HomeMy WebLinkAboutSewer Permit- JG93-
_
34V:
10701 N. College Avenue Suite A
Indianapolis, Indiana 46280
phone 317-844-9200
fax 317-844-9203 www.trico.eco
Residential
SANITARY SEWER PERMIT
999913465
Permit Type
Final
Subdivision
Jacksons Grant
Project WO
ENG17652013
Section Number
1A
Project Name
Jacksons Grant 1A
Lot Number
93
Project Developer
Billy Creek Assocs.,LLC
Address Number
1238
Lift Station
26 Jacksons Grant
Address 2
Treatment Plant
MIX
Street
Skytag Drive
Parcel Acreage
0.35
City
Carmel
EDU in Gallons
310
Zip Code
46032
County
Hamilton
Local Sewer Charge - District Contribution
0.00
Builder
Executive Homes
Plan Review and Inspection
0.00
Application Fee
150.00
Phone Number
317-843-2700
EDU Fee
1908.00
Owner
Interceptor Fee
0.00
Phone Number
Other Fees
0.00
Fees Due
2058.00
Occupant
Invoice Number
Phone Number
PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by TriCc, are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has:
Main ID:
JG809-JG808
Grease Trap
Slab Foundation
Grease Interceptor
Crawl Space Manhole IDs USMH
JG-809 JG-808 DSMH
Grit Interceptor
Basement YES Lid Elevation
r
869.09d'
870.29 v/
Grinder Station
First Floor Elevation
872.50'
872.50 ://
Water Service
City of Carmel Basement Elevation
/
862.50 J
862.50 /
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor
3.41
2.21 Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by:
Ejector Pump Only
SnCo currently requires that an I&I inspection is performed and a Certificate of Compliance is issued prior to occupancy /
sale of a property. Please review attached 1/1 Permit.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
5 The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
The terms of the conditional permit, if any, are listed below.
Plans have been submitted.
All fees have been paid.
No certificate of insurance required.
No additional permits required.
No manhole core permit required.
The facility is not classified as a FOG facility.
(Notes)
oy siynmy ueiow, i anesi mac i am ramniar m me ui nci s speancanons and agree to accept responslbllity for all work done under this permit.
Builder / Owner Signature Phone Number 3 ( 7 %
C �Gc R
Printed Name
Approved By , fi T r i C O
Ryan Ham n, stnct Engineer
Permit is valid fc ON YEAR from the date issued. Permit valid only with TdC ~ I in r d i k.
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. Only one building may connect to the sewer main per lateral unless otherwise approved by TriCo.
2. Foundation drains, sump drains, downspouts and other storm water drains shall never be connected to the sanitary sewer.
Site dewatering systems shall never be discharged to the sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be reused if it is located under a building addition, patio,
porch or paved driveway, and the line passes an air test that is observed by TdCo. Contact TriCo for more information about
air testing requirements. The property owner is responsible for testing costs.
4. TriCo shall inspect all new laterals or lateral repairs in their entirety. Final connection to the sanitary sewer must be observed
by Trico. The property owner or contractor must notify TriCo prior to backfilling. Inspections must be scheduled at least 24
hours in advance. If an inspection fails and subsequent inspections are required, or if the contractor is not on site for the
scheduled inspection, a $100 fee will be assessed and must be paid prior to scheduling the reinspection.
5. Septic system contents or effluent shall never be discharged to the sanitary sewer. Be advised that your county health
department regulates septic systems. Upon connection to sanitary sewer, a septic tank must typically be abandoned,
pumped clean, and filled completely with earthen material. Contact your county health department for more information on
septic system and abandonment requirements, and to notify the department of any abandonment.
