HomeMy WebLinkAboutC-103 Utility Plan (V3)x
I I ❑
I � I
I I I
I
I di
j I o
I I I
I I I
PROPOSED LEGEND
EXISTING LEGEND
I =
I ❑
�
WATER VALVE
®LP
Light Pole
----ol�---oHF
Overhead Utilities
I I
I
FIRE HYDRANT
OUP
UtilityPole
----Ur---- UT-
Underground Telephone
I I
4
SIGN, AS NOTED
w TB
Telephone Box
----w---- °v-
Underground Water
I diF.D.C.
I o
FIRE DEPT. CONNECTION
O WINK
Water Manhole
----UG----U�-
----UE----UE—
Underground Gas
g
Underground Electric
I
I
1.5 F
1.5 FIRE WATER SERVICE
1" DOMESTIC WATER SERVICE
o WV
o WM
Water Valve
Water Meter
----uc— uc—
---
Underground Communications
I
I
1"D
CABLE TV
�rFH
Fire Hydrant
---
Right -of --Way Llne
=
w
ELECTRIC SERVICE & METER BANK
eGV
Gas Valve
FL
Flow Line
F_
TELEPHONE
oGM
Gas Meter
TB
Top of Bank
TIC
UE —
UE
UNDERGROUND ELECTRIC
oCO
Sewer Clean Out
D.E.
Drainage Easement
I II
UT —
UT
UNDERGROUND TELEPHONE
0 AD
Area Drain
P.U.E.
Public Utiltiy Easement
I i
uc
uc
UNDERGROUND CABLE TV
0 MH
Storm Manhole
I.E.
Invert Elevation
P
Ili"W
—
z"W
2" WATER SERVICE
6" SDR 35 PVC SANITARY SEWER
® CI
+
Curb Inlet
Sign
LS
Landscaping
II
_.,%�
PIPE FLOW DIRECTION
I
II
P-#XXX
n0003KAOK3UNEELE
STORM PIPE, LENGTH & SIZE AS NOTED
YY-LF x ZZ STORM
o
U-) 6" SANITARY SEWER LATERAL
coo
SANITARY SEWER CLEAN -OUT (TYPE 2)
SSD
SUBSURFACE DRAIN
I
I
o
TREE PRESERVATION FENCING
\� `��
T8"Tree
��
I� ❑-� A
--- 892
II �lJ
it =
j
l
I
\
®PC/lea
I
I it I
/J I SSMH Rim= 893.70'
IE (N)= 890.05'
IE (NE)= 890,05' I I ❑ �, J 5" x 6" Tee
IE (NE)= 890.19' I I Exist. Brush FieFd-Verifyxist.LD /Hydrant��
I 5 yf _ Fire \
' I IE (S)= 889.15' I I I/ V4skeAsk �� & Service Line Size — — — — — — — — - i ` ` '
I / , / Assembly � � `.�9 �------ _- � /
----�0 i j 11 6" DBH ocation & Quality 6" Gate Valve ,���� ,p /
I\ Request Letter I i 2" 450 Be ds `
3 I I )/� I & Traffic Plan I /�� Exist. Brush _ 6" x 2" Reducer
j I � /I Submitted to I II White Muhbg�y _-----_______ _ S96 - - — - - - - - - - - - - — - - ----- �\ Proposed Electric Ser �e� \\\
City BPW Prior I " DBH ,��, _ - i Coordinate Size & Location \
--- — J w/ Local Utility Co. `�
3 c /1// rr?-894 __- to Installation e_ -3H0___-3HO- �Ho P�N17--�;{p---gun___ —
❑ ❑ /"a/ I i I _—� — ZH11 NB�11— �qfS—==--- =—�F10
6'W 6'W 6'W 6'W//—d—W 6•W 6'W 6 6' \ 6 6•W 6'W 6'W 6'W 6'W 6'W 6'W — 6'W — 6'W 6' 2•W UP w/Trans 898 \ /
1 CI-20289 1 1/ //I 1 I I 1 b 1 - ct
I Rim= 894.6' �� 6
12"x6" Wet Tapping
Valve & Sleeve
`
IE (W)= 891.96'
IE (S)= 891.85''
G) i � � I I I 1 ? � / g9� - '/,,,__- 2x �5" Tee _ /•
Gate Valve /
❑ I I I N I I I 1 I ' / i' P-100 6" _DR33 VC 1.5" 89
----------- 90° Bend w
- I I I /, ' 113 J�F@g1.0% (min) 2" x 1" Reducer
-----c
---------------------- 3 -- \ I I c c\ II I NI I❑ c�1I I
-- 'I— S91- S---- SS--- SS-- S-S�S
IoI 6•SS_ 6•s 30' BSL 30LY
6 6•SS �30' LBY30'BSL
6"SS-7— WSS 6'
SS
- < \ O
FDC CID
n I ,
in I \I
7X ------------ ---a - ;f I I I ,i rn w _ FF = .00
-----------------L-�_� I I d _
113
11 L I L, CI- 0242 I
I Rim= 894.60'
gg5' c❑ n IE (M= 891,52' I BU �H �� 1 r w 900
1 I IE (N W)= 891.56' 1 2DBH
I IE (W)= 891.34'
________ I-- I I I I I I IE (S)= 891.44' I I / I / I p In
\
o
--------y 11 I/ I C I I
0 4.0' 4. \I I�>-
I I/ I I _ c / / m I p r I Sugar Maple
c❑ O 0 0 20" DBH O
CO/ 1I Ma `-4 o -
I I ?i2� I II I❑ I I /� / I " D❑BH 14.96' o
MH-20449 1 1 I I I ���� I U_ I ce \ t7 / I o p -
Ri r�r�= 486.82' I I R961 I I t c❑ / \ / 1 / /
IE(E)-482.43' I I � �\cci J�� `� I r'� I \ - 26.6-14�46,\
IE (S)= 482.32' I I I I `. cn\\I I I \ I / ri I �-
I I I I �\ T�\I ill -r \ FF = 901.25 , \
