HomeMy WebLinkAboutC-110 Storm & Drainage Details (V2)MIN. SLOPE SHALL BE THAT SLOPE NECESSARY TO CONVEY DESIGN STORM AND KEEP WATER IN EASEMENT EXISTING GRADE Q C/7 Q 3 (MAX) PROPOSED 3 (MAX) � = �1 GRADE 1LLJ �L� I I I I I- W LLJ o 0 o I I I I I I I Q � 8" TOP SOIL UNDERCUT SWALE BY 0.2' INSTALL FILTER FABRICS � = TO ALLOW FOR FUTURE SILTING Q J ON PERIMETER OF w U U TRENCH AND OVERLAP AT SUBGRADE LEVEL � O 1" MIN. 12" MIN. ::�� PIPE SHALL CONFORM TO SPEC REQUIREMENTS #8 WASHED AGGREGATE OF SECTION 907 OF STANDARD SPECIFICATION \� MIN. 6" DOUBLE WALL PERFORATED PER 401.01 OF THE STORM WATER TECHNICAL STANDARDS MANUAL TYPICAL SWALE DETAIL NO SCALE Q ry C-D Q z o Q � o � 11] (/) A SI 0 G Q_ or T (Groove —Outlet End) (Tongue —Inlet End) SECTION A -A LEI SLOPE CONCRETE TO DRAIN AWAY FROM C.O. 6" CONCRETE PAD 3500 PSI 45' BEND _ WYE HEAVY DUTY FRAME & COVER —� W/ LETTERS "C.O." CAST IN COVER PER LOCAL STANDARDS. THE COVER & CONCRETE SHALL HEAVE FREELY ON THE PVC PIPE DURING 6„ FREEZE/THAW PERIODS. \1 THREADED PVC CLEANOUT PLUG �Nl GRADE 7\� GRANULAR BACKFILL (3/4" OCK) LEAN CRUSHED `%\ \ PLUG WYE IF SERVICE LATERAL 6" MIN. OF GRANULAR \\ \\:DOES NOT CONTINUE BACKFILL (3/4" CLEAN CRUSHED ROCK) FLOW UNDISTURBED EARTH NOTE: CLEANOUTS REQUIRED ON SANITARY SEWER SERVICE LATERALS AT 5' OUTSIDE BUILDINGS (2—WAY C.O.), EVERY CHANGE IN HORIZONAL & VERTICAL DIRECTION GREATER THAN 45' & AT 100' INTERVALS. C LEAN O UT inch, per side. HORIZONTAL FLARE VERTICAL FLARE SECTION B-B —1/2" R —1/2" R DIA. WALL G or T WT. SEC. A B C D E DIA.+1 R-1 R-2 SKIRT 12 2 1 1/2 530 4 24 48 7/8 72 7/8 24 13 10 1/16 9 3 1/2 15 2 1/4 2 740 6 27 46 73 30 16 12 1/2 11 3 1/2 18 2 1/2 2 1/2 990 9 27 46 73 36 19 15 1/2 12 4 21 2 3/4 2 1/4 1280 9 35 38 73 42 22 16 1/8 13 4 24 3 2 1/2 1520 9 1/2 43 1/2 30 73 1/2 48 25 16 11/16 14 4 1/2 27 3 1/4 2 1/2 1930 10 1/2 48 25 1/2 73 1/2 54 28 17 3/4 14 1/2 4 1/2 30 3 1/2 3 2190 12 54 19 3/4 73 3/4 60 31 18 5/16 15 5 33 3 3/4 3 3/8 3150 13 1/2 58 1/2 39 1/4 97 3/4 66 34 23 3/4 17 1/2 5 1/2 36 4 3 1/2 4100 15 63 34 3/4 97 3/4 72 37 24 1/16 20 5 1/2 42 4 1/2 3 3/4 5380 21 63 35 98 78 43 27 1/4 22 5 1/2 48 5 4 1/4 6550 24 72 26 98 84 49 28 1/8 22 5 3/4 54 5 1/2 4 3/4 8040 27 65 35 100 90 55 32 7/8 24 6 1/4 60 6 5 8750 30 60 39 99 96 61 36 3/4 24 6 3/4 66 6 1/2 5 1/2 10630 24 78 21 99 102 67 35 11/16 24 7 1/4 72 7 6 12520 34 78 21 99 108 73 38 5/8 24 7 3/4 78 7 1/2 6 1/2 14430 24 78 21 99 114 79 41 15/16 24 8 112 84 8 7 16350 24 78 21 99 120 85 144 13/16 24 9 NOTE: Manufacture of end