HomeMy WebLinkAboutA200 REFLECTED CEILING PLANRELOCATE UFF"i AND MECHANICAL DIFFUSER RELOCATION NOT TO SCALE *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel (� DATE: 11 /14/19 LEGEND ® LIGHT FIXTURE, 21tK4',UED MFG: BUILDING STANDARD STYLE: BUILDING STANDARD O LIGHT FIXTURE, RECESSED C1 CAN, LED MFG: BUILDING STANDARD STYLE: BUILDING STANDARD P0LIGHT FIXTURE, PENDANT MFG: TBD STYLE: TBD (INSTALL AT VI AFF TO BOTTOM OF FIXTURE) P0LIGHT FIXTURE, PENDANT MFG: TBD STYLE: TBD (INSTALL AT 5'-8" AFF TO BOTTOM OF FIXTURE) MECHANICAL NOTES EX IT LIGHT FIXTU RE 1. SCOPE I NTENT IS FOR EXISTNG M EC HANICAL SYSTEMS TO REMAIN. EXISTING FLEX DUCT AND DIFFUSERS BEING RELOCATED AS NECESSARY PER WALL LAYOUT. NO MAIN DUCTWORK BEING F b EMERGENCY LIGHT RELOCATED. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR FIXTURE NOTIFYING APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED. NL INDICATES NIGHT LIGHTLOCATION 2. DIFFUSER LOCATIONSARE SHOWN ON PLAN FOR REFERENCE ONLY, CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND E EXISTING FIXTURE RETURN AIR GRILLESAS REQUIRED BY CODE. TO REMAIN 3. FIRE STOPANY EXISTING DECK PENETRATIONSAS REQUIRED. ^ LIGHTCIRCUIT 4. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL 6 LIGHTSWITCH DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAYWITH LOCKOUT CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT BEFORE INSTALLING. 5, LIGHTSWITCH, 3-WAY by LIGHTSWITCH, DIMMER El DIFFUSER, LAY -IN, 2'x2' EXISTING CEILING GRID, ALTERNATE: ARMSTRONG, SUSPENDED, 2Hx2' METALWORKS, MESH, WELDED WIRE 1 CELL, WHITE TDIT IN LIEU OF DUNE CEILING TYPE CEILING HEIGHT X'-X" A MFG:ARMSTRONG TYPE: DUNE REVEAL EDGE EDGE TYPE: BUILDING STANDARD GRID: 15/16" NRC RATING: 0.55 FIRE RATING: CLASS A B MFG: ARMSTRONG TYPE: METALWORKS MESH, WELDED WIRE 1 CELL WHITE GRID: EXISTING C GYPSUM BOARD CEILING PAINTED W HITE UNLESS NOTED OTHERWISE ON FINISH PLAN; PROVIDE ALL ACCESS PANELS REQUIRED FOR MAINTENANCE - LOCATIONS SHALL BE APPROVED BY PARALLEL DESIGN GROUP; PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL BULKHEAD CONDITIONS, SEE SECTIONS FOR VERTICAL RETURN DIMENSIONS. DIFFUSER, LAY -IN, 1'X4' ® DIFFUSER, LAY-IN,4"X4' NOTE: IF IN GOOD CONDITION, EXISTING H.VA.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET, GENERAL NOTES 1. PROVIDE NEW CEILING GRID AND TILE THROUGHOUT AT APPROX. 8'1 (TO MATCH EXISTING CONDITIONS) UNLESS NOTED OTHERWISE. 2. WHERE MULTIPLE SWITCHESARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 3. PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 4. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSU LTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY -OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 5. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BEAN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. ALL DEVICES AND COVERS TO MATCH EXISTING. El KEYED NOTES AREA NOT IN CONTRACT 1 EXISTING CEILING GRID AND LIGHTING IN NOTED AREA TO REMAIN ❑ AREAOFWORK AS -IS. 2 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. MAXIMUM OF 2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1. 3 REWORK EXISTING SWITCH FOR NEW OFFICE LAYOUT. 4 TIE RELOCATED LIGHT INTO EXISTING SWITCH FOR HALLWAY. 5 REWORK EXISTING SWITCHES TO 3-WAY TO CONTROL BREAK AREA 2X4 LIGHTING. 6 REWIRE EXISTING CANLIGHTS TO BE ON THEIR OWN SWITCH IN NOTED CONFERENCE ROOM. 7 INSULATE CEILING AND PROVIDE SOUND BOOTS FOR NOTED CONFERENCE ROOM. REFLECTED CEILING PLAN „ 1/8" = 1'-0" 0 a y Z w u Ya � m�3 w z m J Z M J O < O 0 n 0 6 gym^ a �09^ m _ w z z O w O u N r r z o a Ou r n o 0 0 � y N z NBEo H LA z mISO0 u o N a N SC u m u p N u p o Go Go u EE a Q. 0 L O N i O NN RED ED 3 w ro w1 v c 0 0 Ed O � ro � s C N O Z C O 0 O a AN `aN`COLEy `;gip 0\STE/�F�'YS2� No. 11900087 ZZ STATE OF PS B11 CHIA 0` " V' REFLECTED CEILING PLAN A200 ALL DEIGNS, CONCEFTEORRANGEMENTS ADD ELSIE IN SENATOR OR REPRESENTED By THERE DRANINFECARE CAN NED By WARTALDEGN FRONT INC ANDSHALLNOT BE DEAD By OR DISCLOSED TO MY FRENCH, RRM OR COMP FOR ANN REASON WHATAGRACERWITHOUT THEW AFTER CONSENT CONTRACTORS SHELL VEM FS AN A BE RESPONSIBLE FOR ALL MIT M BE NOTIFIED OF AN Y DITHEREMINC ME OR ERECTION S RAM THE DIM FRESH S SHOWN ON THE MEET