6. The following materials are acceptable for use in gravity sewer lateral installation or repair:
PVC pipe: SDR 35 or SDR 26, ASTM D3034, 6" diameter
PVC pipe, pressure rated: SDR 21, ASTM D2241, 6" diameter
PVC restrained joint pipe for directional drilling: Certaflo Greenline SDR 21, ASTM D2241, 6" diameter
All gasketed joints shall meet ASTM D3212
All fittings shall be SDR26 or better
Ductile iron mechanical joint fittings with proper hardware
SDR 26 gasketed repair sleeves or Indiana Seal shear guard
Femco and similar flexible couplings are only acceptable in certain circumstances and shall not be used without
prior approval from THCo
Cleanouts: 6" threaded PVC caps
Bedding: Use #8 crushed stone or fractured face aggregate
The following materials are acceptable for use in low-pressure sewer lateral installation or repair:
HDPE pipe for directional drilling: DR 11 IPS, 1.25" diameter, PE4710
Connections shall be made via electrofusion or using polypropylene or stainless steel compression fittings
Electrofusion high volume tapping tee, rated 200 psi, PE4710
1.25" IPS full port 1/4 turn fusible PE ball valve, rated 200 psi
Threaded swing check valve, 316 stainless steel, rated 200 psi
Contact TriCo for acceptable pump station materials, equipment, pumps and other requirements
7. For gravity and low-pressure systems, the line leaving the building shall not exceed 3' in length before a cleanout must be
added and the line is transitioned to 6" diameter SDR 35 PVC pipe. Glued joints are not allowed after 3'. No additional glued
fittings are allowed between the building and the transition/cleanout. For all gravity lines, ceanouts shall not be spaced more
than 100' apart between the building and the sewer main. See TriCo's standard drawings for more information on cleanout
installation.
8. Bedding material shall be placed from at least 6 inches below to 12 inches above the pipe surface. The trench shall be a
minimum of 18" wide with at least 6" of clearance on both sides of the pipe. Material shall be placed over the pipe and tracer
wire after inspection. Soft, unstable or unsuitable material found below and near the lateral, including any fill or foundation
backfill material, must be removed and replaced with #8 stone. The contractor is solely responsible for establishing stable
pipe bedding conditions.
9. #10-AWG solid copper tracer wire shall be laid on top of and run the entire length of the lateral. All splicing of tracer wire
shall use 3M splice kit model DBR/Y-6, King Innovation Dryconn Direct Bury Lug Aqua catalog #90220, or TdCo approved
10. Laterals shall be installed at least 20' from water wells unless PVC pressure grade pipe is used. Any proposed installation
requiring pressure pipe shall be reviewed by TriCo prior to installation. Where a transition is made between SDR 35 pipe and
pressure grade SDR 21 pipe, a ductile iron gasketed mechanical couplings must be used.
11. Laterals less than S deep shall be at least 24" from the property line. Laterals more than 5' deep shall be at least 36" from
the property line. Where the lateral runs in close proximity to the property line the property comers must be accurately
staked by a professional land surveyor prior to inspection.
12. Laterals running parallel to a building or structure shall be at least 36" from the face of a crawl space or slab on grade
foundation and 60" from the face of a basement foundation wall. Spacing requirements also apply with respect to the
ancillary structure's foundation depth. Ancillary structures (e.g. window wells) and other utilities shall not be placed over or
near the lateral. TriCo may adjust requirements where future access to the lateral may be obstructed by other utilities. The
contractor should call to discuss further if he/she believes this could be an issue.
13. All infrastructure connected to TriCo's sewer system may be tested, inspected, or televised at TdCo's discretion, and must
remain accessible and properly maintained.
14. Call 811 or 1-800-382-5544 before you dig. For more information go to www.indiana811.org.
TriCo Regional Sewer Utility
10701 North College Avenue Suite A
Indianapolis, Indiana 46280
Phone(317}844-9200 Fax(317)-844-9203
Revised 03/19/2019
Executive Homes Construction, Inc.
1010 3rd Ave SW, Suite 202
Carmel, IN 46032
(317) 843-2740
PAY TO
E
ORDER OF
TriCo Regional Sewer Utility
ORDER OF
Two Thousand Fifty -Eight and
MEMO
TriCo Regional Sewer
P.O. Box 40638
Indianapolis, IN 4624(
Sewer permit JG93
71-287/719
u•00418911,-1:0?19028781: 110102435553112
4189
10/28/2019
$"2,058.00
TriCo Regional Sewer Utility
10701 N. College Avenue Suite A
Indianapolis, Indiana 46280
phone 317-844-9200 fax 317-844-9203 www.trico.eco
Residential
1 & 1 Permit
Ordinance 12-08-08
Lateral Location
Owner y Occupant Information
Address Number
1238
Owner
Address 2
First Name
Street
Skytag Drive
Last Name
city
Carmel
Phone Number
State
IN
Mobile Number
Zip Code
46032
Fax Number
Subdivision
Jacksons Grant
Email Address
Section Number
to
Lot Number
93
Permit Information
Owner Address if Different
Address Number
Address 2
Street
City
State
Zip Code
Builder Information
Builder
Executive Homes
Phone Number
317-843-2700
Facility Features and Addition Information
Slab Foundation
Square Footage
Crawl Space
Water Type
City of Carmel
Basement
YES
Basement Status
Ejector Pump Only
Cleanout
YES
Main ID
JG809-JG808
Ejector Pump
YES
Lift Station
26 Jacksons Grant
Sump Pump
YES
Grinder Station
Program Specifications
■ This program requires prior to the sale/occupance of a property that the property owner/builder notify TriCo and
schedule an inspection. The inspection will verify that:
■ Downspouts are not connected to the sanitary sewer
• The sump pump is not connected to the sanitary sewer
• Cleanout caps are in place and watertight
• No yard drains are connected to the sanitary sewer
• There are no sinkholes or other indications that the sewer lateral is leaking
• 5 Ton or greater HVAC units do not dishcarge condenstion to the sanitary sewer.
