Loading...
HomeMy WebLinkAboutCARMEL REHABILITATION HOSPITAL SITE ONLYPage 1 of 2 Submittal Original Submittal for Prior Approval Project: CARMEL REHABILITATION HOSPITAL Date: 7/16/2019 1 Copy of Submittals is Attached 11/12/19 Page 2 of 2 To: Submittal Source Quote: TLAP001318 Entry Date: 7/16/2019 Project: CARMEL REHABILITATION HOSPITAL Qty Type Mfg Description **SITE** 13 SAHS GE LIGHTING EALS-03-XX-F4-AH-7-40-N-D-D1-XX- (TYPE IV HSS) 12 SAHS GE LIGHTING ELS-EAL-RBL-BLCK 12 SAHS VALMONT INDUSTRIES INC. (STEEL) DS330-400Q200-D1-FP-XX-FBC-AB 6 SB2 GE LIGHTING EALS-03-VOLT-D5-SH-7-40-N-D-D1-XX (TYPE V) 6 SB2 VALMONT INDUSTRIES INC. (STEEL) DS330-400Q200-D2-FP-XX-FBC-AB 6 SC GE LIGHTING EALS-03-XX-F4-AH-7-40-N-D-D1-XX (TYPE IV) 6 SC VALMONT INDUSTRIES INC. (STEEL) DS330-400Q200-D1-FP-XX-FBC-AB 3 WA GE LIGHTING EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH 1. PILLOW SWITCH PROVIDED BY OTHERS. 2. NIGHT LIGHT CONTROL NOT INCLUDED. 3. CROSSHATCHED TYPE ARE ON LIFE SAFETY GENSET. EMERG BATTERIES AND OR GTD'S ARE NOT INCLUDED. 11/12/19 GE Evolve ™ LED Area Lighting EALS-03 & EALP-03 Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCK (TYPE IV HSS) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 Applications • Site and area light applications such as parking lots, retail exteriors, commercial exteriors, roadways and other general lighting applications Housing • Slim architectural design incorporates an integral heat sink and light engine, ensuring maximum heat transfer, and long LED life. • Die cast aluminum housing • 3G vibration per ANSI C136.31-2010 LED & Optical Assembly • LM-79 tests and reports in accordance with IESNA standards • Upward Light Output Ratio (ULOR) = 0 (horizontal orientation) • 70CRI at 3000K, 4000K and 5000K • Distributions: II, III, IV, V Lumen Maintenance • Projected Lxx per IES TM-21 at 25 °C for reference: Ratings • cUL Listed • UL 1598 Listed Suitable for Wet Locations • IP65 optical enclosure per ANSI C136.25-2013 • Operating Temperature –40°C to +40°C (maximum of +35°C for 570W) • California Title 24 compliant (w/ “H” motion sensor option) Mounting Option C1: Integral Slipfitter for 1.25”-2” Pipe (1.66 in. OD-2.378 in. OD) supplied with leads. +/- 5 deg adjustment for leveling. Option D1: Universal Mounting Arm, fitted for round or square pole mounting supplied with 16/3 3ft cable. Option K1: Knuckle Slipfitter for 1.9 in.-2.3 in. OD Tenon with leads. Restricted aiming angle 0° to +45°. Option S1: Knuckle Slipfitter for 2.3 in.- 3.0 in OD Tenon with leads. Restricted aiming angle 0° to +45°. Option V1: Knuckle Wall Mount with leads. Restricted aiming angle 0° to +45°. Finish • Corrosion resistant polyester powder paint, minimum thickness 2.0 mil. • Standard colors: Black, Dark Bronze, Aluminum, Gray & White. • RAL & custom colors available. • Optional coastal finish available. Electrical • 120-277 VAC and 347-480 VAC available. • System power factor is >90% and THD <20%. • ANSI C136.41 7-pin dimming receptacle, standard. • ANSI photo electric sensors (PE) available for all voltages. • LightGrid™ compatible. • Dimming/Occupancy: – Standard: 0-10V; Optional: DALI (120-277V, excluding 400 watts and above) – Externally wired 0-10V dimming (optional) – DALI digital dimming. Contact manufacturer for availability. – Standalone dimming occupancy sensor with ambient light sensor, option code “H”. – Daintree occupancy sensor available. • Surge Protection tested per ANSI C136.2-2015. – 6kV/3kA “Basic” surge protection, standard. – 10kV/5kA “Enhanced” surge protection optional. Warranty • 5 Year Standard Accessories • Photoelectric Controls (see page 10) • Light Shields (see Data Sheet OLP 3120 Shielding for EAL Area Light Fixtures) The EAL Area Light luminaires offer a wide range of optical patterns, color temperatures, lumen packages, and mounting configurations to optimize area light applications, as well as provide versatility in lighting design within the same form-factor. They are ideal for commercial property site-lighting applications such as retail and commercial exteriors. The EALS (standard) area light has a lumen range from 7,500-30,000 lumens. The EALP (premium) offers a similar lumen range of 25,000 to 70,000 lumens but with higher LPW and better lumen maintenance. Both the EALS-03 and EALP-03 feature our innovative, highly flexible Universal Mounting Arm option, which provides installers the ability to mount the EAL fixtures on both round and square poles of multiple sizes. In addition, it features both in-line and offset bolt patterns which enable it to easily be affixed to the majority of the bolt patterns one would encounter in the field. Product Features Note: 1) Projected Lxx based on LM80 (10,000 hour testing). 2) DOE Lighting Facts Verification Testing Tolerances apply to initial luminous flux and lumen maintenance measurements J5, K2, K3, K4, K5 L97 L96 L94 L2, L3, L4, L5, M2, M3, M4, M5 L97 L96 L94 J2, J3, J4, N2, N3, N4, N5 L94 L91 L84 P2, P3, P4, P5, Q2, Q3, Q4, Q5 L94 L91 L84 EALP03 Optical code 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours C2, C3, C4, C5, D2, D3, D4, D5 L95 L92 L86 F5, H2, H3, H4, H5 L95 L92 L86 F2, F3, F4, J2, J3, J4, J5 L94 L89 L81 K2, K3, K4, K5 L94 L89 L81 EALS03 Optical code 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours 10 1.02 20 1.01 25 1.00 30 0.99 40 0.98 Ambient Temp (°C ) Initial Flux Factor Lumen Ambient Temperature Factors: DLC Standard qualified models available. Please refer to http://www.designlights.org/QPL for complete information. DLC Premium qualified models available. Please refer to http://www.designlights.org/QPL for complete information. Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCK (TYPE IV HSS) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 E A L S 0 3 7 ______ __ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ PROD. ID VOLTAGE OPTICAL CODE CRI 0 = 120-277* 1 = 120 2 = 208 3 = 240 4 = 277 5 = 480 D = 347 H = 347-480* *Not available with Fusing. Must choose a descreet voltage with F Option 30 = 3000K‹› 40 = 4000K 50 = 5000K ‹›Select 3000K CCT for IDA Approved units SM = Symmetric Medium SW = Symmetric Wide SH = Symmetric High Angle AF = Asymmetric Forward AH = Asymmetric High Angle AW = Asymmetric Wide AN = Asymmetric Narrow/Auto N = Dimming thru PE receptacle D = External Dimming 18/2-3ft cable X = Non-dimmable* All constructions supplied with ANSI C136.41 7-pin Receptacle *Required for Cx Optical Codes. Not available for other optical codes. Note: Standard dimming 0-10V 7 = 70 (min) OPTIONSCOLOR GRAY = Gray BLCK = Black DKBZ = Dark Bronze WHTE = White MOuNTING ARM C1 = Integral Slipfitter for 1.25” - 2” Pipe (1.66in. OD - 2.378in. OD)* D1 = Universal Mounting Arm, fitted for round or square pole mounting** K1 = Knuckle Slipfitter for 1.9 in - 2.3in. OD Tenon*++ S1 = Knuckle Slipfitter for 2.3in. - 3.0in OD Tenon*++ V1 = Knuckle Wall Mount*++ * Supplied with 3FT leads ** Supplied with 3FT #14/3 power cable ++ Restricted Aiming Angle 0° to +45° CONTROLS A = ANSI 7-pin PE receptacle (no control) D = ANSI 7-pin PE receptacle with shorting cap provided Note: See accessories section on page 10 for PE Control ordering CCT DIMMING DISTRIBuTION E = Evolve AL = Area Light S = Standard Ordering Number Logic Evolve™ LED Area Light (EALS-03) GENERATION 03 = 3rd Generation C5 Symmetric Medium (SM) 7300 7500 46 B3-U0-G1 B3-U0-G1 EALS03_C5SM730_.IES EALS03_C5SM740_.IES EALS03_C5SM750_.IES D5 Symmetric Medium (SM) 9800 10000 64 B3-U0-G1 B3-U0-G1 EALS03_D5SM730_.IES EALS03_D5SM740_.IES EALS03_D5SM750_.IES F5 Symmetric Medium (SM) 14700 15000 101 B4-U0-G2 B4-U0-G2 EALS03_F5SM730_.IES EALS03_F5SM740_.IES EALS03_F5SM750_.IES H5 Symmetric Medium (SM) 19600 20000 140 B4-U0-G2 B4-U0-G2 EALS03_H5SM730_.IES EALS03_H5SM740_.IES EALS03_H5SM750_.IES J5 Symmetric Medium (SM) 24500 25000 186 B4-U0-G2 B4-U0-G2 EALS03_J5SM730_.IES EALS03_J5SM740_.IES EALS03_J5SM750_.IES K5 Symmetric Medium (SM) 29400 30000 239 B5-U0-G3 B5-U0-G3 EALS03_K5SM730_.IES EALS03_K5SM740_.IES EALS03_K5SM750_.IES C5 Symmetric Wide (SW) 7300 7500 46 B2-U0-G1 B2-U0-G1 EALS03_C5SW730_.IES EALS03_C5SW740_.IES EALS03_C5SW750_.IES D5 Symmetric Wide (SW) 9800 10100 64 B3-U0-G1 B3-U0-G1 EALS03_D5SW730_.IES EALS03_D5SW740_.IES EALS03_D5SW750_.IES F5 Symmetric Wide (SW) 14700 15100 101 B3-U0-G2 B3-U0-G2 EALS03_F5SW730_.IES EALS03_F5SW740_.IES EALS03_F5SW750_.IES H5 Symmetric Wide (SW) 19700 20200 140 B4-U0-G2 B4-U0-G2 EALS03_H5SW730_.IES EALS03_H5SW740_.IES EALS03_H5SW750_.IES J5 Symmetric Wide (SW) 24600 25200 186 B4-U0-G2 B4-U0-G2 EALS03_J5SW730_.IES EALS03_J5SW740_.IES EALS03_J5SW750_.IES K5 Symmetric Wide (SW) 29600 30300 239 B5-U0-G2 B5-U0-G2 EALS03_K5SW730_.IES EALS03_K5SW740_.IES EALS03_K5SW750_.IES C5 Symmetric High Angle (SH) 7000 7200 46 B3-U0-G1 B3-U0-G1 EALS03_C5SH730_.IES EALS03_C5SH740_.IES EALS03_C5SH750_.IES D5 Symmetric High Angle (SH) 9400 9600 64 B3-U0-G2 B3-U0-G2 EALS03_D5SH730_.IES EALS03_D5SH740_.IES EALS03_D5SH750_.IES F5 Symmetric High Angle (SH) 14200 14500 101 B4-U0-G2 B4-U0-G2 EALS03_F5SH730_.IES EALS03_F5SH740_.IES EALS03_F5SH750_.IES H5 Symmetric High Angle (SH) 18900 19300 140 B4-U0-G2 B4-U0-G2 EALS03_H5SH730_.IES EALS03_H5SH740_.IES EALS03_H5SH750_.IES J5 Symmetric High Angle (SH) 23600 24100 186 B5-U0-G3 B5-U0-G3 EALS03_J5SH730_.IES EALS03_J5SH740_.IES EALS03_J5SH750_.IES K5 Symmetric High Angle (SH) 28400 29000 239 B5-U0-G3 B5-U0-G3 EALS03_K5SH730_.IES EALS03_K5SH740_.IES EALS03_K5SH750_.IES C4 Asymmetric Forward (AF) 7300 7500 50 B1-U0-G2 B1-U0-G2 EALS03_C4AF730_.IES EALS03_C4AF740_.IES EALS03_C4AF750_.IES D4 Asymmetric Forward (AF) 9800 10000 70 B2-U0-G2 B2-U0-G2 EALS03_D4AF730_.IES EALS03_D4AF740_.IES EALS03_D4AF750_.IES F4 Asymmetric Forward (AF) 14700 15000 116 B2-U0-G2 B2-U0-G2 EALS03_F4AF730_.IES EALS03_F4AF740_.IES EALS03_F4AF750_.IES H4 Asymmetric Forward (AF) 19600 20000 140 B3-U0-G3 B3-U0-G3 EALS03_H4AF730_.IES EALS03_H4AF740_.IES EALS03_H4AF750_.IES J4 Asymmetric Forward (AF) 24500 25000 186 B3-U0-G3 B3-U0-G3 EALS03_J4AF730_.IES EALS03_J4AF740_.IES EALS03_J4AF750_.IES K4 Asymmetric Forward (AF) 29400 30000 239 B3-U0-G4 B3-U0-G4 EALS03_K4AF730_.IES EALS03_K4AF740_.IES EALS03_K4AF750_.IES C4 Asymmetric High Angle (AH) 7000 7200 50 B2-U0-G2 B2-U0-G2 EALS03_C4AH730_.IES EALS03_C4AH740_.IES EALS03_C4AH750_.IES D4 Asymmetric High Angle (AH) 9400 9600 70 B2-U0-G2 B2-U0-G2 EALS03_D4AH730_.IES EALS03_D4AH740_.IES EALS03_D4AH750_.IES F4 Asymmetric High Angle (AH) 14200 14500 116 B3-U0-G3 B3-U0-G3 EALS03_F4AH730_.IES EALS03_F4AH740_.IES EALS03_F4AH750_.IES H4 Asymmetric High Angle (AH) 18900 19300 140 B3-U0-G3 B3-U0-G4 EALS03_H4AH730_.IES EALS03_H4AH740_.IES EALS03_H4AH750_.IES J4 Asymmetric High Angle (AH) 23600 24100 186 B3-U0-G4 B3-U0-G4 EALS03_J4AH730_.IES EALS03_J4AH740_.IES EALS03_J4AH750_.IES K4 Asymmetric High Angle (AH) 28400 29000 239 B3-U0-G4 B3-U0-G4 EALS03_K4AH730_.IES EALS03_K4AH740_.IES EALS03_K4AH750_.IES C3 Asymmetric Wide (AW) 7300 7500 50 B2-U0-G1 B2-U0-G1 EALS03_C3AW730_.IES EALS03_C3AW740_.IES EALS03_C3AW750_.IES D3 Asymmetric Wide (AW) 9800 10100 70 B2-U0-G2 B2-U0-G2 EALS03_D3AW730_.IES EALS03_D3AW740_.IES EALS03_D3AW750_.IES F3 Asymmetric Wide (AW) 14700 15100 116 B2-U0-G2 B2-U0-G2 EALS03_F3AW730_.IES EALS03_F3AW740_.IES EALS03_F3AW750_.IES H3 Asymmetric Wide (AW) 19700 20200 140 B3-U0-G2 B3-U0-G3 EALS03_H3AW730_.IES EALS03_H3AW740_.IES EALS03_H3AW750_.IES J3 Asymmetric Wide (AW) 24600 25200 186 B3-U0-G3 B3-U0-G3 EALS03_J3AW730_.IES EALS03_J3AW740_.IES EALS03_J3AW750_.IES K3 Asymmetric Wide (AW) 29600 30300 239 B3-U0-G3 B3-U0-G3 EALS03_K3AW730_.IES EALS03_K3AW740_.IES EALS03_K3AW750_.IES C2 Asymmetric Narrow/Auto (AN) 7300 7500 50 B2-U0-G2 B2-U0-G2 EALS03_C2AN730_.IES EALS03_C2AN740_.IES EALS03_C2AN750_.IES D2 Asymmetric Narrow/Auto (AN) 9800 10100 70 B2-U0-G2 B2-U0-G2 EALS03_D2AN730_.IES EALS03_D2AN740_.IES EALS03_D2AN750_.IES F2 Asymmetric Narrow/Auto (AN) 14700 15100 116 B3-U0-G3 B3-U0-G3 EALS03_F2AN730_.IES EALS03_F2AN740_.IES EALS03_F2AN750_.IES H2 Asymmetric Narrow/Auto (AN) 19700 20200 140 B3-U0-G3 B3-U0-G3 EALS03_H2AN730_.IES EALS03_H2AN740_.IES EALS03_H2AN750_.IES J2 Asymmetric Narrow/Auto (AN) 24600 25200 186 B3-U0-G3 B3-U0-G3 EALS03_J2AN730_.IES EALS03_J2AN740_.IES EALS03_J2AN750_.IES K2 Asymmetric Narrow/Auto (AN) 29600 30300 239 B3-U0-G3 B3-U0-G3 EALS03_K2AN730_.IES EALS03_K2AN740_.IES EALS03_K2AN750_.IES OPTICAL CODE TYPE DISTRIBuTION 4000K & 5000K3000K 120-277V & 347-480V TYPICAL INITIAL LuMENS TYPICAL SYSTEM WATTAGE 3000K B-u-G 4000 & 5000K B-u-G 3000K IES FILE NuMBER 4000K IES FILE NuMBER 5000K IES FILE NuMBER BuG RATING Type V Type IV Type III Type II Pole Right (S2) Pole Left (S1) F = Fusing H = Motion Sensor (Sensor Switch) H2 = Motion Sensor (Daintree) J = cUL/Canada L = Tool-Less Entry R = Enhanced Surge Protection (10kV/5kA) S1 = Rotated Left † S2 = Rotated Right † T = Elevated Surge Protection (20kV/10kA) u = DALI dimming ^+ V = 3-Position Terminal Block Y = Coastal Finish XXX = Special Options * Contact Manufacturer for availability + Compatible with LightGrid 2.0 nodes^Notcompatibleat347-480V or with motion sensor control †Foraimedleftorrightlightdistribution orientation, as assembled in manufacturing. NotapplicableforSymmetricDistributions. Note: H2optionnotavailableat370V-480V Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCK (TYPE IV HSS) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS PLEASE SPECIFY VOLTAGE PLEASE SPECIFY FINISH 11/12/19 Photometrics Evolve™ LED Area Light (EALS-03) EALS Type II - Asymmetric Narrow/Auto 30,300 Lumens, 5000K (EALS03_K2AN750___.IES) EALS Type VS - Symmetric High Angle 29,000 Lumens, 5000K (EALS03_K5SH750___.IES) EALS Type III - Asymmetric Wide 30,300 Lumens, 5000K (EALS03_K3AW750___.IES) EALS Type VS - Symmetric Medium 30,000 Lumens, 5000K (EALS03_K5SM750___.IES) EALS Type IV - Asymmetric Forward 30,000 Lumens, 5000K (EALS03_K4AF750___.IES) EALS Type VS - Symmetric Wide 30,300 Lumens, 5000K (EALS03_K5SW750___.IES) EALS Type IV - Asymmetric High Angle 29,000 Lumens, 5000K (EALS03_K4AH750___.IES) Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 55° Vertical plane through horizontal angle of 34° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 58° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 20° Vertical plane through horizontal angle of 58° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 70° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 50° Vertical plane through horizontal angle of 69° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 65° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 50° Vertical plane through horizontal angle of 55° .1 .2 .5 3642 7284 10926 14569 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4014 8028 12043 16057 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4580 9161 13741 18321 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4483 8966 13449 17931 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2.5 2544 5089 7633 10178 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 2619 5239 7858 10478 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 2561 5121 7682 10243 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCK (TYPE IV HSS) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 Shielding for EAL Area Light Fixtures Evolve ™ LED Area Light The next evolution of the GE Evolve™ LED Area Light delivers even better trespass control. GE’s exclusive reflective optical ring design produces superior vertical illuminace and efficiently directs the light without wasteful and unwelcomed light spill into neighboring properties. Due to the extensive variation of parking lot configurations coupled with tightening ordinances, GE now offers a full array of shielding to accommodate challenging sites. The shielding options available for the GE Evolve Area Light focus on the following applications: • Left and Right cutoff • Front cutoff • Backlight control and B-U-G improvement Within each of the shielding families, there are multiple shielding cutoff levels that are categorized in mounting height (MH) increments. GE accommodates cutoff distance from the pole from 1MH to 2.5 MH in 0.5 MH increments. The shields that are listed are for the most common applications. Please contact the manufacturer if your need is not listed. All shields can be installed easily in the field. The next evolution of the GE Evolve LED Area Light and shielding options will help you meet any parking lot challenge. 1 MH MH 2.5 MH Description : ELS-EAL-RBL-BLCK Project Name:CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 Single Module Left/Right Shield Double Module Left/Right Shield Single Module Front Shield Double Module Front Shield Single Module Back Shield Double Module Back Shield EAL Shielded Fixture Examples 2 Module Optical Codes 2 Module Optical Codes H4, H3, H2 J4, J3, J2 K4, J3, J2 L4, J3, J2 C5, D5, F5, H5, J5, K5, L5 M5, N5, Q5, S5, T5, U5, V5 KA, LA H4, H3, H2 J4, J3, J2 K4, J3, J2 D5, F5, H5, J5, K5 N5, Q5, S5, T5, U5 KA EALP01 EALS01 1 Module Optical Codes C4, C3, C2 D4, D3, D2 F4, F3, F2 EALP01 1 Module Optical Codes D4, D3, D2 F4, F3, F2 EALS01 Description : ELS-EAL-RBL-BLCK Project Name:CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 Type V Shielding Type IV Shielding Cutoff Distance Shield Orientation Fixture Type Shield Order Logic 1 ELS-EAL-FF2-BLCK 1.5 ELS-EAL-FF3-BLCKFront2 2 Module ELS-EAL-FF4-BLCK 2.5 ELS-EAL-FF5-BLCK 1 ELS-EAL-RF2-BLCK 1.5 ELS-EAL-RF3-BLCK Front 2 1 Module ELS-EAL-RF4-BLCK 2.5 ELS-EAL-RF5-BLCK 0.5 ELS-EAL-FS1-BLCK 1 ELS-EAL-FS2-BLCK Side 1.5 2 Module ELS-EAL-FS3-BLCK 2 ELS-EAL-FS4-BLCK 2.5 ELS-EAL-FS5-BLCK 0.5 ELS-EAL-RS1-BLCK 1 ELS-EAL-RS2-BLCK Side 1.5 1 Module ELS-EAL-RS3-BLCK 2 ELS-EAL-RS4-BLCK 2.5 ELS-EAL-RS5-BLCK Back Short 2 Module ELS-EAL-FBN-BLCK Long ELS-EAL-FBL-BLCK Back Long 1 Module ELS-EAL-RBL-BLCK Cutoff Distance Shield Orientation Fixture Type Shield Order Logic 0.5 ELS-EAL-MS1-BLCK 1 ELS-EAL-MS2-BLCK Any Side 1.5 2 Module ELS-EAL-MS3-BLCK 2 (Symmetric Medium) ELS-EAL-MS4-BLCK 2.5 ELS-EAL-MS5-BLCK 0.5 ELS-EAL-SS1-BLCK 1 ELS-EAL-SS2-BLCK Any Side 1.5 2 Module ELS-EAL-SS3-BLCK 2 (Symmetric Wide) ELS-EAL-SS4-BLCK 2.5 ELS-EAL-SS5-BLCK Description : ELS-EAL-RBL-BLCK Project Name:CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 Pole Cap - Plastic Poles - Steel SSS / DS330 Fatigue ResistantSPECIFICATIONS Pole Shaft - The pole shaft is fabricated from hot rolled welded steel tubing of one-piece construction with a minimum yield strength of 55 KSI. Pole Top – A removable pole cap is provided for poles receiving drilling patterns for side-mount luminaire arm assemblies. For top mount luminaire and/or bracket consult the factory. Consult the luminaire manufacturer for correct tenon size or drill pattern. Other pole top options include pole cap only (PC) or plain top (PL) which is typical when the pole top diameter matches the necessary slip fit dimensions. Handhole – A reinforced handhole with grounding provision is provided at 1’-6” from the base end of the pole assembly. Each handhole includes a cover and the cover attachment hardware. All pole assemblies are provided with a 2.5” x 5” rectangular handhole. Handhole dimensions are nominal. Base Cover – A two-piece full base cover fabricated from ABS plastic is provided with each pole assembly. Additional base cover options, including the dart square (2T) cast aluminum cover, are available upon request. Anchor Bolts - Anchor bolts conform to ASTM F1554 Grade 55 and are provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and are galvanized a minimum of 12” on the threaded end. Hardware - All structural fasteners are galvanized high strength carbon steel. All non-structural fasteners are galvanized or zinc-plated carbon steel or stainless steel. Finish - Standard finishes are either Galvanized (GV) or Finish Painted (FP). Additional finish options including Finish Paint over Galvanizing (FPGV) or any of the V-PROTM Finish Coating Systems are available upon request. See the product ordering code for color options. Design Criteria - Please reference Design Criteria Specification for appropriate design conditions. VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM SOFT SQUARE STEEL DS330 Fatigue Resistant Job Name: Job Location - City: State: Product: Quote: Client Name: Created By: Date: Customer Approval: Date: Cross Section Handhole Full Base Cover (Standard) Handhole 1’-6” Nominal Mounting HeightTenon Top* * Consult factory on loading criteria for pole top mounted luminaires and/or brackets. Dart Square - 2T (Optional) Soft Square Description : DS330-400Q200-D1-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 DESIGNATION, LOAD AND DIMENSIONAL DATA VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM SOFT SQUARE STEEL DS330 Fatigue Resistant 1. Maximum EPA (Effective Projected Area) and weight values are based on side mounted fixtures only. Consult factory on loading criteria for pole top mounted luminaires and/or brackets. Variations from sizes above are available upon inquiry at the factory. Satisfactory performance of poles is dependent upon the pole being properly attached to a supporting foundation of adequate design. 2. Structure weight is a nominal value which includes the pole shaft and base plate only. 3. Belled-bottom will have reduced thickness due to the cold-working process. However, the belled-bottom meets or exceeds the structural capacity of the original square section. In addition, the rounded section provides better fatigue resistance. Job Name: Job Location - City: State: Product: Quote: Client Name: Created By: Date: Customer Approval: Date:Poles - Steel SSS / DS330 Fatigue ResistantSTANDARD ORDERING CODE STRUCTURE ANCHORAGE DATA POLE BASE PLATE ANCHOR BOLTS POLE BASE SQUARE (IN) WALL THK (GA) BOLT CIRCLE SQUARE (IN) THK (IN) DIA x LENGTH x HOOK (IN) PROJECTION (IN) + (IN) DIA (IN) + (IN) 4.00 11 8.50 0.50 8.25 0.750 0.75 x 17.00 x 3.00 3.50 0.25 4.00 7 8.50 0.50 8.25 0.875 0.75 x 17.00 x 3.00 3.63 0.25 5.00 11 11.00 1.00 11.00 1.000 0.75 x 17.00 x 3.00 3.75 0.25 5.00 7 11.00 1.00 11.00 1.000 0.75 x 17.00 x 3.00 3.75 0.25 6.00 7 12.00 1.00 12.50 1.000 1.00 x 36.00 x 4.00 4.25 0.25 Anchor Base Detail Bolt Circle Bolt Slots/Holes 0° - Handhole 270°90° 180° As viewed from top of pole. DESIGNATION FIXTURE MOUNTING FINISH SYSTEM ANCHOR BOLTS BASE COVER MODEL DS330 Drill Mounting (See Orientation) D1 = (1) Drilling @ 270° D2 = (2) Drillings @ 90° & 270° D4 = (4) Drillings @ 0°, 90°, 180°, & 270° D5 = (2) Drillings @ 90° & 180° D6 = (3) Drillings @ 90°, 180°, & 270° Tenon Mounting P2 = 2.38” OD x 4” tenon P4 = 4.00” OD x 6” tenon P5 = 2.88” OD x 4” tenon P6 = 2.88” OD x 5” tenon P7 = 2.38” OD x 5” tenon P9 = Special Size (Specify) Other Options PC = Pole Cap PL = Plain Top (No Cap) GV = Galvanized FP = Finish Painted -----OPTIONAL----- FPGV = Finish Paint over Galvanizing VP30 = V-PRO™ 30 System VP32 = V-PRO™ 32 System VP53 = V-PRO™ 53 System VP54 = V-PRO™ 54 System VP57 = V-PRO™ 57 System VP100 = V-PRO™ 100 System VP105 = V-PRO™ 105 System GV = Galvanized BK = Black DB = Dark Bronze MB = Medium Bronze WH =White LG =Light Gray CB = Bronze DG = Dark Green ST = Sandstone HG = Hunter Green SG = Slate Gray SL = Silver SC = Special Color (Specify) FBC = Full Base Cover -----OPTIONAL----- 2T = Square Dart Cover AB = With Anchor Bolts LAB = Without Anchor Bolts SUPPLEMENTAL INFO Select Correct Designation from the Load and Dimensional Data Chart. STANDARD COLOR OPTIONS 90° DESIGN INFORMATION POLE DIMENSIONS3 NOMINAL MOUNTING HEIGHT 80 MPH w/1.3 GUST 90 MPH w/1.3 GUST 100 MPH w/1.3 GUST SHAFT BASE SQUARE3 (IN) SHAFT TOP SQUARE (IN) WALL THK (GA) STRUCTURE WEIGHT 2 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) 10'-0" 30.6 765 23.8 595 18.9 473 4.00 4.00 11 75 400Q100 12'-0" 24.4 610 18.8 470 14.8 370 4.00 4.00 11 90 400Q120 14'-0" 19.9 498 15.1 378 11.7 293 4.00 4.00 11 100 400Q140 16'-0" 15.9 398 11.8 295 8.9 223 4.00 4.00 11 115 400Q160 18'-0" 12.6 315 9.2 230 6.7 168 4.00 4.00 11 125 400Q180 20'-0" 9.6 240 6.7 167 4.5 150 4.00 4.00 11 140 400Q200 17.7 443 12.7 343 9.4 235 5.00 5.00 11 185 500Q200 28.1 703 21.4 535 16.2 405 5.00 5.00 7 265 500W200 25'-0" 4.8 150 2.6 100 1.0 50 4.00 4.00 11 170 400Q250 10.8 270 7.7 188 5.4 135 4.00 4.00 7 245 400W250 9.8 245 6.3 157 3.7 150 5.00 5.00 11 225 500Q250 18.5 463 13.3 333 9.5 238 5.00 5.00 7 360 500W250 30'-0" 6.7 168 4.4 110 2.6 65 4.00 4.00 7 291 400W300 4.7 150 2.0 50 N/A N/A 5.00 5.00 11 265 500Q300 10.7 267 6.7 167 3.9 100 5.00 5.00 7 380 500W300 19.0 475 13.2 330 9.0 225 6.00 6.00 7 520 600W300 35'-0"5.9 150 2.5 100 N/A N/A 5.00 5.00 7 440 500W350 12.4 310 7.6 190 4.2 105 6.00 6.00 7 540 600W350 40'-0" 7.2 180 3.0 75 N/A N/A 6.00 6.00 7 605 600W400 DESIGNATION Description : DS330-400Q200-D1-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 400Q200 D1 FP -- FBC AB PLEASE SPECIFY FINISH 11/12/19 38 DS330 Fatigue Resistant Square Non-Tapered VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM SPC7207 03/16 valmontstructures.com carries the most current spec information and supersedes these guidelines.Description : DS330-400Q200-D1-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SAHS 11/12/19 GE Evolve ™ LED Area Lighting EALS-03 & EALP-03 EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCKEALS-03-XX-F4-AH-7-40-N-D-D1-XX F4AHSSB2 Description : EALS-03-VOLT-D5-SH-7-40-N-D-D1-XX (TYPE V) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: 11/12/19 Applications • Site and area light applications such as parking lots, retail exteriors, commercial exteriors, roadways and other general lighting applications Housing • Slim architectural design incorporates an integral heat sink and light engine, ensuring maximum heat transfer, and long LED life. • Die cast aluminum housing • 3G vibration per ANSI C136.31-2010 LED & Optical Assembly • LM-79 tests and reports in accordance with IESNA standards • Upward Light Output Ratio (ULOR) = 0 (horizontal orientation) • 70CRI at 3000K, 4000K and 5000K • Distributions: II, III, IV, V Lumen Maintenance • Projected Lxx per IES TM-21 at 25 °C for reference: Ratings • cUL Listed • UL 1598 Listed Suitable for Wet Locations • IP65 optical enclosure per ANSI C136.25-2013 • Operating Temperature –40°C to +40°C (maximum of +35°C for 570W) • California Title 24 compliant (w/ “H” motion sensor option) Mounting Option C1: Integral Slipfitter for 1.25”-2” Pipe (1.66 in. OD-2.378 in. OD) supplied with leads. +/- 5 deg adjustment for leveling. Option D1: Universal Mounting Arm, fitted for round or square pole mounting supplied with 16/3 3ft cable. Option K1: Knuckle Slipfitter for 1.9 in.-2.3 in. OD Tenon with leads. Restricted aiming angle 0° to +45°. Option S1: Knuckle Slipfitter for 2.3 in.- 3.0 in OD Tenon with leads. Restricted aiming angle 0° to +45°. Option V1: Knuckle Wall Mount with leads. Restricted aiming angle 0° to +45°. Finish • Corrosion resistant polyester powder paint, minimum thickness 2.0 mil. • Standard colors: Black, Dark Bronze, Aluminum, Gray & White. • RAL & custom colors available. • Optional coastal finish available. Electrical • 120-277 VAC and 347-480 VAC available. • System power factor is >90% and THD <20%. • ANSI C136.41 7-pin dimming receptacle, standard. • ANSI photo electric sensors (PE) available for all voltages. • LightGrid™ compatible. • Dimming/Occupancy: – Standard: 0-10V; Optional: DALI (120-277V, excluding 400 watts and above) –Externally wired 0-10V dimming (optional) – DALI digital dimming. Contact manufacturer for availability. –Standalone dimming occupancy sensor with ambient light sensor, option code “H”. –Daintree occupancy sensor available. • Surge Protection tested per ANSI C136.2-2015. –6kV/3kA “Basic” surge protection, standard. –10kV/5kA “Enhanced” surge protection optional. Warranty • 5 Year Standard Accessories • Photoelectric Controls (see page 10) • Light Shields (see Data Sheet OLP 3120 Shielding for EAL Area Light Fixtures) The EAL Area Light luminaires offer a wide range of optical patterns, color temperatures, lumen packages, and mounting configurations to optimize area light applications, as well as provide versatility in lighting design within the same form-factor. They are ideal for commercial property site-lighting applications such as retail and commercial exteriors. The EALS (standard) area light has a lumen range from 7,500-30,000 lumens. The EALP (premium) offers a similar lumen range of 25,000 to 70,000 lumens but with higher LPW and better lumen maintenance. Both the EALS-03 and EALP-03 feature our innovative, highly flexible Universal Mounting Arm option, which provides installers the ability to mount the EAL fixtures on both round and square poles of multiple sizes. In addition, it features both in-line and offset bolt patterns which enable it to easily be affixed to the majority of the bolt patterns one would encounter in the field. Product Features Note: 1) Projected Lxx based on LM80 (10,000 hour testing). 