HomeMy WebLinkAboutEnergy Code - JG093 (AS DESIGNED)IECC 2009 Performance Compliance Property 1238 SKYTAG DR CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 93 JG093 (AS DESIGNED) JACKSONS GRANT 93 Organization TSI Energy Solutions Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. Design Heating Coaling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $2,192 $360 $214 $2,766 $1,156 $0 $3,922 Requirements 405.3 Performance -based compliance passes by D.4% ® R402.4.1.2 Air Leakage Testing 0 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration LI-Factor ® 4032.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C",Erergy Solutions As Designed $2,261 $279 $214 $2,754 $1,121 $0 $3,874 Air sealing is 5.00 AC at 50 Pa. It must not exceed 7.00 AC at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 0.4%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zane 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 9f13119 at 9:57 AM Ekotrope RATER - Version 3.1.1.2251 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 1238 SKYTAG DR CARMEL, IN 46032 Builder: EXECUTIVE HOMES CONSTRUCTION, INC. Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.3, SHGC: 0.28 Building Features Duct Supply R-20.0, Return R-20.0 Duct Leakage to Outside 250 CFM25 (4.23 / 100 s.f.) Total Duct Leakage 472 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Natural Gas • 0.7 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 9/13/19 at 9:57 AM Ekotrope RATER - Version 3.1.1.2251 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 1238 SKYTAG DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSDNS GRANT 93 General Building Information Conditioned Area (sq ft) 5,915 Conditioned Volume (cubic ft) 56,395 Insulated Shell Area (sq ft) 11,475 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT(1,822 s.f., 213 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor ] Name: GARAGE (450 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall 1� Name: CGNDIAMB (Exterior Perimeter [ft]: 142, Height Above Grade [ft]: 2.5, Depth Below Grade [ft]: 6.5) 1--I R:9.696 Fully insulated (top to bottom) ] Name: COND/AMB UNFIN (Exterior Perimeter [ft]: 33, Height Above Grade [ft]: 2.5, Depth Below Grade [ft]: 6.5) R: 0.00 Fully insulated (top to bottom) ] Name: CON DIGARAGE UN FIN (Exterior Perimeter [ft]: 38, Height Above Grade [ft]: 2.5, Depth Below Grade [ft]: 6.5) R: 0.00 Fully insulated (top to bottom) Above Grade Wall Energy Code Inspection Checklist Property Organization 1238 SKYTAG DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSDNS GRANT 93 Name: CONDIAMB (3,270 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CON DIGAR (380 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIATTIC (831 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist 1� Name: CONDIAM6 (299 s.f.) 1--1 R: 15.414 Roof Name: CON DIGARAGE (38 s.f.) R: 15.414 Name: CONDIATTIC (119 s.f.) R: 15.414 Name: MAIN (1,989 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Name: BONUS ROOM (360 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I ❑paque Door El Name: FRONT (48 s.f.) U: 0.476 Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist Property 1238 SKYTAG DR CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 93 JG093 (AS DESIGNED) JACKSONS GRANT 93 Name: GARAGE (20 s.f.) U: 0.182 Glazing Organization TSI Energy Solutions Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. Inspection Status Results are projected El Name: FRONT (176 s.f.), U: 0.300, SHGC: 0.28, Orientation: SOUTH [] Name: BACK (214 s.f.), U: 0.300, SHGC: 0.28, Orientation: NORTH El Name: LEFT (76 s.f.), U: 0.300, SHGC: 0.28, Orientation: WEST El Name: RIGHT (96 s.f.), U: 0.300, SHGC: 0.28, Orientation: EAST Name: SLIDER (48 s.f.), U: 0.300, SHGC: 0.28, Orientation: EAST El Name: BACK BSMT (30 s.f.), U: 0.300, SHGC: 0.28, Orientation: NORTH Name: LEFT BSMT (16 s.f.), U: 0.300, SHGC: 0.28, Orientation: WEST Skylight None Present Mechanical Ventilation Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 24 hrslday, 6 Watts. Mechanical Equipment FURNACE 1 • Natural Gas • 100% Heating Load @ 92.1 AFUE El AC 1 • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Natural Gas • 100% Hot Water Load @ 0.7 Energy Factor CTMEriergy Solutions 3 Energy Code Inspection Checklist Property Organization 1238 SKYTAG DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSDNS GRANT 93 Air Leakage Control inspection Status Results are projected Test Status: Blower -door tested House is air -sealed as to achieve 4,700 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to ❑utside specified as: 250 CFM25 (4.23 / 100 s.f.) Total Leakage specified as: 472 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status *Sl Energy Solutions 1238 SKY -FAG DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 93 Number Of Bedrooms 5 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5,915 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 56,395 Total Units in Building 1 Residence Type Single family detached Floor Number Model CUSTOM Community JACKSONS GRANT 93 Climate Zone 5A rFoundation Wall Name Library type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Finished, G1 2.5 6.5 142 Exposed Exterior Conditioned Space CONDIAMB UNFIN Uninsulated 2.5 6.5 33 Exposed Exterior Conditioned Space CONDIGARAGE Uninsulated 2.5 6.5 38 Exposed Exterior Conditioned Space UNFIN Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Tap To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulatian value Top Bottom R-11 Finished, G1 NIA NIA Yes NIA NIA 9.696 Uninsulated NIA NIA Yes NIA NIA 0.00 lab Name Library type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 213 Below Grade ❑ ❑ 1,822.0ft' Exposed Exterior Conditioned Space 1 Building Summary Property Organization Inspection Status 1238 SKY -FAG DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 93 Slab Library List Name Wall Construction Slab Completel�r Underslab Perimeter Perimeter Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Woad Frame 1 Other No ❑ 0 ❑ C"IEnergy Solutions No 0.00 Framed Floor Name Library Type Carpet R Floor Grade Surface Area Location I GARAGE R-38. GR1 1 Above Grade 450.0 ft' Unconditioned. attached garage Framed Floor Library List Name Effective R-value G 33.825 Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-19. OSB 299.0 ft' Exposed Exterior CONDIATTIC G1 R-19. OSB 119.0 ft1 Attic CONDIGARAGE G1 R-19. OSB 38.0 ft1 Unconditioned, attached garage Rim Joist Library List Name Effective Insulation R-value G1 R-19. OSB 15.414 Building Summary Property Organization 1238 SKY -FAG DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 93 Inspection Status Results are projected C"IEnergy Solutions 1-111C LIYIGIr 1311ju JY1-w YY1Vl LYL L-11 CONDIAMB G1 R-15 BATT, OSB Medium 3,270.0 ft' Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 831.0 ft, Attic CONDIGAR G1 R-15 Gar Walls Medium 380.0 ft2 Unconditioned, attached garage Wall Library List Name Effective R-value G1 R-15 BATT. OSB 13.423 G1 R-15 Gar Walls 11.972 Glazing Name Library type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhan-0 Ft To Orientation Surface Area Assignment Tap Ejottom BACK U-.30. SHGC-.28 CONDIAMB 0 0 0 North 214.0 ft' BACK BSMT U-.30, SHGC-.28 CONDIAMB 0 0 0 North 30.0 ft' FRONT U-.30, SHGC-28 CONDIAMB 0 0 0 South 176.0 ft2 LEFT U-.30. SHGC-28 CONDIAMB 0 0 0 West 76.0 ft2 LEFT BSMT U-.30, SHGC-28 CONDIAMB 0 0 0 West 16.0 ft2 RIGHT U-.30. SHGC-28 CONDIAMB 0 0 0 East 96.0 ft2 SLIDER U-.30. SHGC-.28 CONDIAMB 0 0 0 East 48.0 ft2 Glazing Library List Name Shg c U-facto r U-.30, SHGC-.28 028 0.300 3 Building Summary Property 1238 SKY -FAG DR CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 93 JG093(AS DESIGNED) JAGKSONS GRANT 