Loading...
HomeMy WebLinkAboutA201 REFLECTED CEILING PLAN (LOCATION ONLY)RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camlel (� �VT�'laMckwA�L DATE: \ 11/14/19 1 REFLECTED CEILING PLAN - FIRST FLOOR SCALE: 1/4' = T-0" zic REFLECTED CEILING PLAN LEGEND NOT IN CONTRACT, IF APPLICABLE tiDENOTES NEW 2'x2'ACOUSTICAL CEILING GRIDITILE DENOTES NEW GYPSUM BOARD CEILING ® DENOTES NEW 4' SQUARE LED FIXTURE; REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR SPECIFICATIONS DENOTES NEW LINEAR FIXTURE; REFER TO ELECTRICAL ENGINEERING Li DRAWINGS FOR SPECIFICATIONS 0L2 DENOTES NEW LINEAR FIXTURE; REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR SPECIFICATIONS DENOTES NEW PENDANT; REFER TO ENGINEERING DRAWINGS FOR L3 SPECIFICATIONS ® L4 DENOTES NEW PENDANT; REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS BI DENOTES NEW EMERGENCY EXIT SIGN; REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS M DENOTES LIGHT SWITCH �a DENOTES THREE-WAY LIGHT SWITCH $D DENOTES LIGHT SWITCH WITH DIMMER u DENOTES MOTORIZED SHADE SWITCH NOTE: ALL LIGHTING AND MECHANICAL ITEMS FOR LOCATION PURPOSES ONLY. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. GENERAL REFLECTED CEILING NOTES A. PROVIDE FIRE DAMPERS AT FIRE -RATED PARTITIONS AS REQUIRED PER APPLICABLE BUILDING CODES. B. CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND ALLAPPLICABLE BUILDING CODES. C. PAINT NEW GYPSUM BOARD BULKHEADS CEILING WHITE, UNLESS OTHERWISE NOTED. D. REMOVE EXISTING SWITCHES THAT ARE NOT RE -USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH. E. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK. R CEILING HEIGHT THROUGHOUT THE FIRST FLOOR SPACES IS 9'-7-A.F.F., UNLESS NOT OTHERWISE. L2 G. CEILING HEIGHT THROUGHOUT THE SECOND FLOOR FLOOR SPACES IS 10'-6' A.F.F., UNLESS NOTED OTHERWISE. H. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6' FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. I. EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN TILE, UNLESS NOTED OTHERWISE. J. COLOR OF LIGHT SWITCH DEVICES SHALL BE WHITE WITH STAINLESS STEEL COVERPILATE UNLESS NOTED OTHERWISE. K. ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE. L. REFER TO ENGINEERING DOCUMENTS FOR INFORMATION, LOCATION AND SPECIFICATIONS ON EXIT SIGNAGE, LIFE SAFETY SYSTEMS, 24 EMERGENCY LIGHTING, VENTILATIONS, HVAC SYSTEMS, CIRCUITING OF LIGHTS AND THERMOSTAT LOCATION ETC. M. THERMOSTATS SHALL BE LOCATED ADJACENT TO LIGHT SWITCH AND WITHIN REACH RANGES OUTLINED IN ANSI A117.1-2009 SECTION 308 AND 309. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT. N. SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE IN COLOR. REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION. O. ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. P. IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION. Q. VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR. T] REFLECTED CEILING PLAN KEYNOTES 200 LINE OF STRUCTURAL HEADERS ABOVE FINISHED CEILING. REFER TO DETAIL D251 AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 201 5/8" GYPSUM BOARD WITH 1/2' FRY REGLET LED LIGHTING REVEALS; LIGHTED U CHANNEL SYSTEM; LED-MW U5050. REFER TO DETAIL 41251 F R AND ELECTRICAL ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 2 203 FURNISH AND INSTALL SUSPENDED ACOUSTICAL CEILING GRID AND TILE CLOUD,ACT-1, AT 8'£' A.F.F AS DIMENSIONED WITH AXIOM KNIFE EDGE TRIM IN WHITE. 204 FURNISH AND INSTALL RECESSED MOTORIZED SHADE AT ALL INTERIOR GLASS PARTITIONS. SPECIFICATION: MECHOSHADE ELECTROSHADE WITH FULLY RECESSED ELECTROPOCKET; SHADE FABRIC: TED; REFER TO M01 AND ELECTRICAL ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. MECHOSHADE TO FIT BETWEEN MULLIONS OF CURTAIN WALL. 205 BOTTOM OF SUSPENDED LINEAR FIXTURE TO BE INSTALLED AT 8'-0" A.F.F. 206 BOTTOM OF SUSPENDED LINEAR FIXTURE TO BE INSTALLED AT 7'-6" A.F.F. 207 BOTTOM OF PENDANT FIXTURE TO BE INSTALLED AT 8'-0' A.F.F.; CENTER ABOVE ISLAND; COORDINATE IN FIELD. 208 FIXTURE TO BE LOCATED IN IMPLIED CENTER 0 DOM; COORDINATE EXACT LOCATION INFIELD WITH OWNER'S DESIGN CONSULTANT. 2 210 BOTTOM OF PENDANT FIXTURES AT T-0- A.F.F. CENTER ABOVE RECEPTION DESK; COORDINATE IN FIELD. 212 FURNISH AND INSTALL JUNCTION BOX FOR BACKLIT SIGN. COORDINATE WITH SIGN VENDOR FOR LOCATION AND ELECTRICAL PLANS FOR SWITCHING NEEDS. 914 FURNISH AND INSTALL UNDERCABINET LIGHTING AND WALL SWITCH. COORDINATE EXACT LENGTHS REQUIRED WITH CABINET SUPPLIER. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 915 FURNISH AND INSTALL JUNCTION BOX FOR FUTURE LIGHT FIXTURE. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH OWNER IN FIELD. MITSCH D E S I G N 200 S. Rangeline Rd. I Suite 226 Carmel, Indiana 46032 317.573.2222 www.milschdesgn.com V1 W LLJ W Cq a 0 W W MW UwNt z O Emi p LLLL Ex Q F- O<oU �V LL J Z ^O �LLJ ZJ(n W Graz Q 01) Q O Z V U U TTUpllll II III/bippGii o• pgT R. �olsrE� AR00034184 Jy ;T STATE OF T� Ou 0 E M a o 0 f W U w cu ^ N 0 O of Woo O O m Do ¢ ¢ O U z O N � m iE W F- N N W m Z lq y O C 0 AUTHORSHIP VED osscINrvsu,o GIME MEDIUM OF EXPRESSION E INDIOkNSORPSENTED 6YTHESE DRAWINGS AND DOCUMENTS MEOINDRY ETHEPP Doi DESIGN. RIGHTS RESERVED, EXCEPT FORUSES EXPRESSLY GERMITEn N WRITING REFLECTED CEILING PLAN (LOCATION ONLY) A201