2) DOE Lighting Facts Verification Testing Tolerances apply to initial luminous flux and lumen maintenance measurements J5, K2, K3, K4, K5 L97 L96 L94 L2, L3, L4, L5, M2, M3, M4, M5 L97 L96 L94 J2, J3, J4, N2, N3, N4, N5 L94 L91 L84 P2, P3, P4, P5, Q2, Q3, Q4, Q5 L94 L91 L84 EALP03 Optical code 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours C2, C3, C4, C5, D2, D3, D4, D5 L95 L92 L86 F5, H2, H3, H4, H5 L95 L92 L86 F2, F3, F4, J2, J3, J4, J5 L94 L89 L81 K2, K3, K4, K5 L94 L89 L81 EALS03 Optical code 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours 10 1.02 20 1.01 25 1.00 30 0.99 40 0.98 Ambient Temp (°C ) Initial Flux Factor Lumen Ambient Temperature Factors: DLC Standard qualified models available. Please refer to http://www.designlights.org/QPL for complete information. DLC Premium qualified models available. Please refer to http://www.designlights.org/QPL for complete information. EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCK F4AH EALS-03-XX-F4-AH-7-40-N-D-D1-XXDescription : EALS-03-VOLT-D5-SH-7-40-N-D-D1-XX (TYPE V) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SB2 11/12/19 E A L S 0 3 7 ______ __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ PROD. ID VOLTAGE OPTICAL CODE CRI 0 = 120-277* 1 = 120 2 = 208 3 = 240 4 = 277 5 = 480 D = 347 H = 347-480* *Not available with Fusing. Must choose a descreet voltage with F Option 30 = 3000K‹› 40 = 4000K 50 = 5000K ‹›Select 3000K CCT for IDA Approved units SM = Symmetric Medium SW = Symmetric Wide SH = Symmetric High Angle AF = Asymmetric Forward AH = Asymmetric High Angle AW = Asymmetric Wide AN = Asymmetric Narrow/Auto N = Dimming thru PE receptacle D = External Dimming 18/2-3ft cable X = Non-dimmable* All constructions supplied with ANSI C136.41 7-pin Receptacle *Required for Cx Optical Codes. Not available for other optical codes. Note: Standard dimming 0-10V 7 = 70 (min) OPTIONSCOLOR GRAY = Gray BLCK = Black DKBZ = Dark Bronze WHTE = White MOuNTING ARM C1 = Integral Slipfitter for 1.25” - 2” Pipe (1.66in. OD - 2.378in. OD)* D1 = Universal Mounting Arm, fitted for round or square pole mounting** K1 = Knuckle Slipfitter for 1.9 in - 2.3in. OD Tenon*++ S1 = Knuckle Slipfitter for 2.3in. - 3.0in OD Tenon*++ V1 = Knuckle Wall Mount*++ * Supplied with 3FT leads ** Supplied with 3FT #14/3 power cable ++ Restricted Aiming Angle 0° to +45° CONTROLS A = ANSI 7-pin PE receptacle (no control) D = ANSI 7-pin PE receptacle with shorting cap provided Note: See accessories section on page 10 for PE Control ordering CCT DIMMING DISTRIBuTION E = Evolve AL = Area Light S = Standard Ordering Number Logic Evolve™ LED Area Light (EALS-03) GENERATION 03 = 3rd Generation C5 Symmetric Medium (SM) 7300 7500 46 B3-U0-G1 B3-U0-G1 EALS03_C5SM730_.IES EALS03_C5SM740_.IES EALS03_C5SM750_.IES D5 Symmetric Medium (SM) 9800 10000 64 B3-U0-G1 B3-U0-G1 EALS03_D5SM730_.IES EALS03_D5SM740_.IES EALS03_D5SM750_.IES F5 Symmetric Medium (SM) 14700 15000 101 B4-U0-G2 B4-U0-G2 EALS03_F5SM730_.IES EALS03_F5SM740_.IES EALS03_F5SM750_.IES H5 Symmetric Medium (SM) 19600 20000 140 B4-U0-G2 B4-U0-G2 EALS03_H5SM730_.IES EALS03_H5SM740_.IES EALS03_H5SM750_.IES J5 Symmetric Medium (SM) 24500 25000 186 B4-U0-G2 B4-U0-G2 EALS03_J5SM730_.IES EALS03_J5SM740_.IES EALS03_J5SM750_.IES K5 Symmetric Medium (SM) 29400 30000 239 B5-U0-G3 B5-U0-G3 EALS03_K5SM730_.IES EALS03_K5SM740_.IES EALS03_K5SM750_.IES C5 Symmetric Wide (SW) 7300 7500 46 B2-U0-G1 B2-U0-G1 EALS03_C5SW730_.IES EALS03_C5SW740_.IES EALS03_C5SW750_.IES D5 Symmetric Wide (SW) 9800 10100 64 B3-U0-G1 B3-U0-G1 EALS03_D5SW730_.IES EALS03_D5SW740_.IES EALS03_D5SW750_.IES F5 Symmetric Wide (SW) 14700 15100 101 B3-U0-G2 B3-U0-G2 EALS03_F5SW730_.IES EALS03_F5SW740_.IES EALS03_F5SW750_.IES H5 Symmetric Wide (SW) 19700 20200 140 B4-U0-G2 B4-U0-G2 EALS03_H5SW730_.IES EALS03_H5SW740_.IES EALS03_H5SW750_.IES J5 Symmetric Wide (SW) 24600 25200 186 B4-U0-G2 B4-U0-G2 EALS03_J5SW730_.IES EALS03_J5SW740_.IES EALS03_J5SW750_.IES K5 Symmetric Wide (SW) 29600 30300 239 B5-U0-G2 B5-U0-G2 EALS03_K5SW730_.IES EALS03_K5SW740_.IES EALS03_K5SW750_.IES C5 Symmetric High Angle (SH) 7000 7200 46 B3-U0-G1 B3-U0-G1 EALS03_C5SH730_.IES EALS03_C5SH740_.IES EALS03_C5SH750_.IES D5 Symmetric High Angle (SH) 9400 9600 64 B3-U0-G2 B3-U0-G2 EALS03_D5SH730_.IES EALS03_D5SH740_.IES EALS03_D5SH750_.IES F5 Symmetric High Angle (SH) 14200 14500 101 B4-U0-G2 B4-U0-G2 EALS03_F5SH730_.IES EALS03_F5SH740_.IES EALS03_F5SH750_.IES H5 Symmetric High Angle (SH) 18900 19300 140 B4-U0-G2 B4-U0-G2 EALS03_H5SH730_.IES EALS03_H5SH740_.IES EALS03_H5SH750_.IES J5 Symmetric High Angle (SH) 23600 24100 186 B5-U0-G3 B5-U0-G3 EALS03_J5SH730_.IES EALS03_J5SH740_.IES EALS03_J5SH750_.IES K5 Symmetric High Angle (SH) 28400 29000 239 B5-U0-G3 B5-U0-G3 EALS03_K5SH730_.IES EALS03_K5SH740_.IES EALS03_K5SH750_.IES C4 Asymmetric Forward (AF) 7300 7500 50 B1-U0-G2 B1-U0-G2 EALS03_C4AF730_.IES EALS03_C4AF740_.IES EALS03_C4AF750_.IES D4 Asymmetric Forward (AF) 9800 10000 70 B2-U0-G2 B2-U0-G2 EALS03_D4AF730_.IES EALS03_D4AF740_.IES EALS03_D4AF750_.IES F4 Asymmetric Forward (AF) 14700 15000 116 B2-U0-G2 B2-U0-G2 EALS03_F4AF730_.IES EALS03_F4AF740_.IES EALS03_F4AF750_.IES H4 Asymmetric Forward (AF) 19600 20000 140 B3-U0-G3 B3-U0-G3 EALS03_H4AF730_.IES EALS03_H4AF740_.IES EALS03_H4AF750_.IES J4 Asymmetric Forward (AF) 24500 25000 186 B3-U0-G3 B3-U0-G3 EALS03_J4AF730_.IES EALS03_J4AF740_.IES EALS03_J4AF750_.IES K4 Asymmetric Forward (AF) 29400 30000 239 B3-U0-G4 B3-U0-G4 EALS03_K4AF730_.IES EALS03_K4AF740_.IES EALS03_K4AF750_.IES C4 Asymmetric High Angle (AH) 7000 7200 50 B2-U0-G2 B2-U0-G2 EALS03_C4AH730_.IES EALS03_C4AH740_.IES EALS03_C4AH750_.IES D4 Asymmetric High Angle (AH) 9400 9600 70 B2-U0-G2 B2-U0-G2 EALS03_D4AH730_.IES EALS03_D4AH740_.IES EALS03_D4AH750_.IES F4 Asymmetric High Angle (AH) 14200 14500 116 B3-U0-G3 B3-U0-G3 EALS03_F4AH730_.IES EALS03_F4AH740_.IES EALS03_F4AH750_.IES H4 Asymmetric High Angle (AH) 18900 19300 140 B3-U0-G3 B3-U0-G4 EALS03_H4AH730_.IES EALS03_H4AH740_.IES EALS03_H4AH750_.IES J4 Asymmetric High Angle (AH) 23600 24100 186 B3-U0-G4 B3-U0-G4 EALS03_J4AH730_.IES EALS03_J4AH740_.IES EALS03_J4AH750_.IES K4 Asymmetric High Angle (AH) 28400 29000 239 B3-U0-G4 B3-U0-G4 EALS03_K4AH730_.IES EALS03_K4AH740_.IES EALS03_K4AH750_.IES C3 Asymmetric Wide (AW) 7300 7500 50 B2-U0-G1 B2-U0-G1 EALS03_C3AW730_.IES EALS03_C3AW740_.IES EALS03_C3AW750_.IES D3 Asymmetric Wide (AW) 9800 10100 70 B2-U0-G2 B2-U0-G2 EALS03_D3AW730_.IES EALS03_D3AW740_.IES EALS03_D3AW750_.IES F3 Asymmetric Wide (AW) 14700 15100 116 B2-U0-G2 B2-U0-G2 EALS03_F3AW730_.IES EALS03_F3AW740_.IES EALS03_F3AW750_.IES H3 Asymmetric Wide (AW) 19700 20200 140 B3-U0-G2 B3-U0-G3 EALS03_H3AW730_.IES EALS03_H3AW740_.IES EALS03_H3AW750_.IES J3 Asymmetric Wide (AW) 24600 25200 186 B3-U0-G3 B3-U0-G3 EALS03_J3AW730_.IES EALS03_J3AW740_.IES EALS03_J3AW750_.IES K3 Asymmetric Wide (AW) 29600 30300 239 B3-U0-G3 B3-U0-G3 EALS03_K3AW730_.IES EALS03_K3AW740_.IES EALS03_K3AW750_.IES C2 Asymmetric Narrow/Auto (AN) 7300 7500 50 B2-U0-G2 B2-U0-G2 EALS03_C2AN730_.IES EALS03_C2AN740_.IES EALS03_C2AN750_.IES D2 Asymmetric Narrow/Auto (AN) 9800 10100 70 B2-U0-G2 B2-U0-G2 EALS03_D2AN730_.IES EALS03_D2AN740_.IES EALS03_D2AN750_.IES F2 Asymmetric Narrow/Auto (AN) 14700 15100 116 B3-U0-G3 B3-U0-G3 EALS03_F2AN730_.IES EALS03_F2AN740_.IES EALS03_F2AN750_.IES H2 Asymmetric Narrow/Auto (AN) 19700 20200 140 B3-U0-G3 B3-U0-G3 EALS03_H2AN730_.IES EALS03_H2AN740_.IES EALS03_H2AN750_.IES J2 Asymmetric Narrow/Auto (AN) 24600 25200 186 B3-U0-G3 B3-U0-G3 EALS03_J2AN730_.IES EALS03_J2AN740_.IES EALS03_J2AN750_.IES K2 Asymmetric Narrow/Auto (AN) 29600 30300 239 B3-U0-G3 B3-U0-G3 EALS03_K2AN730_.IES EALS03_K2AN740_.IES EALS03_K2AN750_.IES OPTICAL CODE TYPE DISTRIBuTION 4000K & 5000K3000K 120-277V & 347-480V TYPICAL INITIAL LuMENS TYPICAL SYSTEM WATTAGE 3000K B-u-G 4000 & 5000K B-u-G 3000K IES FILE NuMBER 4000K IES FILE NuMBER 5000K IES FILE NuMBER BuG RATING Type V Type IV Type III Type II Pole Right (S2) Pole Left (S1) F = Fusing H = Motion Sensor (Sensor Switch) H2 = Motion Sensor (Daintree) J = cUL/Canada L = Tool-Less Entry R = Enhanced Surge Protection (10kV/5kA) S1 = Rotated Left † S2 = Rotated Right † T = Elevated Surge Protection (20kV/10kA) u= DALI dimming ^+ V = 3-Position Terminal Block Y = Coastal Finish XXX = Special Options * Contact Manufacturer for availability + Compatible with LightGrid 2.0 nodes^Notcompatibleat347-480V or with motion sensor control †Foraimedleftorrightlightdistribution orientation, as assembled in manufacturing. NotapplicableforSymmetricDistributions. Note: H2optionnotavailableat370V-480V EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCK F4AHS EALS-03-XX-F4-AH-7-40-N-D-D1-XXDescription : EALS-03-VOLT-D5-SH-7-40-N-D-D1-XX (TYPE V) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SB2 PLEASE SPECIFY VOLTAGE PLEASE SPECIFY COLOR 11/12/19 Photometrics Evolve™ LED Area Light (EALS-03) EALS Type II - Asymmetric Narrow/Auto 30,300 Lumens, 5000K (EALS03_K2AN750___.IES) EALS Type VS - Symmetric High Angle 29,000 Lumens, 5000K (EALS03_K5SH750___.IES) EALS Type III - Asymmetric Wide 30,300 Lumens, 5000K (EALS03_K3AW750___.IES) EALS Type VS - Symmetric Medium 30,000 Lumens, 5000K (EALS03_K5SM750___.IES) EALS Type IV - Asymmetric Forward 30,000 Lumens, 5000K (EALS03_K4AF750___.IES) EALS Type VS - Symmetric Wide 30,300 Lumens, 5000K (EALS03_K5SW750___.IES) EALS Type IV - Asymmetric High Angle 29,000 Lumens, 5000K (EALS03_K4AH750___.IES) Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 55° Vertical plane through horizontal angle of 34° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 58° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 20° Vertical plane through horizontal angle of 58° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 70° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 50° Vertical plane through horizontal angle of 69° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 65° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 50° Vertical plane through horizontal angle of 55° .1 .2 .5 3642 7284 10926 14569 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4014 8028 12043 16057 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4580 9161 13741 18321 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4483 8966 13449 17931 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2.5 