section is in accordance with applicable portions of A.S.T.M. specification C76. PRECAST CONCRETE END SECTION Scale: N.T.S. MASTIC SEAL CASTING TO PRECA PIPS PLAN SECTION AREA DRAIN NCRETE INLET BOX -478 �TING CIFIED TRENCH DETAIL FOR CITY STORM SEWERS NO SCALE 6" MINIMUM OF TOPSOIL OR COMPACTED PAVEMENT SECTION VARIES AGGREGATE #53. LIMIT OF SUBGRADE FINAL BACKFILL Bc +18"/MIN. ._. .. r - *. — SPRINGLINE HAUNCHING (Bc/6) BEDDING MINIMUM COVER SHALL BE PER NOTE 3 LEGEND d Bc = OUTSIDE DIAMETER D = INSIDE DIAMETER d = DEPTH OF BEDDING MATERIAL BELOW PIPE DEPTH OF BEDDING MATERIAL BELOW PIPE d MIN INLET BOX TABLE INLET AREA DRAIN AREA DRAIN AREA DRAIN CURB INLET N "W" 24" 30" 36" 36" m "H" 24" 30" 36" 24" PAVED AREAS EJIW #8308 EJIW #8313 EJIW #8315 EJIW #7030 GRATE TYPE M TYPE M TYPE M z N M2 (IN VALLEY) NON —PAVED AREAS EJIW #6500 EJIW #6610 EJIW #8315 M4 (ON SLOPE) T-1 BACK GRATE ADAPTER RING TYPE M (STRAIGHT CURB) T-2 BACK (ROLL CURB) NOTES: 60" & SMALLER 4" Bc 66" & LARGER 6" 1. BEDDING AND HAUNCHING FOR ALL RCP INSTALLATIONS SHALL BE #8 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT. BEDDING SHALL BE PLACED IN THE TRENCH BOTTOM SUCH THAT AFTER THE PIPE IS INSTALLED TO GRADE AND LINE, THERE REMAINS A 4" MINIMUM DEPTH OF MATERIAL BELOW THE PIPE BARREL AND A MINIMUM OF 3" BELOW THE BELL. FOR PIPE SIZES 66" AND LARGER, THE MINIMUM DEPTH OF MATERIAL BELOW THE PIPE BAREL SHALL BE 6". BEDDING SHALL BE PLACED TO BE UNIFORM AS POSSIBLE, BUT SHALL BE LOOSELY PLACED UNCOMPACTED MATERIAL UNDER THE MIDDLE THIRD OF THE PIPE PRIOR TO PLACEMENT OF THE PIPE. IF THE UNDERLYING SOILS OF THE TRENCH BOTTOM ARE SOFT OR YIELDING, THE SOIL SHALL BE UNDERCUT TO SUCH A DEPTH THAT WHEN REPAIRED WITH #2 STONE IT WILL PRODUCE A UNIFORM AND STABLE FOUNDATION ALONG THE ENTIRE LENGTH OF THE PIPE. HAUNCHING AND INITAIL BACKFILL SHALL BE COMPACTED IN 8" MAXIMUM LIFTS TO NOT LESS THAN 90% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL SHALL BE BROUGHT UP EVENLY ON BOTH SIDES OF THE PIPE FOR THE FULL LENGTH OF THE PIPE. HAUNCHING SHALL EXTEND TO THE SPRINGLINE OF THE PIPE. MINIMUM TRENCH WIDTH SHALL BE THE OUTSIDE DIAMETER OF THE PIPE PLUS 18". 