HomeMy WebLinkAboutCLAY CORNER 50 - CC050 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (B)
Community: CLAY CORNER 50
CC050 (AS DESIGNED)
CLAY CORNER 50
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,290
S210
S385
$1,885
S570
SO
$2,555
Requirements
C-M,
Energy Solutions
As Designed
S1,135
S 172
S385
$1,693
S670
S0
$2,363
C4405.3 Performance -based compliance passes by 10.2%
R402.4.12 Air Leakage Testing Air sealing is S.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U-Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 10.2%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
9117119 at 1:00 PM
Ekotrope RATER - Version 3.1.0.2253
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
1509 JENSEN DR
CARMEL, IN 46032
Builder: LENNAR HOMES
�J PTO Pi
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U-Value: 0.33, SHGC: 0.28
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 150 CFM25 (4.881100 s.f.)
Total Duct Leakage 240 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 9/17119 at 1:00 PM
Ekotrope RATER - Version 3.1.0.2253
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
1509 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (B)
Community: CLAY CORNER 50 Builder
LENNAR HOMES
CC050 (AS DESIGNED)
CLAY CORNER 50
General Building Information
Conditioned Area (sq ft) 3,074
Conditioned Volume (cubic ft) 26,731
Insulated Shell Area (sq ft) 7,410
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,139 s.f., 217 ft. exterior perimeter)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB 2X4 (2,413 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (408 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Energy Code Inspection Checklist
Property organization
1509 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (B)
Community: CLAY CORNER 50 Builder
LENNAR HOMES
CC050 (AS DESIGNED)
CLAY CORNER 50
El Name: BAND CONDIAMB (67 s.f.)
R: 13.575
Roof
Name: CONDIATTIC (64 s.f.)
R: 13.575
Name: SECOND (2,139 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.182
Name: GARAGE (18 s.f. )
U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT (120 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH
El Name: BACK(90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH
Name: LEFT SIDE (93 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
El Name: LEFT SIDE GD (20 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
E] Name: RIGHT SIDE (73 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST
E] Name: BSMT (16 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST
Skylight
None Present
C",
Energy Solutions
2
Energy Code Inspection Checklist
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (13)
Community: CLAY CORNER 50
CC050 (AS DESIGNED)
CLAY CORNER 50
Mechanical Ventilation
None Present
Mechanical Equipment
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 2,228 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 150 CFM25 (4.88 / 100 s.f.)
Total Leakage specified as: 240 CFM25 (Post -Construction)
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (13)
Community: CLAY CORNER 50
CC050 (AS DESIGNED)
CLAY CORNER 50
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
5N5
4
Building Summary
Property
Energy Solutions
Organization Inspection Status C-M
1509 JENSEN DR
TSI Energy Solutions Results are projected
CARIAEL, IN 46032
Matthew Timmons
Model: PENNINGTON (B)
Community: CLAY CORNER 50
Builder
LENNAR HOMES
CC050 [AS DESIGNED]
CLAY CORNER 50
GenerAuilding Information
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
3;074
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu- ft.]
26;731
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
PENNINGTON (B)
Community
CLAY CORNER 50
Climate Zone
5A
Foundation Wall
None Present
Foundation Wall Library List
None Present
Slab
Masonry Area
n
SLAB R-10, 2'down 217
On Grade 0
0 2:139.0 f[' Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Slab Completel Underslab Perimeter
Perimeter Thermal Break
Effective R-value
Type Insulated. Insulation
Width [ft] Insulation Depth [ft]
Insulation R Value
IR-10, 2'down Wood Frame / Other No
0 2
10 No
0.00
Framed Floor
None Present
1
Building Summary
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [B]
Community: CLAY CORNER 50
CC050 [AS DESIGNED]
CLAY CORNER 50
Framed Floor Library1�"
Rim Joist
Name
BAND CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-13. R-3.0