2544 5089 7633 10178 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 2619 5239 7858 10478 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 2561 5121 7682 10243 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS EALS-03-XX-F4-AH-7-40-N-D-D1-XX-ELS-EAL-RBL-BLCKEALS-03-XX-F4-AH-7-40-N-D-D1-XX F4AHSSB2 Description : EALS-03-VOLT-D5-SH-7-40-N-D-D1-XX (TYPE V) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: 11/12/19 SPECIFICATIONS DS330 Fatigue Resistant Soft Square Steel Post Job Name: Job Location - City: State: Product: Quote: Client Name: Created By: Date: Customer Approval: Date: VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM Pole Shaft - The pole shaft is fabricated from hot rolled welded steel tubing of one-piece construction with a minimum yield strength of 55 KSI. Pole Top – A removable pole cap is provided for poles receiving drilling patterns for side-mount luminaire arm assemblies. For top mount luminaire and/or bracket consult the factory. Consult the luminaire manufacturer for correct tenon size or drill pattern. Other pole top options include pole cap only (PC) or plain top (PL) which is typical when the pole top diameter matches the necessary slip fit dimensions. Handhole – A reinforced handhole with grounding provision is provided at 1'-6" from the base end of the pole assembly. Each handhole includes an easy to install, self-contained Swing Latch handhole cover assembly. U.S. Patent Swing Latch cover is fabricated from durable polycarbonate/ABS blend plastic. All pole assemblies are provided with a 2.50" x 5.00" rectangular handhole. Handhole dimensions are nominal. Base Cover – A two-piece full base cover fabricated from ABS plastic is provided with each pole assembly. Additional base cover options, including the dart square (2T) cast aluminum cover, are available upon request. Anchor Bolts - Anchor bolts conform to ASTM F1554 Grade 55 and are provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and are galvanized a minimum of 12" on the threaded end. Hardware - All structural fasteners are galvanized high strength carbon steel. All non-structural fasteners are galvanized or zinc-plated carbon steel or stainless steel. Finish - Standard finishes are either Galvanized (GV) or Finish Painted (FP). Additional finish options including Finish Paint over Galvanizing (FPGV) or any of the V-PRO TM Finish Coating Systems are available upon request. See the product ordering code for color options. Design Criteria - Please reference Design Criteria Specification for appropriate design conditions. Full Base Cover (Standard) Pole Cap - Plastic Handhole 1'-6" Nominal Mounting HeightTenon Top* Dart Square - 2T (Optional) Cross Section Soft Square Handhole DS330 * Consult factory on loading criteria for pole top mounted luminaires and/or brackets. Description : DS330-400Q200-D2-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SB2 11/12/19 DESIGNATION,LOAD AND DIMENSIONAL DATA ANCHORAGE DATA VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM PRODUCT ORDERING CODES Job Name: Job Location - City: State: Product: Quote: Client Name: Created By: Date: Customer Approval: Date: DS330 Fatigue Resistant Soft Square Steel Post 1. Maximum EPA (Effective Projected Area) and weight values are based on side mounted fixtures only. Consult factory on loading criteria for pole top mounted luminaires and/or brackets. Variations from sizes above are available upon inquiry at the factory. Satisfactory performance of poles is dependent upon the pole being properly attached to a supporting foundation of adequate design. 2. Structure weight is a nominal value which includes the pole shaft and base plate only. 3. Belled-bottom will have reduced thickness due to the cold-working process. However, the belled-bottom meets or exceeds the structural capacity of the original square section. In addition, the rounded section provides better fatigue resistance. 90° DESIGN INFORMATION POLE DIMENSIONS3 NOMINAL MOUNTING HEIGHT 80 MPH w/1.3 GUST 90 MPH w/1.3 GUST 100 MPH w/1.3 GUST SHAFT BASE SQUARE3 (IN) SHAFT TOP SQUARE (IN) WALL THK (GA) STRUCTURE WEIGHT 2 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) 10'-0" 30.6 765 23.8 595 18.9 473 4.00 4.00 11 75 400Q100 12'-0" 24.4 610 18.8 470 14.8 370 4.00 4.00 11 90 400Q120 14'-0" 19.9 498 15.1 378 11.7 293 4.00 4.00 11 100 400Q140 16'-0" 15.9 398 11.8 295 8.9 223 4.00 4.00 11 115 400Q160 18'-0" 12.6 315 9.2 230 6.7 168 4.00 4.00 11 125 400Q180 20'-0" 9.6 240 6.7 167 4.5 150 4.00 4.00 11 140 400Q200 17.7 443 12.7 343 9.4 235 5.00 5.00 11 185 500Q200 28.1 703 21.4 535 16.2 405 5.00 5.00 7 265 500W200 25'-0" 4.8 150 2.6 100 1.0 50 4.00 4.00 11 170 400Q250 10.8 270 7.7 188 5.4 135 4.00 4.00 7 245 400W250 9.8 245 6.3 157 3.7 150 5.00 5.00 11 225 500Q250 18.5 463 13.3 333 9.5 238 5.00 5.00 7 360 500W250 30'-0" 6.7 168 4.4 110 2.6 65 4.00 4.00 7 291 400W300 4.7 150 2.0 50 N/A N/A 5.00 5.00 11 265 500Q300 10.7 267 6.7 167 3.9 100 5.00 5.00 7 380 500W300 19.0 475 13.2 330 9.0 225 6.00 6.00 7 520 600W300 35'-0"5.9 150 2.5 100 N/A N/A 5.00 5.00 7 440 500W350 12.4 310 7.6 190 4.2 105 6.00 6.00 7 540 600W350 40'-0" 7.2 180 3.0 75 N/A N/A 6.00 6.00 7 605 600W400 DESIGNATION POLE BASE PLATE ANCHOR BOLTS POLE BASE SQUARE (IN) WALL THK (GA) BOLT CIRCLE SQUARE (IN) THK (IN) DIA x LENGTH x HOOK (IN) PROJECTION (IN) + (IN) DIA (IN) + (IN) 4.00 11 8.500.50 8.25 0.7500.75 x 17.00 x 3.00 3.50 0.25 4.00 7 8.500.50 8.25 0.8750.75 x 17.00 x 3.00 3.63 0.25 5.00 11 11.001.00 11.00 1.0000.75 x 17.00 x 3.00 3.75 0.25 5.00 7 11.001.00 11.00 1.0000.75 x 17.00 x 3.00 3.75 0.25 6.00 7 12.001.00 12.501.0001.00 x 36.00 x 4.00 4.25 0.25 0° - Handhole 270°90° 180° Bolt Circle Bolt Slots/Holes As viewed from top of pole. Anchor Base Detail DS330 Drill Mounting (See Orientation) D1 = (1) Drilling @ 270° D2 = (2) Drillings @ 90° & 270° D4 = (4) Drillings @ 0°, 90°, 180°, & 270° D5 = (2) Drillings @ 180° & 270° D6 = (3) Drillings @ 90°, 180°, & 270° Tenon Mounting P2 = 2.38" OD x 4" tenon P4 = 4.00" OD x 6" tenon P5 = 2.88" OD x 4" tenon P6 = 2.88" OD x 5" tenon P7 = 2.38" OD x 5" tenon P9 = Special Size (Specify) Other Options PC = Pole Cap PL = Plain Top (No Cap) GV = Galvanized FP = Finish Painted -----OPTIONAL----- FPGV = Finish Paint over Galvanizing VP30 = V-PRO™ 30 System VP32 = V-PRO™ 32 System VP53 = V-PRO™ 53 System VP54 = V-PRO™ 54 System VP57 = V-PRO™ 57 System VP100 = V-PRO™ 100 System VP105 = V-PRO™ 105 System GV = Galvanized BK = Black DB =Dark Bronze MB =MediumBronze WH =White LG =Light Gray CB = Bronze DG = Dark Green ST = Sandstone HTG= Hunter Green SG =Slate Gray SL =Silver SC = Special Color (Specify) FBC = Full Base Cover -----OPTIONAL----- 2T = Square Dart Cover AB = With Anchor Bolts LAB = Without Anchor Bolts Select Correct Designation from the Load and Dimensional Data Chart. DESIGNATION MODEL FIXTURE MOUNTING FINISH SYSTEM STANDARD COLOR OPTIONS BASE COVER ANCHOR BOLTS SUPPLEMENTAL INFO DS330 SPC7207 12/17 valmontstructures.com carries the most current spec information and supersedes these guidelines.Description : DS330-400Q200-D2-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SB2 400Q200 D1 FP -- -- -- PLEASE SPECIFY FINISH 11/12/19 DS330 - Fatigue Resistant Square Non-Tapered Steel Pole SPC7207 12/17 valmontstructures.com carries the most current spec information and supersedes these guidelines.VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM Description : DS330-400Q200-D2-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SB2 11/12/19 GE Evolve ™ LED Area Lighting EALS-03 & EALP-03 Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX (TYPE IV) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SC 11/12/19 Applications • Site and area light applications such as parking lots, retail exteriors, commercial exteriors, roadways and other general lighting applications Housing • Slim architectural design incorporates an integral heat sink and light engine, ensuring maximum heat transfer, and long LED life. • Die cast aluminum housing • 3G vibration per ANSI C136.31-2010 LED & Optical Assembly • LM-79 tests and reports in accordance with IESNA standards • Upward Light Output Ratio (ULOR) = 0 (horizontal orientation) • 70CRI at 3000K, 4000K and 5000K • Distributions: II, III, IV, V Lumen Maintenance • Projected Lxx per IES TM-21 at 25 °C for reference: Ratings • cUL Listed • UL 1598 Listed Suitable for Wet Locations • IP65 optical enclosure per ANSI C136.25-2013 • Operating Temperature –40°C to +40°C (maximum of +35°C for 570W) • California Title 24 compliant (w/ “H” motion sensor option) Mounting Option C1: Integral Slipfitter for 1.25”-2” Pipe (1.66 in. OD-2.378 in. OD) supplied with leads. +/- 5 deg adjustment for leveling. Option D1: Universal Mounting Arm, fitted for round or square pole mounting supplied with 16/3 3ft cable. Option K1: Knuckle Slipfitter for 1.9 in.-2.3 in. OD Tenon with leads. Restricted aiming angle 0° to +45°. Option S1: Knuckle Slipfitter for 2.3 in.- 3.0 in OD Tenon with leads. Restricted aiming angle 0° to +45°. Option V1: Knuckle Wall Mount with leads. Restricted aiming angle 0° to +45°. Finish • Corrosion resistant polyester powder paint, minimum thickness 2.0 mil. • Standard colors: Black, Dark Bronze, Aluminum, Gray & White. • RAL & custom colors available. • Optional coastal finish available. Electrical • 120-277 VAC and 347-480 VAC available. • System power factor is >90% and THD <20%. • ANSI C136.41 7-pin dimming receptacle, standard. • ANSI photo electric sensors (PE) available for all voltages. • LightGrid™ compatible. • Dimming/Occupancy: – Standard: 0-10V; Optional: DALI (120-277V, excluding 400 watts and above) – Externally wired 0-10V dimming (optional) – DALI digital dimming. Contact manufacturer for availability. – Standalone dimming occupancy sensor with ambient light sensor, option code “H”. – Daintree occupancy sensor available. • Surge Protection tested per ANSI C136.2-2015. – 6kV/3kA “Basic” surge protection, standard. – 10kV/5kA “Enhanced” surge protection optional. Warranty • 5 Year Standard Accessories • Photoelectric Controls (see page 10) • Light Shields (see Data Sheet OLP 3120 Shielding for EAL Area Light Fixtures) The EAL Area Light luminaires offer a wide range of optical patterns, color temperatures, lumen packages, and mounting configurations to optimize area light applications, as well as provide versatility in lighting design within the same form-factor. They are ideal for commercial property site-lighting applications such as retail and commercial exteriors. The EALS (standard) area light has a lumen range from 7,500-30,000 lumens. The EALP (premium) offers a similar lumen range of 25,000 to 70,000 lumens but with higher LPW and better lumen maintenance. Both the EALS-03 and EALP-03 feature our innovative, highly flexible Universal Mounting Arm option, which provides installers the ability to mount the EAL fixtures on both round and square poles of multiple sizes. In addition, it features both in-line and offset bolt patterns which enable it to easily be affixed to the majority of the bolt patterns one would encounter in the field. Product Features Note: 1) Projected Lxx based on LM80 (10,000 hour testing). 2) DOE Lighting Facts Verification Testing Tolerances apply to initial luminous flux and lumen maintenance measurements J5, K2, K3, K4, K5 L97 L96 L94 L2, L3, L4, L5, M2, M3, M4, M5 L97 L96 L94 J2, J3, J4, N2, N3, N4, N5 L94 L91 L84 P2, P3, P4, P5, Q2, Q3, Q4, Q5 L94 L91 L84 EALP03 Optical code 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours C2, C3, C4, C5, D2, D3, D4, D5 L95 L92 L86 F5, H2, H3, H4, H5 L95 L92 L86 F2, F3, F4, J2, J3, J4, J5 L94 L89 L81 K2, K3, K4, K5 L94 L89 L81 EALS03 Optical code 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours 10 1.02 20 1.01 25 1.00 30 0.99 40 0.98 Ambient Temp (°C ) Initial Flux Factor Lumen Ambient Temperature Factors: DLC Standard qualified models available. Please refer to http://www.designlights.org/QPL for complete information. DLC Premium qualified models available. Please refer to http://www.designlights.org/QPL for complete information. Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX (TYPE IV) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SC 11/12/19 E A L S 0 3 7 ______ __ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ PROD. ID VOLTAGE OPTICAL CODE CRI 0 = 120-277* 1 = 120 2 = 208 3 = 240 4 = 277 5 = 480 D = 347 H = 347-480* *Not available with Fusing. Must choose a descreet voltage with F Option 30 = 3000K‹› 40 = 4000K 50 = 5000K ‹›Select 3000K CCT for IDA Approved units SM = Symmetric Medium SW = Symmetric Wide SH = Symmetric High Angle AF = Asymmetric Forward AH = Asymmetric High Angle AW = Asymmetric Wide AN = Asymmetric Narrow/Auto N = Dimming thru PE receptacle D = External Dimming 18/2-3ft cable X = Non-dimmable* All constructions supplied with ANSI C136.41 7-pin Receptacle *Required for Cx Optical Codes. Not available for other optical codes. Note: Standard dimming 0-10V 7 = 70 (min) OPTIONSCOLOR GRAY = Gray BLCK = Black DKBZ = Dark Bronze WHTE = White MOuNTING ARM C1 = Integral Slipfitter for 1.25” - 2” Pipe (1.66in. OD - 2.378in. OD)* D1 = Universal Mounting Arm, fitted for round or square pole mounting** K1 = Knuckle Slipfitter for 1.9 in - 2.3in. OD Tenon*++ S1 = Knuckle Slipfitter for 2.3in. - 3.0in OD Tenon*++ V1 = Knuckle Wall Mount*++ * Supplied with 3FT leads ** Supplied with 3FT #14/3 power cable ++ Restricted Aiming Angle 0° to +45° CONTROLS A = ANSI 7-pin PE receptacle (no control) D = ANSI 7-pin PE receptacle with shorting cap provided Note: See accessories section on page 10 for PE Control ordering CCT DIMMING DISTRIBuTION E = Evolve AL = Area Light S = Standard Ordering Number Logic Evolve™ LED Area Light (EALS-03) GENERATION 03 = 3rd Generation C5 Symmetric Medium (SM) 7300 7500 46 B3-U0-G1 B3-U0-G1 EALS03_C5SM730_.IES EALS03_C5SM740_.IES EALS03_C5SM750_.IES D5 Symmetric Medium (SM) 9800 10000 64 B3-U0-G1 B3-U0-G1 EALS03_D5SM730_.IES EALS03_D5SM740_.IES EALS03_D5SM750_.IES F5 Symmetric Medium (SM) 14700 15000 101 B4-U0-G2 B4-U0-G2 EALS03_F5SM730_.IES EALS03_F5SM740_.IES EALS03_F5SM750_.IES H5 Symmetric Medium (SM) 19600 20000 140 B4-U0-G2 B4-U0-G2 EALS03_H5SM730_.IES EALS03_H5SM740_.IES EALS03_H5SM750_.IES J5 Symmetric Medium (SM) 24500 25000 186 B4-U0-G2 B4-U0-G2 EALS03_J5SM730_.IES EALS03_J5SM740_.IES EALS03_J5SM750_.IES K5 Symmetric Medium (SM) 29400 30000 239 B5-U0-G3 B5-U0-G3 EALS03_K5SM730_.IES EALS03_K5SM740_.IES EALS03_K5SM750_.IES C5 Symmetric Wide (SW) 7300 7500 46 B2-U0-G1 B2-U0-G1 EALS03_C5SW730_.IES EALS03_C5SW740_.IES EALS03_C5SW750_.IES D5 Symmetric Wide (SW) 9800 10100 64 B3-U0-G1 B3-U0-G1 EALS03_D5SW730_.IES EALS03_D5SW740_.IES EALS03_D5SW750_.IES F5 Symmetric Wide (SW) 14700 15100 101 B3-U0-G2 B3-U0-G2 EALS03_F5SW730_.IES EALS03_F5SW740_.IES EALS03_F5SW750_.IES H5 Symmetric Wide (SW) 19700 20200 140 B4-U0-G2 B4-U0-G2 EALS03_H5SW730_.IES EALS03_H5SW740_.IES EALS03_H5SW750_.IES J5 Symmetric Wide (SW) 24600 25200 186 B4-U0-G2 B4-U0-G2 EALS03_J5SW730_.IES EALS03_J5SW740_.IES EALS03_J5SW750_.IES K5 Symmetric Wide (SW) 29600 30300 239 B5-U0-G2 B5-U0-G2 EALS03_K5SW730_.IES EALS03_K5SW740_.IES EALS03_K5SW750_.IES C5 Symmetric High Angle (SH) 7000 7200 46 B3-U0-G1 B3-U0-G1 EALS03_C5SH730_.IES EALS03_C5SH740_.IES EALS03_C5SH750_.IES D5 Symmetric High Angle (SH) 9400 9600 64 B3-U0-G2 B3-U0-G2 EALS03_D5SH730_.IES EALS03_D5SH740_.IES EALS03_D5SH750_.IES F5 Symmetric High Angle (SH) 14200 14500 101 B4-U0-G2 B4-U0-G2 EALS03_F5SH730_.IES EALS03_F5SH740_.IES EALS03_F5SH750_.IES H5 Symmetric High Angle (SH) 18900 19300 140 B4-U0-G2 B4-U0-G2 EALS03_H5SH730_.IES EALS03_H5SH740_.IES EALS03_H5SH750_.IES J5 Symmetric High Angle (SH) 23600 24100 186 B5-U0-G3 B5-U0-G3 EALS03_J5SH730_.IES EALS03_J5SH740_.IES EALS03_J5SH750_.IES K5 Symmetric High Angle (SH) 28400 29000 239 B5-U0-G3 B5-U0-G3 EALS03_K5SH730_.IES EALS03_K5SH740_.IES EALS03_K5SH750_.IES C4 Asymmetric Forward (AF) 7300 7500 50 B1-U0-G2 B1-U0-G2 EALS03_C4AF730_.IES EALS03_C4AF740_.IES EALS03_C4AF750_.IES D4 Asymmetric Forward (AF) 9800 10000 70 B2-U0-G2 B2-U0-G2 EALS03_D4AF730_.IES EALS03_D4AF740_.IES EALS03_D4AF750_.IES F4 Asymmetric Forward (AF) 14700 15000 116 B2-U0-G2 B2-U0-G2 EALS03_F4AF730_.IES EALS03_F4AF740_.IES EALS03_F4AF750_.IES H4 Asymmetric Forward (AF) 19600 20000 140 B3-U0-G3 B3-U0-G3 EALS03_H4AF730_.IES EALS03_H4AF740_.IES EALS03_H4AF750_.IES J4 Asymmetric Forward (AF) 24500 25000 186 B3-U0-G3 B3-U0-G3 EALS03_J4AF730_.IES EALS03_J4AF740_.IES EALS03_J4AF750_.IES K4 Asymmetric Forward (AF) 29400 30000 239 B3-U0-G4 B3-U0-G4 EALS03_K4AF730_.IES EALS03_K4AF740_.IES EALS03_K4AF750_.IES C4 Asymmetric High Angle (AH) 7000 7200 50 B2-U0-G2 B2-U0-G2 EALS03_C4AH730_.IES EALS03_C4AH740_.IES EALS03_C4AH750_.IES D4 Asymmetric High Angle (AH) 9400 9600 70 B2-U0-G2 B2-U0-G2 EALS03_D4AH730_.IES EALS03_D4AH740_.IES EALS03_D4AH750_.IES F4 Asymmetric High Angle (AH) 14200 14500 116 B3-U0-G3 B3-U0-G3 EALS03_F4AH730_.IES EALS03_F4AH740_.IES EALS03_F4AH750_.IES H4 Asymmetric High Angle (AH) 18900 19300 140 B3-U0-G3 B3-U0-G4 EALS03_H4AH730_.IES EALS03_H4AH740_.IES EALS03_H4AH750_.IES J4 Asymmetric High Angle (AH) 23600 24100 186 B3-U0-G4 B3-U0-G4 EALS03_J4AH730_.IES EALS03_J4AH740_.IES EALS03_J4AH750_.IES K4 Asymmetric High Angle (AH) 28400 29000 239 B3-U0-G4 B3-U0-G4 EALS03_K4AH730_.IES EALS03_K4AH740_.IES EALS03_K4AH750_.IES C3 Asymmetric Wide (AW) 7300 7500 50 B2-U0-G1 B2-U0-G1 EALS03_C3AW730_.IES EALS03_C3AW740_.IES EALS03_C3AW750_.IES D3 Asymmetric Wide (AW) 9800 10100 70 B2-U0-G2 B2-U0-G2 EALS03_D3AW730_.IES EALS03_D3AW740_.IES EALS03_D3AW750_.IES F3 Asymmetric Wide (AW) 14700 15100 116 B2-U0-G2 B2-U0-G2 EALS03_F3AW730_.IES EALS03_F3AW740_.IES EALS03_F3AW750_.IES H3 Asymmetric Wide (AW) 19700 20200 140 B3-U0-G2 B3-U0-G3 EALS03_H3AW730_.IES EALS03_H3AW740_.IES EALS03_H3AW750_.IES J3 Asymmetric Wide (AW) 24600 25200 186 B3-U0-G3 B3-U0-G3 EALS03_J3AW730_.IES EALS03_J3AW740_.IES EALS03_J3AW750_.IES K3 Asymmetric Wide (AW) 29600 30300 239 B3-U0-G3 B3-U0-G3 EALS03_K3AW730_.IES EALS03_K3AW740_.IES EALS03_K3AW750_.IES C2 Asymmetric Narrow/Auto (AN) 7300 7500 50 B2-U0-G2 B2-U0-G2 EALS03_C2AN730_.IES EALS03_C2AN740_.IES EALS03_C2AN750_.IES D2 Asymmetric Narrow/Auto (AN) 9800 10100 70 B2-U0-G2 B2-U0-G2 EALS03_D2AN730_.IES EALS03_D2AN740_.IES EALS03_D2AN750_.IES F2 Asymmetric Narrow/Auto (AN) 14700 15100 116 B3-U0-G3 B3-U0-G3 EALS03_F2AN730_.IES EALS03_F2AN740_.IES EALS03_F2AN750_.IES H2 Asymmetric Narrow/Auto (AN) 19700 20200 140 B3-U0-G3 B3-U0-G3 EALS03_H2AN730_.IES EALS03_H2AN740_.IES EALS03_H2AN750_.IES J2 Asymmetric Narrow/Auto (AN) 24600 25200 186 B3-U0-G3 B3-U0-G3 EALS03_J2AN730_.IES EALS03_J2AN740_.IES EALS03_J2AN750_.IES K2 Asymmetric Narrow/Auto (AN) 29600 30300 239 B3-U0-G3 B3-U0-G3 EALS03_K2AN730_.IES EALS03_K2AN740_.IES EALS03_K2AN750_.IES OPTICAL CODE TYPE DISTRIBuTION 4000K & 5000K3000K 120-277V & 347-480V TYPICAL INITIAL LuMENS TYPICAL SYSTEM WATTAGE 3000K B-u-G 4000 & 5000K B-u-G 3000K IES FILE NuMBER 4000K IES FILE NuMBER 5000K IES FILE NuMBER BuG RATING Type V Type IV Type III Type II Pole Right (S2) Pole Left (S1) F = Fusing H = Motion Sensor (Sensor Switch) H2 = Motion Sensor (Daintree) J = cUL/Canada L = Tool-Less Entry R = Enhanced Surge Protection (10kV/5kA) S1 = Rotated Left † S2 = Rotated Right † T = Elevated Surge Protection (20kV/10kA) u = DALI dimming ^+ V = 3-Position Terminal Block Y = Coastal Finish XXX = Special Options * Contact Manufacturer for availability + Compatible with LightGrid 2.0 nodes^Notcompatibleat347-480V or with motion sensor control †Foraimedleftorrightlightdistribution orientation, as