Loading...
HomeMy WebLinkAboutA901 ELECTRICAL - DATA PLAN - FIRST FLOOR (LOCATION ONLY)raw ■ IRBI rRBI RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Carmel (� �VT�'laMckw�L DATE: \ 11/14/19 1 ELECTRICAUDATA PLAN -FIRST FLOOR SCALE: 1/4" = T-0" N ELECTRICAL/DATA PLAN LEGEND NOT IN CONTRACT, IF APPLICABLE STANDARD DUPLEX RECEPTACLE STANDARD QUAD DUPLEX RECEPTACLE V STANDARD RECEPTACLE (VOICE/DATA) STANDARD DUPLEX RECEPTACLE(W/WHIP) a 9 STANDARD RECEPTACLE (VOICE/DATA W/ WHIP) VVVQ STANDARD FLOOR RECEPTACLE (POWER) ® STANDARD FLOOR RECEPTACLE (VOICE/DATA) O`— STANDARD FLOOR RECEPTACLE (POWER W/WHIP) ®^— STANDARD FLOOR RECEPTACLE(VOICE/DATA W/WHIP) GFI DENOTES GROUND FAULT INTERRUPTER 7 DENOTES ITEM FOR TENANT PROVIDED TV +pp DENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE NOTE: ALL ELECTICAUDATA ITEMS FOR LOCATION PURPOSES ONLY. REFER TO ENGINEERING DRAWINGS FOR MORE INFORMATION. GENERAL ELECTRICAL/DATA NOTES A. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. B. ALL MATERIALS AND WORKMANSHIP SHALL MEET ALLAPPLICABLE STATE AND LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS. THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NON COMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE CODES. C. CONTRACTOR TO SUPPLYAND INSTALL ALL ELECTRICAL WIRING, INCLUDING RUNS FROM JUNCTION BOX TO INDIVIDUAL WORKSTATION UNITS. CONTRACTOR TO SUPPLY PLENUM RATED BOXES AND PULLS AS REQUIRED TO ACCOMMODATE TENANT'S TELEPHONE, DATA AND SECURITY DEVICES. D. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION, E. ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS AS INDICATED ON DRAWINGS OR AS REQUIRED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITH DESIGNER PRIOR TO INSTALLATION. F. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR) TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED. G. ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE H. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FOR MILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY. I. ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT xxx" A.F.F. TO CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED. J. SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE BUILDING STANDARDS COLOR. K. ALL DIMENSIONS SHOW ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESS OTHERWISE NOTED. L. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRE TO MINIMIZE SOUND TRANSMISSION. M. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL BE INSTALL WITH A MIN. DISTANCE BETWEEN UNITS. N. CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCAL BUILDING CODES. O. ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT FIXTURES, BALLASTS, EXIT AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY. P. DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUST BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OR WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHED RECEPTACLES TO NEAREST STUD, Q. THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICAL ENGINEER FOR FURTHER TECHNICAL INFORMATION. R. ELECTRICAUDATA OUTLET LOCATION TO BE VERIFIED WITH TENANT PRIOR TO ROUGH -IN. ALL LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT. S. SYSTEMS FURNITURE TO BE DRAWING ON FLOOR PRIOR TO PLACEMENT OF FLOOR CORE AND JUNCTIONBOXES. DESIGNER TO APPROVE LOCATIONS PRIOR TO CORING/PLACEMENT. T. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONNECTING DEALER PROVIDED FURNITURE SYSTEMS POWER IN -FEED TO BUILDING J-BOX WHERE INDICATED ON PLAN. U. PROVIDE FIRE DAMPERS AT FIRE -RATED PARTITIONS AS REQUIRED PER APPLICABLE BUILDING CODES. V. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FORALL DUCTWORK, SUPPLY AND RETURN AIR AND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SYSTEM TO PROVIDE A COMPLETELY BALANCED AND EFFICIENT HEATING AND COOLING SYSTEM. W. HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE. VERIFY AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED. X. MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXITING THERMOSTATS, VAV BOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM. CONTRACTOR TO NOTIFY ENGINEER/DESIGNER IMMEDIATELY UPON DISCOVERY OF DEFECTIVE DEVICE. ® ELECTRICAL/DATA PLAN KEYNOTES 901 COORDINATE WITH CABINET SUPPLIER AND APPLIANCES FOR EXACT LOCATION OF ALL NEW DEVICES AT MILLWORK CABINETS AND ABOVE COUNTERTOP. 902 FLUSH MOUNTED RECESSED FLOOR BOX WITH ELECTRICAL RECEPTACLES, DATA/VOICE OUTLETS AND/OR AA1 CONNECTIONS. DASHED LINE INDICATES CONDUIT PATH IN SLAB. COORDINATE CONDUIT SIZES AND QUANTITIES AND SIZES WITH ENGINEERING DRAWINGS AND OWNER. VERIFY EXACT LOCATION INFIELD WITH TENANT'S FURNITURE VENDOR. REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 903 FURNISH AND INSTALL DEVICES SHOWN FOR OWNER PROVIDED AND INSTALLED TELEVISION. PROVIDE BLOCKING AS REQUIRED. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH TENANT PRIOR TO ROUGH -IN. 905 FURNISH AND INSTALL JUNCTION BOX ABOVE FINISHED CEILING FOR MOTORIZED SHADES. COORDINATE EXACT QUANTIY REQUIRED AND LOCATIONS INFIELD WITH SHADE VENDOR. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 906 FURNISH AND INSTALL MOTORIZED SWITCH FOR MOTORIZED SHADES. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 907 FURNISH AND INSTALL MOTORIZED SWITCH AND JUNCTION BOX (NOT SHOWN) FOR GARBAGE DISPOSAL. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 908 FURNISH AND INSTALL JUNCTION BOX (NOT SHOWN) FOR OWNER PROVIDED DISHWASHER. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 909 POWER AND DATA/VOICE RECEPTACLES LOCATED IN FACE OF MILLWORK; REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 910 COORDINATE POWER REQUIREMENTS FOR OWNER SUPPLIED BACKLIT LOGO WITH BUILDING OWNER. 911 COORDINATE POWER REQUIREMENTS AND EXACT PLACEMENT OF OUTLET WITH OWNER'S APPLIANCE VENDOR. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 913 FURNISH AND INSTALL POWER AS REQUIRED FOR MIRROR. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. MITSCH D E S I G N 200 S. Rangeline Rd. I Suite 226 Carmel, Indiana 46032 317.573.2222 w Umilschdesgn.com V1 1 rx M LL.I Wu~i00 Uiiiiiiis we z _O p LLLL Ex Q F- H�I� O<oU �4 LL J Z LLI ^O �LL ZJ(n W r Q ado Q O ? LLJ V�UU A..... 11I Illill/ �JP GASrER AR00034184 J L STATE OF L G / IIIIII Oa � B r a 00 RV w rc U W 0 Do IS W O 0 ^mva Q a i0a U w O N S r ) > W F ry Do > m ¢ y w 0 0 m 0 z u � u z 3 Y w 2 z - w 52 O § 2 W W 200 D D.D. A L IDEAS, DESGNSPNO F4HS (ORIGINAL WORKS OF AUTHORSHIP FIXED INATANGIME IEDUM OF E%PPESSGN) INDICATES OR PRESENTED BY THESE DRAWINGS AND DOCUMENTS AAEOW NED BY, AND ARE THE PROPERTY OF MRSCH DESIGN. ALLRIGHTS RESERVED, EXCEW FOR USES EXPRESSLY FEES= N WRITING ELECTRICALIDATA PLAN - FIRST FLOOR (LOCATION ONLY) A901