HomeMy WebLinkAboutM002 HVAC DETAILS AND SCHEDULES45 DEG RECTANGULAR DUCT BRANCH OCL CONNECTION J/ TAKE OFF. HAMMER LOCKED OR FLANGED AND FULLY SEALED J � I LL o: 31Y MAX ECCENTRIC TRANSITION MAX, 30 DEG. ROUND SHEET METAL DUCT TO DIFFUSER V.D. 1° 45 DEG. HIGH EFFICIENCY TAKE OFF COMPLETELY JJ SEALED 3W MAX OFFSET. PROVIDE MINIMUM 2" STRAIGHT SECTION AT EACH END. MAX 30 DEG. A NOTE: IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R=A). WHERE "R" IS EQUAL TO OR GREATER THAN "A" MINIMUM RADIUS (R)-4INC HES. U CONCENTRIC TRANSITION MAX, 45 DEG. DIVERGING AND 60 DEG. CONVERGING IT • 1YB" NOTE: DOUBLE THICKNESS TURNING VANES TO BE USED WHERE NORMAL RADIUS ELBOW IS IMPRACTICAL & WHERE ELBOW IS WITHIN 5 FT OF A BRANCH TAKE -OFF. DUCT CONSTRUCTION DETAILS ASCALE: NONE SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER ELBOW FITTING WITH DRAWBANDS. SHEET METAL ELBOW SEAL ALL RIBS AND CONNECTION TO DIFFUSER NECK SUPPLY DIFFUSER FLEX DUCT MAXIMUM LENGTH SHALL NOT EXCEED T-0" ACT CEILING B LAY -IN DIFFUSER DETAIL SCALE: NONE LINED RA PLENUM BOX FULL SIZE OF FAN COIL INLET REFRIGERATION PIPING. INSTALL PER MANUFACTURES RECOMMENDATIONS SUPPLY AIR DUCTING FILTER RACK FAN COIL INSULATED OUTSIDE AIR DUCT WITH MOTORIZED AND MANUAL DAMPER. ROUTE TO WALL CAP RETURN AIR DUCTING 20" MIN WORK AREA CAP AND PROVIDE WATER SHUT OFF SWITCH IN DRAIN PAN. } PVC DRAIN FROM TRAP WITH CLEAN OUT. SLOPE AT MIN;'" PER FOOT AND SUPPORT TO STRUCTURE MINIMUM 5' O.C. SECONDARY DRAIN PAN, EXTEND MINIMINUM 6" PAST ENTIRE FAN COIL SUPPORT AT MINIMUM 16" O.C. HORIZONAL FAN COIL DETAIL C SCALE CASED EVAPORATOR COIL SHALL MATCH FURNACE WIDTH. INSTALL MANUFACTURERS DEFLECTOR PLATE ON HORIZONTAL APPLICATIONS. TXV METERING DEVICE INSTALL ALL REFRIGERATION SPECIALTIES AS INDICATED ON EQUIPMENT SCHEDULES. PITCH SUCTION LINE TOWARD COMPRESSOR. PROVIDE OIL RETURN TRAPS PER MANUFACTURES PIPING RECOMMENDATIONS. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel DATE: 11 /14/19 AIR COOLED CONDENSER INSTALL WITH MANUFACTURERS RECOMMENDED CLEARANCES.. REFRIGERANT PIPING SIZED AND INSTALLED PER MANUFACTURERS. REFERENCE LONG LINE APPLICATION REQUIREMENTS WHEN APPLICABLE FIBERGLASS PAD BY MC UNIT SHALL BE SET LEVEL ADJUST GRADE AS REQUIRED. PIPE INSULATION LOCATED OUTDOORS SHALL BE PAINTED WITH UV RESISTANT ARMAFLEX PAINT. REFRIGERANT TUBING WITH 1/2" WALL ARMAFLEX INSULATION. PVC SLEEVE AND SEAL WALL PENETRATIONS WATER TIGHT AND FLUSH TO SURROUNDING FINISH. HEAT PUMP DETAIL D SCALE: NONE EXHAUST FAN SCHEDULE TAG MODEL# LOCATION TYPE FAN AND DESCRIPTION FAN DATA MOTOR DATA NOTES CFM ESP SONES HP WATTS VOLT FLA EF-3 GREENHECK SP-A90 RESTROOMS CEIUNG ]5 .2 1.0 30 1 120 1 34 iO iO FAN SHALL BE CONTROLLED FROM WALL SWITCH. 2O PROVIDE WITH LINE VOLTAGE COOLING ONLY THERMOSTAT. DIFFUSERS, REGISTERS AND GRILLES TAG DESCRIPTION MFR MODEL MAIL. CFM MOUNTNG STYLE INTEGRAL DAMPER NOTES: S-1 9"X9" SURFACE MOUNT DIFFUSER PRICE BCD STL 0-200 SURFACE YES 0O2 S-2 24"X24" LAY414 DIFFUSER -8"NECK PRICE BCD STL 130-220 LAY -IN NO iO O2 S-3 24'X2� LAY414 DIFFUSER - 6m NECK PRICE BCD STL 0-120 LAY -IN NO S4 12X4 DOUBLE DEFECTION REGISTER PRICE 520 STL 140-230 SURFACE YES iO O2 R-1 24X12 FIXED BLADE GRILLE PRICE 53D STL 0-1000 LAY -IN NO iO O2 R-2 BX4 FIXED BLADE GRILLE PRICE 530 STL 0-175 SURFACE NO D( O3 R-3 24X12 PERFORATED GRILLE PRICE 10 1 ALUM 1 0420 ISURFACEI NO iOO2 O3 O COLOR:WHITE O2 REFER TO FLOOR PLAN FOR EXACT CFM. O3 PROVIDE WITH LINED REGISTER BOX. HEAT PUMP SCHEDULE MARK MANUFACTURER MODEL COOLING HEATING ELECTRICAL SPECIFICATIONS NOMINALg TONS MBH SEER MBH HSPF ELEC. (V-Ph-Hz) MCA MOCP NOTES: HP-1 BRVANT 214DPA060000 5.0 60.0 14 54.5 8.2 208230-34i0 21.5 30 1 2 3 HP-2 BRVANT 214DPA060000 5.0 60.0 14 54.5 8.2 208R30-34i0 21.5 30 1 2 3 O PROVIDE CYCLE PROTECTOR, OUTSIDE AIR THERMOSTAT, LOW PRESSURE SWITCH. O ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL DISCONNECT SWITCH. O3 ALL HVAC EQUIPMENT TO BE FIELD LABELED TO IDENTIFY WHICH AREA OF THE BUILDING THE SERVICE. FAN COIL SCHEDULE ELECTRIC HEAT MARK MANUFACTURER FCU MODEL HEAT KIT MODEL HEATING CAPACITY COOLING ELECTRICAL SPECIFICATIONS TOTAL CFM CA CFM STATIC PRESS. NOTES: KW @208 MBH @208 NOMINAL TONS REFG. ELEC. (V-Ph-Hz) MCA MOCP FGi BRVANT FB4CNP061L00 KFCEH3401F24 18 61.4 5.0 R410A 20MO-3 77.8 80 1990 .5 OO FC-2 BRVANT FB4CNP061L00 KFCEH3401F24 18 61.4 5.0 R410A 20"0-3 77.8 80 1990 .5 1 O2 O PROVIDE PROGRAMABLE DIGITAL DISPLAY THERMOSTAT. O2 PROVIDE MANUFACTURER FILTER KIT AND SINGLE POINT CONNECTION KIT FOR HEATER. VENTILATION AIR CALCULATIONS SYSTEM AREA TYPE TOTAL NET AREA OCCUPAN TSPER 1000 FT CALCULATED OCCUPANTS CFM/PERSON REQUIRMENT PEOPLE CFM REQUIRED AREA CFM RQUIRME CFMIFT2 AREA CFM REQUIRED TOTAL CFM REQUIRED CONFERENCE ROOM 453 50 23 5 115 0.06 28 143 FC-1 CORRIDOR 1165 0 0 0 0 0.06 70 70 OFFICE 534 5 3 5 15 0.06 33 48 TOTAL 2152 261 OFFICE 1177 5 6 5 30 0.06 71 101 FC-2 CORRIDOR 175 0 0 1 0 1 0 1 0.06 59 59 TOTAL 2152 160 REFRIGERATION LINE SET INSTALLED PER MANUFACTURERS RECOMMENDATIONS. PROVIDE OPEN SITE TEE WITH MOISTURE SWITCH ON SECONDARY DRAIN CONNECTION. INTERLOCK WITH ACCU. 3/4" PVC DRAIN LINE INDIRECTION CONNECTION TO MOP SINK OR FLOOR DRAIN IN MECH ROOM FAN COIL UNIT 18" MIN. PROVIDE LINED SHEET METAL RETURN AIR BOX UNDER FCU. NO SIDE CONNECTIONS ALLOWED. E FAN COIL DETAIL SCALE: NONE FRESH AIR DUCT WITH MOTORIZED SHUT OFF AND MANUAL BALANCING DAMPER. LINED RETURN AIR RISER. FILTER BOX MITSCH D E S I G N 200 S. Rangeline Rd. I Suite 226 Carmel, Indiana 46032 317,573,2222 w .milschdesign.com GOODERUM & ASSOCIATES ENGINEERING MEP Consulting Engineers 874 Cheltenham Way Avon, IN 46123 P: 317.506.8151 F: 317.745.5761 E: dave@gnaengineering.com Q WLLI w N z 0 LL CD O W � w LL- Q Q Q 0 o LU (q Jwz W Z O :5 _J WEll cH LL (Y NGN Q CO Q U^J No. 02003' SWE OF "'MuUrrvlx�iS�l�nma"°m.. DATE: 09-19-2019 O rL m m w Y m $$ j N N wo d W m h 5 o 696 U m N >O> W � O U W m W ZUm K U o 4 qax rcrcw � O is U U LL M1 LL U ALL IDEAS. DESIGNS AND PLANS IORIGIML WORKS OF AUTHORSHIP FIXED IN ATANGINLE MEDIUM of EXPRESSIOID INDICATED OR PRESENTED BY THREE DMWINGS AND DOCUMENTS ARE OWNED By. AND ME THE PROPEM OF MRSGIDESIGN. ALL RIGHTS RESERVED, EXCEPT FOR L6E8 EXPRESSLY FERMHTED IN WRRING. HVAC DETAILS & SCHEDULES M 002