HomeMy WebLinkAboutA100 FLOOR PLANE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City N Carmel
DATE: 11 /14/19
STI
LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
7 WALL
0
Joi)DOOR AND
FRAME
(SEE DOOR
SCHEDULE)
O WALL
DOOR AND
d/ FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW DOORS.
■ AREA NOT IN CONTRACT
❑ AREA OF WORK
KEYED NOTES
1 PROVIDE NEW 24" DEEP, ADJUSTABLE HEAVY-DUTY WHITE
MELAMINE SHELVING ON KV STANDARDS AND BRACKETS. PROVIDE
(5) SHELVES PER CLOSET.
2 FIXED WALL MOUNTED TELEVISION SUPPLIED BY TENANT.
CONTRACTOR INSTALLED, COORDINATE EXACT LOCATION WITH
TENANT.
3 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND
FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL
MODEL, SINK. ELKAY, CROSSTOWN #ECTRU24179R (STAINLESS
STEEL) FAUCET- DELTA, MATEO SINGLE -HANDLE PULL DOWN
#9183-AR-DST (ARCTIC STAINLESS FINISH)
4 PROVIDE NEW SEMI -RECESSED FIRE EXTINGUISHER
CABINEFS.WHERE FIRE EXTINGUISHERS ARE SHOWN ON EXISTING
WALLS, PROVIDE WALL HUNG UNITS. PLACEMENT IS FOR GENERAL
REFERENCE. ALL EXTINGUISHERS SHALL BE PLACED IN
ACCORDANCE WITH NFPA 10.
5 PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM
LOCATION WITH TENANT.
PLUMBING RISER DIAGRAM
TYPICAL ALL SINGLE LOCATIONS NOTTOSCALE
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL
WALLS ARE TO BE [WI] UNLESS OTHERWISE NOTED. NOT ALL WALL TYPES
LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFERTO
REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
STANDARD INSULATED WALL
W 1 3-5/8" METAL STUDS AT 16" O.C.;
ONE LAYER OF 5/8" TYPE "X"
GYPSUM BOARD EACH SIDE;
EXTEND WALLTO UNDERSIDE
OF CEILING. PROVIDE BATT
SOUND INSULATION INSIDE
WALLAND 2'-0" SOUND
INSULATION EACH SIDE OF
WALLABOVE CEILING.
WALL TO DECK
W2 3-5/8" METAL STUDS AT 16"
O.C.; ONE LAYER OF 5/8" TYPE
"X" GYPSUM BOARD EACH SIDE;
EXTEND WALL TO DECK ABOVE.
PROVIDE BATT SOUND
INSULATION INSIDE WALL.
OPARTIAL HEIGHT WALL
W3 35/8" METAL STU DS AT 16" O.C.,
ONE LAYER OF 5/8" TYPE "X"
GYPSUM BOARD EACH SIDE;
EXTEND WALL WITH 12"
COUNTERTOP (FINISHED HEIGHT
OF COUNTERTOP AT 42" AFF);
PROVIDE I" STEEL PIPE ANCHORS
INTOCONCRETE FLOOR FOR
SUPPORTAS REQUIRED.
GENERAL NOTES
1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW
WALLS TO BE TYPE W 1.
2. CLEAN EXISTING EXTERIOR WINDOW BLIN DS. REPAIR DAMAGED
BLINDS WITH NEW TO MATCH BUILDING STANDARD.
3. PROVI DE B RACI NG AND F IRE -TREATED BLOCKI NG AS REQU I RED IN
WALLS SU PPORTI NG CASEWORK, TACKBOARDS/MARKERBOARDS,
RESTROOM ACCESSORIES, EQU IPMENT, OR ANY OTHER MISC. ITEM
REQUIRING ADDITIONAL SUPPORT.
4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEWAND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMU M TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
5. WHERE PLAN INDICATES EXPOSED DECK AT EXTERIOR WALLS,
CONTRACTOR TO INCLUDE PROVIDING, INSTALLING, AND
FINISHING THE DRYWALL ABOVE THE WINDOW HEADER AT THE
EXTERIOR PERIMETER WALLS AS REQUIRED.
6. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE
BOARDS TO BE INSTALLED AT 60" AFF TO CENTER UNLESS NOTED
OTHERWISE. CONFIRM LOCATIONS/ INSTALL HEIGHT WITH TENANT
PRIOR TO INSTALLATION.