� I
` _J
� I �
\I I
I\ I
\
\
\
\
Wild \\
Persimmon
16" DBH \\
\
\
\
I �
o � �
/
/
o^
m /
1
I 1
I
1
IIc i / 4.0' BFE = 874.2
co/ / I w `
I i i i it I I i ry
I I I I I II C❑ I , I a r / n pi //
90,
\`� 30' LBY .' Black
30' LB Water Meter 15/67' 14.46' �/
I I Walnut
II I Ip j I� 7 ocaion tIDBHo \\
Per Utility Co. / 14.96' o 26
II /
II
46.83' a' 20' B5L \
I
16" p PP e GM ? /,// astern
�DO // a ec bucl Cluster
UG 1 I UG UG tIG —� l�G I (6) 5" DBH's
cTr 0 I I I �� / 899 __ Common
11 I
I vNi� I ❑I I I CI / --
I I I 1 E.- I I 1 1 _ ` Hackberr
UG UG G UG UG UG u �' 9�2 Y
II I c I c '�/ u uc �� Uc _ uc — — U — uc uc — uc�18" DBH
L I " II i' O _T — o Hawthorn
10" DBH --
9
II a if /— / Sweet Crab Apple / Proposed Gas Service Proposed CATV Service
Y O / 18" DBH / Coordinate Size & Location ordinate Size & Location
w/ Local Utility Co. i w/ Local Utility Co.
j I II Eastern 0 / �// q0
I II II WhiteXlne
I 20BH
II 1
ti I I
HORZ: 1"=20' i I i1 `1-896.84
20 0 20 40
I I ul�
I I I I ry
V) I I I
ti I II
NOTE:
ALL DIMENSIONS TO FACE OF CURB (FC), EDGE/PAV'T i III it I
AND/OR FACE OF BUILDING UNLESS OTHERWISE NOTED. N I I
I I I
I I I
BUILDING DIMENSIONS SHALL BE VERIFIED WITH I I
I I I
ARCHITECTURAL PLANS. N I
I I I
ONLY MAJOR/OVERALL BUILDING DIMENSIONS SHOWN 1 I
I I I
HEREON. I I
rn
0 I
I I I
1 I I
I I I
I I I
V) I
UTILITY NOTES
The Contractor is cautioned that the location and/or elevation of existing utilities as shown on
these plans is based on records of the respective utility companies, and measurements taken
in the field. This information is not to be relied upon as being exact or complete. The
Contractor shall notify all utility companies & the State's underground locate service at least 2
(business) days before commencing excavation to request the utilities be located in the field.
If any existing structures/utilities to remain are damaged during construction, it shall be the
Contractors responsibility to repair and/or replace the damaged structure/utility as necessary
to return it to existing conditions or better.
The Contractor shall be responsible for notifying all property owners that will experience an
interruption to their utilities caused by this project.
Construction shall comply & be in conformance with all applicable governing codes and be
constructed to same. Material specifications shall be in conformance with the State
Department of Transportation's (DOT) standard specifications, latest edition.
Contractor shall provide & maintain traffic control in accordance with the Manual on Uniform
Traffic Control Devices, latest edition.
All materials, installation, construction & testing of the water and sewer utilities shall be in
conformance with Local Water & Sewer Depts. Standards and Specifications, latest edition.
Contractor shall coordinate the installation of building sewers / service laterals with the local
water & sewer depts., building inspector, plumber, and plumbing plans. Installation and
materials shall be in conformance with applicable codes, standards, and regulations.
Contractor shall coordinate actual location of proposed utility services with architectural plans.
The Contractor shall install all water and sewer service lines to 5' outside the building for tie-in
by the plumber.
Water lines shall bear NSF seal of approval and meet:
3" thru 8" mains and service lines - C-900 PVC, Class 200 per AWWA C-900.
Smaller than 3" - Type 'L' Copper per ANSI 816.22 or PVC, Class 200 per ASTM D1784 and
D2241.
Sanitary sewer pipe shall be as follows:
8" & larger mains - SDR 35 PVC (min.) in accordance with ASTM D-3033 & 3034 or PVC Truss
Pipe in accordance w/ ASTM D-2680.
6" services (laterals) - Schedule 40 PVC or SDR 26 PVC and as required by local jurisdiction.
Water mains shall be saddle tapped and bedded with sand a minimum of 6" below and 12"
over the pipe.
All fill material shall be in place and compacted before installation of proposed utilities.
All utilities shall be installed, inspected, and approved before backfilling.
All proposed road crossings must be fully backfilled with a granular material.
Contractor shall maintain a minimum of 54" cover on all waterlines and 36" cover on all
sanitary sewer lines.
Detectable line marking tape and No. 12 insulated copper tracing wire shall be installed with all
water lines and sanitary sewer laterals. All tape shall be placed 24" (min.) above lines.
Tracing wire shall be taped to the top of the water line and be pulled into valve boxes and
meter pits (to the surface) for locating purposes. If ductile iron pipe is used, the main must be
poly wrapped and marking tape installed 2-feet above the water main.
All water joints and bends are to be mechanical joints with thrust blocking.
All storm pipe entering structures shall be grouted to assure a watertight connection.
All storm structures shall have a smooth uniform poured mortar invert from invert in to invert
out. The inside of all structures where storm pipes connect shall be grouted smooth.
Storm pipe lengths provided are measured to center of structure and/or end of Flared -End
Section.
Water lines shall be installed with 10-feet of horizontal and 18-inches of vertical separation
from sanitary and storm sewers.
Provide 8 feet (min.) of horizontal separation between the water main and all storm and
sanitary structures.
Where water lines and sewers cross and the water line cannot be placed above or below the
sewer with a minimum of 18 inches vertical clearance, the sewer must be constructed of water
works grade ductile iron pipe with mechanical joints or plastic (S.D.R. 26) sewer pipe with
gasketed, compression - type joints within ten feet of the water line.
Where water lines and sewers run parallel and a minimum seperation distance of ten feet
cannot be maintained, the sewer must be constructed of water works grade ductile iron pipe
with mechanical joints or plastic (S.D.R. 26) sewer pipe with gasketed, compression -type
joints.
Clean -outs shall be installed on sewer services within 5'
of the building, at 100' intervals (max.), and at every
horizontal & vertical change in direction greater than 450
Clean -outs shall be of the same size as the service line
and be extended to grade.
Sanitary sewers shall be installed in accordance with the
Indiana State Board of Health Specifications (330 IAC 3.1).
Permits shall be obtained prior to commencing work.
This drawing and/or specifications is provided as an instrument of service
provided by Cash Waggner & Associates, PC and is intended for use on this
402 EAST 1 3TH STREET
N ❑.
DATE
BY
DESCRIPTION
WILLOW HAVEN SENIOR HOMES
DATE:
project only. All drawings, specifications, designs, models, ideas, calculations,
and arrangements appearing herein constitutes the original and unpublished
Work of and remains the property of Cash Waggner & Associates, PC. Any
`A` G A` ,�
SUITE 1 O 1
JASPER, IN 47546
(n
PROJECT No.: 19-3957
PROJECT:
MEMORY CARE HOMES
A
❑ ■ ■ 7
0
mm.dd.yy
INI
Description
reproduction, use or disclosure of the proprietary information contained herein
without the prior written consent of the Cash Waggner & Associates, PC is
`v `v
ENS G�
CASH W A G G N E R P 8 1 2. 6 3 4. 5 0 1 5
❑
A
DESIGNEDBv:
N RW
ADDRESS:
1 3 1 4 S WEST ROAD
DRAWN BY:
I DJ M
DRAWING N❑.
strictly prohibited.
Written dimensions shown hereon shall take precedence over scaled dimensions.
p v
NSA
� O
H:
FAX: 131 2.6 3 4. 5 0 1 7
�
C A R M E L, I N D I A N A 4 6 0 7 4
Contractors shall calculate and measure required dimensions. Notify Cash
Waggner & Associates, PC with any variations in dimensions or conditions from
those indicated these drawings. This drawing based
�� p,P R G /�
O
CELL. 8 1 2.6 3 1 . 3 9 6 4
Sc A S S � C 1 A T E S,
_
W
0
FILENAME:
13957 Base
on was on available
information. Commencement of Work constitutes verification and acceptance of
/� / �(//
w `O oc (
Pc EMAIL: N WAG G N E R@
Q
LAYOUT TAB: I
GradingC
UTILITY
1 3
Q
I�
SCALE:IASSIIOWn
existing conditions.
`v
C A S H WA G G N E R. C❑ M
CONSULTING IENGINEERINGISURVEYING
�
SHEET TITLE:
Application of a material or equipment to Work installed by others constitutes
acceptance of that Work and assumption of responsibility for satisfactory
S I G N AT LJ R E DATE
CAS wAG
PLAN
�j
1 3
installation.
W W W . H G N E R . C ❑ M
0
❑ F: