HomeMy WebLinkAboutCLAY CORNER 50 - CC050 (AS DESIGNED)IECC 2009 Performance Compliance Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON (B) Community: CLAY CORNER 50 CC050 (AS DESIGNED) CLAY CORNER 50 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,290 S210 S385 $1,885 S570 SO $2,555 Requirements C-M, Energy Solutions As Designed S1,135 S 172 S385 $1,693 S670 S0 $2,363 C4405.3 Performance -based compliance passes by 10.2% R402.4.12 Air Leakage Testing Air sealing is S.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 10.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9117119 at 1:00 PM Ekotrope RATER - Version 3.1.0.2253 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 1509 JENSEN DR CARMEL, IN 46032 Builder: LENNAR HOMES �J PTO Pi Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 150 CFM25 (4.881100 s.f.) Total Duct Leakage 240 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9/17119 at 1:00 PM Ekotrope RATER - Version 3.1.0.2253 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 1509 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (B) Community: CLAY CORNER 50 Builder LENNAR HOMES CC050 (AS DESIGNED) CLAY CORNER 50 General Building Information Conditioned Area (sq ft) 3,074 Conditioned Volume (cubic ft) 26,731 Insulated Shell Area (sq ft) 7,410 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (2,139 s.f., 217 ft. exterior perimeter) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB 2X4 (2,413 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (408 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property organization 1509 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (B) Community: CLAY CORNER 50 Builder LENNAR HOMES CC050 (AS DESIGNED) CLAY CORNER 50 El Name: BAND CONDIAMB (67 s.f.) R: 13.575 Roof Name: CONDIATTIC (64 s.f.) R: 13.575 Name: SECOND (2,139 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (24 s.f.) U: 0.182 Name: GARAGE (18 s.f. ) U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT (120 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH El Name: BACK(90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH Name: LEFT SIDE (93 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: LEFT SIDE GD (20 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST E] Name: RIGHT SIDE (73 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST E] Name: BSMT (16 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST Skylight None Present C", Energy Solutions 2 Energy Code Inspection Checklist Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON (13) Community: CLAY CORNER 50 CC050 (AS DESIGNED) CLAY CORNER 50 Mechanical Ventilation None Present Mechanical Equipment Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 2,228 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 150 CFM25 (4.88 / 100 s.f.) Total Leakage specified as: 240 CFM25 (Post -Construction) C", Energy Solutions 3 Energy Code Inspection Checklist Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON (13) Community: CLAY CORNER 50 CC050 (AS DESIGNED) CLAY CORNER 50 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5N5 4 Building Summary Property Energy Solutions Organization Inspection Status C-M 1509 JENSEN DR TSI Energy Solutions Results are projected CARIAEL, IN 46032 Matthew Timmons Model: PENNINGTON (B) Community: CLAY CORNER 50 Builder LENNAR HOMES CC050 [AS DESIGNED] CLAY CORNER 50 GenerAuilding Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 3;074 Unconditioned, attached garage? Yes Conditioned Volume [Cu- ft.] 26;731 Total Units in Building 1 Residence Type Single family detached Floor Number Model PENNINGTON (B) Community CLAY CORNER 50 Climate Zone 5A Foundation Wall None Present Foundation Wall Library List None Present Slab Masonry Area n SLAB R-10, 2'down 217 On Grade 0 0 2:139.0 f[' Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value IR-10, 2'down Wood Frame / Other No 0 2 10 No 0.00 Framed Floor None Present 1 Building Summary Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [B] Community: CLAY CORNER 50 CC050 [AS DESIGNED] CLAY CORNER 50 Framed Floor Library1�" Rim Joist Name BAND CONDIAMB CONDIATTIC Rim Joist Library List Name G1 R-13. R-3.0 C-M Energy Solutions Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES G1 R-13, R-3.0 670 ff Exposed Exterior G1 R-13, R-3.0 64.0 ft' Attic 13.575 Surface Area Location CONDIAMB 2X4 G1 R-13 BATT, R-3.0 Medium 2,413.0 ft' Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3-0 Medium 408.0 ft' Attic CONDIGAR G1 R-13 Gar Walls Medium 180.0 T12 Unconditioned, attached garage Wall Library List Name Effective R-value G1 R-13 BATT, R-3.0 15.12 IG1 R-13 Gar Walls 11.141 2 Building Summary C-M Energy Solutions Property Organization Inspection Status 1509 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON [B] Community: CLAY CORNER 50 Builder LENNAR HOMES CC050 [AS DESIGNED] CLAY CORNER 50 Glazin Name Library Type Wall ASSlgnment FDIlndatTOn wall Overhang Delon Assignment Overhang Ft To Top Overhang Ft TO Bottom Orientation surface Area BACK 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ North 90.0 f, BSMT 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ East 16.0 fF FRONT 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ South 1200.ft2 LEFT SIDE 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ West 93.0 fF LEFT SIDE GD U-.33, SHGG28 CONDIAMB 2X4 0 0 0 West 20.0 ff RIGHT SIDE U-.33, SHGG28 CONDIAMB 2X4 0 0 0 East 73.0 fF Glazing Library List Name Shgc U -factor U-.33, SHGC-28 028 0.330 Skylight None Present Skylight Library List None Present Opaque Door Name Library Type Wall Assignment Foundation Wall Emlttance Solar Surface Color surface Area Location Assignment Absorptance FRONT Fiberglass Door CONDIAMB 2X4 0.9 0.75 Medium 24.0 f' Exposed Exterior GARAGE Fiberglass Door CONDIGAR 0.9 0.75 Medium 18.0 fts Exposed Exterior Building Summary Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [B] Community: CLAY CORNER 50 CC050 [AS DESIGNED] CLAY CORNER 50 Opaque Door Library List Name Fiberglass Door Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 0.182 Inspection Status Results are projected C-M, Energy Solutions Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location V11.1 Tiles SECOND R-38 Blown, GR1 2,139 No Medium 2,139.0 fls Attic Roof Insulation Library List Name Has Radiant Barrier Effective R-value '•0 ? :a l No 38268 Whole House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation M None Present 1 Lighting % Interior Fluorescent % Interior LED Lighting % Exter Lighting ❑ 100 Shelter Class 4 or Fluorescent % Exterior LED Lighting % Garage Fluorescent Lighting Lighting 0 100 ❑ 100 4 Building Summary Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [B] Community: CLAY CORNER 50 CC050 [AS DESIGNED] CLAY CORNER 50 Onsite Generation Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Gnsite Generation Library List I None Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Inspection Status Results are projected C-M, Energy Solutions Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location Air conditioner 4AC`42P 0% 100% ❑% Conditioned Space Fuel -fired air 915SA4206OS17 100% 0% ❑% Conditioned Space distribution Water Heating RE350` 0% 0% 100% Conditioned Space Equipment Type: 4AC*42P Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 A Building Summary Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [B] Community: CLAY CORNER 50 CC050 [AS DESIGNED] CLAY CORNER 50 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Equipment Type: 915SA4206OS17 Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Natural Gas Forced Air PSG (Single Speed) 95.5 AFUE 58 No 636 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 ❑.99 C-M, Energy Solutions Building Summary Property Energy Solutions Organization Inspection Status C-M 1509 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON [B] Community: CLAY CORNER 50 Builder LENNAR HOMES CC050 [AS DESIGNED] CLAY CORNER 50 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 3074 # Return Grilles 3 Supply Duct R Value 10 Return Duct R Value 10 Supply Duct Area r] 829.98 Return Duct Area [ft2] 461.1 Leakage to Outdoors 150 CFM25 (4.881 100 s.f.) Total Leakage 240 CFM25 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ rCeiling Fan W Has Ceiling Fan No Cfm Per Watt 101 7 Building Summary Property 1509 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [B] Community: CLAY CORNER 50 CC050 [AS DESIGNED] CLAY CORNER 50 Water Distribution MM Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption r5N5 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Standard No 65 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions ,