HomeMy WebLinkAboutA001 LIFE SAFETYLEGEND
CODE SUMMARY
SCOPE OF WORK:
E n
OFFICE SPACE BUILD -OUT REMODELTO PREVIOUSLY BUILT -OUT OFFICE.
r
EXISTING ELECTRICAL PANEL LOCATION
OCCU PANCY CLASSIFICATION:
B(USINESS)
EX
EXISTING EXIT- BUILDING EXIT LOCATION
CHANGE OF OCCUPANCY CLASS:
NO
FE
FIRE EXTINGUISHER
TOTAL BUILDING AREA:
32,225 SF/FLOOR X 4 STORIES = 128,900 GROSS SF
®
EXITSIGNAGE
TOTAL AREA ON FLOOR:
32,225 SQ.FT.
EMERGENCY LIGHTING
TOTAL PROJECT AREA:
NL
NIGHT LIGHT/EMERGENCY LIGHTING,
5,392 SQ.FT.
REFRENCE A200 FOR LOCATION.
OCCU PANCY CALCULATIONS
SPACE TYPE AREA SFPEROCCUPANT OCCUPLOAD
■
AREA NOT IN CONTRACT
GENERALOFFICE 3,715 100 38
STORAGE 436 300 2
❑
AREA OF WORK
LOUNGE 744 15 50
CONFERENCE 497 15 34
TOTAL ACTUAL OCCUPANTS IN PROJECT AREA: 24
NUMBER OF REQUIRED EXITS:
2
SPRINKLER SYSTEM (YES/NO):
YES EXISTING TO REMAIN
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED)
All
APPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
LIFE SAFETY PLAN
1/16" = 1'-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel (�
�V�I��V'�9*tiY`AML
DATE: 11 /14/19
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURALCODE
2008 INDIANA BUILDING (20061BC, ASCE-7-2005)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (20121MC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIREILIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CHI I -ACCESSIBILITY, ANSI A-117.1 STANDARD,
ADA ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH
INDIANA AMMENDMENTS
GENERAL ADMINISTRATIVE RULES 2ND EDITION.
GENERAL NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOU RICE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNSISTROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND
ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND
RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTORTOENSUREALLNEWAND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION
DETAILS
7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN.
0
OL
Z w m
� � a
m�3
J rnDoq
J _ rrnt
o a
U 0
n o
6 = m ^
�0Q^
ao _
w
z
z
O
0
V
w
m
a
U
F
tILL!
m
n
O
U
w
F
N
m
O
Q
0
OI
0
O
w
f
N
N
s
m
m
o N¢
NED
COO
ED!u
O
u a;0
m
K
CAIO
a
0
L O
N
Q
0
Em
V) N
t0
REB V
3 N
ro
W C
N m
C
ro �
O ,EI
•� N 0
E �
— y C
ro
O U
Z C
O
O
a
AN `aN`COLEy
0\STE/�F�'YS2�
= No. EUESO 87
STATE OF
PS
�gRCHIA C` "
V'
LIFE SAFETY
A001
AD DESIGNS CONCRETE A REANGEMENTS AND MARC
IN HEATED OR REMBEHENTED By THERE DIM WIN NO A RE
USED By OR DISCLOSED TO My FRENCH RAN OR MR FOR
AM BROWN WHATECDERMTHOUT THEW BITTER CONSENT
OF PARALLEL DMI GROUP INC
CONTRACTORMEALLVENIFY AND BE REDEEMER MR ALL
A MEN BONS ON THE JOB SHE DRALEL HAND GROUP INC
HURT BE NOTIFIED OF My DINMERANCIESORVAREATIONS
MOM THE DIM ENSIMOSSMAN ON THE MAN