C-M
Energy Solutions
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
G1 R-13, R-3.0 670 ff Exposed Exterior
G1 R-13, R-3.0 64.0 ft' Attic
13.575
Surface Area Location
CONDIAMB 2X4
G1 R-13 BATT, R-3.0 Medium
2,413.0 ft' Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R-3-0 Medium
408.0 ft' Attic
CONDIGAR
G1 R-13 Gar Walls Medium
180.0 T12 Unconditioned, attached garage
Wall Library List
Name
Effective R-value
G1 R-13 BATT, R-3.0
15.12
IG1 R-13 Gar Walls
11.141
2
Building Summary
C-M
Energy Solutions
Property Organization Inspection Status
1509 JENSEN DR TSI Energy Solutions Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON [B]
Community: CLAY CORNER 50 Builder
LENNAR HOMES
CC050 [AS DESIGNED]
CLAY CORNER 50
Glazin
Name Library Type Wall ASSlgnment
FDIlndatTOn wall Overhang Delon
Assignment
Overhang Ft To
Top
Overhang Ft TO
Bottom
Orientation
surface Area
BACK 11-.33, SHGG28
CONDIAMB 2X4
0
0
❑
North
90.0 f,
BSMT 11-.33, SHGG28
CONDIAMB 2X4
0
0
❑
East
16.0 fF
FRONT 11-.33, SHGG28
CONDIAMB 2X4
0
0
❑
South
1200.ft2
LEFT SIDE 11-.33, SHGG28
CONDIAMB 2X4
0
0
❑
West
93.0 fF
LEFT SIDE GD U-.33, SHGG28
CONDIAMB 2X4
0
0
0
West
20.0 ff
RIGHT SIDE U-.33, SHGG28
CONDIAMB 2X4
0
0
0
East
73.0 fF
Glazing Library List
Name
Shgc
U -factor
U-.33, SHGC-28
028
0.330
Skylight
None Present
Skylight Library List
None Present
Opaque Door
Name Library Type Wall Assignment
Foundation Wall
Emlttance
Solar
Surface Color
surface Area
Location
Assignment
Absorptance
FRONT Fiberglass Door
CONDIAMB 2X4
0.9
0.75
Medium
24.0 f'
Exposed Exterior
GARAGE Fiberglass Door
CONDIGAR
0.9
0.75
Medium
18.0 fts
Exposed Exterior
Building Summary
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [B]
Community: CLAY CORNER 50
CC050 [AS DESIGNED]
CLAY CORNER 50
Opaque Door Library List
Name
Fiberglass Door
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
V11.1 Tiles
SECOND R-38 Blown, GR1 2,139 No Medium 2,139.0 fls Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R-value
'•0 ? :a l No 38268
Whole House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation M
None Present
1
Lighting
% Interior Fluorescent % Interior LED Lighting % Exter
Lighting
❑ 100
Shelter Class
4
or Fluorescent % Exterior LED Lighting % Garage Fluorescent
Lighting Lighting
0 100 ❑ 100
4
Building Summary
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [B]
Community: CLAY CORNER 50
CC050 [AS DESIGNED]
CLAY CORNER 50
Onsite Generation
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Gnsite Generation Library List I
None
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library Type
Heating Percent Load
Cooling Percent Load
Hot Water Percent Load
Location
Air conditioner
4AC`42P
0%
100%
❑%
Conditioned Space
Fuel -fired air 915SA4206OS17 100% 0% ❑% Conditioned Space
distribution
Water Heating RE350` 0% 0% 100% Conditioned Space
Equipment Type: 4AC*42P
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 40
A
Building Summary
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [B]
Community: CLAY CORNER 50
CC050 [AS DESIGNED]
CLAY CORNER 50
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Equipment Type: 915SA4206OS17
Fuel Type
Distribution Type
Motor Type
Heating Efficiency
Heating Capacity [kBtulh]
Use default EAE
EAE [kWh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Natural Gas
Forced Air
PSG (Single Speed)
95.5 AFUE
58
No
636
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
❑.99
C-M,
Energy Solutions
Building Summary
Property
Energy Solutions
Organization Inspection Status C-M
1509 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [B]
Community: CLAY CORNER 50
Builder
LENNAR HOMES
CC050 [AS DESIGNED]
CLAY CORNER 50
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
3074
# Return Grilles
3
Supply Duct R Value
10
Return Duct R Value
10
Supply Duct Area r]
829.98
Return Duct Area [ft2]
461.1
Leakage to Outdoors
150 CFM25 (4.881 100 s.f.)
Total Leakage
240 CFM25
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan W
Has Ceiling Fan No
Cfm Per Watt 101
7
Building Summary
Property
1509 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [B]
Community: CLAY CORNER 50
CC050 [AS DESIGNED]
CLAY CORNER 50
Water Distribution MM
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
r5N5
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
65
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
C-M,
Energy Solutions
,