2. FINAL BACKFILL FOR ALL RCP INSTALLATIONS WHERE "L" IS 5' OR LESS SHALL BE B—BORROW FOR STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED IN 6" MAXIMUM LIFTS TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE TOP 6" OF THE EXCAVATION BELOW THE LIMIT OF SUBGRADE SHALL BE #53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. FINAL BACKFILL FOR ALL RCP INSTALLATIONS WHERE "L" IS GREATER THAN 5' SHALL BE CLEAN FILL MATERIAL FREE OF ROCKS LARGER THAN 6" IN DIAMATER, FROZEN LUMPS OF SOIL, WOOD OR OTHER EXTRANEOUS MATERIAL, COMPACTED IN 12" MAXIMUM LIFTS TO NOT LESS THAN 90% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE EXCAVATION. CONTRACTOR SHALL PROVIDE A 3rd PARTY TESTING AGENCY TO PROVIDE COMPACTION TESTING AS NECESSARY. 3. FOR INSTALLATION OF STORM MAINS, WATERMAINS, SANITARY MAINS, WATER SERVICE LATERALS, AND SANITARY SERVICE LATERALS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT OR FINAL GROUND ELEVATION TO THE TOP OF THE INSTALLED PIPE SHALL BE NO LESS THAN 2.5 FEET OF COVER ALONG ANY PART OF THE PIPE. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. 4. IF EXISTING SUBGRADE HAS BEEN LIME STABILIZED, BACKFILL WITH B—BORROW TO BOTTOM OF EXISTING SUBGRADE AND FILL TO THE LIMIT OF EXISTING SUBGRADE WITH COMPACTED AGGREGATE NO 53. 5. THESE STANDARDS SHALL APPLY FOR STORM SEWERS INSTALLED WITHIN EXISTING AND PROPOSED CITY R/W AND FOR STORM SEWERS THAT SHALL BE MAINTAINED BY THE CITY, REGARDLESS OF STORM SEWER JURISDICTION. 6. ALL STORM PIPE WITHIN EXISTING OR PROPOSED CITY R/W SHALL BE REINFORCED CONCRETE PIPE REGARDLESS OF JURISDICTION OVER STORM PIPES. STANDARD CITY OF CARMEL STANDARDS DRAWING 10-31 TRENCH DETAIL FOR CITY STORM SEWERS INLET NOTES: ALL PRECAST UNITS SHALL CONFORM TO ASTM C-478. INLETS SHALL BE BACKFILLED WITH GRANULAR MATERIAL AND COMPACTED IN 8" LOOSE LIFTS TO 95% STD. DENSITY PER ASTM D698 CASTING SHALL BE MASTIC SEALED TO PRECAST UNIT ALL CONNECTING PIPES SHALL BE GROUTED WITH A HIGH STRENGTH, NON —SHRINK GROUT. INLET SIZES SHOWN ARE MINIMUM SIZE REQUIRED & MAY VARY PER LOCAL STANDARDS. FRAME & CASTINGS SHOWN ARE THE TYPE & SIZE REQUIRED FOR THE GIVEN BOX DIMENSIONS. ALTERNATES SHALL EQUAL TO THOSE SHOWN, INCLUDING GRATE & CURB OPENING SIZES. PRECAST INLET BOX Top/Bank 10.5' (MIN.) EXIST. OR N PAVEMENT PIPS VARIES SEE GRADING PLAN 17 RETE CURB INLET C-478 QO PLAN FRONT GRATE (F.G.) ELEVATION /'" ��' r""' PAVEMENT GRADE 4L BOLT HOLES TIC SEAL CASTING PRECAST UNIT SECTION CURB INLET 10.5' (MIN.) �1 3 5' (min.) Top/Bank Elev. = 898.50 DRY DETENTION BASIN CROSS SECTION SCALE: N.T.S. a_a' EMERGENCY SPILLWAY CROSS SECTION Scale: N.T.S. BENEATH OR W/IN 5' OF IN OPEN FIELD PAV'T. CURB, SIDEWALK UNIFORM CUT LINE 6" (MIN.) TOPSOIL\ ASPHALT/GONG NEW STREET EXIST STREET SURFACE SURFACES SOIL BACKFILL— CLASS II GRANULAR MAT L PER ASTM D2321 COMPACTED TO 95% STD. PROCTOR W W aa. a ''z z Cj RI 0 aM m o0 U_ aA — WIDTH CLASS II GRANULAR MAT L PER ASTM D2321 COMPACTED TO 95% STD. PROCTOR i0 —PIPE BEDDING NOTES: CLASS II GRANULAR MAT'L PER ASTM D2321 COMPACTED TO 95% STD. PROCTOR 1. NEW STREET SURFACE SHALL COMPLY WITH LOCAL AUTHORITY JURISDICTION. 