93 Skylight fW I Skylight Library List Opaque Door Organization TSI Energy Solutions Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. i None Present Inspection Status Results are projected C"IEnergy Solutions Name Library Type Wall Assignment Foundatian Wall Emittance Solar Surface Color Surface Area Location Assignment Absorptance FRONT Wood Door CONDIAMB 0.9 0.75 Medium 48.0 fIl Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 20.0 fI2 Exposed Exterior Opaque Door Library List Name Effective U-factor Steel Door 0.182 Wood Door 0.476 Roof Insulation Name BONUS ROOM R-38 Vaulted, GR1 MAIN R-38 Blown, GR1 360 No Medium 360.0 fl' Attic 1,989 No Medium 1,989.0 rtz Attic 4 Building Summary Property 1238 SKY -FAG DR CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 93 JG093(AS DESIGNED) JAGKSONS GRANT 93 Roof Insulation Library List Name Has R-38 Blown, GR1 R-38 Vaulted, GR1 Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. No 38.268 No 32.263 Whole House Infiltration Infiltration Measurement type Shelter Class 5ACH at 50 Pa Blower -door tested MW Mechanical Ventilation Ventilation Type Ventilation Rate [ft' l Operational hours per day Minute] Exhaust Only 20 24 Lighting % Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent Lighting Lighting 0 80 a Onsite Generation one Onsite Generation Library List None Present 4 C"IEnergy Solutions Fan Watts Runs once every three Energy Recovery Percent hours 6 Yes ing % Garage Fluorescent % Garage LED Lighting Lighting 80 0 8C 5 Building Summary Property 1238 SKY -FAG DR CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 93 JG093(AS DESIGNED) JAGKSONS GRANT 93 Solar Generation Organization TSI Energy Solutions Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. Solar Generation Library List None Conditioning Equipment Name Library Type AC " CA13MA042-A FURNACE 1 912SA481o0S17 Water Heating GPVX-75L-210 Equipment Type: 912SA4810OS17 9 *Sl Energy Solutions Inspection Status Results are projected ng Yercen . LoaG MOT water YercenT Loao LOCaTIOn 0% 100% 0% Conditioned Space 100% 0% 0% 0% Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 93 Use default EAE No EAE [kWh] 756 Equipment Type: CA13NA042-A Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 0% Conditioned Space 100% Conditioned Space Building Summary Property Organization 1238 SKY -FAG DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 93 quipment Type: GPVX-75L-210 Fuel Type Natural Gas Distribution Type Hydronic Delivery Hot Water Efficiency 0.7 Energy Factor Tank Capacity (gal.) 75 Hot Water Capacity [kBtulhl 40 Recovery Efficiency 0.79 r Distribution System Distribution Type Forced Air Heating Equipment FURNACE 1 Cooling Equipment AC 1 Sq. Feet Served 5915 # Return Grilles 4 Supply Duct R Value 20 Return Dud R Value 20 Supply Duct Area [ftq 1597.05 Return Dud Area [ftJ 1183 Leakage to Outdoors 250 CFM25 (4.231 100 s.f.) Total Leakage 472 CFM25 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented, under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ rCeiling Fan Has Ceiling Fan No Cfm Per Watt 100 Inspection Status Results are projected C"IEnergy Solutions Building Summary Property Organization 1238 SKY -FAG DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 93 Builder EXECUTIVE HOMES JG093 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 93 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 75 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 20 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls INA Label Energy Rating 704 kWh1Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 Imet ❑.331 ppliances and Controls rogrammable thermostat? Yes ishwasher Size Standard ishwasher Efficiency ID 270 kWhangefOven Fuel Electric onvection Oven? N❑ duction Range? N❑ efrigerator Consumption 709 kVVhfYear Inspection Status Results are projected C"IEnergy Solutions