HomeMy WebLinkAboutA200 REFLECTED CEILING PLANRELOCATE UFF"i AND
MECHANICAL DIFFUSER RELOCATION
NOT TO SCALE
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel (�
DATE: 11 /14/19
LEGEND
®
LIGHT FIXTURE, 21tK4',UED
MFG: BUILDING STANDARD
STYLE: BUILDING STANDARD
O
LIGHT FIXTURE, RECESSED
C1
CAN, LED
MFG: BUILDING STANDARD
STYLE: BUILDING STANDARD
P0LIGHT
FIXTURE, PENDANT
MFG: TBD
STYLE: TBD
(INSTALL AT VI AFF TO
BOTTOM OF FIXTURE)
P0LIGHT
FIXTURE, PENDANT
MFG: TBD
STYLE: TBD
(INSTALL AT 5'-8" AFF TO
BOTTOM OF FIXTURE)
MECHANICAL NOTES
EX IT LIGHT FIXTU RE
1. SCOPE I NTENT IS FOR EXISTNG M EC HANICAL SYSTEMS TO REMAIN.
EXISTING FLEX DUCT AND DIFFUSERS BEING RELOCATED AS
NECESSARY PER WALL LAYOUT. NO MAIN DUCTWORK BEING
F b
EMERGENCY LIGHT
RELOCATED. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR
FIXTURE
NOTIFYING APPLICABLE PARTIES IF ADDITIONAL WORK IS
REQUIRED.
NL
INDICATES NIGHT
LIGHTLOCATION
2. DIFFUSER LOCATIONSARE SHOWN ON PLAN FOR REFERENCE
ONLY, CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND
E
EXISTING FIXTURE
RETURN AIR GRILLESAS REQUIRED BY CODE.
TO REMAIN
3. FIRE STOPANY EXISTING DECK PENETRATIONSAS REQUIRED.
^
LIGHTCIRCUIT
4. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
6
LIGHTSWITCH
DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAYWITH LOCKOUT
CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT
BEFORE INSTALLING.
5,
LIGHTSWITCH,
3-WAY
by
LIGHTSWITCH,
DIMMER
El DIFFUSER, LAY -IN, 2'x2'
EXISTING CEILING GRID, ALTERNATE: ARMSTRONG,
SUSPENDED, 2Hx2' METALWORKS, MESH,
WELDED WIRE 1 CELL, WHITE
TDIT IN LIEU OF DUNE
CEILING TYPE
CEILING HEIGHT X'-X"
A MFG:ARMSTRONG
TYPE: DUNE REVEAL EDGE
EDGE TYPE: BUILDING STANDARD
GRID: 15/16"
NRC RATING: 0.55
FIRE RATING: CLASS A
B MFG: ARMSTRONG
TYPE: METALWORKS MESH, WELDED WIRE 1 CELL WHITE
GRID: EXISTING
C GYPSUM BOARD CEILING
PAINTED W HITE UNLESS NOTED OTHERWISE ON FINISH PLAN;
PROVIDE ALL ACCESS PANELS REQUIRED FOR MAINTENANCE -
LOCATIONS SHALL BE APPROVED BY PARALLEL DESIGN GROUP;
PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL
BULKHEAD CONDITIONS, SEE SECTIONS FOR VERTICAL RETURN
DIMENSIONS.
DIFFUSER, LAY -IN, 1'X4'
® DIFFUSER, LAY-IN,4"X4'
NOTE: IF IN GOOD CONDITION, EXISTING H.VA.C. DEVICES AND CEILING
TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW.
NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET,
GENERAL NOTES
1. PROVIDE NEW CEILING GRID AND TILE THROUGHOUT AT APPROX.
8'1 (TO MATCH EXISTING CONDITIONS) UNLESS NOTED
OTHERWISE.
2. WHERE MULTIPLE SWITCHESARE SHOWN, PROVIDE (1) GANG BOX
WITH A SINGLE COVERPLATE.
3. PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED
IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN
ON PLAN ARE FOR REFERENCE ONLY.
4. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE
ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSU LTANT AND
ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
VERIFYING THAT LAY -OUT AND TOTAL WATTAGE MEETS ASHRAE
90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE
USE OF EACH SPACE. OVER 50%OF THE LIGHTING WILL BE
REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET.
5. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BEAN
OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND
INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE.
OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT
OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS
DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS
IN OPEN AREAS AS REQUIRED.
6. ALL DEVICES AND COVERS TO MATCH EXISTING.
El
KEYED NOTES
AREA NOT IN CONTRACT
1
EXISTING CEILING GRID AND LIGHTING IN NOTED AREA TO REMAIN
❑ AREAOFWORK
AS -IS.
2
CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT
THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
MAXIMUM OF 2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1.
3
REWORK EXISTING SWITCH FOR NEW OFFICE LAYOUT.
4
TIE RELOCATED LIGHT INTO EXISTING SWITCH FOR HALLWAY.
5
REWORK EXISTING SWITCHES TO 3-WAY TO CONTROL BREAK
AREA 2X4 LIGHTING.
6
REWIRE EXISTING CANLIGHTS TO BE ON THEIR OWN SWITCH IN
NOTED CONFERENCE ROOM.
7
INSULATE CEILING AND PROVIDE SOUND BOOTS FOR NOTED
CONFERENCE ROOM.
REFLECTED CEILING PLAN „
1/8" = 1'-0"
0
a
y
Z w u
Ya
� m�3
w z m
J Z M
J O <
O 0 n
0
6 gym^
a
�09^
m _
w
z
z
O
w
O
u
N
r
r
z
o
a
Ou
r
n
o
0
0
�
y
N
z
NBEo
H LA
z mISO0
u
o N
a N
SC
u m
u
p
N
u
p
o
Go
Go
u
EE
a
Q.
0
L O
N
i O
NN
RED ED
3 w
ro
w1 v c
0 0
Ed
O
�
ro
� s C
N
O
Z C
O
0
O
a
AN `aN`COLEy
`;gip 0\STE/�F�'YS2�
No. 11900087
ZZ
STATE OF
PS
B11 CHIA 0` "
V'
REFLECTED
CEILING PLAN
A200
ALL DEIGNS, CONCEFTEORRANGEMENTS ADD ELSIE
IN SENATOR OR REPRESENTED By THERE DRANINFECARE
CAN NED By WARTALDEGN FRONT INC ANDSHALLNOT BE
DEAD By OR DISCLOSED TO MY FRENCH, RRM OR COMP FOR
ANN REASON WHATAGRACERWITHOUT THEW AFTER CONSENT
CONTRACTORS SHELL VEM FS AN A BE RESPONSIBLE FOR ALL
MIT M BE NOTIFIED OF AN Y DITHEREMINC ME OR ERECTION S
RAM THE DIM FRESH S SHOWN ON THE MEET