2. TRENCH WALLS TO BE SUPPORTED AS REQUIRED BY OSHA. TRENCH WIDTH TABLE PIPE 0 MIN WIDTH 4" 1'-9" 6" V-11" 8" 2'-2" 10" 2'-4" 12" 2'-6" 15" 2'-10" 18" 3'-3" 24" 4'-0" 30" 4'-8" 36" 5'-4" 42" 6'-0" 48" 6'-8" 54" 7'-4" 60" 8'-0" 3. MIN COVER TO BE BELOW OFFICIAL STREET GRADE. TYPICAL TRENCH SECTION HOPE PIPE (N- 1 Z OR EQUAL) N.T.S. This drawing and/or specifications is provided as an instrument of service provided by Cash Waggner & Associates, PC and is intended for use on this 402 EAST 1 3TH STREET N ❑. DATE BY DESCRIPTION WILLOW HAVEN SENIOR HOMES DATE: project only. All drawings, specifications, designs, models, ideas, calculations, and arrangements appearing herein constitutes the original and unpublished Work of and remains the property of Cash Waggner & Associates, PC. Any `A` G A` ,1 SUITE 1 O 1 JASPER, IN 47546 U1 PROJECT No.: 19-3957 PROJECT: MEMORY CARE HOMES A O ■ ■ 7 A mm.dd.yy INI Description reproduction, use or disclosure of the proprietary information contained herein without the prior written consent of the Cash Waggner & Associates, PC is `v `v ENS G�okkk CASH W A G G N E F2 DESIGNED BY: I N RW ADDRESS: 1 3 1 4 S WEST ROAD DRAWN BY: DIM I strictly prohibited. p v P H: 8 1 2. 6 3 4. 5 0 1 5 A! /� ❑ Written dimensions shown hereon shall take precedence over scaled dimensions. � O (\�„r•V/-�\`J/— FAX: 8 1 2. 6 3 4. 5 O 1 7 � I•I C A R M E L, I N D I A N A 4 6 O 7 4 DRAWING No.: FILENAME: Contractors shall calculate and measure required dimensions. Notify Cash Waggner & Associates, PC with any variations in dimensions or conditions from those indicated these drawings. This drawing based �� p,P R G /� /� O CELL. B 1 2.6 3 1 .3964 9 6 4 Sc A S S O C I A TES _ W 0 13857Strm-Dtl on was on available information. Commencement of Work constitutes verification and acceptance of �� /� / �(// A` O oc ( , P C EMAIL: N WAG G N ER@ Q LAYOUT TAB: I Layout STORM sc C 1 1 Q 0 SCALE:IASShown existing conditions. `v C A S H WA G G N E R. C❑ M CO NSULTINGIENGINEERING ISURVEYING � SHEET TITLE: Application of a material or equipment to Work installed by others constitutes acceptance of that Work and assumption of responsibility for satisfactory SIGNATURE DATE CASH WAG DRAINAGE D E T A I L S 11 3 installation. W W W . G N E R . C O M Q ❑ F: