HomeMy WebLinkAboutE100 FIRST FLOOR POWER AND LIGHTING PLANSKEY NOTES:
GENERAL NOTES:
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulation
of State and Local Codes
CiityGF Canned (\��
DATE: \ 11/14/19
FIRST FLOOR POWER PLAN
1 SCALE: 1/4" = 1'-0"
HP-1
A:14,16, 18
#10 rt WP
UTILITY METER/
CT CABINET
C6
HP-2
- A:20,22,24
#10
WP
iO
TI MECLOCK S HALL BE SI M I FAR TO TORK#OGI DOA,
8O
SWITCH FOR SWITCH LEG'h'CONTROLS LIGHTS
FIELD COORDINATE TIME CLOCK SETTINGS WITH
DIRECTLY OVER STAIRS. REFER TO SHEET E200
OWNER.
FOR LIGHT FIXTURE LOCATION.
2O
PROVIDE ON/OFF &RAISE/LOWER 0-10 VDC
O
OUTLET FOR OWNER EQUIPMENT. COORDINATE
DIMMING STATION COMPATIBLE WITH LIGHT
FINAL LOCATION AND HEIGHT WITH OWNERS
FIXTURE(S) INDICATED.
EQUIPMENT SUPPLIER.
O
INSTALL DEVICES ON FURNITURE BLOCKING.
10
BUILDING SIGN. SEE ARCHITECTURAL ELEVATIONS
MOUNT DEVICES HORIZONTALLY. FIELD
TION A 0R I T T
COORDINATE EXACT DEVICE LOCATION WITH
SIGN VENDOR.
FURNITURE SHOP DRAWINGS.
it
PROVIDE ROUGH IN WITH DIMMER SWITCH FOR
44)
PROVIDE 120 VOLT CONNECTION TO MOTORIZED
FUTURE OVERHEAD PENDANTLIGHT.COORDINATE
SHADE CONTROL PANEL. FIELD COORDINATE ALL
LOCATION WITH OWNER.
WIRING REQUIREMENTS AND ROUGH -INS WITH
SHADE INSTALLER. COORDINATE REMOTE SHADE
12
SINK TOP AIR SWITCH FOR GARBAGE DISPOSAL.
CONTROLLER STATIONS WITH OWNER. WIRE PER
FIELD COORDINATE INSTALLATION WITH PLUMBING
MANUFACTURER'S WRITTEN INSTRUCTIONS.
CONTRACTOR.
O PROVIDE CONNECTION TO MOTORIZED SHADE.
ROUTE CABLING/CIRCUITRY TO SHADE CONTROL
PANEL. FIELD VERIFY MANUFACTURER'S
REQUIREMENTS. PROVIDE INSTALLATION PER
MANUFACTURER'S WRITTEN INSTRUCTION.
O DISCONNECT AND REMOVE EXISTING TENANT
METERING EQUIPMENTTO ALLOW FOR
INSTALLATION OF NEW AS INDICATED.
O PROPOSED ROUTING FOR UNDERGROUND
CONDUITS TO FEED FLOOR MOUNTED
TELEPHONE/DATA/RECEPTACLE OUTLETS. ROUTE
CONDUIT TO NEAREST FULL HEIGHT WALL.
COORDINATE WITH ARCHITECT. 1-1/2"C MIN. SIZE
FOR DATA/TELEPHONE, J' CONDUIT FOR POWER.
FIRST FLOOR LIGHTING PLAN
2 SCALE: 1/4" = 1'-0" A
1. REFERENCE SHEET E001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET E002 FOR DETAILS&
SCHEDULES.
3. REFER TO MECHANICAL DRAWINGS FOR EXACT
LOCATION OF MECHANICAL UNITS.
OVERCURRENT PROTECTION AND FEEDERS
FOR MECHANICAL UNITS SHALL BE SIZED PER
N.E.C. BASED UPON MANUFACTURER'S LISTED
MCAANDMOCP. UNLESS NOTED OTHERWISE
IN MECHANICAL SCHEDULE, PROVIDE A LOCAL
DISCONNECTING MEANS SIZED PER NEC FOR
UNIT. MAINTAIN PROPER NEC REQUIRED
CLEARANCES FOR DISCONNECT.
4. E.C. SHALL PROVIDE ALL RACEWAYS FOR
CONDUCTORS FOR HVAC INTERLOCKS AND
THERMOSTATS. PRIOR TO ROUGH -IN,
COORDINATE EXACT REQUIREMENTS WITH
M.C.
S. BRANCH CIRCUIT NUMBERS SHOWN ARE FOR
GROUPING PURPOSES ONLY. FIELD VERIFY
EXACT CIRCUIT NUMBERS.
6. ALL EXTERIOR BUILDING MOUNTED LIGHT
FIXTURES SHALL BE TIMECLOCK/PHOTOCELL
CONTROLLED.
* ALL EXIT LIGHTS AND LIGHT FIXTURES HAVING
A BATTERY INVERTER UNIT SHALL HAVE
UNSWITCHED CONDUCTOR. CONNECT LIGHT
FIXTURE TO NEAREST UNSW ITCHED BRANCH
LIGHTING CIRCUIT.
8. ALL DIMMER LIGHTING CONTROLS SHALL BE
0.10 VDC COMPATIBLE WITH FIXTURE.
COORDINATE STYLE OF CONTROLLER WITH
OWNER.
MITSCH
D E S I G N
200 S. Rangeline Rd. I Suite 226
Carmel, Indiana 46032
317.573.2222
vww.mlti chdesign.com
GOODERUM & ASSOCIATES ENGINEERING
MEP Consulting Engineers
874 Cheltenham Way
Avon, IN 46123
P: 317.506.8151
F: 317.745.5761
E: dave@gnaengineering.com
I
Q
W
LLB
W
N
Z
F-
0
0
T
��
o
U
w
0
z
��
L
QQ�
Q�
o>
W
U)
J3:
W'
O
w
�
O
w
�0
Q
CO
Z
z
U
N
U
EL
No.
02003`
STATE 6
HL`
DATE : 09-19-2019
O
NAN
J
ST
U
n
ry
to CopU
w
ED
So
d o
So
IS
Z
W
O
h
m
u
w
r
Z
O
U �
w
m
W=
U N
K O
p
urw
¢3¢U
VE
SOU
oaa
U6
ALL IDEAN DESIGNS AMID BANS (ORK31NALFWOWS OF
EXPRESSION)AUTHORSHIP FIXED INA TANGIBLE ME OUR INDICATED OR PRESENTED BY THESE DRYMANNESAND
DOCUMENIS ARE OWNED BY, ANDA� THE PRORTY OF
MrtSCXO sEXPRESSLY PERMITTED IN WRITING. F ROSES
FIRST FLOOR
POWER &
LIGHTING PLANS
E100