• If deficiencies are found, the property owner will be notified and must make corrections immediately. The property
owner will need to schedule a follow up inspection. If a certificate of compliance is not issued within 30 days of the
change in ownership, a sewer surcharge of $20 per month will be assessed and added to the sewer bill.
Owner/Occupant Signature: Date: dDate:
Approved By: Date:
:1Grou
Land Surveyors
494 Gradle Drive Phone: 317.844.3333
Cannel, IN 46032 Fax: 317.844.3383
www.SEAGroupLLC.com
THIS PLOT PLAN WAS
PREPARED BASED ON
INFORMATION TAKEN FROM
RECORD PLATS, SUBDIVISION
PLANS, RECORD DRAWINGS
AND PLANS PROVIDED BY
CLIENT. IT IS THE
RESPONSIBILITY OF THE
CONTRACTOR TO VERIFY SITE
CONDITIONS PRIOR TO
CONSTRUCTION AND NOTIFY
THE S E A GROUP OF ANY
DISCREPANCIES.
MINIMUM SETBACKS
MIN, I YARD - I
NF, .: YARD F Feet
Feet
FOO-701 PROPOSED GRADE
GROUND WATER FLOW
SAN SANITARY SEWER LINE
STM STORM SEWER LINE
WTR WATER UNE
- - - - - - - - - - EASEMENT LINE
BUILDING SETBACK UNE
EXECUTIVE HOMES
NOTE: NOTE: NOTE:
BUILDER TO ENSURE POSITIVE BUILDER TO MAINTAIN A 10' SUMP TO S PLACED BY
FLOW AWAY FROM SEPARATION BETWEEN WATER BUILDER AS NEEDED.
STRUCTURE. AND SANITARY LATERALS.
SAN. STR. (808)
TC-870.0
PER PLAN
II
i 15.4'
I
j
869.5
i
Vj
I
£9'£
fi1.75'
W
I
PROPOSED
F
i
g RE90ENCEY
-.9C1 FFE_872.5
STR.
LOCATION OF UTILITY
LATERALS ON PLOT PLAN
ARE GENERAL LOCATIONS
PER PLAN AND SHOULD BE
VERIFIED IN THE FIELD.
0
N
BSMT
FFE.862.Sf 12.2910
X I
a
86s.so OARAGEL—1 S ass.
a 38
s
a FFEB69.8k '
55.87'
t \ 869.5
CONC
DRIYE MANH
H
z ES MUST X
REMAIN ACCESSIBLE 86a.3o
135.0'
AT GRADE
ALL TIMES
DRIVEWAY APRON - 73 t SF
CONC. DRIVEWAY - 1.386 f SF
PUBLIC WALK - 542 f SF
PRIVATE WALK - 279 t SF
HYDRO SEEDING - 3.758 t SF
SOD - 713 t SO. YRDS
EVEN WITH REAR OF HSE
Property Description:
Lot Number 93 in Jackson's Grant on Williams
Creek, Section 1A, an Addition in Hamilton
County, Indiana, as per plat thereof recorded
Instrument Number 2015064863 found in the
Office of the Recorder of Hamilton County,
Indiana.
No._'
LS20200083
STATE OF
PLOT PLAN I rrExecutive Homes
Scale: 1"=30' I Drawn by. DJR I Residence
Date: Sept. 6, 2019 1238 Skytog Drive