 10x10 4x8 8x8 0-0-6 0-0-6 4-10-0 4-9-10 9-4-8 4-6-8 14-4-0 4-11-8 19-7-0 5-3-0 4-10-0 4-10-0 9-4-8 4-6-8 14-4-0 4-11-8 19-7-0 5-3-0 1-7-117-10-111-1-08.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [5:0-5-4,0-2-4], [6:0-3-0,0-2-0], [7:0-3-8,0-4-0], [10:0-3-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.64 0.48 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.21 0.03 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 343 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 2-10,2-8,4-8,4-7: 2x4 SPF-S Stud, 5-6: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=9309/0-2-12, 6=9442/0-5-8 Max Horz 11=-189(LC 11) Max Uplift 11=-199(LC 5), 6=-204(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-9983/241, 2-3=-7948/257, 3-4=-7957/254, 4-5=-10983/261, 1-11=-7831/193, 5-6=-7459/192 BOT CHORD 10-11=-181/567, 8-10=-178/8228, 7-8=-150/9058, 6-7=-51/2053 WEBS 2-10=-37/2562, 2-8=-2352/144, 3-8=-201/8439, 4-8=-3272/169, 4-7=-38/3540, 5-7=-113/7115, 1-10=-130/7964 NOTES-(11-12) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 11. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=199, 6=204. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1913 lb down and 38 lb up at 1-9-12, 1913 lb down and 38 lb up at 3-9-12, 1913 lb down and 38 lb up at 5-9-12, 1913 lb down and 38 lb up at 7-9-12, 1913 lb down and 38 lb up at 9-9-12, 1913 lb down and 38 lb up at 11-9-12, 1913 lb down and 38 lb up at 13-9-12, and 1913 lb down and 38 lb up at 15-9-12, and 1913 lb down and 38 lb up at 17-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 23 Copper Run Job Reference (optional) I38916694 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:44 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-AmqGyK8S1PH?CJK_MsNmJi_8AtKxkmRhgtYY5VyT9kX 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-11=-20 Concentrated Loads (lb) Vert: 9=-1913(F) 12=-1913(F) 13=-1913(F) 14=-1913(F) 15=-1913(F) 16=-1913(F) 17=-1913(F) 18=-1913(F) 19=-1913(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss TG03 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 2 23 Copper Run Job Reference (optional) I38916695 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-eyOe9f94ojQsqTvAvZu?rwWHDHfDTNyruXH6dxyT9kW Scale = 1:17.0 1 2 3 5 4 6 7 8 9 3x4 10x10 8x8 5x6 3x8 2x4 3-1-1 3-1-1 5-3-8 2-2-8 7-7-8 2-4-0 3-1-1 3-1-1 5-3-8 2-2-8 7-7-8 2-4-0 0-9-02-6-30-5-84.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-14], [4:Edge,0-3-4], [4:0-1-12,0-0-0], [6:0-0-0,0-1-12], [7:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.75 0.54 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.23 0.00 (loc) 1-5 1-5 4 l/defl >975 >386 n/a L/d 240 180 n/a PLATES MT20 Weight: 64 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-5: 2x4 SPF 2100F 1.8E WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. Except: 10-0-0 oc bracing: 3-6 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=830/0-3-8, 1=1839/0-3-8 Max Horz 1=62(LC 4) Max Uplift 4=-30(LC 5), 1=-98(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-753/67, 2-3=-538/33 BOT CHORD 1-5=-76/708 WEBS 2-5=-254/71 NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 1. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 746 lb down and 38 lb up at 0-1-12, and 738 lb down and 42 lb up at 2-4-12, and 738 lb down and 42 lb up at 4-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) StandardContinued on page 2 October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss TG03 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 2 23 Copper Run Job Reference (optional) I38916695 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:45 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-eyOe9f94ojQsqTvAvZu?rwWHDHfDTNyruXH6dxyT9kW LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 1-4=-20 Concentrated Loads (lb) Vert: 1=-746(B) 8=-738(B) 9=-738(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V01 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916696 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-68y0N?AiZ1YjScUNTHPEO73YWh2xCpR_7B1f9NyT9kV Scale = 1:31.3 1 2 3 5 463x6 2x4 2x4 2x4 2x4 9-4-13 9-4-13 0-0-45-5-137.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.33 0.32 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=156/9-4-13, 4=170/9-4-13, 5=475/9-4-13 Max Horz 1=155(LC 5) Max Uplift 4=-17(LC 5), 5=-95(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-326/143 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V02 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916697 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-68y0N?AiZ1YjScUNTHPEO73X9h36Cq__7B1f9NyT9kV Scale: 1/2"=1' 1 2 3 5 42x4 2x4 2x4 2x4 2x4 7-1-6 7-1-6 0-0-44-1-137.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.41 0.24 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=65/7-1-6, 4=125/7-1-6, 5=339/7-1-6 Max Horz 1=116(LC 5) Max Uplift 1=-5(LC 4), 4=-13(LC 5), 5=-74(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-254/137 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V03 Truss Type Valley Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916698 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:48 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-2X4nnhCy5eoRhwelbhRiTY8xUVntgkmHaVWmEGyT9kT Scale = 1:16.9 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 4-9-15 4-9-15 0-0-42-9-137.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.17 0.10 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=57/4-9-8, 4=72/4-9-8, 5=217/4-9-8 Max Horz 1=76(LC 5) Max Uplift 4=-9(LC 5), 5=-47(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V04 Truss Type Valley Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916699 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Xje9?1CasywIJ4Dy8Pyx0mh6iu7IPBSQp9FJmiyT9kS Scale = 1:10.3 1 2 3 2x4 2x4 2x4 2-6-8 2-6-8 0-0-41-5-137.