HomeMy WebLinkAboutE200 SECOND FLOOR POWER AND LIGHTING PLANSKEY NOTES: GENERAL NOTES: RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Calmed (� �VT�'la>nckw�L DATE: \ 11/14/19 SECOND FLOOR POWER PLAN 1 SCALE:1/4"=11-0" 2,151 FT2 O REGLET LIGHTED UCHANNEL SYSTEM. PROVIDE INSTALLATION PER MANUFACTURERS WRITTEN INSTRUCTION. O PROVIDE OWOFF&RAISE/LOWER DIMMING 0-10 VDC STATION COMPATIBLE WITH LIGHT FIXTURE(S) INDICATED. 3O PROVIDE 4' X 8' 3/4" FIRE RATED CDX PLYWOOD FOR TELEPHONE BACKBOARD. 4O ROUTE (2)3" CONDUITS FROM BUILDING TO NEW TELECOMMUNICATIONS UTILITIES TIE-IN POINT. COORDINATE ALL WORK WITH UTILITY COMPANY. PROVIDE PULL STRING IN CONDUIT AND BUSH CONDUIT ENDS. SO COORDINATE EXACT LOCATION AND METAL FLOOR BOX STYLE WITH FLUSH COVER WITH OWNER. O PROVIDE ROUGH IN WITH DIMMER SWITCH FOR FUTURE OVERHEAD PENDANT LIGHT. COORDINATE LOCATION WITH OWNER. O SINK TOP AIR SWITCH FOR GARBAGE DISPOSAL. FIELD COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR. SECOND FLOOR LIGHTING PLAN _A_ 2 SCALE: 1/4"=Vi 1. REFERENCE SHEET E001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. REFERENCE SHEET E002 FOR DETAILS & SCHEDULES. 3. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF MECHANICAL UNITS. OVERCURRENT PROTECTION AND FEEDERS FOR MECHANICAL UNITS SHALL BE SIZED PER N.E.C. BASED UPON MANUFACTURER'S LISTED MCAANDMOCP. UNLESS NOTED OTHERWISE IN MECHANICAL SCHEDULE, PROVIDE A LOCAL DISCONNECTING MEANS SIZED PER NEC FOR UNIT. MAINTAIN PROPER NEC REQUIRED CLEARANCES FOR DISCONNECT. 4. E.C. SHALL PROVIDE ALL RACEWAYS FOR CONDUCTORS FOR HVAC INTERLOCKS AND THERMOSTATS. PRIOR TO ROUGH -IN, COORDINATE EXACT REQUIREMENTS WITH M.C. 5. BRANCH CIRCU IT NUMBERS SHOWN ARE FOR GROUPING PURPOSES ONLY. FIELD VERIFY EXACT CIRCU IT NUMBERS. 6. ALL EXIT LIGHTS AND LIGHT FIXTURES HAVING A BATTERY INVERTER UNIT SHALL HAVE UNSWITCHED CONDUCTOR. CONNECT LIGHT FIXTURE TO NEAREST UNSWITCHED BRANCH LIGHTING CIRCUIT. 2,151 FT2 MITSCH D E S I G N 200 S. Rangellne Rd. I Suite 226 Carmel, Indiana 46032 317.573.2222 WorW.mBachdesign.com GOODERUM & ASSOCIATES ENGINEERING MEP Consulting Engineers 874 Cheltenham Way Avon, IN 46123 P: 317.506.8151 F: 317.745.5761 E: dave@gnaengineering.Dom I w w N O (n U w �Ofz ono w Z U) J W Z LL.I o :5 Q 00 LJJ Q U N U d No. 02003' STATE OF H DAATT IIDE: 09-19-2019 O rvry J � ry � m m�� O N O W N N j W Z O ❑ W m Z�N U W � QZY �Z~ F U rclzw []¢x O �mQ R6a U ALL IDEAS. DESIGNS AND FLING SORIGMAL VAIMS OF AUTHORSHIP FLYEO IN ATANGISIE MEDi OF E V RESRONU INI)i OR PRESENTED BY THESE DRAWINGS AND DOCUMENTS ME OWNED BY. AND ARE THE FroREmY OE MIISCX DESIGN FOR USES EXPRESSLYPERMITIED IN WRG. NIN SECOND FLOOR POWER& LIGHTING PLANS E200