assembled in manufacturing. NotapplicableforSymmetricDistributions. Note: H2optionnotavailableat370V-480V Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX (TYPE IV) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SC PLEASE SPECIFY VOLTAGE PLEASE SPECIFY FINISH 11/12/19 Photometrics Evolve™ LED Area Light (EALS-03) EALS Type II - Asymmetric Narrow/Auto 30,300 Lumens, 5000K (EALS03_K2AN750___.IES) EALS Type VS - Symmetric High Angle 29,000 Lumens, 5000K (EALS03_K5SH750___.IES) EALS Type III - Asymmetric Wide 30,300 Lumens, 5000K (EALS03_K3AW750___.IES) EALS Type VS - Symmetric Medium 30,000 Lumens, 5000K (EALS03_K5SM750___.IES) EALS Type IV - Asymmetric Forward 30,000 Lumens, 5000K (EALS03_K4AF750___.IES) EALS Type VS - Symmetric Wide 30,300 Lumens, 5000K (EALS03_K5SW750___.IES) EALS Type IV - Asymmetric High Angle 29,000 Lumens, 5000K (EALS03_K4AH750___.IES) Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 55° Vertical plane through horizontal angle of 34° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 58° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 20° Vertical plane through horizontal angle of 58° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 70° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 50° Vertical plane through horizontal angle of 69° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 65° Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 50° Vertical plane through horizontal angle of 55° .1 .2 .5 3642 7284 10926 14569 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4014 8028 12043 16057 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4580 9161 13741 18321 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 4483 8966 13449 17931 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2.5 2544 5089 7633 10178 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 2619 5239 7858 10478 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS .1 .2 .5 2561 5121 7682 10243 1 2 COEFFICIENTS OF UTILIZATION 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 1 2 3 4 5 Street Width / Mounting Height SS HS Description : EALS-03-XX-F4-AH-7-40-N-D-D1-XX (TYPE IV) Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SC 11/12/19 Pole Cap - Plastic Poles - Steel SSS / DS330 Fatigue ResistantSPECIFICATIONS Pole Shaft - The pole shaft is fabricated from hot rolled welded steel tubing of one-piece construction with a minimum yield strength of 55 KSI. Pole Top – A removable pole cap is provided for poles receiving drilling patterns for side-mount luminaire arm assemblies. For top mount luminaire and/or bracket consult the factory. Consult the luminaire manufacturer for correct tenon size or drill pattern. Other pole top options include pole cap only (PC) or plain top (PL) which is typical when the pole top diameter matches the necessary slip fit dimensions. Handhole – A reinforced handhole with grounding provision is provided at 1’-6” from the base end of the pole assembly. Each handhole includes a cover and the cover attachment hardware. All pole assemblies are provided with a 2.5” x 5” rectangular handhole. Handhole dimensions are nominal. Base Cover – A two-piece full base cover fabricated from ABS plastic is provided with each pole assembly. Additional base cover options, including the dart square (2T) cast aluminum cover, are available upon request. Anchor Bolts - Anchor bolts conform to ASTM F1554 Grade 55 and are provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and are galvanized a minimum of 12” on the threaded end. Hardware - All structural fasteners are galvanized high strength carbon steel. All non-structural fasteners are galvanized or zinc-plated carbon steel or stainless steel. Finish - Standard finishes are either Galvanized (GV) or Finish Painted (FP). Additional finish options including Finish Paint over Galvanizing (FPGV) or any of the V-PROTM Finish Coating Systems are available upon request. See the product ordering code for color options. Design Criteria - Please reference Design Criteria Specification for appropriate design conditions. VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM SOFT SQUARE STEEL DS330 Fatigue Resistant Job Name: Job Location - City: State: Product: Quote: Client Name: Created By: Date: Customer Approval: Date: Cross Section Handhole Full Base Cover (Standard) Handhole 1’-6” Nominal Mounting HeightTenon Top* * Consult factory on loading criteria for pole top mounted luminaires and/or brackets. Dart Square - 2T (Optional) Soft Square Description : DS330-400Q200-D1-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SC 11/12/19 DESIGNATION, LOAD AND DIMENSIONAL DATA VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM SOFT SQUARE STEEL DS330 Fatigue Resistant 1. Maximum EPA (Effective Projected Area) and weight values are based on side mounted fixtures only. Consult factory on loading criteria for pole top mounted luminaires and/or brackets. Variations from sizes above are available upon inquiry at the factory. Satisfactory performance of poles is dependent upon the pole being properly attached to a supporting foundation of adequate design. 2. Structure weight is a nominal value which includes the pole shaft and base plate only. 3. Belled-bottom will have reduced thickness due to the cold-working process. However, the belled-bottom meets or exceeds the structural capacity of the original square section. In addition, the rounded section provides better fatigue resistance. Job Name: Job Location - City: State: Product: Quote: Client Name: Created By: Date: Customer Approval: Date:Poles - Steel SSS / DS330 Fatigue ResistantSTANDARD ORDERING CODE STRUCTURE ANCHORAGE DATA POLE BASE PLATE ANCHOR BOLTS POLE BASE SQUARE (IN) WALL THK (GA) BOLT CIRCLE SQUARE (IN) THK (IN) DIA x LENGTH x HOOK (IN) PROJECTION (IN) + (IN) DIA (IN) + (IN) 4.00 11 8.50 0.50 8.25 0.750 0.75 x 17.00 x 3.00 3.50 0.25 4.00 7 8.50 0.50 8.25 0.875 0.75 x 17.00 x 3.00 3.63 0.25 5.00 11 11.00 1.00 11.00 1.000 0.75 x 17.00 x 3.00 3.75 0.25 5.00 7 11.00 1.00 11.00 1.000 0.75 x 17.00 x 3.00 3.75 0.25 6.00 7 12.00 1.00 12.50 1.000 1.00 x 36.00 x 4.00 4.25 0.25 Anchor Base Detail Bolt Circle Bolt Slots/Holes 0° - Handhole 270°90° 180° As viewed from top of pole. DESIGNATION FIXTURE MOUNTING FINISH SYSTEM ANCHOR BOLTS BASE COVER MODEL DS330 Drill Mounting (See Orientation) D1 = (1) Drilling @ 270° D2 = (2) Drillings @ 90° & 270° D4 = (4) Drillings @ 0°, 90°, 180°, & 270° D5 = (2) Drillings @ 90° & 180° D6 = (3) Drillings @ 90°, 180°, & 270° Tenon Mounting P2 = 2.38” OD x 4” tenon P4 = 4.00” OD x 6” tenon P5 = 2.88” OD x 4” tenon P6 = 2.88” OD x 5” tenon P7 = 2.38” OD x 5” tenon P9 = Special Size (Specify) Other Options PC = Pole Cap PL = Plain Top (No Cap) GV = Galvanized FP = Finish Painted -----OPTIONAL----- FPGV = Finish Paint over Galvanizing VP30 = V-PRO™ 30 System VP32 = V-PRO™ 32 System VP53 = V-PRO™ 53 System VP54 = V-PRO™ 54 System VP57 = V-PRO™ 57 System VP100 = V-PRO™ 100 System VP105 = V-PRO™ 105 System GV = Galvanized BK = Black DB = Dark Bronze MB = Medium Bronze WH =White LG =Light Gray CB = Bronze DG = Dark Green ST = Sandstone HG = Hunter Green SG = Slate Gray SL = Silver SC = Special Color (Specify) FBC = Full Base Cover -----OPTIONAL----- 2T = Square Dart Cover AB = With Anchor Bolts LAB = Without Anchor Bolts SUPPLEMENTAL INFO Select Correct Designation from the Load and Dimensional Data Chart. STANDARD COLOR OPTIONS 90° DESIGN INFORMATION POLE DIMENSIONS3 NOMINAL MOUNTING HEIGHT 80 MPH w/1.3 GUST 90 MPH w/1.3 GUST 100 MPH w/1.3 GUST SHAFT BASE SQUARE3 (IN) SHAFT TOP SQUARE (IN) WALL THK (GA) STRUCTURE WEIGHT 2 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) MAX EPA1 (SQ FT) MAX WEIGHT1 (LBS) 10'-0" 30.6 765 23.8 595 18.9 473 4.00 4.00 11 75 400Q100 12'-0" 24.4 610 18.8 470 14.8 370 4.00 4.00 11 90 400Q120 14'-0" 19.9 498 15.1 378 11.7 293 4.00 4.00 11 100 400Q140 16'-0" 15.9 398 11.8 295 8.9 223 4.00 4.00 11 115 400Q160 18'-0" 12.6 315 9.2 230 6.7 168 4.00 4.00 11 125 400Q180 20'-0" 9.6 240 6.7 167 4.5 150 4.00 4.00 11 140 400Q200 17.7 443 12.7 343 9.4 235 5.00 5.00 11 185 500Q200 28.1 703 21.4 535 16.2 405 5.00 5.00 7 265 500W200 25'-0" 4.8 150 2.6 100 1.0 50 4.00 4.00 11 170 400Q250 10.8 270 7.7 188 5.4 135 4.00 4.00 7 245 400W250 9.8 245 6.3 157 3.7 150 5.00 5.00 11 225 500Q250 18.5 463 13.3 333 9.5 238 5.00 5.00 7 360 500W250 30'-0" 6.7 168 4.4 110 2.6 65 4.00 4.00 7 291 400W300 4.7 150 2.0 50 N/A N/A 5.00 5.00 11 265 500Q300 10.7 267 6.7 167 3.9 100 5.00 5.00 7 380 500W300 19.0 475 13.2 330 9.0 225 6.00 6.00 7 520 600W300 35'-0"5.9 150 2.5 100 N/A N/A 5.00 5.00 7 440 500W350 12.4 310 7.6 190 4.2 105 6.00 6.00 7 540 600W350 40'-0" 7.2 180 3.0 75 N/A N/A 6.00 6.00 7 605 600W400 DESIGNATION Description : DS330-400Q200-D1-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SC 400Q200 D1 FP -- FBC AB 11/12/19 38 DS330 Fatigue Resistant Square Non-Tapered VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM SPC7207 03/16 valmontstructures.com carries the most current spec information and supersedes these guidelines.Description : DS330-400Q200-D1-FP-XX-FBC-AB Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: SC 11/12/19 GE Evolve™ LED L-Series Wall Pack EWLS Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA 11/12/19 To learn more about GE Evolve LED L-Series Wall Pack, go to: http://products.currentbyge.com The Evolve LED L-Series Wall Pack, EWLS, is a designed replacement for 50W to 250W HID, while offering significant energy savings in a long-life LED wall pack. The EWLS's 2-screw housing design enables a fast and simplified installation. The low-watt Egress package (13W) is designed to meet recommended illuminance requirements for egress applications such as side and rear exit doors in commercial buildings and can meet NFPA 101 life safety lighting requirements when used with external battery backup. • 1500 and 4000 lumen output • High Brightness LEDs • 70 CRI @ 3000K, 4000K, and 5000K typical • L90 > 100,000 hours (1500lm), L90 > 60,000 hours (4000lm) • Designed to replace 50W to 250W MH wallpacks • Small Form Factor, <10 lbs • 0-10V Dimming • Motion Sensor & Button Photo Electric Sensors available • Impact resistant tempered glass lens • Zero up-light construction, full cut-off • International Dark-Sky Association (IDA) Approved for 3000K CCT • Building entrances & perimeter lighting • Side and rear exit doors • Stairways and entry path • Schools, Apartment Buildings, Hospitals • Retail & Commercial Buildings • Loading docks 2 GE Evolve™ LED L-Series Wall Pack EWLS Features: Applications: Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA 11/12/19 3 Typical Specifications: EWLS LED & Optical • Lumen Packages: 1500 & 4000 • System Efficacy: Up to 125 lpw • CCT: 3000K, 4000K, 5000K; High brightness LEDs. • CRI: 70 • Upward Light Output Ratio (ULOR) = 0. • Custom engineered reflective optics for optimized photometry. • High application efficiency and minimal glare. Electrical • Input Voltage: 120-277 volt and 347 volt • Input Frequency: 50/60Hz • Power Factor (PF): >90% • Total Harmonic Distortion (THD): <20% • Surge Protection: Integral surge protection Ratings • Operating Temperature: –40° to 50°C • Storage Temperature: –40° to 50°C • Location: Dry or Wet • Safety: UL/cUL Listed. UL 1598 listed, suitable for wet locations. • DLC Premium & Standard qualified models available. Please refer to http://www.designlights.org/QPL for complete information. • Environmental: Compliant with the materials restrictions of RoHS. • LM-79 testing in accordance with IESNA Standards. • Optical enclosure IP66 per ANSI C136.25-2009. Lumen Maintenance • Projected L90>100,000 hours per IES TM-21 for 15AF optical codes. • Projected L90>60,000 hours per IES TM-21 for 40AF optical codes. • Projected Lxx per IES TM-21 at 25°C for reference: Construction & Finish • Housing: — Die-cast aluminum. Integrated heat sink for maximum heat transfer. — Patented aesthetic design to complement your building façade. • Lens: Impact resistant tempered glass lens. • Paint: Corrosion resistant polyester powder painted, minimum 2.0 mil. thickness. — Standard Colors: Dark Bronze, Black, White, Gray — RAL & custom colors available. • Weight: 8.5lbs (4 kg) Warranty • System Warranty: 5 Year Standard, 10 Year Optional. Controls • Dimming: Wired Analog 0-10V Dimming.1 • Sensors: — Button Photo Electric sensor (PE) available 120-277V & 347V. — CA Title 24 Compliant Occupancy Sensor Option.1 1 Available with Optic Code 40AF Mounting • Mounts to standard 3-1/2” to 4” round and octagonal, 4” square, single gang and masonry junction boxes. — Flush Mount: Mounts directly to customer supplied junction box. — Conduit Box Mount: Mounts to walls via separate mounting box with conduit knockouts. Sensor Pattern: Sensing Pattern Wall Pack Fixture: 8-25 ft. / GE Evolve™ LED L-Series Wall Pack EWLS Project name _________________ Date ________________________ Type ________________________ 40AF L95 L92 L85 Optical Codes 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours** 15AF L96 L95 L91 Optical Codes 25,000 hr 50,000 hr 100,000 hr Lxx (10k) @ Hours** Note: *Projected Lxx based on LM80 (10,000 hour testing). DOE Lighting Facts Verification Testing Tolerances apply to initial luminous flux and lumen maintenance measurements. Street Side 40’ 30’ 20’ 10’ 10’ 20’ 30’ 40’ Vehicles Pedestrians 40’ 30’ 20’ 10’ Subject to Change Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA 11/12/19 E W L S 0 1 7____ __ _ _ _ _ __ _ _ _ _ _ __ _ _ _ _ PRODUCT VOLTAGE GENERATION OPTICAL CODE 0 = 120-277V* 1 = 120» 2 = 208» 3 = 240» 4 = 277» D = 347» » Specify single voltage if Button PE option selected 01 = Generation 15AF = 1500lm, Asymmetric Forward 40AF = 4000lm, Asymmetric Forward OPTIONSCOLOR MOUNTING CONTROLS DIMMING CCT CRI H = Motion Sensor+ ### = Special Options J = cUL/Canada W = Non-Graphical White Box DKBZ = Dark Bronze* BLCK =Black GRAY =Gray WHTE = White FM = Flush Mount* CB = Conduit Box Mount** **Must be selected when ordering with Button PE,Motion Sensor, or 347V *Standard Option + = Motion Sensor not available at 1500lm 1 = None* 3 = Button PE◊ ◊ Must specify discrete voltage N = Non-Dimming D = Dimming* Leads ‡ ‡ Dimming not available at 1500lm 30 = 3000K‹› 40 = 4000K* 50 = 5000K ‹› Select 3000K CCT for IDA Approved units E = Evolve W = Wallpack L = L-series S = Standard 7 = 70 CRI* GE Evolve™ LED L-Series Wall Pack EWLS Project name _________________ Date ________________________ Type ________________________ Claims Table: E = Evolve W = Wallpack L = L-series S = Standard A = Accessory E = Escutcheon Plate 1 = 10” x 12” 2 =12”x 16” 3 =12”x 20” DKBZ = Dark Bronze* BLCK = Black GRAY= Gray WHTE = White RAL customer colors available. Contact Manufacturer PRODUCT ID DETAIL FINISH E = Evolve W = Wallpack L = L-series S = Standard A = Accessory D = Diffuser PRODUCT ID DETAIL Accessories: Motion Sensing Option: 4 OPTICAL CODE DIST.3000K 3000K 3000K 3000K4000K 4000K 4000K 4000K/5000K5000K5000K 5000K 120-277V 347V TYPICAL SYSTEM WATTS TYPICAL INITIAL LUMENS TYPICAL INITIAL LPW 120-277V TYPICAL INITIAL LPW 347V BUG RATING 15 AF 12 13 1,450 1,500 1,500 121 125 125 112 112 115 B1-U0-U0 B1-U0-U0 40 AF 37 38 3,880 4,000 4,000 105 108 108 102 105 105 B1-U0-U0 B1-U0-U0 IES FILE NAME 120-277V CCT IES FILE NAME 347V EWLS01_15AF730_____-120-277V.IES EWLS01D15AF730_____-347V.IES EWLS01_15AF740_____-120-277V.IES EWLS01D15AF740_____-347V.IES EWLS01_15AF750_____-120-277V.IES EWLS01D15AF750_____-347V.IES EWLS01_40AF730_____-120-277V.IES EWLS01D40AF730_____-347V.IES EWLS01_40AF740_____-120-277V.IES EWLS01D40AF740_____-347V.IES EWLS01_40AF750_____-120-277V.IES EWLS01D40AF750_____-347V.IES 3000K 4000K 5000K 3000K 4000K 5000K • Intended for 8-25 ft. mounting heights. • Provides a coverage area radius for walking motion of 25-30 ft. • Provides 180° of coverage (~180° is blocked by the wall). • Factory preset to 50% dimming with no occupancy. • May be reprogrammed using additional remote programmer. — Remote progammer part number: WS FSIR-100 PROGRAMMER (197634) • Photoelectric control is integrated through the motion sensor, and is offered as standard. MODELS AVAILABLE THROUGH QUICKSHIP PROGRAM SKU # CAT LOGIC DESCRIPTION 93056860 EWLS01015AF740N1FMDKBZ 1500lm, 4000K, Flush Mount 93060201 EWLS01015AF750N1FMDKBZ 1500lm, 5000K, Flush Mount 93059497 EWLS01040AF740N1FMDKBZ 4000lm, 4000K, Flush Mount 93060200 EWLS01040AF750N1FMDKBZ 4000lm, 5000K, Flush Mount 93060202 35-434281R01 Conduit Box Mount (QTY 1) 93060203 35-966640-01 Conduit Box Mount (QTY 5) Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA PLEASE SPECIFY VOLTAGE PLEASE SPECIFY FINISH 11/12/19 GE Evolve™ LED L-Series Wall Pack EWLS Product Dimensions: Flush Mount Conduit Box Mount 5 7.366 4.800 1.000 1.020 6.320 8.266 3.853 Gasket 1/2 “ Conduit Knock Out 3 Places Button PE Option 4.300 1.750 8.267 Gasket 4.300 4.800 1.750 1.6900.970 45° 1.750 1.372 8.267 0.190 TYP 8.266 4.300 1.3751.750 Gasket Motion Sensor Option Button PE Option 1.750 0.190 0.970 1.688 45° 7.366 3.853 Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA 11/12/19 GE Evolve™ LED L-Series Wall Pack EWLS Photometrics: 15AF: 1500 LUMEN, ASYMMETRIC FORWARD EWLS01_15AF750________-120-277V.ies 40AF: 4000 LUMEN, ASYMMETRIC FORWARD EWLS01_40AF750________-120-277V.ies 6 174 348 523 697 1 2 .5 1 2 374 748 1122 1496 1 2 .5 1 2 2 Foot Candle SHOWN AT 10' MOUNTING HEIGHT FOR DISPLAY PURPOSED ONLY 1 Foot Candle 0.5 Foot Candle Grid Distance in Units of Mounting Height at 10’ Initial Foot-candle Values at Grade. Grid Distance in Units of Mounting Height at 10’ Initial Foot-candle Values at Grade. # 1 - Vertical plane through horizontal angle of maximum candlepower at 0° # 2 - Vertical plane through horizontal angle of 14° # 1 - Vertical plane through horizontal angle of maximum candlepower at 0° # 2 - Vertical plane through horizontal angle of 36° 2 Foot Candle SHOWN AT 10' MOUNTING HEIGHT FOR DISPLAY PURPOSED ONLY 1 Foot Candle 0.5 Foot Candle Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA 11/12/19 GE Evolve™ LED L-Series Wall Pack EWLS 7 Figure 1: Wall Plate Install Figure 2: Mounting Box Install Wall Plate Housing Wall Gasket Housing Gasket Housing Wall Gasket Housing Gasket Mounting Box Knockout Plug Consult product Installation Instructions (GEH 6060) for detailed installation instructions. Accessories: Beauty Plates Cover the unsightly debris marks on your building façade with color matched wall pack beauty plates. Mounting hole patterns and dimensions are compatible with typical building surface fastening methods. Criterion Small Criterion DM Wallighter 175 Wallmount 250/175 Wallighter 70 Wallmount 100 Medium Beauty Plate 12x16 Small Beauty Plate 10x12 Large Beauty Plate 12x20 Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA 11/12/19 GE Evolve™ LED L-Series Wall Pack EWLS Accessories: Mounting Holes 8 Mounting hole patterns and dimensions are compatible with typical building surface fastening methods. Diffuser Optional diffuser accessory utilizing ACRYLITE®, an acrylic sheet with an elegant texture which performs double duty with beauty and durability for any environment. This added texture diffuses surface reflections. Transmits 90% of the light through diffuser. All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. © 2017 GE. www.currentbyge.com OLP3127 (Rev 05/02/17) 12.000 20.000 5.125 4.625 10.000 8.000 4.625 5.125 10.000 O0.221 4 Places / O0.221 4 Places / 6.000 10.000 12.000 16.000 5.125 4.625 O0.221 4 Places / 6.000 10.000 16.000 Description : EWLS-01-VOLT-40AF-7-40K-N-1-FM-FINISH Project Name: CARMEL REHABILITATION HOSPITAL Notes: TYPE: WA 11/12/19