HomeMy WebLinkAboutA101 CONSTRUCTION PLAN - FIRST FLOORRELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carried (�
�VT�'la>nckw�L
DATE: \ 11/14/19
1 CONSTRUCTION PLAN - FIRST FLOOR
SCALE: 1/4" = T-0"
2
CONSTRUCTION PLAN LEGEND
NOT IN CONTRACT, IF APPLICABLE
EXISTING WALL OR ITEM TO REMAIN
NEW CONSTRUCTION ITEM
GENERAL CONSTRUCTION NOTES
A.
REFER TO SHEETA000 FOR DOOR AND WALL TYPES.
B.
DOORS NOT INDICATED BY A DOOR NUMBER DESIGNATION ARE EXISTING IF APPLICABLE.
C.
PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES WHEN APPLICABLE. PATCH
AND REPAIR AS REQUIRED.
D.
PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT.
REFER TO ELECTRICAL LOCATION PLANS FOR MORE INFORMATION.
E,
ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES,
ORDINANCES, RULES, REGULATIONS AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE
INDIANA BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH
DISABILITIES ACT (ADA), INTERNATIONAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL
APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENTADOPTED EDITIONS.
R
THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR
TOTHESTARTOFWORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER
IMMEDIATELY.
G.
THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALLSTATE AND LOCAL PERMITS REQUIRED FOR
COMPLETION OF THIS PROJECT.
H.
ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT,
FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE
REQUIREMENTS OF THE OWNERS F.F.E.
I.
ALL DIMENSIONS ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER. DO NOT SCALE DIMENSIONS
ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF NEW STUD, MASONRY/CONCRETE
WALLS, CENTERLINE OF COLUMNSIWINDOWS, OR FINISH FACE OF EXISTING WALL UNLESS NOTED
OTHERWISE.
J.
CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL HAS BEEN REVIEWED, APPROVED, AND
THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED.
K.
DURING THE ENTIRE PERIOD OF CONSTRUCTION, ALL EXISTING EXITS, EXIT LIGHTING, FIRE
PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
L.
FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT PERPENDICULAR
PARTITIONS, UNLESS OTHERWISE NOTED.
M.
ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS,
PREMIUM GRADE.
N.
ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE CONTRACTOR,
DESIGNER AND THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION.
O.
CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THE
WORK IN THESE DOCUMENTS, UNLESS CLEARLY NOTED "NOT IN CONTRACT" (N.I.C.). EXISTING
WORK ADJACENT TO OR IN THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE
MEANS NECESSARY TO PREVENT OR MINIMIZE DAMAGE. WHERE EXISTING WORK IS TO BE
REMOVED OR ALTERED, RESTORE ADJACENT FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH
ALL FRAMES, BASE, AND TRIM WHERE CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR
ANY DAMAGE TO EXISTING WORK AND RESTORE TO ORIGINAL CONDITION.
P.
CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES FREE
OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR AND
SHALL BE STORED IN A LOCATION APPROVED BY THE LANDLORD.
Q.
ALL PLUMBING ITEMS ARDOR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFIED WITH
INTERIOR ELEVATIONS PRIOR TO ROUGH -IN. ANY DISCREPANCIES SHALL BE COORDINATED WITH
THE DESIGNER.
R.
COORDINATED WITH OWNER AND FACILITY STAFF PROJECT PHASING TO MINIMIZE DISRUPTION OF
EXISTING FACILITY SERVICES. PHASING TO INCLUDE ASSURANCE FOR CLEAN AIRFLOW, WRITTEN
NOTIFICATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITY. CONTRACTOR, OWNER, AND
FACILITY STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMAN
HEALTH AND SAFETY. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREAS
DURING ALL PHASES OF CONSTRUCTION USING AIRTIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL
BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE.
S.
SUBMIT THE REQUIRED NUMBER OF SUBMITTALS FOR DESIGNER REVIEW AND APPROVAL PLUS ONE
EXTRA COPY FOR DESIGNERS RECORDS.
T.
ALL WALLS TO BE PARTITION TYPE W4.11 UNLESS NOTED OTHERWISE.
®
CONSTRUCTION PLAN KEYNOTES
100
MODIFY EXISTING DOOR, FRAME AND HARDWARE AS REQUIRED TO RECEIVE NEW KEYPAD. COORDINATE ALL
WORK REQUIRED WITH OWNER AND OWNER'S SECURITY VENDOR. ALL SECURITY ACCESS CONTROL
DEVICES SHALL BE "FAIL SAFE."
101
EXISTING PARTITION FRAMING TO REMAIN. FURNISH AND INSTALL GWB AND MODIFY AS REQUIRED TO MATCH
PARTITION TYPE W4.11, TYPICAL.
102
FURNISH AND INSTALL 3/4"FIRE-TREATED PLYWOOD BLOCKING FOR OWNER SUPPLIED TV. COORDINATE
EXACT SIZE AND LOCATION WITH OWNER. 2
104
HOLD 4-112" TO NEW PARTITION FROM EDGE OF EXTERIOR DOOR FRAME.
105
EXISTING EXTERIOR DOOR TO BE LOCKED SHUT. COORDINATE EXTENT OF WORK WITH OWNER.
107
LAMINATE EXISTING WOOD COLUMN WITH 5/8" GYPSUM WALLBOARD.
108
NEW WOOD COLUMN, PLACEMENT TOALIGN WITH FACE OF STAIR OPENING. LAMINATE WITH 5/8"GYPSUM
BOARD. REFER TO STRUCTURAL ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.
109
PAINT ELECTRICAL PANEL TO MATCH ADJACENT WALL, SEMI -GLOSS FINISH.
110
FURNISH AND INSTALL 3l4"FIRE TREATED BLOCKING FOR OWNER PROVIDED LOGO. COORDINATE EXACT SIZE
AND LOCATION WITH OWNER.
111
EXISTING WALL TO RECEIVE PLYWOOD SHEATHING BOTH SIDES. REFER TO STRUCTURAL FOR MORE
INFORMAITON.
112
FURNISH AND INSTALL FULLY RECESSED MECHO MOTORIZED SHADE SYSTEM WITH ELECTROPOCKET ALONG
GLASS STOREFRONT. COORDINATE EXACT SHADE FABRIC WITH OWNER'S DESIGN CONSULTANT. REFER TO
REFLECTED CEILING PLAN AND ENGINEERING DRAWINGS FOR ADDITIONAL IN FORMATION.
MITSCH
D E S I G N
200 S. Rangeline Rd. I Suite 226
Carmel, Indiana 46032
317.573.2222
www.milschdesgn.com
V1
W LLJ
W Cq
Cx 0 W
W Lr) U)
Uwe Z
iiiiiiiim O
E 0 LL Ex Q
mil O < o U
LL J Z
^O �LLJ ZJ(n
W
r
QaLLJ
do Q O
? V�UU
JJ\\PIIII II IIIII����
h s ;
° m=
AR00034184 J
L STATE OF L
ottFa
0
a
O
O
W
U
W
co
^
O
N
co
O
w
co
m
r¢
m
i
0¢¢
O
U
m
O
N
�
m
K
W
H
N
N
W
O
Z m
O
O
O
N
VITSCH DESIGN, ALL RIGHTS RESERVED, EME17 FOR USES
EXPRESSLY PERIAJ IN WRJTNJ
CONSTRUCTION PLAN -
FIRST FLOOR
A101