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.14 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=82/2-6-2, 3=82/2-6-2 Max Horz 1=36(LC 5) Max Uplift 1=-2(LC 6), 3=-12(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V05 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916700 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Xje9?1CasywIJ4Dy8Pyx0mh4Bu4VPAeQp9FJmiyT9kS Scale = 1:34.6 1 2 3 4 5 8 7 63x6 3x6 3x6 2x4 2x4 2x4 5x6 2x4 16-2-12 16-2-12 8-1-6 8-1-6 16-2-12 8-1-6 0-0-45-4-150-0-48.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.30 0.26 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-6: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-2-12. (lb) - Max Horz 1=119(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=363(LC 10), 6=358(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-260/139, 4-6=-257/136 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V06 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916701 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-?wCXCNDDdF29wEo8i6UAYzEE3ITQ8dUa2p?sI9yT9kR Scale = 1:28.1 1 2 3 4 5 8 7 63x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 13-2-12 13-2-12 6-7-6 6-7-6 13-2-12 6-7-6 0-0-44-4-150-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.09 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-2-12. (lb) - Max Horz 1=-96(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=264(LC 1), 8=301(LC 10), 6=301(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 6. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V07 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916702 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-T6mvQjErOZA0YOMKGq?P5BmQRilCt5zjHTkQrbyT9kQ Scale = 1:21.7 1 2 3 4 3x8 4x6 3x8 2x4 9-9-14 9-9-14 4-10-15 4-10-15 9-9-14 4-10-15 0-0-43-3-50-0-48.00 12 Plate Offsets (X,Y)-- [1:0-0-3,Edge], [2:0-4-0,0-1-8], [3:0-3-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.32 0.38 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=174/9-9-14, 3=174/9-9-14, 4=382/9-9-14 Max Horz 1=-71(LC 4) Max Uplift 1=-17(LC 6), 3=-23(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V08 Truss Type Valley Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916703 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:52 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-xIJHd3FT9tItAYxXqXWedOJb067mcYntV7UzN1yT9kP Scale = 1:15.4 1 2 3 4 2x4 3x4 2x4 2x4 6-3-8 6-3-8 6-3-14 0-0-6 3-1-15 3-1-15 6-3-14 3-1-15 0-0-42-1-50-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.26 0.16 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=120/6-3-2, 3=120/6-3-2, 4=209/6-3-2 Max Horz 1=-44(LC 4) Max Uplift 1=-18(LC 6), 3=-21(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V09 Truss Type Valley Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916704 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:vHWRLGPwmLXi7LFzdd1EYfyUCZ5-PVtgrOF5wAQknhWjNF1tAcsqHWU2L_S0knDXvTyT9kO Scale = 1:7.4 1 2 3 2x4 2x4 2x4 2-9-8 2-9-8 2-9-14 0-0-6 1-4-15 1-4-15 2-9-14 1-4-15 0-0-40-11-50-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.04 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-14 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=85/2-9-2, 3=85/2-9-2 Max Horz 1=-17(LC 4) Max Uplift 1=-4(LC 6), 3=-4(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V10 Truss Type Valley Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916705 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-PVtgrOF5wAQknhWjNF1tAcsmAWTgL_S0knDXvTyT9kO Scale = 1:7.7 1 2 3 3x4 2x4 2x4 4-0-6 4-0-6 0-0-41-0-23.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.30 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=120/3-11-6, 3=120/3-11-6 Max Horz 1=25(LC 5) Max Uplift 1=-9(LC 4), 3=-12(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V11 Truss Type Valley Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916706 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-thR22kGjhUYaPr5vxyY6jpOwmvo44Ru9zRz4RwyT9kN Scale = 1:17.0 1 2 3 5 4 3x4 2x4 2x4 2x4 2x4 9-4-6 9-4-6 0-0-42-4-23.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.24 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=143/9-3-6, 4=116/9-3-6, 5=408/9-3-6 Max Horz 1=68(LC 5) Max Uplift 1=-4(LC 4), 4=-9(LC 6), 5=-45(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-294/146 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 23_Copper_Run Truss V12 Truss Type GABLE Qty 1 Ply 1 23 Copper Run Job Reference (optional) I38916707 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Oct 15 12:56:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:xzqRsvhv5m7IxCqij8djlvzWP84-Lt?QF4HLSogR1?g5Vg3LF1x7uJAUpu2JB5jd_MyT9kM Scale = 1:24.7 Sheet Front Left Option 3-9-0 1 Ply 7/16OSB81 2 3 4 5 9 8 7 63x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3-8-0 3-9-0 3-9-0 3-9-0 3-9-0 3-9-0 14-8-6 10-11-6 0-0-43-8-23.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.16 0.10 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-8-6. (lb) - Max Horz 1=109(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 6, 7, 8, 9 Max Grav All reactions 250 lb or less at joint(s) 1, 6, 9 except 7=357(LC 1), 8=274(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-7=-268/111 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) All bearings are assumed to be SPF No.2 crushing capacity of 425 psi. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7, 8, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 16,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths